UV- TECHNOLOGY Technical Documentation ELC PE22 / PE32
UV- TECHNOLOGY Technical Documentation ELC PE22 / PE32
UV- TECHNOLOGY Technical Documentation ELC PE22 / PE32
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
6 <strong>Technical</strong> Data page 30<br />
6 <strong>Technical</strong> Data<br />
General data <strong>ELC</strong><br />
Power choke Uk = 4%<br />
Power factor Typ. 0.88<br />
at Uk = 4% of the upstream power choke<br />
Power efficiency Typ. 0.94<br />
Mains frequency 50 / 60 Hz<br />
Tolerance mains voltage nominal voltage ± 10 %<br />
Recommended air throughput<br />
for cabinet ventilation<br />
<strong>ELC</strong> <strong>PE22</strong>_<strong>PE32</strong>-V2.2-09.11-GB Subject to technical alterations<br />
300 m 3 / h per <strong>ELC</strong> installed at ∆T = 10 K<br />
Control range approx. 20 - 100 %<br />
Firing voltage / duration < 3500 V / < 1 sec.<br />
Protection IP 20<br />
Permissible pollution pollution severity 2 according to VDE 0110<br />
Permissible humidity relative atmospheric humidity 80 %, non-condensing<br />
Dimensions (H x W x D) approx. 650 x 261 x 484 mm<br />
Installation position vertical (lamp and power connection at the top; control connections at the<br />
bottom) or horizontal respecting the minimum spacing in 3.1<br />
Baud rate Tested up to 500kBit<br />
EMC EN 55011<br />
EN 61000-3-3<br />
EN 61000-6-2<br />
Safety EN 50178<br />
Leakage current Leakage current > 3 mA, see chapter 1 “Safety“