CATALOG<br />

<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauges</strong><br />

Superior<br />

<strong>Measurement</strong><br />

Systems<br />

www.hmagroup.com.au


<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauges</strong><br />

Case and Bayonet Ring Stainless Steel<br />

Standard (RCh) or Liquid Filled (RChG)<br />

Application<br />

For fluid and gaseous media (compatible to the wetted materials),<br />

which are not highly viscous and do not tend to polymerize, especially<br />

where a sealed case and/or chemical resistance are required.<br />

Nominal Case Sizes (NCS):<br />

Model RCh: 100, 160, 250 mm (4", 6", 10")<br />

Model RChG: 100, 160 mm (4", 6")<br />

Accuracy Class (EN 837-1)<br />

1.0 (i.e. + 1.0% f.s.)<br />

<strong>Pressure</strong> Ranges (EN 837-1)<br />

Version – 1*: 0-0.6 to 0-1000 bar, 0-10 to 0-15,000 psi<br />

Version – 2*: 0-1600 bar, 0-20,000 psi<br />

Version – 3*: 0-0.6 to 0-1600 bar, 0-10 to 0-20,000 psi<br />

also corresponding vacuum and compound pressure ranges<br />

(*see below)<br />

<strong>Pressure</strong> Limitations<br />

Steady pressure: full scale value<br />

Cyclic pressure: 90% of full scale value<br />

Overpressure: 130% of full scale value<br />

Protection Type (EN 60 529 / IEC 529)<br />

Model RCh = IP 54 / Model RChG = IP 65<br />

Further information about advantages, applications, specifications, temperature<br />

limitations and pressure ranges of <strong>Bourdon</strong> tube pressure gauges, accuracy classes<br />

1.0 and 1.6 according to EN, can be found on general information leaflet 1000.<br />

Standard Configuration<br />

Process Connection<br />

G ½ B (½" BSP) bottom connection, optionally: lower back (r)<br />

Wetted Parts<br />

Ordering code –1: Socket: brass<br />

<strong>Bourdon</strong> tube: < 40 bar = bronze, C-form,<br />

(< 800 psi) soft soldered<br />

> 60 bar = 316 Ti (1.4571),<br />

(>1,000 psi) helical, silver brazed<br />

Ordering codel –2: Socket 2) : 316 Ti stainless steel (1.4571)<br />

<strong>Bourdon</strong> tube: alloy steel, helical, argon arc welded<br />

Ordering code –3: Socket 2) : 316 Ti stainless steel (1.4571)<br />

<strong>Bourdon</strong> tube: argon arc welded,<br />

< 40 bar = 316 Ti (1.4571),<br />

(< 800 psi) C-form<br />

> 60 bar = 316 Ti (1.4571),<br />

(>1,000 psi) 3) helical ,<br />

1600 bar = NiFe-alloy, helical 3) ,<br />

(20,000 psi)<br />

Movement<br />

Version –1 = brass/German silver; – 2 and –3 = stainless steel<br />

Dial:<br />

Aluminum alloy, black figures, white background<br />

Pointer:<br />

Aluminum black<br />

Case and Ring<br />

304 stainless steel (1.4301), bayonet ring<br />

Window<br />

Version –1: single strength glass, –2 and – 3: laminated safety glass<br />

Case Filling<br />

Model RChG only: Glycerine<br />

Safety Features<br />

RCh: 1" Blow-out (Ø 25 mm) in the back of the case<br />

RChG 100: Blow-out Ø 40 mm (~ 1.57") in the back of the case,<br />

with pressure equalizing membrane<br />

RChG 160: Top blow-out device<br />

ARMATURENBAU GmbH<br />

Manometerstraße 5 D-46487 Wesel - Ginderich<br />

Phone: (0 28 03) 91 30–0 Fax: (0 28 03) 10 35<br />

armaturenbau.com mail@armaturenbau.com<br />

How to Order:<br />

NCS 100 mm (4")<br />

160 mm (6")<br />

250 mm (10")<br />

Accuracy Class 1.0<br />

RCh<br />

RChG<br />

Model code: RCh (no case filling, IP 54)<br />

RChG (filled case, IP 65)<br />

RCh(G) (fillable case, IP 65)<br />

Nominal case size: 100, 160, 250<br />

Wetted parts: – 1, – 2 or – 3 (see left side)<br />

Case configuration: r, Rh, rRh, Fr, rFr, rBFr<br />

(compare overleaf) (standard case = bottom connection =<br />

without additional code letter)<br />

<strong>Pressure</strong> range: according to EN 837-1<br />

e.g. 0 - 4 bar or 0-60 bar<br />

Process connection: G ½ B (½" BSP, standard) or ½" NPT<br />

(others: see above)<br />

Special options: (see above)<br />

Examples for Ordering Information:<br />

RCh 100–3 rFr, 0-6 bar, G ½ B (or ½" BSP)<br />

RChG 160–1, -1/+9 bar, ½" NPT<br />

Models<br />

Special Options<br />

Wetted parts monel = ordering code: – 6:<br />

pressure ranges 0-0.6 to 0-600 bar and 0-10 psi to 0-10,000 psi,<br />

<strong>Bourdon</strong> tube argon arc welded, stainless steel movement<br />

Process connection M 20 x 1.5, ½" NPT, G ¼ B, ¼"NPT, highpressure<br />

connections; others upon request<br />

Inlet port restrictor screw brass, stainless steel, or monel<br />

<strong>Pressure</strong> ranges 0-2500 bar, 0-30,000 psi, 0-35,000 psi, version<br />

–2 or –3, pressure limitation at steady pressure: full scale value, at cyclic<br />

pressure: 65% of full span, HP-connection with M16x1.5 female and<br />

sealing cone for ¼" pipe; optionally with 9/16–18 UNF female or<br />

9/16–18 UNF (left) male; others upon request<br />

Special scales, such as dual ranges, special units, fine division<br />

(with knife edge pointer) etc.<br />

Refrigerant gauge, see technical info. sheet T01-000-015<br />

Receiver gauges 0.2-1 bar or 3-15 psi<br />

Micro-adjustable pointer, mechanism aluminum<br />

Stationary red pointer on the dial<br />

Maximum-indicating pointer (pressure ranges > 0-2.5 bar) or<br />

stationary red pointer with external adjustment, acrylic glass resp.<br />

polycarbonate lens<br />

Other than vertical installation; top or side connection<br />

NCS 100 or 160 (4", 6") for higher temperatures<br />

Other case fillings, e.g. silicone oil for low temperatures down to<br />

-40 °C and others upon request<br />

Electrical accessories, see data sheets 1291 and 9000 ff<br />

Subsidiary Company and Sales East Germany and Eastern Europe<br />

MANOTHERM Beierfeld GmbH<br />

Am Gewerbepark 9 D-08344 Grünhain-Beierfeld<br />

Phone: (0 37 74) 58–0 Fax: (0 37 74) 58–545<br />

manotherm.com mail@manotherm.com<br />

1201<br />

9/05


Case Configuration, Code Letters, Dimensional Data and Weight<br />

Bottom connection,<br />

without code letter<br />

Bottom connection, front mounting flange 2) ,<br />

code letters: Fr<br />

Lower back connection,<br />

code letter: r<br />

Dry case version, model RCh: Filled case version, model RChG:<br />

Front flange with longholes attached to the Mounting brackets welded to the case,<br />

case, and a separate cover front flange and a separate front flange<br />

Model RCh 160 (dry version) only: Nominal size 100 according data sheet 1202 only:<br />

Lower back connection, Lower back connection,<br />

U-clamp for panel mounting, U-clamp for panel mounting, crimped-on ring,<br />

code letters: rBFr Model: RChg resp. RChgG 100... rBFr<br />

(not available with laminated safety glass)<br />

D imensional<br />

Data<br />

( mm<br />

/ i nches)<br />

a nd<br />

Weight<br />

( kg<br />

/ l b)<br />

1) RCh 250 with mtg. brackets welded to the case 2) not with nom. size 250 3) optional M 20 x 1,5<br />

The information in this leaflet is given in good faith, but we reserve the right to make changes without notice.<br />

Bottom connection, Lower back connection,<br />

rear mounting flange 1) , rear mounting flange 2) ,<br />

code letters: Rh code letters: rRh<br />

Lower back connection, front mounting flange 2) ,<br />

code letters: rFr<br />

Dry case version, model RCh:<br />

Front flange with longholes<br />

attached to the case and<br />

a separate cover front flange<br />

Filled case version, model RChG:<br />

Mounting brackets welded to the<br />

case, and a separate front flange<br />

Safety blow-outs:<br />

Model RChG 160:<br />

Top blow-out device<br />

Models RCh 100, 160, 250:<br />

Blow-out Ø 1" (25,4 mm)<br />

Model RChG 100:<br />

Blow-out Ø 40 mm (~1.57")<br />

NCS a a1 b b1 c c1 c2 c3 D D1 d1 d2 d3 e g g1<br />

100 20 23. 5 55 58.<br />

5<br />

101 106 116 132 4. 8 30 97 96<br />

4" . 79<br />

. 93<br />

2. 17<br />

2. 30<br />

3. 98<br />

4. 17<br />

4. 57<br />

5. 20<br />

. 19<br />

1. 18<br />

3. 82<br />

3.<br />

78<br />

160<br />

1951 54 6 3 20 19<br />

161 167 178 196<br />

92. 5 91.<br />

5<br />

6" 15.<br />

5 . 75<br />

2. 01<br />

2. 13<br />

. 24<br />

. 12<br />

. 79<br />

. 75<br />

6. 34<br />

6. 57<br />

7. 08<br />

7. 72<br />

5. 8 52<br />

3. 64<br />

3.<br />

60<br />

250 10" . 61<br />

17. 5<br />

. 69<br />

58 2. 28<br />

60 2. 36<br />

251<br />

9. 88<br />

—<br />

270 10. 63<br />

285 11. 22<br />

. 23<br />

2. 05<br />

97 3. 82<br />

96<br />

3.<br />

78<br />

NCS G G1 h h1 s s1 s2 s3 s4 SW SW1<br />

Weight<br />

( approx)<br />

RCh RChG<br />

100<br />

8784 10<br />

. 60<br />

. 95<br />

4" 3. 43<br />

3. 31<br />

2 6 6 1 . 39<br />

1. 30<br />

2.<br />

10<br />

160 6" 3)<br />

G ½ B<br />

½" BPS<br />

½"<br />

NPT<br />

115 4. 53<br />

114 4. 49<br />

. 08<br />

. 24<br />

. 24<br />

. 04<br />

—<br />

22 . 87<br />

17<br />

. 67<br />

1. 10<br />

2. 40<br />

1.<br />

95<br />

4.<br />

30<br />

250 10" 165 6. 50<br />

164<br />

6. 46<br />

—<br />

2<br />

. 08<br />

— — —<br />

2.<br />

10<br />

4.<br />

60<br />

—<br />

1201 - 9/05 P. 2 of 2 ARMATURENBAU GmbH, D-46487 Wesel-Ginderich, Tel. +49(0)2803/9130–0, mail@armaturenbau.com MANOTHERM Beierfeld GmbH, D-08344 Grünhain-Beierfeld, Tel. +49(0)3774/58–0, mail@manotherm.com


NSW<br />

NSW<br />

Sydney<br />

13<br />

Wyong<br />

Sirius<br />

-<br />

Road,<br />

Head<br />

Lane<br />

Office<br />

Cove NSW 2066<br />

Tel:<br />

10 Hereford<br />

+61 (0)2<br />

Street,<br />

9428 7377<br />

Berkeley Vale NSW 2261<br />

Fax:<br />

PO Box<br />

+61<br />

5010<br />

(0)2 9428<br />

Chittaway<br />

7379<br />

NSW 2261<br />

Email:<br />

Tel: +61<br />

sydney@hmagroup.com.au<br />

(0)2 4389 6191<br />

Fax:+ 61 (0)2 4389 6199<br />

Wyong Email: info@hmagroup.com.au<br />

- Head Office<br />

10 Hereford Street, Berkeley Vale NSW 2261<br />

PO<br />

Artarmon<br />

Box 5010 Chittaway NSW 2261<br />

Tel:<br />

48 Whiting<br />

+61 (0)2<br />

Street,<br />

4389<br />

Artarmon<br />

6191<br />

NSW 2064<br />

Fax:<br />

PO Box<br />

+61<br />

177,<br />

(0)2<br />

Artarmon<br />

4389 6199<br />

NSW 2064<br />

Email:<br />

Tel:+61<br />

info@hmagroup.com.au<br />

(0)2 9432 7300<br />

Fax: +61 (0)2 9432 7399<br />

Email: artarmon@hmagroup.com.au<br />

QLD<br />

Brisbane Gladesville<br />

4rd 33-37 Floor, College 49 Sherwood Street, Gladesville Road, Toowong NSW 2111 QLD 4066<br />

PO Tel: Box +61 106, (0)2 Toowong 9816 3377 QLD 4066<br />

Tel: Fax: +61 +61 (0)7 (0)2 3859 9816 6800 3806<br />

Fax: gladesville@hmagroup.com.au<br />

+61 (0)7 3859 6869<br />

Email: brisbane@hmagroup.com.au<br />

Vic<br />

Mackay<br />

Melbourne<br />

22-30 Southgate Drive,<br />

PO Box 647, Morwell VIC 3840<br />

Southgate Industrial Park, Paget QLD 4740<br />

Tel:+ 61 (0)3 5136 8445<br />

PO Box 6221, Mackay Mail Centre QLD 4741<br />

Mobile: +61 (0)429 176 688<br />

Tel: +61 (0)7 4998 6900<br />

Email: melbourne@hmagroup.com.au<br />

Fax: +61 (0)7 4998 6999<br />

Email: Morwell mackay@hmagroup.com.au<br />

8 Jones Road, Morwell VIC 3840<br />

Gladstone<br />

PO Box 647, Morwell VIC 3840<br />

9 Neil Street, Gladstone QLD 4680<br />

Tel:+ 61 (0)3 5136 8400<br />

PO Box 1731, Gladstone QLD 4680<br />

Fax: +61 (0)3 5136 8499<br />

Tel: +61 (0)7 4978 3128<br />

Email: morwell@hmagroup.com.au<br />

Fax: +61 (0)7 4978 3127<br />

Email: gladstone@hmagroup.com.au<br />

SA<br />

Townsville<br />

Adelaide<br />

PO<br />

PO<br />

Box<br />

Box<br />

347,<br />

1280,<br />

Aitkenvale<br />

North Haven<br />

QLD<br />

SA<br />

4814<br />

5018<br />

Tel:<br />

Tel: +61<br />

+61<br />

(0)8<br />

(0)7<br />

8341<br />

4728<br />

8067<br />

6300<br />

Fax:<br />

Fax:<br />

+61<br />

+61<br />

(0)7<br />

(0)8<br />

4728<br />

8341<br />

6388<br />

8067<br />

Mobile:<br />

Mobile:<br />

+61<br />

+61<br />

(0)417<br />

(0)437<br />

996<br />

460<br />

694<br />

032<br />

Email:<br />

Email:<br />

townsville@hmagroup.com.au<br />

adelaide@hmagroup.com.au<br />

WA<br />

WA<br />

Perth<br />

Perth<br />

119 Dowd Street, Welshpool WA 6106<br />

Unit 1, 34 Ledgar Road, Balcatta WA 6021<br />

Tel: +61 (0)8 6254 9500<br />

Tel: +61 (0)8 9345 3688<br />

Fax: +61 (0)8 6254 9599<br />

Fax:+61 (0)8 9344 8707<br />

Email: perth@hmagroup.com.au<br />

Email: perth@hmagroup.com.au<br />

01/11 HM086<br />

VIC<br />

QLD<br />

Melbourne<br />

PO Brisbane Box 204, Narre Warren VIC 3805<br />

Mobile: 4th Floor, +61 49 (0)429 Sherwood 176 688Road,<br />

Toowong QLD 4066<br />

Email: PO Box melbourne@hmagroup.com.au<br />

106, Toowong QLD 4066<br />

Tel: +61 (0)7 3859 6800<br />

Morwell<br />

Fax: +61 (0)7 3859 6869<br />

8 Jones Road, Morwell VIC 3840<br />

Email: brisbane@hmagroup.com.au<br />

PO Box 647, Morwell VIC 3840<br />

Tel: Mackay + 61 (0)3 5136 8400<br />

Fax: 22-30 +61 Southgate (0)3 5136 Drive, 8499<br />

Email: Southgate morwell@hmagroup.com.au<br />

Industrial Park, Paget QLD 4740<br />

PO Box 6221, Mackay Mail Centre QLD 4741<br />

SA Tel: +61 (0)7 4998 6900<br />

Fax:+61 (0)7 4998 6999<br />

Adelaide<br />

Email: mackay@hmagroup.com.au<br />

PO Box 1280, North Haven SA 5018<br />

Tel: Gladstone +61 (0)8 8341 8067<br />

Fax: 9 Neil +61 St, (0)8 Gladstone 8341 8067 QLD 4680<br />

Mobile: PO Box +61 1731, (0)437 Gladstone 460 032QLD<br />

4680<br />

Email: Tel: +61 adelaide@hmagroup.com.au<br />

(0)7 4978 3128<br />

Fax: +61 (0)7 4978 3127<br />

Email: gladstone@hmagroup.com.au<br />

NEW ZEALAND<br />

Hamilton Townsville<br />

Unit PO 14, Box 9 347, Karewa Aitkenvale Place, Pukete, QLD 4814 Hamilton NZ 3200<br />

PO Tel: Box +61 10102, (0)7 4728 Te Rapa, 6300 Hamilton NZ 3241<br />

Tel: Fax: +64 +61 (0)7 (0)7 847 4728 1880 6388<br />

Fax: Mobile: +64 (0)7 +61 847 (0)417 1883 996 694<br />

Email: hamilton@hmagroup.co.nz<br />

townsville@hmagroup.com.au<br />

Wellington<br />

NEW zEALAND<br />

Tel: +64 (0)7 847 1880<br />

Fax: Hamilton +64 (0)7 847 1883<br />

Mobile: PO Box +64 89, 272 Ngaruawahia 612 744 3720 New Zealand<br />

Email: Tel: +64 wellington@hmagroup.co.nz<br />

(0)7 824 5040<br />

Fax: +64 (0)7 824 5041<br />

Dunedin<br />

Email: hamilton@hmagroup.co.nz<br />

Tel: +64 (0)27 511 6694<br />

Fax: Wellington +64 (0)7 847 1883<br />

Email: PO Box dunedin@hmagroup.co.nz<br />

13104, Johnsonville 6037 Wellington New Zealand<br />

Tel: +64 (0)4 891 0312<br />

Fax: +64 (0)4 891 0313<br />

Email: wellington@hmagroup.co.nz<br />

Halley & Mellowes Australasia Group of Companies

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!