Variable Displacement Pump KVA<br />
Sizes 55…107<br />
Axial tapered piston bent axis design<br />
Series 6<br />
Open circuits<br />
Nominal pressure 300 bar<br />
Peak pressure 350 bar<br />
Size 55 80 107<br />
Displacement V g max cm 3<br />
Speed 1)<br />
54,8 80 107<br />
at V g max n max rpm 2500 2240 2150<br />
Flow at n max q Vmax L/min 137 179 230<br />
Power �p = 300 bar P max kW 69 90 115<br />
Torque �p = 300 bar Tmax Nm 261 382 510<br />
Weight (approx.) m kg 16 20 24<br />
1)<br />
These values are valid at an absolute pressure of 1 bar in suction port S<br />
2)<br />
�p = 315 bar<br />
DRS<br />
Constant pressure control<br />
with load-sensing function<br />
p B<br />
V g min<br />
V gmax<br />
EP<br />
Electrical control with<br />
proportional solenoid<br />
I<br />
V g min<br />
Variable displacement pump for<br />
demanding applications and easy<br />
control of working equipment in<br />
commercial vehicles, e.g. HGV<br />
loading cranes, generator drives,<br />
compressor drives, drives for air<br />
conditioning systems, fan drives,<br />
etc.<br />
These pumps are suitable for<br />
current HGV European standard<br />
gearboxes and meet all the demands<br />
placed on hydraulic drives<br />
in these areas.<br />
V g max<br />
V g = Displacement<br />
p B = Working pressure<br />
I = Pilot current<br />
Detailed information:<br />
KVA RE 92 250<br />
KFA/KVA RE 98 207<br />
3) �p = 350 bar<br />
13<br />
1