Prior to filming with a freshly loaded magazine always turn the two knurled knobs<br />

(32,35) on the torque motor in the directions indicated by the arrows to remove<br />

excessive film slack in the magazine.<br />

All later model torque motors are equipped<br />

with a grounding plug for a small wire,<br />

which leads directly from the negative pole<br />

of the battery cable to the torque motor.<br />

The most probable cause of torque motor<br />

failure is the lack of sufficiently good<br />

ground contact and the use of this wire is<br />

recommended at all times. Older torque<br />

motors can be retrofitted with this feature.