Overview of dimm<strong>in</strong>g HID system<br />

SON lamps can be dimmed on EM and EL systems. CDO, CDMe and CPO lamps can be dimmed on<br />

EL only!<br />

The optimal method of dimm<strong>in</strong>g is with electronics.<br />

Please al<strong>low</strong> 2-5 m<strong>in</strong>utes <strong>for</strong> any system to dim down from 100% to the m<strong>in</strong>imum (al<strong>low</strong>ed) level<br />

EL high-frequency dimm<strong>in</strong>g could <strong>in</strong>troduce resonance <strong>in</strong>to the discharge arc, which could result <strong>in</strong> a<br />

disruptive end-of-lamplife, and is there<strong>for</strong>e not recommended.<br />

<strong>Philips</strong> can offer an electronic dimmable driver <strong>for</strong> all new outdoor HID lamps.<br />

• The new CDO lamps can be dimmed us<strong>in</strong>g <strong>Philips</strong> <strong>Xtreme</strong> <strong>drivers</strong>.<br />

• CDO lamps cannot be dimmed <strong>in</strong> comb<strong>in</strong>ation with EM gear.<br />

Dim level/ lamp type<br />

SON<br />

CDO<br />

CPO<br />

Dimm<strong>in</strong>g<br />

Method<br />

M<strong>in</strong> dim level Ra Tc Lifetime (5%) Ma<strong>in</strong>tenance Time<br />

Types Power Light 100% M<strong>in</strong> 100% M<strong>in</strong> 100% Max Max dimmed<br />

to dim<br />

level<br />

level<br />

dimmed<br />

50% of life<br />

50% of life<br />

Elect 50W 60% 50% 20 8.000 >70% 4 m<strong>in</strong><br />

Elect 45W 66% 55% 65 60 2.800 2.800 16.000 16.000 80% 2 m<strong>in</strong><br />

Elect 60W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 m<strong>in</strong><br />

Elect 90W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 m<strong>in</strong><br />

Elect 140W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 m<strong>in</strong><br />

Elect 210W 60% 50% 90 80 3.000 3.000 16.000 16.000 80% 2 m<strong>in</strong><br />

Note: It is strongly recommended that an EMC filter should be used <strong>in</strong> order to provide sufficient design-<strong>in</strong> marg<strong>in</strong><br />

concern<strong>in</strong>g EMC per<strong>for</strong>mance <strong>in</strong> case a comb<strong>in</strong>ation of CDO 50W gear and a CDO 50W lamp is used. Please<br />

contact your <strong>Philips</strong> salesperson <strong>for</strong> more <strong>in</strong>fo on what sort of filters should be used <strong>for</strong> these circumstances.<br />

37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!