29.12.2012 Views

Type C Track Circuit Uninterruptable Power Supply

Type C Track Circuit Uninterruptable Power Supply

Type C Track Circuit Uninterruptable Power Supply

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Instruction<br />

& Maintenance<br />

Model CXP-3<br />

Safetran Systems<br />

<strong>Type</strong> C <strong>Track</strong> <strong>Circuit</strong><br />

<strong>Uninterruptable</strong> <strong>Power</strong> <strong>Supply</strong>


Instruction & Maintenance<br />

<strong>Type</strong> C <strong>Track</strong> <strong>Circuit</strong><br />

<strong>Uninterruptable</strong> <strong>Power</strong> <strong>Supply</strong><br />

Introduction..........................................................................................................................2<br />

Specifications.......................................................................................................................3<br />

Installation............................................................................................................................4<br />

TroubleShooting...................................................................................................................5<br />

Replacement Parts...............................................................................................................6<br />

Schematic.............................................................................................................................7<br />

Notes....................................................................................................................................8<br />

I & M 010350-13<br />

New 2/95<br />

Contents


Model CXP-3 <strong>Type</strong> C <strong>Track</strong> <strong>Circuit</strong><br />

<strong>Uninterruptable</strong> <strong>Power</strong> <strong>Supply</strong><br />

The model CXP-3 <strong>Type</strong> C <strong>Track</strong> <strong>Circuit</strong> <strong>Uninterruptable</strong> <strong>Power</strong> <strong>Supply</strong> (UPS) employs a<br />

track feed transformer, power transfer relay, and standby inverter in a single housing.<br />

The CXP-3 acts as a track feed transformer when the circuit is operated with 115 VAC<br />

input power. In the event of AC power interruption, the CXP-3 converts standby battery<br />

power to an output voltage of the same RMS value as the output under normal<br />

operating conditions. The output voltage is proportional to the input voltage.<br />

The inverter runs in the standby mode. It is turned on by an internal power transfer<br />

relay in the event of the AC input power being lost. The inverter uses rugged MOSFET<br />

power transistors with the highest available current rating. The operating frequency is<br />

kept to within 1 Hz of nominal under any voltage, load, or temperature condition. Surge<br />

protection for the solid state circuitry consists of seven separate stages, including<br />

MOV's, Transorbs, Zeners, inductors and capacitors. All electronics are isolated from<br />

the chassis, giving a 3000 VAC breakdown voltage.<br />

The model CXP-3 is capable of operating up to 4 track circuits through 4 separate<br />

outputs of 6.3 VAC and 3.5 amperes each. Inputs are provided for both 115 VAC<br />

commercial power and 12 VDC standby battery power. The inverter unit is of a high<br />

efficiency design to maximize run time on the battery in the event of power failure.<br />

The model CXP-3 measures 8 inches in height, 5-1/4 inches in width, 9 inches in depth<br />

and weighs 15 pounds. It can be mounted on a standby relay rack, backboard, or shelf.<br />

2


Electrical:<br />

Specifications<br />

Input Current: no load .25A<br />

half load 3.5A<br />

full load 6.5A<br />

Input Voltage: 12.8V<br />

Output Voltage: no load 7.3VAC<br />

half load 6.2VAC<br />

full load 5.6VAC<br />

Output Current: 3.5A Maximum<br />

Efficiency: 1/4 load 70%<br />

half load 89%<br />

Output Wave: Square<br />

Frequency: no load 60.0Hz<br />

half load 60.0Hz<br />

full load 60.0Hz<br />

Physical:<br />

Ambient<br />

Temperature: maximum 159.8° F (71° C)<br />

Dimensions: height 9 inches<br />

width 5-1/4 inches Exclusive of mounting tabs or terminals<br />

depth 9 inches<br />

3


Installation<br />

1. The Model CXP-3 should be rack, wall or shelf mounted within a dry, well ventilated<br />

housing. Four #10 wood screws are provided.<br />

2. Connect the battery to the input terminals being careful to observe the proper polarity.<br />

A buzzing sound should be audible indicating that the inverter is working properly.<br />

Leads between the battery and power supply should be No.9 AWG at minimum and<br />

should be as short as practicable.<br />

3. Measure the AC output voltage across the output terminals. The value read should be<br />

in accordance with the no load specification value. Note that the output voltage will vary<br />

proportionally with the input voltage applied.<br />

4. Connect the load to the output terminals and again measure the AC voltage to make<br />

certain that it is satisfactory.<br />

5. With power off, connect commercial AC power to the CXP-3 unit between terminals BX<br />

and CX as labeled on the cover. Once the power is applied, the internal power transfer<br />

relay will pick up, removing power supplied to the inverter and therefore eliminating the<br />

buzzing sound created by the inverter.<br />

6. Again measure the AC output voltage across the output terminals to make certain that it<br />

is satisfactory.<br />

7. Surge protection for track circuits and AC line should be provided in accordance with<br />

Railroad Standard Practice. See application drawing below for recommended surge<br />

protection.<br />

MODEL 485-28<br />

CLEARVIEW®<br />

LIGHTENING ARRESTER<br />

(#022485-28X)<br />

1T 2T 3T<br />

1TR 2TR 3TR<br />

DC MODEL CXP-3 POWER SUPPLY<br />

115 VAC/12 VDC INPUT<br />

AC<br />

MODEL SP19-2A<br />

SURGE PROTECTION NETWORK<br />

(#010806-3AX)<br />

EQUIPPED WITH A MODEL 700-1<br />

HEAVY DUTY EQUALIZER<br />

(#022700-1X)<br />

4<br />

MODEL SP20-2A<br />

SURGE PROTECTION NETWORK<br />

(#010807-6AX)<br />

EQUIPPED WITH A MODEL 701-1<br />

AC LINE PROTECTOR<br />

(#022701-1X)<br />

MODEL 700-1<br />

HEAVY DUTY EQUALIZER<br />

(#022700-1X)


Trouble Shooting<br />

Trouble encountered with the CXP-3 will generally be contained within the internal solid<br />

state inverter as a result of low or no output. The following causes may be responsible and<br />

steps are outlined to isolate the cause.<br />

1. Low output or loss of output<br />

Check the input to see that it is close to its nominal value. The output AC voltage will<br />

vary directly with the input DC voltage. If a low input voltage is responsible, this<br />

condition must be corrected. Considerable drop in voltage may occur in the leads<br />

between the battery bus and inverter under heavy load conditions. It is for this reason<br />

that heavy gauge wire and short leads are recommended on the input.<br />

2. Excessive or short circuited load<br />

If this cause is suspected, remove the load and measure the no load voltage of this<br />

output. Check to be sure the fuses have not blown. Always replace with fuses of the<br />

same type and rating. This reading should be consistent with the no load specification<br />

values. If the no load conditions are proper, connect the load through an AC ammeter<br />

to see if the drain is excessive. A load current greater than 3.5A per output indicates a<br />

faulty or excessive load. Note that at full load the input current requirement may be as<br />

much as 10.0A. The battery must be kept well charged to insure that input voltage will<br />

be maintained with this load. With a short circuit or very high current load, either fuse<br />

can be blown.<br />

5


Model CXP-3 <strong>Type</strong> C <strong>Track</strong> <strong>Circuit</strong><br />

<strong>Uninterruptable</strong> <strong>Power</strong> <strong>Supply</strong><br />

Replacement Parts<br />

To Order: Specify Description and Part Number<br />

Part Qty.<br />

Description<br />

No. Req'd<br />

Schematic <strong>Power</strong> <strong>Supply</strong> CXP-3 010350-10 1<br />

Side Wrap CXP-3 <strong>Power</strong> <strong>Supply</strong> 010350-9 1<br />

Top Wrap Inverter 010247-9 1<br />

Transformer 88 VA 010247-88 1<br />

Choke Coil #11 Wire 10" Leads 010802-7L 1<br />

Insulating Shield 1-7/16 W/1 Slot 023408-14 2<br />

Insulating Cap 023408-13 2<br />

Fuse Holder 010019-9 2<br />

Fuse 3AG 15 Amp 010350-8 1<br />

Fuse 3AG 1.5 Amp 010350-6 1<br />

Varistor 24 Volt 010900-51 4<br />

Varistor 150 Volt 010900-45 1<br />

PC Board Assembly CXP-3 w/Lead 010247-10X1 1<br />

Wire<br />

Transorb Assembly Unidirectional 010247-16X 1<br />

Relay 120VAC P&B #PM17AY 010350-11 1<br />

Screw Wood RD #10 x 3/4 Stl Zinc 5730-RSC 4<br />

6


Schematic<br />

7


Notes<br />

8


Safetran Systems<br />

Safetran Systems Corporation<br />

4650 Main Street N.E.<br />

Minneapolis, MN 55421<br />

(612) 572-0466