Variable Displacement Double Pump A8VO<br />
Sizes 28…200<br />
Axial tapered piston bent axis design<br />
Series 6<br />
Open circuits<br />
Nominal pressure 350 bar<br />
Peak pressure 400 bar<br />
Variable displacement double<br />
pump for machines with multicircuit<br />
operation in the open circuit,<br />
such as excavators, cranes,<br />
drilling equipment, etc.<br />
The range of control equipment<br />
and the supplementary equipment<br />
are tailored to the specific requirements.<br />
Supplementary equipment:<br />
U Integrated auxiliary pump with<br />
pressure relief valve, optionally<br />
with additional pressure reducing<br />
valve<br />
U Power take-off for mounting<br />
gear pumps and axial piston<br />
pumps<br />
U Individual controller<br />
U Overload control<br />
U Power train<br />
U Hydraulic stroke limiter<br />
Detailed information:<br />
A8VO RE 93 010<br />
A7VO/A8VO RE 98 211<br />
Size 28 55 80 107140 200<br />
Displacement (per rotary group) Vg max cm 3<br />
28,1 54,8 80 107 140 200<br />
Speed 1) (i = 1) nmax rpm 2300 2)<br />
2500 2240 2150 2100 2100<br />
Flow at nmax qVmax L/min 2 x 88 2 x 137 2 x 179 2 x 230 2 x 294 2 x 420<br />
Power �p1 + �p2 = 700 bar Pmax kW 72,5 3)<br />
160 209 268 294 4)<br />
350 3)<br />
Torque �p1 + �p2 = 700 bar T max Nm 218 3)<br />
611 891 1192 1337 4)<br />
Weight (approx.) m kg 60 78 82 105 120 182<br />
1) These values are valid at an absolute pressure of 1 bar in suction port S 2) i = 0,73 3) �p1 + �p2 = 500 bar (Sizes 28, 200) 4) �p1 + �p2 = 600 bar (Size 140)<br />
SR<br />
Summation power controller<br />
(hyperbolic control),<br />
size 28<br />
p B1 + p B2<br />
V g mi n<br />
V g ma x<br />
LA0<br />
Individual power controller<br />
(spring control),<br />
sizes 55…200<br />
p B1 + p B2<br />
V g mi n<br />
V g ma x<br />
LA1<br />
Individual power controller<br />
with load limiting<br />
control (spring control),<br />
sizes 55…200<br />
p B1 + p B2<br />
V g mi n<br />
V g ma x<br />
p st<br />
1592 3)<br />
V g = Displacement<br />
p B1 = Working pressure, 1st pump<br />
p B2 = Working pressure, 2nd pump<br />
21<br />