Nominal data<br />

Type Motor<br />

*2E 190 M2E 068-BF<br />

subject to alterations<br />

p sf Pa<br />

42<br />

Curves<br />

440<br />

400<br />

360<br />

320<br />

280<br />

240<br />

200<br />

160<br />

120<br />

80<br />

40<br />

in H 2O<br />

0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8<br />

q V<br />

A<br />

B<br />

4<br />

4<br />

Curve<br />

0 50 100 150 200 250 300<br />

100 200 300 400 500<br />

A<br />

B<br />

3<br />

3<br />

Nominal voltage<br />

<strong>AC</strong> <strong>centrifugal</strong> <strong>fans</strong> <strong>RadiCal</strong><br />

backward curved, Ø 190<br />

– Material: Housing: Plastic PA 6, fibreglass-reinforced<br />

Impeller: Plastic PA 6, fibreglass-reinforced<br />

Rotor: Coated in black<br />

– Number of blades: 7<br />

– Direction of rotation: Clockwise, seen on rotor<br />

– Type of protection: IP 44, depending on installation and position in acc. to EN 60034-5<br />

– Insulation class: "B"<br />

– Mounting position: Any<br />

– Condensate discharges: Rotor-side<br />

– Mode of operation: Continuous operation (S1)<br />

– Bearings: Maintenance-free ball bearings<br />

Frequency<br />

V<strong>AC</strong> Hz rpm W A µF/VDB °C p. 64<br />

2<br />

2<br />

Speed/rpm<br />

50 Hz<br />

1<br />

Input power<br />

1<br />

cfm<br />

m 3 /h<br />

60 Hz<br />

Current draw<br />

Capacitor<br />

1~ 230 50 2480 48 0,22 1,5 / 400 -25..+65<br />

1~ 230 60 2720 60 0,27 1,5 / 400 -25..+75<br />

Air performance measured<br />

as per: ISO 5801,<br />

Installation category A,<br />

without protection against<br />

accidental contact<br />

Suction-side noise levels:<br />

LWA as per ISO 13347,<br />

LpA measured at 1 m distance<br />

to fan axis<br />

The acoustic values given are<br />

only valid under the measurment<br />

conditions listed and<br />

may vary depending on the<br />

installation situation.<br />

With any deviation to the standard<br />

setup, the specific values<br />

have to be checked and reviewed<br />

once installed or fitted!<br />

For detailed information<br />

see page 66 ff.<br />

Perm. amb. temp.<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

B<br />

B<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

Electr. connection<br />

A1)<br />

n<br />

rpm<br />

2480<br />

2440<br />

2370<br />

2435<br />

2720<br />

2645<br />

2505<br />

2615<br />

P e<br />

W<br />

48<br />

49<br />

52<br />

50<br />

60<br />

62<br />

65<br />

62<br />

I<br />

A<br />

0,22<br />

0,22<br />

0,23<br />

0,22<br />

0,27<br />

0,27<br />

0,28<br />

0,27<br />

L WA<br />

dB(A)<br />

66<br />

63<br />

60<br />

62<br />

68<br />

66<br />

62<br />

65