EC/AC centrifugal fans - RadiCal version 04/2011 - Ebm-papst Oy
EC/AC centrifugal fans - RadiCal version 04/2011 - Ebm-papst Oy
EC/AC centrifugal fans - RadiCal version 04/2011 - Ebm-papst Oy
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Nominal data<br />
Type Motor<br />
*2E 133 M2E <strong>04</strong>2-CA<br />
subject to alterations<br />
p sf Pa<br />
38<br />
Curves<br />
280<br />
240<br />
200<br />
160<br />
120<br />
80<br />
40<br />
in H 2O<br />
0,2 0,4 0,6 0,8 1,0<br />
q V<br />
A<br />
B<br />
4<br />
4<br />
Curve<br />
Nominal voltage<br />
<strong>AC</strong> <strong>centrifugal</strong> <strong>fans</strong> <strong>RadiCal</strong><br />
backward curved, Ø 133<br />
Frequency<br />
Speed/rpm<br />
0 20 40 60<br />
80<br />
100 120<br />
40 80 120 160 200<br />
A<br />
B<br />
3<br />
3<br />
Perm. amb. temp.<br />
V<strong>AC</strong> Hz rpm W A µF/VDB °C<br />
2<br />
– Material: Housing: Plastic PA 6, fibreglass-reinforced<br />
Impeller: Plastic PA 6, fibreglass-reinforced<br />
Rotor: Coated in black<br />
– Number of blades: 7<br />
– Direction of rotation: Clockwise, seen on rotor<br />
– Type of protection: IP 42, depending on installation and position in acc. to EN 60034-5<br />
– Insulation class: "B"<br />
– Mounting position: Any<br />
– Condensate discharges: Rotor-side<br />
– Mode of operation: Continuous operation (S1)<br />
– Bearings: Maintenance-free ball bearings<br />
2<br />
1<br />
50 Hz<br />
Input power<br />
1<br />
cfm<br />
m 3 /h<br />
60 Hz<br />
Current draw<br />
Capacitor<br />
1~ 230 50 2750 25 0,11 1,5 / 400 -25..+45<br />
1~ 230 60 3200 25 0,13 1,5 / 400 -25..+60<br />
Air performance measured<br />
as per: ISO 5801,<br />
Installation category A,<br />
without protection against<br />
accidental contact<br />
Suction-side noise levels:<br />
LWA as per ISO 13347,<br />
LpA measured at 1 m distance<br />
to fan axis<br />
The acoustic values given are<br />
only valid under the measurment<br />
conditions listed and<br />
may vary depending on the<br />
installation situation.<br />
With any deviation to the standard<br />
setup, the specific values<br />
have to be checked and reviewed<br />
once installed or fitted!<br />
For detailed information<br />
see page 66 ff.<br />
A<br />
A<br />
A<br />
A<br />
B<br />
B<br />
B<br />
B<br />
1<br />
2<br />
3<br />
4<br />
1<br />
2<br />
3<br />
4<br />
Electr. connection<br />
p. 64<br />
A1)<br />
n<br />
rpm<br />
2750<br />
2730<br />
2710<br />
2730<br />
3200<br />
3170<br />
3125<br />
3185<br />
P e<br />
W<br />
25<br />
25<br />
25<br />
24<br />
25<br />
26<br />
26<br />
25<br />
I<br />
A<br />
0,11<br />
0,11<br />
0,11<br />
0,11<br />
0,13<br />
0,13<br />
0,14<br />
0,13<br />
L WA<br />
dB(A)<br />
58<br />
56<br />
53<br />
57<br />
62<br />
59<br />
57<br />
60