For homogenising the spiked water, a pump with multiple outlets was used to mix the water<br />

in a tank <strong>of</strong> 600 litre. The homogenised spiked water was bottled in 500 ml portions in<br />

appropriate plastic bottles. The total mass <strong>of</strong> the bottle with the label was registered for<br />

further control. Three water sample portions at 100 g were analysed by gamma spectrometry.<br />

The relative standard deviation <strong>of</strong> each analyte was calculated. It was found that the relative<br />

standard deviations <strong>of</strong> all analytes were below the method repeatability relative standard<br />

deviation, which demonstrates satisfactory homogeneity <strong>of</strong> the water sample.<br />

Table 2 lists the target values and the associated combined uncertainty in the water samples.<br />

TABLE 1. IDENTIFICATION OF THE CERTIFIED SOLUTIONS OF EACH RADIONUCLIDE USED IN<br />

SPIKING THE WATER SAMPLES IN THIS PT<br />

Draft, page 6<br />

Nuclide Manufacturer code Source manufacturer<br />

Co-57 9031-OL-090/09 Czech Metrological Institute<br />

Co-60 Co60-ELSB50 Cerca<br />

Cs-134 Cs134ELSR50 Cerca<br />

Cs-137 CDZ64/S4/14/70 Amersham<br />

Eu-152 Eu152-ELMB90 Cerca<br />

TABLE 2. TARGET VALUES AND RESPECTIVE COMBINED STANDARD UNCERTAINTIES OF THE<br />

RADIONUCLIDES OF INTEREST IN WATER SAMPLES<br />

Analytes<br />

Water Samples<br />

02 and 04<br />

Activity<br />

(Bq/kg)<br />

Uncertainty<br />

(Bq/kg)<br />

Water Sample<br />

03<br />

Activity<br />

(Bq/kg)<br />

Uncertainty<br />

(Bq/kg)<br />

MAB<br />

(%)<br />

Co-57 7.5 0.15 2.5 0.05 10 10<br />

Co-60 6.0 0.12 2.1 0.04 10 10<br />

Cs-134 13.9 0.28 4.6 0.1 10 10<br />

Cs-137 9.5 0.19 3.2 0.06 10 10<br />

Eu-152 11.3 0.23 3.7 0.08 10 10<br />

For all measurement results the reference date is 15 November 2009, the combined standard<br />

measurement result uncertainty is expressed at 1σ level.<br />

2.3.2. Verification <strong>of</strong> the target activity values and homogeneity test<br />

The final target activity value in water samples for each radionuclide was calculated from the<br />

certified activity values assigned to each radionuclide, taking into account the successive<br />

gravimetric dilution steps, the mass <strong>of</strong> spiking mixture and the amount <strong>of</strong> water being spiked<br />

as determined from weighing. The combined standard uncertainty includes two major<br />

components: uncertainty <strong>of</strong> the certified solution and weighing uncertainty.<br />