Chromatography Data Software 2008 Product Plan - Waters
Chromatography Data Software 2008 Product Plan - Waters
Chromatography Data Software 2008 Product Plan - Waters
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
©2011 <strong>Waters</strong> Corporation<br />
Empower 3<br />
Control of Instruments<br />
3rd Party Control<br />
Mogens Hallas<br />
Nordic User Training 2011<br />
Långvik, September 6 th to 9th<br />
1
©2011 <strong>Waters</strong> Corporation<br />
2
Empower 3<br />
Obsoleted support of detectors<br />
The following instrumentation is reaching its end<br />
of life, is on limited support status and will no<br />
longer be supported in Empower 3:<br />
- 410 RI Detector<br />
- 486 TUV Detector<br />
- 996 PDA Detector<br />
- 474 Fluorescence Detector<br />
Support for the A5890S and 7673S under serial<br />
control (Using LAN Serial Control)<br />
But not serial busLAC/E control, will remain in<br />
Empower 3.<br />
©2011 <strong>Waters</strong> Corporation<br />
3
Equinox Serial 8-Port Card<br />
Equinox Serial Card is only supported on Windows XP<br />
32-bit – Not in Windows 7.<br />
Current serial instrument support using the Equinox<br />
8-port card is:<br />
- Agilent 5890 GC (5890S)<br />
- Agilent 7673 GC autosampler (7673S)<br />
- Agilent 6890 GC (all models, including 6890N)<br />
- Agilent 6850 GC (serial number
Prior to Empower 3<br />
Previously discontinued instrumenys<br />
As a reminder, support for the following instruments<br />
has been previously been discontinued:<br />
Not supported as of Empower 2<br />
- Integrity TMD<br />
- ISA BusLAC/E card<br />
- GPC 2000<br />
- 5890 GC (under busLAC/E control)<br />
- 7673 (under busLAC/E control)<br />
Not supported as of Empower build 1154<br />
- 700, 710, and 712 Injectors<br />
- 715 Autosampler<br />
- LC Module 1<br />
Not supported as of Millennium32 v4.0<br />
- <strong>Waters</strong> 490 Variable UV<br />
©2011 <strong>Waters</strong> Corporation<br />
5
Instrument Control<br />
� Provide a comprehensive, reliable and robust feature set for<br />
each instrument we support.<br />
— <strong>Waters</strong> works closely with its customers to ensure the<br />
instruments supported with Empower <strong>Software</strong> provided scientist<br />
the capabilities to realize the most value from their instrument<br />
investment.<br />
� Instrument Driver Approach - Open Instrument Portal (OIP)<br />
— Similar to the Microsoft Printer driver approach<br />
— Allows creation of software plug-ins to add hardware control<br />
capabilities<br />
— <strong>Waters</strong> uses and other instrument vendors<br />
to create instrument control<br />
©2011 <strong>Waters</strong> Corporation<br />
6
What is OIP Technology?<br />
� Open Interface Portal (OIP) technology is a<br />
software architecture that allows for a<br />
standardized specification of the interaction<br />
between the <strong>Data</strong> System and an instrument.<br />
� This allows for the development of an instrument<br />
―driver‖ that can be added to Empower <strong>Software</strong><br />
without changing the core application.<br />
� OIP technology is separate from the physical<br />
connectivity (serial, ethernet, USB, IEEE-488)<br />
� OIP technology takes advantage of other software<br />
specifications: COM, ActiveX, XML<br />
©2011 <strong>Waters</strong> Corporation<br />
7
Extended Instrument Control Using<br />
OIP with Empower <strong>Software</strong><br />
� One software solution for all chromatographic systems<br />
©2011 <strong>Waters</strong> Corporation<br />
— Reduced training, validation and support<br />
� 16 vendors with over 235+ instruments<br />
— Instrument control available from major LC Vendors including<br />
<strong>Waters</strong>, Agilent, Shimadzu, Hitachi and Dionex *)<br />
— Instrument Control Available from major GC Vendors including<br />
Agilent, Shimadzu, PerkinElmer and Varian<br />
� New instrument control<br />
— <strong>Waters</strong> ACQUITY H-Class<br />
— <strong>Waters</strong> Thar SFC<br />
— Beckman CE<br />
— WFC III<br />
*) some are still in testing<br />
8
Instrument control via OIP<br />
� Created by <strong>Waters</strong><br />
©2011 <strong>Waters</strong> Corporation<br />
— HPLC systems and module, ACQUITY UPLC, Single-quad & Triple-quad<br />
MS, A/D Converter, Agilent 6850 GC, Agilent 7694 Headspace Sampler,<br />
Agilent 1100, 1200 and 1260/1290 series LC modules<br />
� Created by Other Instrument Vendors<br />
— CTC PAL Autosamplers<br />
— Varian 3900 GC<br />
— Perkin-Elmer GC<br />
— Tekmar HT3 Headspace Sampler<br />
— Dissolution Baths<br />
o Hanson SR8-Plus, Distek (2100C,<br />
Evolution 6100 & 6300), Sotax and<br />
Erweka DT800 Online System<br />
— Selerity Polaratherm 9000<br />
— Shimadzu Prominence LC 20 System<br />
— Hitachi LaChrom Elite Systems<br />
— Dionex<br />
9
Complete list of all controlled systems<br />
©2011 <strong>Waters</strong> Corporation<br />
10
Third Party Instrument Control in Empower 3<br />
<strong>Waters</strong> policy is to notify their software partners when a new informatics<br />
software product is under development. The Empower 3 team has notified all of<br />
our partners about Empower 3 and has offered beta software for use in testing<br />
/development of ICS software, for Empower 3.<br />
To date not all vendors have requested Empower 3 beta or released software.<br />
We have recently reminded our partners that the release of Empower 3 software<br />
and we would like to offer our mutual support of their products. We will contact<br />
our partners again.<br />
©2011 <strong>Waters</strong> Corporation<br />
Please refer users who are requesting third party instrument control to the<br />
appropriate vendors to request support of these instruments in Empower 3.<br />
11
Instrument control<br />
� Consistent instrument interface assist in training new software<br />
users as new techniques such as Gas <strong>Chromatography</strong> (GC) or<br />
Ultra Performance Liquid <strong>Chromatography</strong> (UPLC) are introduce<br />
to the laboratory.<br />
©2011 <strong>Waters</strong> Corporation<br />
12
Instrument Control<br />
� Once instrument parameters are entered into the Empower<br />
software they can be completely managed by the software to<br />
ensure that these same parameters are used for all future<br />
analysis.<br />
— If changes are required, all instrument parameters are<br />
completely documented in Empower's embedded relational<br />
database with complete audit trail including what changes were<br />
made, who made the changes, when the changes were made<br />
and why.<br />
©2011 <strong>Waters</strong> Corporation<br />
13
<strong>Waters</strong> HPLC’s<br />
� Full control of <strong>Waters</strong><br />
binary and quaternary<br />
pumps.<br />
� Full control of Multiple<br />
wavelength, Photodiode<br />
array, Fluorescence, and<br />
RI detectors.<br />
� Full Control of sample<br />
compartment and column<br />
oven temperatures<br />
� Full control of<br />
autosamplers.<br />
� Full control of <strong>Waters</strong><br />
single quad mass<br />
detectors.<br />
©2011 <strong>Waters</strong> Corporation<br />
14
<strong>Waters</strong> UPLC<br />
� Full control of <strong>Waters</strong><br />
binary and quaternary<br />
pumps.<br />
� Full control of Multiple<br />
wavelength, Photodiode<br />
array, Fluorescence, and<br />
RI detectors.<br />
� Full Control of sample<br />
compartment and<br />
column oven<br />
temperatures<br />
� Full control of<br />
autosamplers.<br />
� Full control of <strong>Waters</strong><br />
Mass Spec detectors.<br />
©2011 <strong>Waters</strong> Corporation<br />
15
<strong>Waters</strong> Mass Detectors<br />
� <strong>Data</strong> acquisition and<br />
instrument control of Mass<br />
Detectors.<br />
� Greater specificity of<br />
analysis.<br />
� Easily use MS and MS/MS<br />
in QC and Development<br />
lab environments.<br />
� 1st <strong>Chromatography</strong><br />
<strong>Software</strong> to offer Tandem<br />
control and data<br />
processing in a network or<br />
regulated environment<br />
©2011 <strong>Waters</strong> Corporation<br />
16
Mass Detection <strong>Waters</strong> SQD & TQD<br />
� <strong>Data</strong> acquisition and instrument control of Mass Detectors<br />
� Greater specificity of analysis<br />
� Easily use MS and MS/MS in QC and Development lab environments<br />
1 st <strong>Chromatography</strong> <strong>Software</strong><br />
to offer Tandem control and<br />
data processing in a network<br />
or regulated environment.<br />
©2011 <strong>Waters</strong> Corporation<br />
17
Supercritical Fluid <strong>Chromatography</strong><br />
(SFC)<br />
� Thar Method Station & SFC-MS Resolution Systems<br />
— Analytical to semi-preparative purification solutions<br />
� Control includes:<br />
— Fluid Delivery Module and co-solvent selection<br />
— Photodiode Array, UV & ELSD detectors<br />
— Column oven and column selection<br />
— Automated Back Pressure Regulator<br />
— Thar Autosampler<br />
— <strong>Waters</strong> 3100 MS detectors<br />
— <strong>Waters</strong> Fraction Collector III<br />
©2011 <strong>Waters</strong> Corporation<br />
18
ACQUITY UPSFC System<br />
©2011 <strong>Waters</strong> Corporation<br />
19
Dissolution Baths<br />
� Integrity of your HPLC<br />
dissolution testing<br />
methods and results,<br />
helping increase lab<br />
productivity.<br />
� Combined software and<br />
hardware solution.<br />
— Hanson SR8-Plus<br />
— Distek 2100C, Evolution 6100<br />
& 6300<br />
— Sotax<br />
— Erweka DT800 Online<br />
Dissolution System<br />
— Vankel VK 7000<br />
— Vankel VK 7010<br />
©2011 <strong>Waters</strong> Corporation<br />
20
Agilent 1100/1200/1260/1290 LC<br />
� Full control of Isocratic,<br />
Binary and Quatenary<br />
pumps.<br />
� Full control of<br />
Autosampler.<br />
� Full control of UV,<br />
MWV, RI, FLD and DAD<br />
detectors<br />
� Full control of column<br />
oven.<br />
©2011 <strong>Waters</strong> Corporation<br />
21
Agilent 5890 Series II GC<br />
� Control with either 7673 or<br />
G1512 Controller<br />
� Dual Tower capability (With<br />
serial card only)<br />
� Detector Supported<br />
FID,NPD,TCD,ECD<br />
� Sampling Rates of 1.25, 2.5,<br />
5, 10, 20 points per second.<br />
� Fully Programmable<br />
temperatures:<br />
©2011 <strong>Waters</strong> Corporation<br />
— limits, ramps, and hold<br />
times.<br />
� Injector inlet zone<br />
temperature setting.<br />
22
Agilent 6890 / 6890N GC<br />
� 6890 supported in both Single<br />
and Dual Tower mode.<br />
� Sampling Rates of 0.1, 0.2,<br />
0.5, 1, 2, 5, 10, 20, 50, 100,<br />
and 200 points per second.<br />
� Fully Programmable<br />
temperatures:<br />
— limits, ramps, and hold times<br />
� Detector options:<br />
— Unknown (Other detectors)<br />
— FID (Flame Ionization)<br />
— TCD (Thermal Conductivity)<br />
— NPD (Nitrogen Phosphorous)<br />
— ECD (Electron Capture)<br />
— uECD (Micro Electron Capture)<br />
— FPD ( Flame Photometric)<br />
©2011 <strong>Waters</strong> Corporation<br />
23
Agilent 6850 GC<br />
� Inlet: Split/Splitless &<br />
Purged Pack<br />
©2011 <strong>Waters</strong> Corporation<br />
— limits, ramps, and hold<br />
times<br />
� Cool On-Column inlet<br />
project in progress<br />
� Detector options:<br />
— FID (Flame Ionization)<br />
— TCD (Thermal<br />
Conductivity)<br />
24
Agilent HS7694 Headspace Sampler<br />
� Introduced July, 2003<br />
� The first<br />
Headspace/GC system<br />
control option in a<br />
compliance-friendly<br />
CDS<br />
� G1289B and G1290B<br />
©2011 <strong>Waters</strong> Corporation<br />
25
Agilent G1888 Headspace Sampler<br />
� Headspace Control Option<br />
©2011 <strong>Waters</strong> Corporation<br />
— Will continue support for the 7694<br />
— Will add support for the G1888<br />
— Will allow remote operation through a<br />
LAC/E module<br />
26
Tekmar HT3 GC Headspace<br />
� Tekmar HT3 Static and Dynamic Headspace System driver available<br />
from Teledyne Tekmar<br />
� Static Headspace analysis: robust technique for volatile compounds<br />
analysis of in almost any matrix.<br />
� Dramatic improvements in sensitivity by new Dynamic Headspace<br />
option, while maintaining ruggedness and reliability of traditional<br />
Static Headspace.<br />
©2011 <strong>Waters</strong> Corporation<br />
27
Varian 39XL GC<br />
� Drivers available from Varian <strong>Product</strong> Sales<br />
� Single 1177 split/splitless or 1041 injector equipped with Injector<br />
Electronic Flow Control, FID or TCD detector with Electronic Flow<br />
Control<br />
� Option: keypad and<br />
Ethernet communications<br />
©2011 <strong>Waters</strong> Corporation<br />
28
CTC PAL Injection Systems<br />
� LC PAL, GC PAL and Combi PAL drivers available from CTC Analytics<br />
� Automated GC and LC injection systems<br />
� Outstanding performance and maximum flexibility in every LC sample<br />
processing system<br />
� Provides powerful working capabilities and maximum flexibility in<br />
every GC sample processing system<br />
� Combi PAL, the only GC sample injection system combining liquid,<br />
large volume, headspace, in tube extraction in a single instrument.<br />
©2011 <strong>Waters</strong> Corporation<br />
29
Beckman CE Systems<br />
� Beckman P/ACE MDQ & PA 800 Capillary Electrophoresis Systems<br />
� Control includes photo diode array and selectable wavelength UV/Vis<br />
(with 200, 214, 254 and 280 nm filters) detector, UV source optics,<br />
temperature-controlled sample storage module and LIF Detector<br />
� Beckman CE Control License includes instrument control software,<br />
license, documentation, and an IEEE-to-Ethernet converter to connect<br />
Beckman CE (IEEE-488) via Ethernet<br />
� Support for the LIF (Laser-Induced Fluorescence) detector<br />
©2011 <strong>Waters</strong> Corporation<br />
30
Selerity Polaratherm 9000 Total<br />
Temperature Controller<br />
� Selerity Polaratherm<br />
9000 Total Temperature<br />
Controller<br />
©2011 <strong>Waters</strong> Corporation<br />
o Temperature<br />
programmed HPLC is<br />
taken to extremes with<br />
the Polaratherm Series<br />
9000 Total Temperature<br />
Controller with mobile<br />
phase preheating, and<br />
optional cryo cooling.<br />
31
Shimadzu Prominence LC 20 System<br />
� Prominence LC 20 drivers available from Shimadzu<br />
� Availability expected 3Q, 2007<br />
� Supported Modules<br />
©2011 <strong>Waters</strong> Corporation<br />
— System Controller - CBM-20A, CBM-20A lite<br />
— Pump - LC-20AD, LC-20AT, LC-20AB<br />
— Autosampler - SIL-20A, SIL-20AC, Rack Changer, Rack Changer/C<br />
— Column Oven - CTO-20A, CTO-20AC<br />
— Detector - SPD-20A, SPD-20AV, SPD-M20A (PDA)<br />
— Solenoid valve - LPGE unit built in LC-20AD/20AT<br />
— Rotary valve - FCV-12AH installed in CTO-20A/20AC<br />
— Rotary valve - FCV-14AH installed in CTO-20A/20AC<br />
— Analog input - PC-55N<br />
32
Shimadzu GC<br />
� GC System Shimadzu GC-2010<br />
� GC System Shimadzu GC-2010 Plus<br />
� GC System Shimadzu GC-2014<br />
� GC Autosampler Shimadzu AOC-20i<br />
� GC Autosampler Shimadzu AOC-20i/s<br />
©2011 <strong>Waters</strong> Corporation<br />
33
PerkinElmer Clarus GC<br />
� PerkinElmer Clarus 400 GC<br />
� PerkinElmer Clarus 500 GC<br />
� PerkinElmer Clarus 600 GC<br />
©2011 <strong>Waters</strong> Corporation<br />
34
Perkin Elmer GC and HS<br />
•TurboMatrix Headspace samplers<br />
©2011 <strong>Waters</strong> Corporation<br />
35
Hitachi LaChrom Elite Systems<br />
� LaChrom Elite System drivers available from Hitachi<br />
� Availability expected 4Q, 2007<br />
� Supported Modules<br />
©2011 <strong>Waters</strong> Corporation<br />
— L-2100 and L-2130 - Pump<br />
— L-2200 - Autosampler<br />
— L-2300 and L-2350 - Column Oven<br />
— L-2400 - UV Detector<br />
— L-2420 - UV / Vis Detector<br />
— L-2450 and L-2455 - Diode Array Detector<br />
— L-2480 and L-2485 - Fluorescence Detector<br />
— L-2490 - Refractive Index Detector<br />
— AID - Analog Input Device (Single Channel)<br />
36
Hitachi LaChromUltra<br />
� Hitachi LaChromUltra L-2160U Pump<br />
� Hitachi LaChromUltra L-2200U Autosampler<br />
� Hitachi LaChromUltra L-2400U UV Detector<br />
� Hitachi LaChromUltra L-2420U UV-Vis Detector<br />
� Hitachi LaChrom L-2455U Diode Array Detector<br />
� Hitachi LaChromUltra L-2485U Fluorescence Detector<br />
©2011 <strong>Waters</strong> Corporation<br />
37
ESA Biosciences<br />
� ESA pump,<br />
� ESA Coulochem III electrochemical detector,<br />
� ESA Corona, Corona Plus, Corona Ultra CAD detectors,<br />
� CAD v1.23 Detector<br />
� Corona Plus V1.23<br />
� Corona Ultra V1.05<br />
©2011 <strong>Waters</strong> Corporation<br />
38
Dionex UltiMate 3000/<br />
� UltiMate 3000/3000 RSLC LPG-3400SD Quaternary Analytical pump<br />
� UltiMate 3000/3000 RSLC LPG-3400BM Quaternary Biocompatible Micro pump<br />
� UltiMate 3000/3000 RSLC DGP-3600 pumps<br />
� UltiMate 3000/3000 RSLC DGP-3600RS rapid separation dual low-pressure gradient pump<br />
� UltiMate 3000/3000 RSLC DGP-3600SD analytical dual low-pressure gradient pump<br />
� UltiMate 3000/3000 RSLC DGP-3600BM biocompatible dual low-pressure gradient pump<br />
� UltiMate 3000/3000 RSLC HPG-3x00 pumps<br />
� UltiMate 3000/3000 RSLC HPG-3x00RS rapid separation high-pressure gradient pump<br />
� UltiMate 3000/3000 RSLC HPG-3x00SD analytical high-pressure gradient pump<br />
� UltiMate 3000/3000 RSLC ISO-3100 pumps<br />
� UltiMate 3000/3000 RSLC ISO-3100SD analytical isocratic pump<br />
� UltiMate 3000/3000 RSLC ISO-3100BM biocompatible isocratic micro pump<br />
� UltiMate 3000/3000 RSLC FLM-3x00 flow managers and termostatted column compartments<br />
� UltiMate 3000/3000 RSLC TCC-3X00(RS) thermostatted column compartments<br />
� UltiMate 3000/3000 RSLC ACC-3000 autosampler column compartment<br />
� UltiMate 3000/3000 RSLC WPS-3000(RS) autosamplers<br />
� UltiMate 3000/3000 RSLC DAD-3000(RS) diode-array detector<br />
� UltiMate 3000/3000 RSLC FLD-3x00(RS) fluorescence detector<br />
� UltiMate 3000/3000 RSLC MWD-3000(RS) multi-wavelength detector<br />
� UltiMate 3000/3000 RSLC VWD-3x00(RS) variable-wavelength detectors<br />
©2011 <strong>Waters</strong> Corporation<br />
39
Dionex IC systems<br />
� Control of Dionex range of IC systems under development<br />
©2011 <strong>Waters</strong> Corporation<br />
— ICS-5000 Reagent-Free IC System<br />
— ICS-2100 Integrated Reagent-Free IC System<br />
— ICS-1600 Standard Integrated IC System<br />
— ICS-1100 Basic Integrated IC System<br />
— ICS-900 Starter Line IC System<br />
40
Extended Instrument Control with<br />
Empower <strong>Software</strong><br />
� Benefit to the Users: One <strong>Software</strong> solution for all<br />
chromatographic systems<br />
©2011 <strong>Waters</strong> Corporation<br />
— Reduced Training, Validation and Support<br />
� Instrument Control Available Today<br />
— 16 Vendors with 235+ Instrument modules<br />
— Major LC and GC Vendors<br />
� New Techniques<br />
— Supercritical Fluid <strong>Chromatography</strong> (SFC)<br />
— Capillary Electrophoresis (CE)<br />
41
©2011 <strong>Waters</strong> Corporation<br />
42