0<br />

Construction of the meter<br />

Construction of the meter<br />

Construction of the meter<br />

In its standard version, the LE <strong>3000plus</strong> electricity meter consists of three basic elements:<br />

shunt for current measurement in the main circuit,<br />

measuring unit (high-voltage),<br />

communication unit (low-voltage).<br />

The HVM measuring unit of LE<strong>3000plus</strong> is powered only from the 3.3 kV or 660 V DC voltage<br />

being measured. Voltage, current, and energy measurements are performed in the unit.<br />

The LE <strong>3000plus</strong> HVM module is adapted for measurements of both power consumed and power<br />

returned, and at the same time each of the types of power being measured is counted<br />

and recorded separately. For the current measurement, voltage drop at the outer shunt is used,<br />

the shunt being placed in the current main circuit in the plus rail potential.<br />

High-voltage<br />

measuring unit (HVM)<br />

of LE <strong>3000plus</strong><br />

Measuring unit with a measuring shunt<br />

The purpose of the communication unit (KOM) of the LE <strong>3000plus</strong> meter is to process, present<br />

and record the data received from the measuring unit, and to communicate when a remote readout is<br />

needed. The data from the meter may be read locally using a USB port and dedicated software provided<br />

by the manufacturer, or remotely via GPRS transmission (upon user's request) and periodically<br />

to an FTP server.<br />

The communication module is provided with a touch memory reader enabling<br />

identification of the carrier, thus the data from the meter may be used<br />

for settlement of accounts for several electricity consumers at the same time.<br />

The LE KOM module performs also a localization function of rail vehicles, thanks<br />

to an incorporated GPS module. This function is used in cases when a moving<br />

vehicle consumes energy provided by various providers.<br />

LCD display of the LE<strong>3000plus</strong> KOM module presents current values of the voltage and current<br />

being measured as well as power counters' readings, thanks to which the meter is simultaneously<br />

a panel meter for main circuit parameters. Moreover, it is possible to exchange data with other onboard<br />

instruments via CAN or RS-485 interfaces.<br />