06.01.2013 Views

Alco Controls

Alco Controls

Alco Controls

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

40<br />

<strong>Alco</strong> <strong>Controls</strong><br />

Block Diagrams<br />

EC2-35x / -37x Case Controller (EX2, Press/Temp)<br />

Inputs Outputs<br />

1 = Suction pressure 6 = EX2 Expansion valve<br />

2 = Coil out temperature 7 = Compressor (EC2-35x only)<br />

3 = Air in temperature 8 = Fan<br />

4 = Air out temperature 9 = Defrost heater<br />

5 = Defrost temperature 10= spare relay (EC2-37x only)<br />

EC2-21x / -29x Case Controller (TXV)<br />

6<br />

7<br />

9<br />

8<br />

Inputs Outputs<br />

1 = Digital Input 6 = Solenoid valve<br />

2 = Digital Input 7 = Compressor (EC2-21x only)<br />

3 = Air in temperature 8 = Fan<br />

4 = Air out temperature 9 = Defrost heater<br />

5 = Defrost temperature 10= spare relay (EC2-29x only)<br />

4<br />

3<br />

5<br />

Network<br />

2<br />

1<br />

EC2-31x / -39x Case Controller (EX2, Temp/Temp)<br />

Inputs Outputs<br />

1 = Coil in temperature 6 = EX2 Expansion valve<br />

2 = Coil out temperature 7 = Compressor (EC2-31x only)<br />

3 = Air in temperature 8 = Fan<br />

4 = Air out temperature 9 = Defrost heater<br />

5 = Defrost temperature 10= spare relay (EC2-39x only)<br />

EC2-11x Universal I/O Controller<br />

Inputs Outputs<br />

1 = Digital Input 6 = Digital output<br />

2 = Digital Input 7 = Digital output<br />

3 = Temperature input 8 = Digital output<br />

4 = Temperature input 9 = Digital output<br />

5 = Temperature input<br />

A2.5.1/1003/E