11.07.2015 Views

5 in 1 Recorder

5 in 1 Recorder

5 in 1 Recorder

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CATALOG 2009Vision <strong>Recorder</strong> Series, Temperature & Humidity Data Logger & Pr<strong>in</strong>terINNOVATIVE DESIGN, USER - FRIENDLY, HIGH PERFORMANCES.• Up to 4 <strong>in</strong>put channels of Temperature, Humidity & Switches• Monitor<strong>in</strong>g, Logg<strong>in</strong>g, Alarm and Pr<strong>in</strong>t<strong>in</strong>g <strong>in</strong> Real Time• Record <strong>in</strong> <strong>in</strong>tervals from 1 to 120 M<strong>in</strong>utes, <strong>in</strong> 1 M<strong>in</strong>ute <strong>in</strong>crements• Over and under alarms plus delay setup (0-120 m<strong>in</strong>.) for each channel• Operat<strong>in</strong>g and Sett<strong>in</strong>g by means of 6 function keys• Pr<strong>in</strong>t<strong>in</strong>g chooses channel <strong>in</strong> auto scale as graph, <strong>in</strong>clud<strong>in</strong>g alarms• Pr<strong>in</strong>t<strong>in</strong>g 1 or 4 Channels full report <strong>in</strong> 3 text modes, <strong>in</strong>clud<strong>in</strong>g alarms• Pr<strong>in</strong>t<strong>in</strong>g help massages, summery and sorted reports on request• Display the measur<strong>in</strong>g values, m<strong>in</strong>imum or maximum on request• Export<strong>in</strong>g real time data thru RS-232 PC port – No Software needed• Cº or Fº degrees, date format: dd/mm/yy or mm/dd/yy sett<strong>in</strong>g• Low battery, Chart end and Probe error <strong>in</strong>dicators & alarms buzzer• Remote Alarm output via relay contacts of 0.5A 115V• Remote Probes 33’ (10 meters) cable length, Extendible up to 100’• Tamper proof, unit & channels names, Real time clock, M<strong>in</strong>. /Max.• 8.2”x3”x2.7” (209x135x69 mm), 2.6 Lbs (1.8 Kg)• Data & sett<strong>in</strong>gs reta<strong>in</strong>ed after Power failureVLCELL (Optional)Cellular Data TransferEN12830Model No. Input Measur<strong>in</strong>g Options Sample capacity Included Probes 33’VLT4-12 12Vac/dc Up to 4 cannels <strong>in</strong> 16,200 po<strong>in</strong>ts 1 “VLT PROBE”Any comb<strong>in</strong>ation of of temperature (for Temperature)VLT4-115 115 VacTemperature and and Switches 1 “VLS CABLE”VLT4-230 220 Vac Switches(4 probes) (On/Off Indication)VLTH-1212Vac/dcVLTH-115 115 VacVLTH-230 220VacTemp., Humidity &Switch or 4 channelsBy 2 probes ofTemp. & Humidity16,200 po<strong>in</strong>tsTemperatureand Humidity(4 channels)1 “VLT PROBE”(for Temperature)1 “VLS CABLE”(On/Off Indication)Base Unit Operat<strong>in</strong>g Temp. range: -40°/+65°C, -40°/+150°F, With lithium batteryBase Unit Operat<strong>in</strong>g Humidity: 0 to 95% RH, non-condens<strong>in</strong>g13:50 123.4C^ -34.5Cv 123.4C^ 123.4C^13:40 123.4C^ -34.5Cv 123.4C^ 123.4C^13:30 123.4C^ -34.5Cv 123.4C^ 123.4C^13:20 123.4C^ -34.5Cv 123.4C^ 123.4C^13:10 123.4C^ -34.5Cv 123.4C^ 123.4C^13:00 123.4C^ -34.5Cv 123.4C^ 123.4C^12:50 123.4C^ -34.5Cv 123.4C^ 123.4C^12:40 123.4C^ -34.5Cv 123.4C^ 123.4C^12:30 123.4C^ -34.5Cv 123.4C^ 123.4C^12:20 123.4C^ -34.5Cv 123.4C^ 123.4C^12:10 123.4C^ -34.5Cv 123.4C^ 123.4C^12:00 123.4C^ -34.5Cv 123.4C^ 123.4C^TEMP1 FREZ2 CONT3 TANK4SUPER1234567 31/12/09 EVERY 10 MIN4 Pr<strong>in</strong>t Modes Available*Additional Probes from the table below can be added to the base unit (up to 4 channels)Probe model Measure Range Resolution Accuracy Repeatability Response Standard Accessories (optional)VLT PROBE -40° / +130°C 0,1°C ± 0,3°C ± 0,1°C 5 - 30 VLPAPER 2" Thermal chart roll 131'Temperature -40° / +266°F 0,2°F ± 0,6°F ± 0,2°F Sec. VLWCASE Water proof case + Lock-40° / +85°C 0,1°C ± 0,5°C ± 0,1°C 5 - 30 VLSK Remote alarm silencerVLTH PROBE-40° /+185°F 0,1°F ± 1,0°F ± 0,2°F Sec. CABLE33H Probe extension 33' (10m)Temperature10.0 / 89.9% RH 0,1 %RH ± 2 %RH ± 0,1 %RH 6 - 10 CABLE66H Probe extension 66' (20m)And Humidity 0.1-9.9 / 90-100% 0,1 %RH ± 4 %RH ± 0,5 %RH Sec. VPR Power reducer, 24 to 12VVLS CABLEADTA Auto phone dialerRecognized dry contacts (0/1) – for On/Off <strong>in</strong>dication 1 Sec.SwitchVLCEL Cellular adaptor to <strong>in</strong>ternetSUPCO International Ltd.PO BOX 8047, HAUMANUT ST. 3 NETANYA, 42180, ISRAEL. Tel. 972-9-865 4101 * FAX: 972-9-865 9111 <strong>in</strong>fo@supco.co.il- 14 -Small Font / Full Report Large Font / Short Report Graphic Mode (Plus Thresholds)4 Channels Text Mode

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!