INSTRUCTIONS FOR USE<br />

<strong>BSB</strong> <strong>32</strong><br />

(patented)<br />

1. On the Coupling tool <strong>BSB</strong> <strong>32</strong>, set the mechanical expander (E) of the desired<br />

working diameter, checking that it has been screwed up to the stop.<br />

STOP<br />

NB1: In order to perform this operation, the<br />

equipment must be in a rest position.<br />

NB2: Check that the elastomeric adapter (F) is<br />

mounted on the mechanical expander (E) and that no<br />

tears or breaks are evident on the elastomeric<br />

adapter.<br />

The good shape of couplings is granted only if the<br />

adapter is in a good condition (for adapter removal<br />

and replacement, see "processing remarks").<br />

Do not use grease, soap, lubricating or sliding<br />

Picture 1<br />

products of any kind on the elastomeric adapter (F).<br />

Warning: When mounting the mechanical expander, make sure that the<br />

equipment is not connected to the power supply source (battery or outlet).<br />

2. Cut the pipe perpendicularly and with care, then insert the cap into it.<br />

NB: To avoid damage to pipe heads, make sure that the shearing or pipe-cutting<br />

blades are in good working order.<br />

YES NO Picture 2<br />

3. Insert the pipe into the mechanical expander (E) pushing it up to the stop.<br />

Warning: The pipe must be in axis and parallel to the extractor.<br />

4. Press the starting button (B) until the coupling is made (the pipe will be<br />

automatically released from the tool once such operation is over). The<br />

equipment is now ready for the next coupling cycle. (Wait for the shut-off valve<br />

return time, varying from 5 to 10 seconds).<br />