Nominal data<br />

Type Motor<br />

*3G 133 M3G <strong>04</strong>5-AI<br />

subject to alterations (1) Nominal data in operating point with maximum load and 230 V<strong>AC</strong><br />

8<br />

Curve<br />

A<br />

Nominal<br />

voltage range<br />

<strong>EC</strong> <strong>centrifugal</strong> <strong>fans</strong> <strong>RadiCal</strong><br />

backward curved, Ø 133<br />

Frequency<br />

Speed/rpm (1)<br />

Max.<br />

input power (1)<br />

Max.<br />

current draw (1)<br />

Perm. amb. temp.<br />

V<strong>AC</strong> Hz rpm W A °C<br />

1~ 200-240 50/60 3730 27 0,26 -25..+60<br />

*3G 133 M3G <strong>04</strong>5-AI B 1~ 200-240 50/60 3730 27 0,26 -25..+60 H4)<br />

Curves (2 Speed stages)<br />

p sf Pa<br />

400<br />

360<br />

320<br />

280<br />

240<br />

200<br />

160<br />

120<br />

80<br />

40<br />

in H 2O<br />

0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6<br />

8<br />

4<br />

7<br />

5<br />

1<br />

0 20 40 60 80 100 120 140 160 cfm<br />

qV 40 80 120 160 200 240<br />

m3 /h<br />

6<br />

3<br />

– Material: Housing: Plastic PA 6, fibreglass-reinforced<br />

Impeller: Plastic PA 6, fibreglass-reinforced<br />

Rotor: Thick layer passivated<br />

Electronics housing: Die-cast alumimium<br />

– Number of blades: 7<br />

– Direction of rotation: Clockwise, seen on rotor<br />

– Type of protection: IP 54<br />

– Insulation class: "B"<br />

– Mounting position: Any<br />

– Condensate discharges: None, open rotor<br />

– Mode of operation: Continuous operation (S1)<br />

– Bearings: Maintenance-free ball bearings<br />

2<br />

A<br />

Air performance measured<br />

as per: ISO 5801,<br />

Installation category A,<br />

without protection against<br />

accidental contact<br />

Suction-side noise levels:<br />

LWA as per ISO 13347,<br />

LpA measured at 1 m distance<br />

to fan axis<br />

The acoustic values given are<br />

only valid under the measurment<br />

conditions listed and<br />

may vary depending on the<br />

installation situation.<br />

With any deviation to the standard<br />

setup, the specific values<br />

have to be checked and reviewed<br />

once installed or fitted!<br />

For detailed information<br />

see page 66 ff.<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Electr. connection<br />

p. 64/65<br />

H3)<br />

n<br />

rpm<br />

3930<br />

3800<br />

3730<br />

3835<br />

2755<br />

2690<br />

2655<br />

2705<br />

P e<br />

W<br />

24<br />

26<br />

27<br />

26<br />

10<br />

10<br />

11<br />

10<br />

I<br />

A<br />

0,23<br />

0,26<br />

0,26<br />

0,25<br />

0,11<br />

0,12<br />

0,13<br />

0,12<br />

L WA<br />

dB(A)<br />

66<br />

63<br />

61<br />

65<br />

58<br />

56<br />

53<br />

57