13.01.2013 Views

Chromatography Data Software 2008 Product Plan - Waters

Chromatography Data Software 2008 Product Plan - Waters

Chromatography Data Software 2008 Product Plan - Waters

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

©2011 <strong>Waters</strong> Corporation<br />

Empower 3<br />

Control of Instruments<br />

3rd Party Control<br />

Mogens Hallas<br />

Nordic User Training 2011<br />

Långvik, September 6 th to 9th<br />

1


©2011 <strong>Waters</strong> Corporation<br />

2


Empower 3<br />

Obsoleted support of detectors<br />

The following instrumentation is reaching its end<br />

of life, is on limited support status and will no<br />

longer be supported in Empower 3:<br />

- 410 RI Detector<br />

- 486 TUV Detector<br />

- 996 PDA Detector<br />

- 474 Fluorescence Detector<br />

Support for the A5890S and 7673S under serial<br />

control (Using LAN Serial Control)<br />

But not serial busLAC/E control, will remain in<br />

Empower 3.<br />

©2011 <strong>Waters</strong> Corporation<br />

3


Equinox Serial 8-Port Card<br />

Equinox Serial Card is only supported on Windows XP<br />

32-bit – Not in Windows 7.<br />

Current serial instrument support using the Equinox<br />

8-port card is:<br />

- Agilent 5890 GC (5890S)<br />

- Agilent 7673 GC autosampler (7673S)<br />

- Agilent 6890 GC (all models, including 6890N)<br />

- Agilent 6850 GC (serial number


Prior to Empower 3<br />

Previously discontinued instrumenys<br />

As a reminder, support for the following instruments<br />

has been previously been discontinued:<br />

Not supported as of Empower 2<br />

- Integrity TMD<br />

- ISA BusLAC/E card<br />

- GPC 2000<br />

- 5890 GC (under busLAC/E control)<br />

- 7673 (under busLAC/E control)<br />

Not supported as of Empower build 1154<br />

- 700, 710, and 712 Injectors<br />

- 715 Autosampler<br />

- LC Module 1<br />

Not supported as of Millennium32 v4.0<br />

- <strong>Waters</strong> 490 Variable UV<br />

©2011 <strong>Waters</strong> Corporation<br />

5


Instrument Control<br />

� Provide a comprehensive, reliable and robust feature set for<br />

each instrument we support.<br />

— <strong>Waters</strong> works closely with its customers to ensure the<br />

instruments supported with Empower <strong>Software</strong> provided scientist<br />

the capabilities to realize the most value from their instrument<br />

investment.<br />

� Instrument Driver Approach - Open Instrument Portal (OIP)<br />

— Similar to the Microsoft Printer driver approach<br />

— Allows creation of software plug-ins to add hardware control<br />

capabilities<br />

— <strong>Waters</strong> uses and other instrument vendors<br />

to create instrument control<br />

©2011 <strong>Waters</strong> Corporation<br />

6


What is OIP Technology?<br />

� Open Interface Portal (OIP) technology is a<br />

software architecture that allows for a<br />

standardized specification of the interaction<br />

between the <strong>Data</strong> System and an instrument.<br />

� This allows for the development of an instrument<br />

―driver‖ that can be added to Empower <strong>Software</strong><br />

without changing the core application.<br />

� OIP technology is separate from the physical<br />

connectivity (serial, ethernet, USB, IEEE-488)<br />

� OIP technology takes advantage of other software<br />

specifications: COM, ActiveX, XML<br />

©2011 <strong>Waters</strong> Corporation<br />

7


Extended Instrument Control Using<br />

OIP with Empower <strong>Software</strong><br />

� One software solution for all chromatographic systems<br />

©2011 <strong>Waters</strong> Corporation<br />

— Reduced training, validation and support<br />

� 16 vendors with over 235+ instruments<br />

— Instrument control available from major LC Vendors including<br />

<strong>Waters</strong>, Agilent, Shimadzu, Hitachi and Dionex *)<br />

— Instrument Control Available from major GC Vendors including<br />

Agilent, Shimadzu, PerkinElmer and Varian<br />

� New instrument control<br />

— <strong>Waters</strong> ACQUITY H-Class<br />

— <strong>Waters</strong> Thar SFC<br />

— Beckman CE<br />

— WFC III<br />

*) some are still in testing<br />

8


Instrument control via OIP<br />

� Created by <strong>Waters</strong><br />

©2011 <strong>Waters</strong> Corporation<br />

— HPLC systems and module, ACQUITY UPLC, Single-quad & Triple-quad<br />

MS, A/D Converter, Agilent 6850 GC, Agilent 7694 Headspace Sampler,<br />

Agilent 1100, 1200 and 1260/1290 series LC modules<br />

� Created by Other Instrument Vendors<br />

— CTC PAL Autosamplers<br />

— Varian 3900 GC<br />

— Perkin-Elmer GC<br />

— Tekmar HT3 Headspace Sampler<br />

— Dissolution Baths<br />

o Hanson SR8-Plus, Distek (2100C,<br />

Evolution 6100 & 6300), Sotax and<br />

Erweka DT800 Online System<br />

— Selerity Polaratherm 9000<br />

— Shimadzu Prominence LC 20 System<br />

— Hitachi LaChrom Elite Systems<br />

— Dionex<br />

9


Complete list of all controlled systems<br />

©2011 <strong>Waters</strong> Corporation<br />

10


Third Party Instrument Control in Empower 3<br />

<strong>Waters</strong> policy is to notify their software partners when a new informatics<br />

software product is under development. The Empower 3 team has notified all of<br />

our partners about Empower 3 and has offered beta software for use in testing<br />

/development of ICS software, for Empower 3.<br />

To date not all vendors have requested Empower 3 beta or released software.<br />

We have recently reminded our partners that the release of Empower 3 software<br />

and we would like to offer our mutual support of their products. We will contact<br />

our partners again.<br />

©2011 <strong>Waters</strong> Corporation<br />

Please refer users who are requesting third party instrument control to the<br />

appropriate vendors to request support of these instruments in Empower 3.<br />

11


Instrument control<br />

� Consistent instrument interface assist in training new software<br />

users as new techniques such as Gas <strong>Chromatography</strong> (GC) or<br />

Ultra Performance Liquid <strong>Chromatography</strong> (UPLC) are introduce<br />

to the laboratory.<br />

©2011 <strong>Waters</strong> Corporation<br />

12


Instrument Control<br />

� Once instrument parameters are entered into the Empower<br />

software they can be completely managed by the software to<br />

ensure that these same parameters are used for all future<br />

analysis.<br />

— If changes are required, all instrument parameters are<br />

completely documented in Empower's embedded relational<br />

database with complete audit trail including what changes were<br />

made, who made the changes, when the changes were made<br />

and why.<br />

©2011 <strong>Waters</strong> Corporation<br />

13


<strong>Waters</strong> HPLC’s<br />

� Full control of <strong>Waters</strong><br />

binary and quaternary<br />

pumps.<br />

� Full control of Multiple<br />

wavelength, Photodiode<br />

array, Fluorescence, and<br />

RI detectors.<br />

� Full Control of sample<br />

compartment and column<br />

oven temperatures<br />

� Full control of<br />

autosamplers.<br />

� Full control of <strong>Waters</strong><br />

single quad mass<br />

detectors.<br />

©2011 <strong>Waters</strong> Corporation<br />

14


<strong>Waters</strong> UPLC<br />

� Full control of <strong>Waters</strong><br />

binary and quaternary<br />

pumps.<br />

� Full control of Multiple<br />

wavelength, Photodiode<br />

array, Fluorescence, and<br />

RI detectors.<br />

� Full Control of sample<br />

compartment and<br />

column oven<br />

temperatures<br />

� Full control of<br />

autosamplers.<br />

� Full control of <strong>Waters</strong><br />

Mass Spec detectors.<br />

©2011 <strong>Waters</strong> Corporation<br />

15


<strong>Waters</strong> Mass Detectors<br />

� <strong>Data</strong> acquisition and<br />

instrument control of Mass<br />

Detectors.<br />

� Greater specificity of<br />

analysis.<br />

� Easily use MS and MS/MS<br />

in QC and Development<br />

lab environments.<br />

� 1st <strong>Chromatography</strong><br />

<strong>Software</strong> to offer Tandem<br />

control and data<br />

processing in a network or<br />

regulated environment<br />

©2011 <strong>Waters</strong> Corporation<br />

16


Mass Detection <strong>Waters</strong> SQD & TQD<br />

� <strong>Data</strong> acquisition and instrument control of Mass Detectors<br />

� Greater specificity of analysis<br />

� Easily use MS and MS/MS in QC and Development lab environments<br />

1 st <strong>Chromatography</strong> <strong>Software</strong><br />

to offer Tandem control and<br />

data processing in a network<br />

or regulated environment.<br />

©2011 <strong>Waters</strong> Corporation<br />

17


Supercritical Fluid <strong>Chromatography</strong><br />

(SFC)<br />

� Thar Method Station & SFC-MS Resolution Systems<br />

— Analytical to semi-preparative purification solutions<br />

� Control includes:<br />

— Fluid Delivery Module and co-solvent selection<br />

— Photodiode Array, UV & ELSD detectors<br />

— Column oven and column selection<br />

— Automated Back Pressure Regulator<br />

— Thar Autosampler<br />

— <strong>Waters</strong> 3100 MS detectors<br />

— <strong>Waters</strong> Fraction Collector III<br />

©2011 <strong>Waters</strong> Corporation<br />

18


ACQUITY UPSFC System<br />

©2011 <strong>Waters</strong> Corporation<br />

19


Dissolution Baths<br />

� Integrity of your HPLC<br />

dissolution testing<br />

methods and results,<br />

helping increase lab<br />

productivity.<br />

� Combined software and<br />

hardware solution.<br />

— Hanson SR8-Plus<br />

— Distek 2100C, Evolution 6100<br />

& 6300<br />

— Sotax<br />

— Erweka DT800 Online<br />

Dissolution System<br />

— Vankel VK 7000<br />

— Vankel VK 7010<br />

©2011 <strong>Waters</strong> Corporation<br />

20


Agilent 1100/1200/1260/1290 LC<br />

� Full control of Isocratic,<br />

Binary and Quatenary<br />

pumps.<br />

� Full control of<br />

Autosampler.<br />

� Full control of UV,<br />

MWV, RI, FLD and DAD<br />

detectors<br />

� Full control of column<br />

oven.<br />

©2011 <strong>Waters</strong> Corporation<br />

21


Agilent 5890 Series II GC<br />

� Control with either 7673 or<br />

G1512 Controller<br />

� Dual Tower capability (With<br />

serial card only)<br />

� Detector Supported<br />

FID,NPD,TCD,ECD<br />

� Sampling Rates of 1.25, 2.5,<br />

5, 10, 20 points per second.<br />

� Fully Programmable<br />

temperatures:<br />

©2011 <strong>Waters</strong> Corporation<br />

— limits, ramps, and hold<br />

times.<br />

� Injector inlet zone<br />

temperature setting.<br />

22


Agilent 6890 / 6890N GC<br />

� 6890 supported in both Single<br />

and Dual Tower mode.<br />

� Sampling Rates of 0.1, 0.2,<br />

0.5, 1, 2, 5, 10, 20, 50, 100,<br />

and 200 points per second.<br />

� Fully Programmable<br />

temperatures:<br />

— limits, ramps, and hold times<br />

� Detector options:<br />

— Unknown (Other detectors)<br />

— FID (Flame Ionization)<br />

— TCD (Thermal Conductivity)<br />

— NPD (Nitrogen Phosphorous)<br />

— ECD (Electron Capture)<br />

— uECD (Micro Electron Capture)<br />

— FPD ( Flame Photometric)<br />

©2011 <strong>Waters</strong> Corporation<br />

23


Agilent 6850 GC<br />

� Inlet: Split/Splitless &<br />

Purged Pack<br />

©2011 <strong>Waters</strong> Corporation<br />

— limits, ramps, and hold<br />

times<br />

� Cool On-Column inlet<br />

project in progress<br />

� Detector options:<br />

— FID (Flame Ionization)<br />

— TCD (Thermal<br />

Conductivity)<br />

24


Agilent HS7694 Headspace Sampler<br />

� Introduced July, 2003<br />

� The first<br />

Headspace/GC system<br />

control option in a<br />

compliance-friendly<br />

CDS<br />

� G1289B and G1290B<br />

©2011 <strong>Waters</strong> Corporation<br />

25


Agilent G1888 Headspace Sampler<br />

� Headspace Control Option<br />

©2011 <strong>Waters</strong> Corporation<br />

— Will continue support for the 7694<br />

— Will add support for the G1888<br />

— Will allow remote operation through a<br />

LAC/E module<br />

26


Tekmar HT3 GC Headspace<br />

� Tekmar HT3 Static and Dynamic Headspace System driver available<br />

from Teledyne Tekmar<br />

� Static Headspace analysis: robust technique for volatile compounds<br />

analysis of in almost any matrix.<br />

� Dramatic improvements in sensitivity by new Dynamic Headspace<br />

option, while maintaining ruggedness and reliability of traditional<br />

Static Headspace.<br />

©2011 <strong>Waters</strong> Corporation<br />

27


Varian 39XL GC<br />

� Drivers available from Varian <strong>Product</strong> Sales<br />

� Single 1177 split/splitless or 1041 injector equipped with Injector<br />

Electronic Flow Control, FID or TCD detector with Electronic Flow<br />

Control<br />

� Option: keypad and<br />

Ethernet communications<br />

©2011 <strong>Waters</strong> Corporation<br />

28


CTC PAL Injection Systems<br />

� LC PAL, GC PAL and Combi PAL drivers available from CTC Analytics<br />

� Automated GC and LC injection systems<br />

� Outstanding performance and maximum flexibility in every LC sample<br />

processing system<br />

� Provides powerful working capabilities and maximum flexibility in<br />

every GC sample processing system<br />

� Combi PAL, the only GC sample injection system combining liquid,<br />

large volume, headspace, in tube extraction in a single instrument.<br />

©2011 <strong>Waters</strong> Corporation<br />

29


Beckman CE Systems<br />

� Beckman P/ACE MDQ & PA 800 Capillary Electrophoresis Systems<br />

� Control includes photo diode array and selectable wavelength UV/Vis<br />

(with 200, 214, 254 and 280 nm filters) detector, UV source optics,<br />

temperature-controlled sample storage module and LIF Detector<br />

� Beckman CE Control License includes instrument control software,<br />

license, documentation, and an IEEE-to-Ethernet converter to connect<br />

Beckman CE (IEEE-488) via Ethernet<br />

� Support for the LIF (Laser-Induced Fluorescence) detector<br />

©2011 <strong>Waters</strong> Corporation<br />

30


Selerity Polaratherm 9000 Total<br />

Temperature Controller<br />

� Selerity Polaratherm<br />

9000 Total Temperature<br />

Controller<br />

©2011 <strong>Waters</strong> Corporation<br />

o Temperature<br />

programmed HPLC is<br />

taken to extremes with<br />

the Polaratherm Series<br />

9000 Total Temperature<br />

Controller with mobile<br />

phase preheating, and<br />

optional cryo cooling.<br />

31


Shimadzu Prominence LC 20 System<br />

� Prominence LC 20 drivers available from Shimadzu<br />

� Availability expected 3Q, 2007<br />

� Supported Modules<br />

©2011 <strong>Waters</strong> Corporation<br />

— System Controller - CBM-20A, CBM-20A lite<br />

— Pump - LC-20AD, LC-20AT, LC-20AB<br />

— Autosampler - SIL-20A, SIL-20AC, Rack Changer, Rack Changer/C<br />

— Column Oven - CTO-20A, CTO-20AC<br />

— Detector - SPD-20A, SPD-20AV, SPD-M20A (PDA)<br />

— Solenoid valve - LPGE unit built in LC-20AD/20AT<br />

— Rotary valve - FCV-12AH installed in CTO-20A/20AC<br />

— Rotary valve - FCV-14AH installed in CTO-20A/20AC<br />

— Analog input - PC-55N<br />

32


Shimadzu GC<br />

� GC System Shimadzu GC-2010<br />

� GC System Shimadzu GC-2010 Plus<br />

� GC System Shimadzu GC-2014<br />

� GC Autosampler Shimadzu AOC-20i<br />

� GC Autosampler Shimadzu AOC-20i/s<br />

©2011 <strong>Waters</strong> Corporation<br />

33


PerkinElmer Clarus GC<br />

� PerkinElmer Clarus 400 GC<br />

� PerkinElmer Clarus 500 GC<br />

� PerkinElmer Clarus 600 GC<br />

©2011 <strong>Waters</strong> Corporation<br />

34


Perkin Elmer GC and HS<br />

•TurboMatrix Headspace samplers<br />

©2011 <strong>Waters</strong> Corporation<br />

35


Hitachi LaChrom Elite Systems<br />

� LaChrom Elite System drivers available from Hitachi<br />

� Availability expected 4Q, 2007<br />

� Supported Modules<br />

©2011 <strong>Waters</strong> Corporation<br />

— L-2100 and L-2130 - Pump<br />

— L-2200 - Autosampler<br />

— L-2300 and L-2350 - Column Oven<br />

— L-2400 - UV Detector<br />

— L-2420 - UV / Vis Detector<br />

— L-2450 and L-2455 - Diode Array Detector<br />

— L-2480 and L-2485 - Fluorescence Detector<br />

— L-2490 - Refractive Index Detector<br />

— AID - Analog Input Device (Single Channel)<br />

36


Hitachi LaChromUltra<br />

� Hitachi LaChromUltra L-2160U Pump<br />

� Hitachi LaChromUltra L-2200U Autosampler<br />

� Hitachi LaChromUltra L-2400U UV Detector<br />

� Hitachi LaChromUltra L-2420U UV-Vis Detector<br />

� Hitachi LaChrom L-2455U Diode Array Detector<br />

� Hitachi LaChromUltra L-2485U Fluorescence Detector<br />

©2011 <strong>Waters</strong> Corporation<br />

37


ESA Biosciences<br />

� ESA pump,<br />

� ESA Coulochem III electrochemical detector,<br />

� ESA Corona, Corona Plus, Corona Ultra CAD detectors,<br />

� CAD v1.23 Detector<br />

� Corona Plus V1.23<br />

� Corona Ultra V1.05<br />

©2011 <strong>Waters</strong> Corporation<br />

38


Dionex UltiMate 3000/<br />

� UltiMate 3000/3000 RSLC LPG-3400SD Quaternary Analytical pump<br />

� UltiMate 3000/3000 RSLC LPG-3400BM Quaternary Biocompatible Micro pump<br />

� UltiMate 3000/3000 RSLC DGP-3600 pumps<br />

� UltiMate 3000/3000 RSLC DGP-3600RS rapid separation dual low-pressure gradient pump<br />

� UltiMate 3000/3000 RSLC DGP-3600SD analytical dual low-pressure gradient pump<br />

� UltiMate 3000/3000 RSLC DGP-3600BM biocompatible dual low-pressure gradient pump<br />

� UltiMate 3000/3000 RSLC HPG-3x00 pumps<br />

� UltiMate 3000/3000 RSLC HPG-3x00RS rapid separation high-pressure gradient pump<br />

� UltiMate 3000/3000 RSLC HPG-3x00SD analytical high-pressure gradient pump<br />

� UltiMate 3000/3000 RSLC ISO-3100 pumps<br />

� UltiMate 3000/3000 RSLC ISO-3100SD analytical isocratic pump<br />

� UltiMate 3000/3000 RSLC ISO-3100BM biocompatible isocratic micro pump<br />

� UltiMate 3000/3000 RSLC FLM-3x00 flow managers and termostatted column compartments<br />

� UltiMate 3000/3000 RSLC TCC-3X00(RS) thermostatted column compartments<br />

� UltiMate 3000/3000 RSLC ACC-3000 autosampler column compartment<br />

� UltiMate 3000/3000 RSLC WPS-3000(RS) autosamplers<br />

� UltiMate 3000/3000 RSLC DAD-3000(RS) diode-array detector<br />

� UltiMate 3000/3000 RSLC FLD-3x00(RS) fluorescence detector<br />

� UltiMate 3000/3000 RSLC MWD-3000(RS) multi-wavelength detector<br />

� UltiMate 3000/3000 RSLC VWD-3x00(RS) variable-wavelength detectors<br />

©2011 <strong>Waters</strong> Corporation<br />

39


Dionex IC systems<br />

� Control of Dionex range of IC systems under development<br />

©2011 <strong>Waters</strong> Corporation<br />

— ICS-5000 Reagent-Free IC System<br />

— ICS-2100 Integrated Reagent-Free IC System<br />

— ICS-1600 Standard Integrated IC System<br />

— ICS-1100 Basic Integrated IC System<br />

— ICS-900 Starter Line IC System<br />

40


Extended Instrument Control with<br />

Empower <strong>Software</strong><br />

� Benefit to the Users: One <strong>Software</strong> solution for all<br />

chromatographic systems<br />

©2011 <strong>Waters</strong> Corporation<br />

— Reduced Training, Validation and Support<br />

� Instrument Control Available Today<br />

— 16 Vendors with 235+ Instrument modules<br />

— Major LC and GC Vendors<br />

� New Techniques<br />

— Supercritical Fluid <strong>Chromatography</strong> (SFC)<br />

— Capillary Electrophoresis (CE)<br />

41


©2011 <strong>Waters</strong> Corporation<br />

42

Hooray! Your file is uploaded and ready to be published.