<strong>Twin</strong> <strong>Disc</strong>, Incorporated Disassembly<br />

Power Take-off Service Manual<br />

Disassemble the second tower (in the same manner as steps 2 through 9).<br />

10. If a pump is mounted on the tower, remove 4 hex head capscrews (102)<br />

and pull the pump (109) and gasket (101) from the tower.<br />

11. If there is no pump mounted on the tower, remove 4 hex head capscrews<br />

(82) and remove the cover (94) with gasket (81) from the tower.<br />

12. Remove 6 hex head capscrews (79) with copper washers (80) and<br />

remove the SAE mounting plate (78) with plate gasket (77) from the<br />

gear tower.<br />

13. Remove the driven gear (83) with ball bearings (76 & 84) from the<br />

housing.<br />

14. Remove 4 hex head capscrews (75) and remove the cover (74) with<br />

cover gasket (73) from the other side of the tower.<br />

15. Remove 6 hex head capscrews (71) with copper washers (72) and<br />

remove the SAE mounting plate (70) with plate gasket (69) from the<br />

tower.<br />

16. Using a bearing puller, remove the ball bearings ( 76 & 84) from the<br />

driven gear (108).<br />