CATALOG<br />
<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauges</strong><br />
Superior<br />
<strong>Measurement</strong><br />
Systems<br />
www.hmagroup.com.au
<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauges</strong><br />
Case and Bayonet Ring Stainless Steel<br />
Standard (RCh) or Liquid Filled (RChG)<br />
Application<br />
For fluid and gaseous media (compatible to the wetted materials),<br />
which are not highly viscous and do not tend to polymerize, especially<br />
where a sealed case and/or chemical resistance are required.<br />
Nominal Case Sizes (NCS):<br />
Model RCh: 100, 160, 250 mm (4", 6", 10")<br />
Model RChG: 100, 160 mm (4", 6")<br />
Accuracy Class (EN 837-1)<br />
1.0 (i.e. + 1.0% f.s.)<br />
<strong>Pressure</strong> Ranges (EN 837-1)<br />
Version – 1*: 0-0.6 to 0-1000 bar, 0-10 to 0-15,000 psi<br />
Version – 2*: 0-1600 bar, 0-20,000 psi<br />
Version – 3*: 0-0.6 to 0-1600 bar, 0-10 to 0-20,000 psi<br />
also corresponding vacuum and compound pressure ranges<br />
(*see below)<br />
<strong>Pressure</strong> Limitations<br />
Steady pressure: full scale value<br />
Cyclic pressure: 90% of full scale value<br />
Overpressure: 130% of full scale value<br />
Protection Type (EN 60 529 / IEC 529)<br />
Model RCh = IP 54 / Model RChG = IP 65<br />
Further information about advantages, applications, specifications, temperature<br />
limitations and pressure ranges of <strong>Bourdon</strong> tube pressure gauges, accuracy classes<br />
1.0 and 1.6 according to EN, can be found on general information leaflet 1000.<br />
Standard Configuration<br />
Process Connection<br />
G ½ B (½" BSP) bottom connection, optionally: lower back (r)<br />
Wetted Parts<br />
Ordering code –1: Socket: brass<br />
<strong>Bourdon</strong> tube: < 40 bar = bronze, C-form,<br />
(< 800 psi) soft soldered<br />
> 60 bar = 316 Ti (1.4571),<br />
(>1,000 psi) helical, silver brazed<br />
Ordering codel –2: Socket 2) : 316 Ti stainless steel (1.4571)<br />
<strong>Bourdon</strong> tube: alloy steel, helical, argon arc welded<br />
Ordering code –3: Socket 2) : 316 Ti stainless steel (1.4571)<br />
<strong>Bourdon</strong> tube: argon arc welded,<br />
< 40 bar = 316 Ti (1.4571),<br />
(< 800 psi) C-form<br />
> 60 bar = 316 Ti (1.4571),<br />
(>1,000 psi) 3) helical ,<br />
1600 bar = NiFe-alloy, helical 3) ,<br />
(20,000 psi)<br />
Movement<br />
Version –1 = brass/German silver; – 2 and –3 = stainless steel<br />
Dial:<br />
Aluminum alloy, black figures, white background<br />
Pointer:<br />
Aluminum black<br />
Case and Ring<br />
304 stainless steel (1.4301), bayonet ring<br />
Window<br />
Version –1: single strength glass, –2 and – 3: laminated safety glass<br />
Case Filling<br />
Model RChG only: Glycerine<br />
Safety Features<br />
RCh: 1" Blow-out (Ø 25 mm) in the back of the case<br />
RChG 100: Blow-out Ø 40 mm (~ 1.57") in the back of the case,<br />
with pressure equalizing membrane<br />
RChG 160: Top blow-out device<br />
ARMATURENBAU GmbH<br />
Manometerstraße 5 D-46487 Wesel - Ginderich<br />
Phone: (0 28 03) 91 30–0 Fax: (0 28 03) 10 35<br />
armaturenbau.com mail@armaturenbau.com<br />
How to Order:<br />
NCS 100 mm (4")<br />
160 mm (6")<br />
250 mm (10")<br />
Accuracy Class 1.0<br />
RCh<br />
RChG<br />
Model code: RCh (no case filling, IP 54)<br />
RChG (filled case, IP 65)<br />
RCh(G) (fillable case, IP 65)<br />
Nominal case size: 100, 160, 250<br />
Wetted parts: – 1, – 2 or – 3 (see left side)<br />
Case configuration: r, Rh, rRh, Fr, rFr, rBFr<br />
(compare overleaf) (standard case = bottom connection =<br />
without additional code letter)<br />
<strong>Pressure</strong> range: according to EN 837-1<br />
e.g. 0 - 4 bar or 0-60 bar<br />
Process connection: G ½ B (½" BSP, standard) or ½" NPT<br />
(others: see above)<br />
Special options: (see above)<br />
Examples for Ordering Information:<br />
RCh 100–3 rFr, 0-6 bar, G ½ B (or ½" BSP)<br />
RChG 160–1, -1/+9 bar, ½" NPT<br />
Models<br />
Special Options<br />
Wetted parts monel = ordering code: – 6:<br />
pressure ranges 0-0.6 to 0-600 bar and 0-10 psi to 0-10,000 psi,<br />
<strong>Bourdon</strong> tube argon arc welded, stainless steel movement<br />
Process connection M 20 x 1.5, ½" NPT, G ¼ B, ¼"NPT, highpressure<br />
connections; others upon request<br />
Inlet port restrictor screw brass, stainless steel, or monel<br />
<strong>Pressure</strong> ranges 0-2500 bar, 0-30,000 psi, 0-35,000 psi, version<br />
–2 or –3, pressure limitation at steady pressure: full scale value, at cyclic<br />
pressure: 65% of full span, HP-connection with M16x1.5 female and<br />
sealing cone for ¼" pipe; optionally with 9/16–18 UNF female or<br />
9/16–18 UNF (left) male; others upon request<br />
Special scales, such as dual ranges, special units, fine division<br />
(with knife edge pointer) etc.<br />
Refrigerant gauge, see technical info. sheet T01-000-015<br />
Receiver gauges 0.2-1 bar or 3-15 psi<br />
Micro-adjustable pointer, mechanism aluminum<br />
Stationary red pointer on the dial<br />
Maximum-indicating pointer (pressure ranges > 0-2.5 bar) or<br />
stationary red pointer with external adjustment, acrylic glass resp.<br />
polycarbonate lens<br />
Other than vertical installation; top or side connection<br />
NCS 100 or 160 (4", 6") for higher temperatures<br />
Other case fillings, e.g. silicone oil for low temperatures down to<br />
-40 °C and others upon request<br />
Electrical accessories, see data sheets 1291 and 9000 ff<br />
Subsidiary Company and Sales East Germany and Eastern Europe<br />
MANOTHERM Beierfeld GmbH<br />
Am Gewerbepark 9 D-08344 Grünhain-Beierfeld<br />
Phone: (0 37 74) 58–0 Fax: (0 37 74) 58–545<br />
manotherm.com mail@manotherm.com<br />
1201<br />
9/05
Case Configuration, Code Letters, Dimensional Data and Weight<br />
Bottom connection,<br />
without code letter<br />
Bottom connection, front mounting flange 2) ,<br />
code letters: Fr<br />
Lower back connection,<br />
code letter: r<br />
Dry case version, model RCh: Filled case version, model RChG:<br />
Front flange with longholes attached to the Mounting brackets welded to the case,<br />
case, and a separate cover front flange and a separate front flange<br />
Model RCh 160 (dry version) only: Nominal size 100 according data sheet 1202 only:<br />
Lower back connection, Lower back connection,<br />
U-clamp for panel mounting, U-clamp for panel mounting, crimped-on ring,<br />
code letters: rBFr Model: RChg resp. RChgG 100... rBFr<br />
(not available with laminated safety glass)<br />
D imensional<br />
Data<br />
( mm<br />
/ i nches)<br />
a nd<br />
Weight<br />
( kg<br />
/ l b)<br />
1) RCh 250 with mtg. brackets welded to the case 2) not with nom. size 250 3) optional M 20 x 1,5<br />
The information in this leaflet is given in good faith, but we reserve the right to make changes without notice.<br />
Bottom connection, Lower back connection,<br />
rear mounting flange 1) , rear mounting flange 2) ,<br />
code letters: Rh code letters: rRh<br />
Lower back connection, front mounting flange 2) ,<br />
code letters: rFr<br />
Dry case version, model RCh:<br />
Front flange with longholes<br />
attached to the case and<br />
a separate cover front flange<br />
Filled case version, model RChG:<br />
Mounting brackets welded to the<br />
case, and a separate front flange<br />
Safety blow-outs:<br />
Model RChG 160:<br />
Top blow-out device<br />
Models RCh 100, 160, 250:<br />
Blow-out Ø 1" (25,4 mm)<br />
Model RChG 100:<br />
Blow-out Ø 40 mm (~1.57")<br />
NCS a a1 b b1 c c1 c2 c3 D D1 d1 d2 d3 e g g1<br />
100 20 23. 5 55 58.<br />
5<br />
101 106 116 132 4. 8 30 97 96<br />
4" . 79<br />
. 93<br />
2. 17<br />
2. 30<br />
3. 98<br />
4. 17<br />
4. 57<br />
5. 20<br />
. 19<br />
1. 18<br />
3. 82<br />
3.<br />
78<br />
160<br />
1951 54 6 3 20 19<br />
161 167 178 196<br />
92. 5 91.<br />
5<br />
6" 15.<br />
5 . 75<br />
2. 01<br />
2. 13<br />
. 24<br />
. 12<br />
. 79<br />
. 75<br />
6. 34<br />
6. 57<br />
7. 08<br />
7. 72<br />
5. 8 52<br />
3. 64<br />
3.<br />
60<br />
250 10" . 61<br />
17. 5<br />
. 69<br />
58 2. 28<br />
60 2. 36<br />
251<br />
9. 88<br />
—<br />
270 10. 63<br />
285 11. 22<br />
. 23<br />
2. 05<br />
97 3. 82<br />
96<br />
3.<br />
78<br />
NCS G G1 h h1 s s1 s2 s3 s4 SW SW1<br />
Weight<br />
( approx)<br />
RCh RChG<br />
100<br />
8784 10<br />
. 60<br />
. 95<br />
4" 3. 43<br />
3. 31<br />
2 6 6 1 . 39<br />
1. 30<br />
2.<br />
10<br />
160 6" 3)<br />
G ½ B<br />
½" BPS<br />
½"<br />
NPT<br />
115 4. 53<br />
114 4. 49<br />
. 08<br />
. 24<br />
. 24<br />
. 04<br />
—<br />
22 . 87<br />
17<br />
. 67<br />
1. 10<br />
2. 40<br />
1.<br />
95<br />
4.<br />
30<br />
250 10" 165 6. 50<br />
164<br />
6. 46<br />
—<br />
2<br />
. 08<br />
— — —<br />
2.<br />
10<br />
4.<br />
60<br />
—<br />
1201 - 9/05 P. 2 of 2 ARMATURENBAU GmbH, D-46487 Wesel-Ginderich, Tel. +49(0)2803/9130–0, mail@armaturenbau.com MANOTHERM Beierfeld GmbH, D-08344 Grünhain-Beierfeld, Tel. +49(0)3774/58–0, mail@manotherm.com
NSW<br />
NSW<br />
Sydney<br />
13<br />
Wyong<br />
Sirius<br />
-<br />
Road,<br />
Head<br />
Lane<br />
Office<br />
Cove NSW 2066<br />
Tel:<br />
10 Hereford<br />
+61 (0)2<br />
Street,<br />
9428 7377<br />
Berkeley Vale NSW 2261<br />
Fax:<br />
PO Box<br />
+61<br />
5010<br />
(0)2 9428<br />
Chittaway<br />
7379<br />
NSW 2261<br />
Email:<br />
Tel: +61<br />
sydney@hmagroup.com.au<br />
(0)2 4389 6191<br />
Fax:+ 61 (0)2 4389 6199<br />
Wyong Email: info@hmagroup.com.au<br />
- Head Office<br />
10 Hereford Street, Berkeley Vale NSW 2261<br />
PO<br />
Artarmon<br />
Box 5010 Chittaway NSW 2261<br />
Tel:<br />
48 Whiting<br />
+61 (0)2<br />
Street,<br />
4389<br />
Artarmon<br />
6191<br />
NSW 2064<br />
Fax:<br />
PO Box<br />
+61<br />
177,<br />
(0)2<br />
Artarmon<br />
4389 6199<br />
NSW 2064<br />
Email:<br />
Tel:+61<br />
info@hmagroup.com.au<br />
(0)2 9432 7300<br />
Fax: +61 (0)2 9432 7399<br />
Email: artarmon@hmagroup.com.au<br />
QLD<br />
Brisbane Gladesville<br />
4rd 33-37 Floor, College 49 Sherwood Street, Gladesville Road, Toowong NSW 2111 QLD 4066<br />
PO Tel: Box +61 106, (0)2 Toowong 9816 3377 QLD 4066<br />
Tel: Fax: +61 +61 (0)7 (0)2 3859 9816 6800 3806<br />
Fax: gladesville@hmagroup.com.au<br />
+61 (0)7 3859 6869<br />
Email: brisbane@hmagroup.com.au<br />
Vic<br />
Mackay<br />
Melbourne<br />
22-30 Southgate Drive,<br />
PO Box 647, Morwell VIC 3840<br />
Southgate Industrial Park, Paget QLD 4740<br />
Tel:+ 61 (0)3 5136 8445<br />
PO Box 6221, Mackay Mail Centre QLD 4741<br />
Mobile: +61 (0)429 176 688<br />
Tel: +61 (0)7 4998 6900<br />
Email: melbourne@hmagroup.com.au<br />
Fax: +61 (0)7 4998 6999<br />
Email: Morwell mackay@hmagroup.com.au<br />
8 Jones Road, Morwell VIC 3840<br />
Gladstone<br />
PO Box 647, Morwell VIC 3840<br />
9 Neil Street, Gladstone QLD 4680<br />
Tel:+ 61 (0)3 5136 8400<br />
PO Box 1731, Gladstone QLD 4680<br />
Fax: +61 (0)3 5136 8499<br />
Tel: +61 (0)7 4978 3128<br />
Email: morwell@hmagroup.com.au<br />
Fax: +61 (0)7 4978 3127<br />
Email: gladstone@hmagroup.com.au<br />
SA<br />
Townsville<br />
Adelaide<br />
PO<br />
PO<br />
Box<br />
Box<br />
347,<br />
1280,<br />
Aitkenvale<br />
North Haven<br />
QLD<br />
SA<br />
4814<br />
5018<br />
Tel:<br />
Tel: +61<br />
+61<br />
(0)8<br />
(0)7<br />
8341<br />
4728<br />
8067<br />
6300<br />
Fax:<br />
Fax:<br />
+61<br />
+61<br />
(0)7<br />
(0)8<br />
4728<br />
8341<br />
6388<br />
8067<br />
Mobile:<br />
Mobile:<br />
+61<br />
+61<br />
(0)417<br />
(0)437<br />
996<br />
460<br />
694<br />
032<br />
Email:<br />
Email:<br />
townsville@hmagroup.com.au<br />
adelaide@hmagroup.com.au<br />
WA<br />
WA<br />
Perth<br />
Perth<br />
119 Dowd Street, Welshpool WA 6106<br />
Unit 1, 34 Ledgar Road, Balcatta WA 6021<br />
Tel: +61 (0)8 6254 9500<br />
Tel: +61 (0)8 9345 3688<br />
Fax: +61 (0)8 6254 9599<br />
Fax:+61 (0)8 9344 8707<br />
Email: perth@hmagroup.com.au<br />
Email: perth@hmagroup.com.au<br />
01/11 HM086<br />
VIC<br />
QLD<br />
Melbourne<br />
PO Brisbane Box 204, Narre Warren VIC 3805<br />
Mobile: 4th Floor, +61 49 (0)429 Sherwood 176 688Road,<br />
Toowong QLD 4066<br />
Email: PO Box melbourne@hmagroup.com.au<br />
106, Toowong QLD 4066<br />
Tel: +61 (0)7 3859 6800<br />
Morwell<br />
Fax: +61 (0)7 3859 6869<br />
8 Jones Road, Morwell VIC 3840<br />
Email: brisbane@hmagroup.com.au<br />
PO Box 647, Morwell VIC 3840<br />
Tel: Mackay + 61 (0)3 5136 8400<br />
Fax: 22-30 +61 Southgate (0)3 5136 Drive, 8499<br />
Email: Southgate morwell@hmagroup.com.au<br />
Industrial Park, Paget QLD 4740<br />
PO Box 6221, Mackay Mail Centre QLD 4741<br />
SA Tel: +61 (0)7 4998 6900<br />
Fax:+61 (0)7 4998 6999<br />
Adelaide<br />
Email: mackay@hmagroup.com.au<br />
PO Box 1280, North Haven SA 5018<br />
Tel: Gladstone +61 (0)8 8341 8067<br />
Fax: 9 Neil +61 St, (0)8 Gladstone 8341 8067 QLD 4680<br />
Mobile: PO Box +61 1731, (0)437 Gladstone 460 032QLD<br />
4680<br />
Email: Tel: +61 adelaide@hmagroup.com.au<br />
(0)7 4978 3128<br />
Fax: +61 (0)7 4978 3127<br />
Email: gladstone@hmagroup.com.au<br />
NEW ZEALAND<br />
Hamilton Townsville<br />
Unit PO 14, Box 9 347, Karewa Aitkenvale Place, Pukete, QLD 4814 Hamilton NZ 3200<br />
PO Tel: Box +61 10102, (0)7 4728 Te Rapa, 6300 Hamilton NZ 3241<br />
Tel: Fax: +64 +61 (0)7 (0)7 847 4728 1880 6388<br />
Fax: Mobile: +64 (0)7 +61 847 (0)417 1883 996 694<br />
Email: hamilton@hmagroup.co.nz<br />
townsville@hmagroup.com.au<br />
Wellington<br />
NEW zEALAND<br />
Tel: +64 (0)7 847 1880<br />
Fax: Hamilton +64 (0)7 847 1883<br />
Mobile: PO Box +64 89, 272 Ngaruawahia 612 744 3720 New Zealand<br />
Email: Tel: +64 wellington@hmagroup.co.nz<br />
(0)7 824 5040<br />
Fax: +64 (0)7 824 5041<br />
Dunedin<br />
Email: hamilton@hmagroup.co.nz<br />
Tel: +64 (0)27 511 6694<br />
Fax: Wellington +64 (0)7 847 1883<br />
Email: PO Box dunedin@hmagroup.co.nz<br />
13104, Johnsonville 6037 Wellington New Zealand<br />
Tel: +64 (0)4 891 0312<br />
Fax: +64 (0)4 891 0313<br />
Email: wellington@hmagroup.co.nz<br />
Halley & Mellowes Australasia Group of Companies