17.01.2013 Views

Conductix-Wampfler Cables for Reeling Systems

Conductix-Wampfler Cables for Reeling Systems

Conductix-Wampfler Cables for Reeling Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Conductix</strong>-<strong>Wampfler</strong> Cable WG / WG-D<br />

Technical data<br />

Electrical<br />

parameters<br />

Thermal<br />

parameters<br />

Mechanical<br />

parameters<br />

Chemical<br />

parameters<br />

Materials<br />

Design<br />

features<br />

rated voltage Uo/U 3.6 / 6.0 kV 6.0 / 10.0 kV 8.7 / 15.0 kV 12.0 / 20.0 kV<br />

maximum permitted AC operating voltage Uo/U 4.2 / 7.2 kV 7.0 / 12.0 kV 10.2 / 18.0 kV 14.0 / 24.0 kV<br />

maximum permitted DC operating voltage Uo/U 5.4 / 10.8 kV 9.0 / 18.0 kV 13.0 / 26.0 kV 18.0 / 36.0 kV<br />

ampacity according to table data, otherwise according to DIN VDE 0298 part 4<br />

AC test voltage according to DIN VDE 0250 part 813<br />

ambient temperature<br />

flexing-25°C to + 80°C<br />

fixed -40°C to + 80°C<br />

maximum permitted operating temperature of the conductor 90°C<br />

short-circuit temperature of the conductor 250°C<br />

12 x Ø on the reel<br />

minimum bending radii allowing <strong>for</strong> free movement<br />

15 x Ø at a track curve<br />

20 x Ø at an S-track curve<br />

torsional stress ± 100 °/m<br />

tensile load-bearing capacity 20 N/mm2 conductor cross section during operation <strong>for</strong> flexing cables<br />

LBS-free / silicone-free yes<br />

combustion behaviour<br />

flame retardant and self-extinguishing<br />

according to DIN VDE 0482 part 265-2-1, IEC 60332-1<br />

resistant to ozone yes<br />

UV-resistant yes<br />

oil-resistant yes<br />

resistant to humidity yes<br />

Inner conducting layer consists of a semiconducting rubber, compound (according<br />

insulation<br />

to DIN VDE 0207 part 20), outer conducting layer of conducting rubber, to be able<br />

to be stripped cold (simple stripping method)<br />

Inner sheath consisting of a special red EPR compound, 5GM3,<br />

with polyester rein<strong>for</strong>ced braid <strong>for</strong> protection against torsional <strong>for</strong>ces. Braid is<br />

sheathing system<br />

vulcanized between the inner and outer sheaths<br />

in a sandwich structure. Outer sheath of abrasion-resistant PCP based compound<br />

offering excellent resilience, 5GM5<br />

conductor<br />

electrolytic copper, flexible conductor<br />

category 5, according to DIN VDE 0295<br />

conductors in layers stranded with small lay, earth conductor divided into three<br />

stranding<br />

parts in the interstices (without optic fibers) or two halfes in the interstices (with<br />

optic fibers)<br />

conductor coding black insulation with white numbers<br />

Standards acording to DIN VDE 0250 part 813<br />

Design<br />

codes<br />

Fiber optic<br />

R-(N)TSCGEWOEU<br />

R-(N)TSCGEWOEU-FO<br />

fiber type (core-Ø / fiber-Ø)<br />

damping at 850 nm<br />

at 1300 nm<br />

at 1550 nm<br />

numeric aperture<br />

dispersion at 1300 nm<br />

at 1550 nm<br />

band width at 850 nm<br />

at 1300 nm<br />

R- cable suitable <strong>for</strong> use on reels<br />

(N) adapted to a standard<br />

TS heavy duty cable<br />

CGE conducting non-metallic covering surrounding the insulation<br />

of the outer conductors<br />

W resistant to atmospheric corrosion<br />

OE oil-resistant outer sheath<br />

U outer sheath of low flammability<br />

according to DIN VDE 0472 part 804 (fire-proof)<br />

FO with fiber optic<br />

Mono-Mode<br />

Multi-Mode<br />

Multi-Mode<br />

E9/125<br />

-<br />

0.4 dB/km<br />

0.3 dB/km<br />

-<br />

3.5 ps/nm km<br />

18.0 ps/nm km<br />

400 MHz km<br />

60 - 1.500 MHz km<br />

<strong>Conductix</strong>-<strong>Wampfler</strong> <strong>Cables</strong> <strong>for</strong> Basic <strong>Reeling</strong><br />

50/125<br />

2.8 dB/km<br />

0.8 dB/km<br />

-<br />

0.20 ± 0.02<br />

-<br />

-<br />

400 MHz km<br />

60 - 1.500 MHz km<br />

62.5/125<br />

3.3 dB/km<br />

0.9 db/km<br />

-<br />

0.27 ± 0.02<br />

-<br />

-<br />

200 MHz km<br />

600 MHz km<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!