<strong>SIPROTEC</strong> <strong>7SJ602</strong> <strong>Multifunction</strong> <strong>Overcurrent</strong> <strong>and</strong> <strong>Motor</strong> <strong>Protection</strong> Relay<br />

Selection <strong>and</strong> Ordering Data<br />

Description Order No.<br />

<strong>SIPROTEC</strong> <strong>7SJ602</strong> <strong>7SJ602</strong>�-�����-����<br />

<strong>Multifunction</strong> overcurrent <strong>and</strong> motor protection relay<br />

ANSI No. Description<br />

Basic version<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

50N/51N Ground/earth-fault protection TOC ground/earth IE>, IE>>, IEp<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection FA 1)<br />

Basic version + directional ground/earth-fault detection<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

67Ns Directional sensitive ground/earth-fault detection IEE>, IEE>>, IEp<br />

64 Displacement voltage<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection FB 2)<br />

Basic version + sensitive ground/earth-fault detection + measuring<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

50Ns/51Ns Sensitive ground/earth-fault detection IEE>, IEE>>, IEp<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection<br />

Voltage <strong>and</strong> power measuring F J 2)<br />

Basic version + motor protection<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

50N/51N Ground/earth-fault protection TOC ground/earth IE>, IE>>, IEp<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection<br />

48 Starting time supervision<br />

37 Undercurrent/loss of load monitoring<br />

66/86 Restart inhibit HA 1)<br />

Basic version + directional ground/earth fault protection + motor protection<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

67Ns Directional sensitive ground/earth-fault detection IEE>, IEE>>, IEp<br />

64 Displacement voltage<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection<br />

48 Starting time supervision<br />

37 Undercurrent/loss of load monitoring<br />

66/86 Restart inhibit HB 2)<br />

Basic version + sensitive ground/earth-fault detection + measuring + motor protection<br />

50/51 Time-overcurrent protection TOC phase<br />

I>, I>>, Ip, reverse interlocking<br />

50Ns/51Ns Sensitive ground/earth-fault detection IEE>, IEE>>, IEp<br />

49 Overload protection<br />

74TC Trip circuit supervision<br />

50BF Breaker-failure protection<br />

Cold load pickup<br />

46 Negative sequence/unbalanced load protection<br />

Voltage <strong>and</strong> power measuring<br />

48 Starting time supervision<br />

37 Undercurrent/loss of load monitoring<br />

66/86 Restart inhibit H J 2)<br />

Auto-reclosure (ARC)<br />

Without auto-reclosure ARC 0<br />

79 With auto-reclosure ARC 1<br />

1) Only with position 7 = 1 or 5<br />

2) Only with position 7 = 2 or 6<br />

Siemens SIP 3.3 · 2003 21