Nominal data<br />

Type Motor<br />

*3G 220 M3G 055-BI<br />

subject to alterations (1) Nominal data in operating point with maximum load and 230 V<strong>AC</strong><br />

18<br />

A<br />

<strong>EC</strong> <strong>centrifugal</strong> <strong>fans</strong> <strong>RadiCal</strong><br />

backward curved, Ø 220<br />

V<strong>AC</strong> Hz rpm W A °C<br />

1~ 200-240 50/60 2580 85 0,70 -25..+60<br />

*3G 220 M3G 055-CF B 1~ 200-240 50/60 3210 170 1,35 -25..+45 H3)<br />

*3G 220 M3G 055-BI C 1~ 200-240 50/60 2580 85 0,70 -25..+60 H4)<br />

*3G 220 M3G 055-CF D 1~ 200-240 50/60 3210 170 1,35 -25..+45 H4)<br />

Curves (2 Speed stages)<br />

p sf Pa<br />

800 3,2<br />

600<br />

400<br />

200<br />

in H 2O<br />

0,8 1,6<br />

2,4<br />

q V<br />

B<br />

A<br />

8<br />

7<br />

4<br />

8<br />

6<br />

4<br />

Curve<br />

5 1<br />

0 100 200 300 400 500 600 700<br />

3<br />

7<br />

200 400 600 800 1000 1200 m3 /h<br />

3<br />

2<br />

Nominal<br />

voltage range<br />

6<br />

– Material: Housing: Plastic PA 6, fibreglass-reinforced<br />

Impeller: Plastic PA 6, fibreglass-reinforced<br />

Rotor: Thick layer passivated<br />

Electronics housing: Die-cast alumimium<br />

– Number of blades: 7<br />

– Direction of rotation: Clockwise, seen on rotor<br />

– Type of protection: IP 54<br />

– Insulation class: "B"<br />

– Mounting position: Any<br />

– Condensate discharges: None, open rotor<br />

– Mode of operation: Continuous operation (S1)<br />

– Bearings: Maintenance-free ball bearings<br />

Frequency<br />

2<br />

5<br />

Speed/rpm (1)<br />

1<br />

cfm<br />

Max.<br />

input power (1)<br />

Max.<br />

current draw (1)<br />

Air performance measured<br />

as per: ISO 5801,<br />

Installation category A,<br />

without protection against<br />

accidental contact<br />

Suction-side noise levels:<br />

LWA as per ISO 13347,<br />

LpA measured at 1 m distance<br />

to fan axis<br />

The acoustic values given are<br />

only valid under the measurment<br />

conditions listed and<br />

may vary depending on the<br />

installation situation.<br />

With any deviation to the standard<br />

setup, the specific values<br />

have to be checked and reviewed<br />

once installed or fitted!<br />

For detailed information<br />

see page 66 ff.<br />

Perm. amb. temp.<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

B<br />

B<br />

B<br />

B<br />

B<br />

B<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Electr. connection<br />

p. 64/65<br />

H3)<br />

n<br />

rpm<br />

2765<br />

2700<br />

2580<br />

2635<br />

1505<br />

1485<br />

1465<br />

1485<br />

3490<br />

3350<br />

3210<br />

3240<br />

2970<br />

2910<br />

2865<br />

2910<br />

P e<br />

W<br />

79<br />

84<br />

85<br />

85<br />

15<br />

16<br />

17<br />

17<br />

161<br />

166<br />

170<br />

165<br />

100<br />

110<br />

120<br />

118<br />

I<br />

A<br />

0,67<br />

0,69<br />

0,70<br />

0,70<br />

0,18<br />

0,20<br />

0,21<br />

0,19<br />

1,29<br />

1,35<br />

1,35<br />

1,35<br />

0,85<br />

0,94<br />

1,10<br />

1,01<br />

L WA<br />

dB(A)<br />

71<br />

67<br />

65<br />

67<br />

57<br />

54<br />

51<br />

52<br />

76<br />

72<br />

69<br />

71<br />

72<br />

69<br />

67<br />

69