a) Fire-extinguishing System for Burner Slide-in Module, Art. No. K-SLE<br />

Note: Pyromat-DYN has an extra charge with Art. No. K-SLE (see Spec Sheet 4500)<br />

With <strong>Pyrot</strong> and Pyrtec this is included in the burner article.<br />

Fig. 1: K-SLE on feed auger<br />

Spec Sheet<br />

Fire- extinguishing Systems<br />

K-SLE & K-SLV <strong>Installation</strong><br />

b) Fire-extinguishing System for Material Feed Facility, Art. No. K-SLV<br />

For Köb scope of delivery, refer to Spec Sheet 4500<br />

vIESmAnn<br />

4550-1<br />

Fig. 2: K-SLV on conveyor auger Fig. 3: K-SLV on extractor system situated on top with<br />

Down pipe<br />

Be sure to note:<br />

· The lines must be executed in metal (1/2") with fixed pipe work (K-SLE and K-SLV).<br />

· It must not be possible to shut off the cold water inlet without the aid of tools.<br />

· Be especially sure to comply with Point 5 of the <strong>Installation</strong> Instructions (Fire Prevention).<br />

Note:<br />

K-SLV is an alternative or supplementary safety device. As standard, either a slide valve (Art. No. MBA-.; included in<br />

Article ADF_.,. / ADE_3,0) is required for pressure less material storage sites or a rotary valve (Art. No. MBZ-.) for<br />

material storage sites with over- or under-pressure (loading with fan, such as wood-processing businesses).