CVS2·CVS22-05·10Series - Romicon
CVS2·CVS22-05·10Series - Romicon
CVS2·CVS22-05·10Series - Romicon
- TAGS
- romicon
- www.romicon.nl
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CVS2·CVS22</strong>-05·10 2-port solenoid valve Series for coolant : Normally closed, normally open<br />
JIS symbol<br />
· NC type<br />
X OUT<br />
· NO type<br />
516<br />
IN<br />
Y OUT<br />
IN<br />
LOW PRESSURE COOLANT VALVE CVS2/CVS22-05/10 SERIES<br />
• For 0.5MPa/1.0MPa<br />
• Port size : Rc3/8, Rc1/2, Rc3/4, Rc1, Rc11 /4, Rc11 /2, Rc2, Flange 32, 40, 50, 65, 80<br />
Common specifications for 0.5MPa<br />
Series<br />
CVS2 CVS22<br />
Coolant<br />
mm 500 or less<br />
0 to 0.5<br />
2.0<br />
-10 to 60 (no freezing)<br />
-10 to 60<br />
20 or less (under water pressure)<br />
Free<br />
0.25 to 0.7<br />
1 or less (copper tube 30m, full pressure 0.5MPa)<br />
2 /S<br />
MPa<br />
MPa<br />
°C<br />
°C<br />
cm3 Actuation<br />
Normally closed (NC type) Normally open (NO type)<br />
Working fluid<br />
Fluid viscosity<br />
Working pressure range<br />
Withstanding pressure (water)<br />
Fluid temperature<br />
Ambient temperature<br />
Valve seat leakage /min<br />
Installation attitude<br />
Pirot air pressure MPa<br />
Water hammer value (references) MPa<br />
Electrical specifications<br />
Rated voltage<br />
AC100V(50/60Hz) /110V(60Hz), AC200V(50/60Hz)/220V (60Hz), DC24V<br />
Apparent power Holding<br />
3.9VA(50Hz), 3.1VA(60Hz)<br />
(VA) Starting<br />
9.2VA(50Hz), 7.9VA(60Hz)<br />
Power consumption AC<br />
2.0W(50Hz), 1.7W(60Hz)<br />
(W) DC<br />
4.0W<br />
Insulation class<br />
Class B<br />
Protection structure<br />
Grommet lead wire<br />
IPX2<br />
(IEC standards 529)<br />
DIN terminal box (Pg9)<br />
IPX5<br />
T terminal box (G1/2)<br />
IPX6<br />
· 1: Allowable voltage range should be within ±10% of rated voltage.<br />
Switch specifications<br />
Applications Programmable controller<br />
Programmable controller, relay<br />
IC circuit, small solenoid valve<br />
Power voltage<br />
-<br />
DC10 to 28V<br />
Load voltage/current DC10 to 30V, 5 to 30mA<br />
DC30V, 150mA or less<br />
Light<br />
LED (ON lighting)<br />
Maximum shock resistance<br />
30G<br />
· 2 : See P.558 about other switch specifications.<br />
Rc3/8<br />
Rc1/2<br />
Rc3/4<br />
Rc1<br />
Rc11 /4<br />
Flange 32<br />
Rc11 Individual specifications for 0.5MPa<br />
Descriptions<br />
Series<br />
Port size Orifice (mm)<br />
Cv flow<br />
factor<br />
Pilot port size Mass (kg)<br />
CVS2/CVS22-10A-05<br />
10<br />
1.8<br />
Rc1/8<br />
0.4<br />
CVS2/CVS22-15A-05<br />
14<br />
5<br />
0.75<br />
CVS2/CVS22-20A-05<br />
19<br />
8<br />
1.1<br />
CVS2/CVS22-25A-05<br />
24<br />
12<br />
1.6<br />
CVS2/CVS22-32A-05<br />
31<br />
20<br />
2.9<br />
CVS2/CVS22-32F-05<br />
31<br />
20<br />
5.4<br />
CVS2/CVS22-40A-05<br />
/2<br />
40<br />
32<br />
Rc1/4<br />
4.6<br />
CVS2/CVS22-40F-05<br />
Flange 40<br />
40<br />
32<br />
7.1<br />
CVS2/CVS22-50A-05<br />
Rc2<br />
50<br />
50<br />
7.7<br />
CVS2/CVS22-50F-05<br />
Flange 50<br />
50<br />
50<br />
10.9<br />
CVS2/CVS22-65F-05<br />
Flange 65<br />
65<br />
70<br />
19.5<br />
CVS2/CVS22-80F-05<br />
Flange 80<br />
79<br />
100<br />
24.0<br />
CAD DATA AVAILABLE.<br />
C2 C3
Common specifications for 1.0MPa<br />
Series<br />
CVS2 CVS22<br />
Coolant<br />
mm 500 or less<br />
0 to 1.0<br />
2.0<br />
-10 to 60 (no freezing)<br />
-10 to 60<br />
20 or less (under water pressure)<br />
Free<br />
0.25 to 0.7<br />
1 or less (copper tube 30m, full pressure 0.5MPa)<br />
2 /S<br />
MPa<br />
MPa<br />
°C<br />
°C<br />
cm3 Actuation<br />
Normally closed (NC type) Normally open (NO type)<br />
Working fluid<br />
Fluid viscosity<br />
Working pressure range<br />
Withstanding pressure (water)<br />
Fluid temperature<br />
Ambient temperature<br />
Valve seat leakage /min<br />
Installation attitude<br />
Pirot air pressure MPa<br />
Water hammer value (references) MPa<br />
Water Electrical hammer specifications<br />
value (references)<br />
Rated voltage<br />
AC100V(50/60Hz) /110V(60Hz), AC200V(50/60Hz)/220V (60Hz), DC24V<br />
Apparent power Holding<br />
3.9VA(50Hz), 3.1VA(60Hz)<br />
(VA) Starting<br />
9.2VA(50Hz), 7.9VA(60Hz)<br />
Power consumption AC<br />
2.0W(50Hz), 1.7W(60Hz)<br />
(W) DC<br />
4.0W<br />
Insulation class<br />
Class B<br />
Protection structure<br />
Grommet lead wire<br />
IPX2<br />
(IEC standards 529)<br />
DIN terminal box (Pg9)<br />
IPX5<br />
T terminal box (G1/2)<br />
IPX6<br />
· 1: Allowable voltage range should be within ±10% of rated voltage.<br />
Switch specifications<br />
Applications Programmable controller<br />
Programmable controller, relay<br />
IC circuit, small solenoid valve<br />
Power voltage<br />
-<br />
DC10 to 28V<br />
Load voltage/current<br />
DC10 to 30V, 5 to 30mA<br />
DC30V, 150mA or less<br />
Light<br />
LED (ON lighting)<br />
Maximum shock resistance<br />
30G<br />
· 2 : See P.558 about other switch specifications.<br />
Individual specifications for 1.0MPa<br />
Descriptions<br />
Series<br />
CVS2/CVS22-10A-10<br />
CVS2/CVS22-15A-10<br />
CVS2/CVS22-20A-10<br />
CVS2/CVS22-25A-10<br />
CVS2/CVS22-32A-10<br />
CVS2/CVS22-32F-10<br />
CVS2/CVS22-40A-10<br />
CVS2/CVS22-40F-10<br />
CVS2/CVS22-50A-10<br />
CVS2/CVS22-50F-10<br />
CVS2/CVS22-65F-10<br />
CVS2/CVS22-80F-10<br />
C2 C3<br />
Rc3/8<br />
Rc1/2<br />
Rc3/4<br />
Rc1<br />
Rc11 /4<br />
Flange 32<br />
Rc11 /2<br />
Flange 40<br />
Rc2<br />
Flange 50<br />
Flange 65<br />
Flange 80<br />
7<br />
10<br />
14<br />
17<br />
23<br />
23<br />
29<br />
29<br />
35<br />
35<br />
49<br />
57<br />
<strong>CVS2·CVS22</strong>-05·10 Series<br />
Port size Orifice (mm) Cv flow factor Pilot port size Mass (kg)<br />
1.3<br />
3.5<br />
5.5<br />
7.5<br />
14<br />
14<br />
23<br />
23<br />
34<br />
34<br />
50<br />
73<br />
Rc1/8<br />
Rc1/4<br />
0.4<br />
0.75<br />
1.1<br />
1.6<br />
2.9<br />
5.4<br />
4.6<br />
7.1<br />
7.7<br />
10.9<br />
19.5<br />
24.0<br />
517<br />
Coolant valve
<strong>CVS2·CVS22</strong>-05·10 Series<br />
How to order<br />
· Solenoid valve mounted type<br />
518<br />
CVS2<br />
Series<br />
2<br />
32A<br />
· Switch mounted solenoid valve<br />
CVS2 2 15A 05 0 2G S<br />
A Actuation<br />
B Port size<br />
10 0 2C S<br />
1<br />
Symbol<br />
A Blank<br />
2<br />
B<br />
10A<br />
15A<br />
20A<br />
25A<br />
32A<br />
32F<br />
40A<br />
40F<br />
50A<br />
50F<br />
65F<br />
80F<br />
05<br />
10<br />
Descriptions<br />
Normally closed (NC type)<br />
Normally open (NO type)<br />
Rc3/8<br />
Rc1/2<br />
Rc3/4<br />
Rc1<br />
Rc1 1 /4<br />
Flange 32<br />
Rc1 1 /2<br />
Flange 40<br />
Rc2<br />
Flange 50<br />
Flange 65<br />
Flange 80<br />
0 to 0.5MPa<br />
0 to 1.0MPa<br />
C Working pressure range<br />
C<br />
D Body/Sealing<br />
D<br />
0<br />
Body Seal<br />
STD Cast iron Nitrile rubber<br />
B Option Cast iron Fluoro rubber<br />
E Coil<br />
E<br />
2C<br />
2G<br />
2H<br />
STD Grommet lead wire<br />
DIN terminal box (Pg9)<br />
DIN terminal box + light (Pg9)<br />
3T T terminal box (G1/2)<br />
3R<br />
T terminal box + light (G1/2)<br />
F Other options<br />
F<br />
Blank No options<br />
S Surge suppressor<br />
·1<br />
B Mounting plate<br />
·2<br />
·3<br />
·4<br />
G Switch quantity<br />
·5<br />
G<br />
Blank No switch<br />
X No switch but w/detecting magnet<br />
H Detection at valve open<br />
R Detection at valve closed<br />
D 2 switches<br />
H Switch model No.<br />
H<br />
Blank No switch<br />
C2 Proximity/2 wire<br />
·6<br />
C3 Proximity/3 wire<br />
I Switch lead<br />
I<br />
Blank No switch<br />
3 3m<br />
wire length<br />
5 5m<br />
J Voltage<br />
J 1<br />
2<br />
AC100V(50/60Hz)<br />
AC110V(60Hz)<br />
AC200V(50/60Hz)<br />
AC220V(60Hz)<br />
3 DC24V<br />
shows availability.<br />
<br />
CVS22-15A-05-02GS-HC23-1<br />
Series : CVS2<br />
A Actuation : Normally open (NO type)<br />
B Port size : Rc1/2<br />
C Working pressure range : 0 to 0.5MPa<br />
D Body/Sealing : Body- cast iron/Sealing- nitrile<br />
E Coil : DIN terminal box (Pg9)<br />
F Other options : Surge suppressor<br />
G Switch quantity : Detection at valve open<br />
H Switch model No. : Proximity 2 wire<br />
I Switch lead wire : 3m<br />
J Voltage : AC100V(50/60Hz)AC110V(60Hz)<br />
H C2 3 1<br />
·1 : Mounting plate ("F" is B) is available for port size 10A, 15A, 20A and 25A.<br />
·2 : When selecting both surge suppressor and mounting plate options, indicate "F" as SB.<br />
·3 : When lead wire coil, surge suppressor is attached, while terminal box coil, mounted in the terminal box.<br />
·4 : When with mounting plate, since any switch cannot be installed on the mounting plate end, switch quantity should be X, H or R.<br />
·5 : When "G" is blank, any switch cannot be installed later. If switches will be installed later, indicate "G" as X.<br />
·6 : See P.558 about switch model.<br />
Port size<br />
Coil<br />
Switch quantity<br />
Voltage<br />
Option<br />
Series<br />
CVS2/CVS22 CVS2/CVS22<br />
–with switch
Internal structure and main parts materials<br />
· CVS2<br />
Dimensions<br />
· CVS2/CVS22-10A to 50A-05/10- * 2C H C2 3<br />
R C3 5<br />
D<br />
·1: : Rc1/8 when 10A.<br />
Model<br />
CVS2 * -10A-05/10- * 2C<br />
CVS2 * -15A-05/10- * 2C<br />
CVS2 * -20A-05/10- * 2C<br />
CVS2 * -25A-05/10- * 2C<br />
CVS2 * -32A-05/10- * 2C<br />
CVS2 * -40A-05/10- * 2C<br />
CVS2 * -50A-05/10- * 2C<br />
8<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
OUT<br />
M5<br />
Exhaust port<br />
HD<br />
(300) 19 16<br />
A<br />
Port X<br />
Switch indicator<br />
light<br />
C<br />
D<br />
IN<br />
(Rc screw in)<br />
E<br />
6<br />
<strong>CVS2·CVS22</strong>-05·10 Series<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Detection at<br />
valve open<br />
Parts name<br />
Piston<br />
Adapter<br />
Piston rod<br />
Main valving element<br />
Body<br />
Valve seat<br />
Spring<br />
Cylinder cover<br />
Pilot solenoid valve<br />
Material<br />
A2011<br />
SUS303<br />
SUS304<br />
SUS440<br />
FCD450<br />
SUS440<br />
SWP<br />
ADC12<br />
-<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
Aluminum<br />
Stainless steel<br />
Stainless steel<br />
Stainless steel<br />
Cast iron<br />
Stainless steel<br />
Piano wire<br />
Aluminum die-casting<br />
50 24 12 60 121<br />
32 Rc3/8<br />
71 29 14.5 85.5 148<br />
45 Rc1/2<br />
80 36 18 99 161.5 53 Rc3/4<br />
90 43 21.5 113.5 176<br />
63 Rc1<br />
125 55 27.5 148 211<br />
78 Rc1<br />
140 61 30.5 165 228<br />
95<br />
160 76 38 207.5 270.5 115<br />
1 /4<br />
Rc11 A B C D E F G HD RD<br />
- -<br />
14<br />
7.7<br />
(7.7) ·3<br />
16<br />
8.7<br />
(10.2) ·3<br />
17<br />
8.7<br />
(9.7) ·3<br />
25.5<br />
16.8<br />
(18.8) ·3<br />
/2 28.5<br />
16.8<br />
(19.3) ·3<br />
·2 : HD, RD dimensions show reference values.<br />
·3 : Dimensions in ( ) show the value for 1MPa.<br />
Rc2 32.5<br />
18.8<br />
(21.8) ·3<br />
G<br />
7<br />
25<br />
B<br />
F<br />
3<br />
Rc1/4 (* 1)<br />
7<br />
RD<br />
Detection at valve closed<br />
519<br />
Coolant valve
<strong>CVS2·CVS22</strong>-05·10 Series<br />
· CVS2/CVS22-32F/40F/50F-05/10- * 2C H C2 3 (flange)<br />
R C3 5<br />
D<br />
· CVS2/CVS22-65F/80F-05- * 2C H C2 3 (flange)<br />
R C3 5<br />
D<br />
520<br />
M5<br />
Exhaust port<br />
HD<br />
Model<br />
CVS2 * -32F-05/10- * 2C<br />
CVS2 * -40F-05/10- * 2C<br />
CVS2 * -50F-05/10- * 2C<br />
170<br />
180<br />
180<br />
·1: HD, RD dimensions show reference values.<br />
·2 : Dimensions in ( ) show the value for 1MPa.<br />
Switch indicator light<br />
Model<br />
CVS2 * -65F-05/10- * 2C<br />
CVS2 * -80F-05/10- * 2C<br />
(300) 19 16<br />
·1: HD, RD dimensions show reference values.<br />
A<br />
A<br />
A D E H K L M HD RD<br />
210<br />
240<br />
Switch indicator light<br />
M<br />
188<br />
204.5<br />
247<br />
M<br />
297.5<br />
317.5<br />
HD<br />
H dia.<br />
251<br />
267.5<br />
310<br />
395<br />
415<br />
Detection at<br />
valve open<br />
135<br />
140<br />
155<br />
Detection at valve open<br />
H dia.<br />
175<br />
185<br />
7<br />
7 7<br />
4- 19 dia.<br />
36<br />
42<br />
54<br />
68<br />
82<br />
100<br />
105<br />
120<br />
140<br />
150<br />
12<br />
12<br />
14<br />
16<br />
16<br />
25.5<br />
28.5<br />
32.5<br />
47<br />
52<br />
16.8<br />
(18.8) ·2<br />
16.8<br />
(19.3) ·2<br />
18.8<br />
(21.8) ·2<br />
A D E H K L M HD RD<br />
25<br />
3<br />
L dia.<br />
K dia.<br />
Rc1/4<br />
Detection at valve closed<br />
RD<br />
7<br />
D<br />
E<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
M5<br />
18 Exhaust port<br />
Rc1/4<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
X<br />
Y<br />
L dia.<br />
K dia.<br />
65F: 4- 19 dia.<br />
80F: 8- 19 dia.<br />
RD<br />
D<br />
Detection at valve closed<br />
E<br />
30.3<br />
32.5
Optional dimensions<br />
· Mounting plate<br />
CVS2/CVS22-10A-05/10- * * B<br />
· DIN terminal box (Pg9)<br />
DIN terminal box with indicator light (Pg9)<br />
CVS2/CVS22- * -05/10- * 2G<br />
2H<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
15.5<br />
36.5<br />
Pg9<br />
Applicable cable<br />
(O.D. 4.5 to 7)<br />
IN port<br />
2- 6 dia.<br />
43.5<br />
·1<br />
53 16<br />
18<br />
50<br />
62<br />
2<br />
8<br />
31<br />
·1: When fixing without mounting plate, use set screws suit to the body. (Thread size : M5 depth 7)<br />
25<br />
<strong>CVS2·CVS22</strong>-05·10 Series<br />
· Mounting plate<br />
CVS2/CVS22-15A/20A/25A-05/10- * * B<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
9<br />
12<br />
N<br />
O<br />
Model<br />
CVS2 * -15A-05/10- * * B<br />
CVS2 * -20A-05/10- * * B<br />
CVS2 * -25A-05/10- * * B<br />
N O P Q R<br />
90<br />
95<br />
105<br />
70<br />
75<br />
85<br />
45<br />
50<br />
55<br />
· T type terminal box (G1/2)<br />
T type terminal box with indicator light (G1/2)<br />
CVS2/CVS22- * -05/10- * 3T<br />
3R<br />
P<br />
(File name : Page 559 to 560 or Ending 29 to 31)<br />
26<br />
36<br />
G1/2<br />
(84)<br />
(53)<br />
13<br />
16<br />
Q<br />
R<br />
35<br />
25<br />
2.3<br />
3.2<br />
3.2<br />
30<br />
40<br />
45<br />
521<br />
Coolant valve