Nominal data<br />
Type Motor<br />
*3G 190 M3G 055-BD<br />
subject to alterations (1) Nominal data in operating point with maximum load and 230 V<strong>AC</strong><br />
12<br />
A<br />
<strong>EC</strong> <strong>centrifugal</strong> <strong>fans</strong> <strong>RadiCal</strong><br />
backward curved, Ø 190<br />
V<strong>AC</strong> Hz rpm W A °C<br />
1~ 200-240 50/60 2710 57 0,43 -25..+60<br />
*3G 190 M3G 055-CF B 1~ 200-240 50/60 4060 170 1,40 -25..+60 H3)<br />
*3G 190 M3G 055-BI C 1~ 200-240 50/60 3200 85 0,75 -25..+60 H4)<br />
*3G 190 M3G 055-CF D 1~ 200-240 50/60 4060 170 1,40 -25..+60 H4)<br />
Curves (2 Speed stages)<br />
p sf Pa<br />
1000 4,0<br />
800 3,2<br />
600<br />
400<br />
200<br />
in H 2O<br />
0,8 1,6<br />
2,4<br />
q V<br />
A<br />
8<br />
4<br />
B<br />
8<br />
7<br />
4<br />
3<br />
5 1<br />
0 100 200 300 400<br />
500<br />
6<br />
Curve<br />
200 400 600 800<br />
2<br />
7<br />
3<br />
Nominal<br />
voltage range<br />
6<br />
– Material: Housing: Plastic PA 6, fibreglass-reinforced<br />
Impeller: Plastic PA 6, fibreglass-reinforced<br />
Rotor: Thick layer passivated<br />
Electronics housing: Die-cast alumimium<br />
– Number of blades: 7<br />
– Direction of rotation: Clockwise, seen on rotor<br />
– Type of protection: IP 54<br />
– Insulation class: "B"<br />
– Mounting position: Any<br />
– Condensate discharges: None, open rotor<br />
– Mode of operation: Continuous operation (S1)<br />
– Bearings: Maintenance-free ball bearings<br />
2<br />
Frequency<br />
5<br />
Speed/rpm (1)<br />
1<br />
cfm<br />
m 3 /h<br />
Max.<br />
input power (1)<br />
Max.<br />
current draw (1)<br />
Air performance measured<br />
as per: ISO 5801,<br />
Installation category A,<br />
without protection against<br />
accidental contact<br />
Suction-side noise levels:<br />
LWA as per ISO 13347,<br />
LpA measured at 1 m distance<br />
to fan axis<br />
The acoustic values given are<br />
only valid under the measurment<br />
conditions listed and<br />
may vary depending on the<br />
installation situation.<br />
With any deviation to the standard<br />
setup, the specific values<br />
have to be checked and reviewed<br />
once installed or fitted!<br />
For detailed information<br />
see page 66 ff.<br />
Perm. amb. temp.<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
B<br />
B<br />
B<br />
B<br />
B<br />
B<br />
B<br />
B<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Electr. connection<br />
p. 64/65<br />
H3)<br />
n<br />
rpm<br />
2880<br />
2815<br />
2710<br />
2775<br />
2435<br />
2390<br />
2325<br />
2355<br />
4440<br />
4235<br />
4060<br />
4155<br />
3810<br />
3765<br />
3700<br />
3745<br />
P e<br />
W<br />
49<br />
52<br />
57<br />
54<br />
30<br />
32<br />
35<br />
33<br />
161<br />
165<br />
170<br />
160<br />
1<strong>04</strong><br />
117<br />
126<br />
117<br />
I<br />
A<br />
0,36<br />
0,40<br />
0,43<br />
0,41<br />
0,23<br />
0,25<br />
0,27<br />
0,26<br />
1,39<br />
1,40<br />
1,40<br />
1,37<br />
0,95<br />
1,10<br />
1,11<br />
1,07<br />
L WA<br />
dB(A)<br />
69<br />
64<br />
62<br />
66<br />
65<br />
60<br />
59<br />
63<br />
79<br />
73<br />
71<br />
73<br />
75<br />
71<br />
69<br />
71