A <strong>Viskan</strong> Lindö placed in the Tesla measuring chamber at the Swedish Technical Research Institute.<br />
A semi-anechoic chamber adapted for emissions and immunity testing.<br />
TESTED AND APPROVED<br />
FOR THE EUROPEAN MARKET.<br />
Electromagnetic compatibility (EMC) is the ability of<br />
apparatus, equipment or a system to operate in its<br />
electromagnetic environment without giving rise to<br />
unacceptable interference in that environment<br />
The EMC Directive (2014/30/EU) is an EU Directive that<br />
applies to electromagnetic compatibility within Europe.<br />
It aims to avoid separate national requirements by<br />
restricting legislation to overall requirements for safety,<br />
health and the environment, or other requirements in<br />
the public interest, and equipment must therefore be<br />
CE marked before it can be placed on the market. With<br />
the CE mark, the manufacturer shows that the product<br />
meets all essential requirements both in the EMC Directive<br />
and in other relevant directives.<br />
HOW THE TEST WAS CARRIED OUT<br />
The test was carried out on a <strong>Viskan</strong> Lindö in the<br />
Tesla measuring chamber at SP – the Swedish Technical<br />
Research Institute. A semi-anechoic chamber built for<br />
projects of this type. Tests are carried out on emissions<br />
and immunity: cable and radiated interference. Measurements<br />
were taken at a distance of 3 m. The absorbent<br />
material was a combi-absorber, which ensures good test<br />
conditions over a wide range of frequencies.<br />
The hot tub was in full operational mode during the emissions<br />
and immunity test, with all pumps and LED lights in<br />
the working position. The pumps were reset to zero every<br />
15 minutes. Functional tests were performed on the tub<br />
before, during and after the tests in order to verify<br />
compliance with the specified performance criteria.<br />
THE RESULTS.<br />
The test shows that the <strong>Viskan</strong> Lindö, on the points tested,<br />
meets the limits for emissions and immunity established<br />
according to EMC Directive compatibility levels. The limit<br />
for maximum permitted emissions (EN 61000-6-3:2007/<br />
A1:2011) is lower than the compatibility level for a particular<br />
electromagnetic interference. In the same way, the limit<br />
for minimum permitted immunity (EN 61000-6-1:2007)<br />
is higher than the compatibility level for a particular<br />
interference.<br />
OUR PROMISE TO YOU AS A VISKAN SPA CUSTOMER.<br />
• To deliver products bearing the CE mark with safe,<br />
interference-free electricity so you can focus fully on<br />
the user experience.<br />
• To be able to provide documentary evidence that our<br />
products have been tested and approved according to<br />
the established requirements for electromagnetic<br />
compatibility within the EU.<br />
• As far as the development of products is concerned we<br />
are and will continue to be at the forefront when it comes<br />
to adaptations according to directives and standards<br />
designed to promote health, safety and the environment.<br />