S3: Fire Rating<br />

The Flexus Modular Flooring System comprises of two<br />

main elements, a support structure and a floor <strong>to</strong>pping.<br />

The support structure is either a timber or steel joist or<br />

timber truss layout as per a normal built up floor.<br />

The plywood or particle board sheet flooring of a built<br />

up floor is replaced by a monolithic cementatious floor<br />

sheet (Flexus material) that spans the length of the<br />

joists and up <strong>to</strong> 2400mm in width.<br />

The whole of the Flexus floor sheet (span x width) is<br />

made as a module complete with the supporting truss<br />

or joist system in a fac<strong>to</strong>ry environment and delivered <strong>to</strong><br />

site ready for installation.<br />

Once the Flexus flooring modules are in place and<br />

secured, services can be run through the floor space<br />

and a ceiling installed <strong>to</strong> the underside of the modules.<br />

For fire rating we follow the recommendations of the<br />

Wins<strong>to</strong>ne Wallboards Ltd publication Gib® Fire Rated<br />

<strong>Systems</strong> for fire rated floor/ceiling systems and any<br />

specific recommendations from the joist/truss supplier/<br />

manufacturer.<br />

Gib® fire rated systems use a 20mm particle board<br />

floor or a 17mm plywood floor as a minimum.<br />

The Flexus floor sheet is a non combustible<br />

cementitious material 30mm thick. By common<br />

engineering knowledge of materials, Flexus has a<br />

superior fire resistance than the wood based thinner<br />

materials used for the Gib® fire rating. Therefore, <strong>Reid</strong><br />

are comfortable using in accordance for the situation,<br />

the fire ratings for Gib® board ceilings as per the Gib®<br />

Fire Rated <strong>Systems</strong> publication for Flexus flooring<br />

modules until specific fire tests are completed.<br />

Flexus Modular Flooring System can be used <strong>to</strong><br />

provide passive fire protection in accordance with the<br />

requirements of NZBC Clause C3 – Spread of Fire.<br />

In order <strong>to</strong> satisfy the requirements of NZBC Clause C4<br />

– Structural Stability during Fire, designers must ensure<br />

that fire rated elements are supported by elements<br />

having at least the same Fire Resistance Rating (FRR).<br />

Collapse of elements having a lesser FRR shall not<br />

cause the consequential collapse of elements required<br />

<strong>to</strong> have a higher FRR.<br />

Underneath a Flexus Floor with open webs<br />