94<br />

Fig. 3<br />

Changing subscriber categories from the<br />

operating centre<br />

trol system ANA 30 by means <strong>of</strong> alarms<br />

and printouts administered by the operation<br />

and maintenance processor,<br />

OMP.<br />

Faults in the switching system can also<br />

be found with the aid <strong>of</strong> ANA 30, since its<br />

printouts show the switching processes<br />

in the form <strong>of</strong> digits and control signals.<br />

Other printouts specify the device<br />

groups that exceed the permitted error<br />

level limits (STU, KS, KM). <strong>The</strong>se printouts<br />

can indicate faults in the switching<br />

system and the network.<br />

After the introduction <strong>of</strong> ANA 30 it has<br />

also been possibleto keep the switching<br />

system in better condition than before,<br />

since the latter system has gradually<br />

been adjusted to the exacting signalling<br />

and time conditions that apply for<br />

ANA 30.<br />

In spite <strong>of</strong> the fact that ANA 30 gives detailed<br />

fault information, the supplementary<br />

fault reports from the subscribers<br />

are <strong>of</strong> importance, for example<br />

when there is a fault in the signal reception<br />

from the push-button sets.<br />

Experience from ANA 30 in Arhus<br />

Centrum shows that after a running-in<br />

period the system is very reliable. <strong>The</strong><br />

operational statistics show that the duplication<br />

<strong>of</strong> most <strong>of</strong> the function units in<br />

ANA 30 ensures that large operational<br />

disturbances are to all intents and<br />

purposes eliminated.<br />

Saving in personnel<br />

By the middle <strong>of</strong> 1978 115 000 lines in<br />

the Arhus area were connected to<br />

ARE 11 exchanges with ANA 30. If these<br />

subscribers were to have been served by<br />

ARF 100 instead, 21 technicians would<br />

have been required for the operation<br />

and maintenance <strong>of</strong> the exchanges, not<br />

including the MDF staff.<br />

It is estimated that after the modernization<br />

with ANA 30 the number <strong>of</strong> technicians<br />

required will be reduced to 18, a<br />

saving <strong>of</strong> 3. Furthermore it is expected<br />

that the staff will be kept at this number<br />

during the coming years despite the fact<br />

that the number <strong>of</strong> subscribers is expected<br />

to increase by 8 % annually.<br />

In addition there is a saving <strong>of</strong> 1/2 man<br />

year per year because such administrative<br />

tasks as category changes, route<br />

changes etc. are carried out by means <strong>of</strong><br />

commands.