S8(a): End Support Details – Fixings Notes<br />
Fixing Notes<br />
Unless specified otherwise fixings shall be as follows:<br />
(A) - When supporting trusses via Bot<strong>to</strong>m chords<br />
each Truss Bot<strong>to</strong>m Chord shall be held on<strong>to</strong> its<br />
supporting plate/bearer by a minimum of 2/75 x 3.15<br />
mm dia. nails. If preferred, a better fixing may be<br />
achieved by using on Pryda Multigrip Long with 3/35<br />
x 3.15mm dia. Pryda nails per tab.<br />
(B) PrydaSpan truss boundary stringer <strong>to</strong>;<br />
a) stringer attached <strong>to</strong> supporting steel beam or<br />
b) continuous timber bearer fix using a minimum 90 x<br />
M8 Coach Screw @ 500mm centres.<br />
(C) Upper wall Bot<strong>to</strong>m Plate (BPL) <strong>to</strong> PrydaSpan truss<br />
Top Chord (TC) - use 1/100mm washered Drive Pin<br />
@ 600mm centres.<br />
(D) For continuous floor over load bearing wall -<br />
stringer <strong>to</strong> stringer - use minimum 90 x M8 Coach<br />
Screw @ 500mm centres between edge truss or joist<br />
and <strong>to</strong>p chord of adjoining truss.<br />
(E) Module <strong>to</strong> Module Edge Fixing - use minimum 90<br />
x M8 coach Screw @ 500mm centres between edge<br />
truss or joist and <strong>to</strong>p chord of adjoining truss.<br />
(F) Fixing for diaphragm action not included.<br />
Diaphragm action fixings and details need <strong>to</strong> be<br />
specifically designed.<br />
“Fixings Notes” above are for Residential Application i.e. Floor Load = 1.5kPa / 1.8kN).<br />
For other applications contact the “<strong>Reid</strong> <strong>Construction</strong> <strong>Systems</strong>” Engineering Design office on 0800 88 22 12.<br />