CUCINOTTA / CUCINOTTA FORNO - Narvells
CUCINOTTA / CUCINOTTA FORNO - Narvells
CUCINOTTA / CUCINOTTA FORNO - Narvells
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CUCINOTTA</strong> – <strong>CUCINOTTA</strong> Forno<br />
In presence of dampness in the room where the cooker has been placed, we advise you to put absorbent<br />
salts into the hearth.<br />
If you want to keep for long the aesthetic look of the cooker it is important to protect its internal walls in row<br />
cast iron with neutral Vaseline.<br />
16. CONNECTING A CHIMNEY OR OPEN FURNACE TO THE FLUE<br />
The smoke channel is the section of tube that connects the product to the flue, in the connection these<br />
simple but very important principles must be followed:<br />
• for no reason must the smoke channel be used with a diameter lower than that of the neck of the<br />
outlet with which the product is fitted;<br />
• each metre of horizontal route of the smoke channel causes a small leak of charge which should be<br />
compensated for by raising the flue;<br />
• the horizontal section must never be higher than 2 m (UNI 10683-2005);<br />
• each bend of the smoke channel considerably reduces the draught of the flue which must be<br />
compensated for by raising it suitably;<br />
• the UNI 10683-2005 Regulation –Italy requires that the bends or variations of direction must in no<br />
case be greater than 2 including the emission into the flue.<br />
Wanting to use the flue of a chimney or open furnace, it will be necessary to close the hood hermetically<br />
below the inlet point of the smoke channel pos. A Picture 10.<br />
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary to duct it with a stainless steel tube of at<br />
least 200 mm of diameter, pos. B taking care to close the space between the tube itself and the flue<br />
immediately below the chimney cap pos. C.<br />
For any further information, please contact your Dealer!<br />
Picture 10<br />
C - Plugging<br />
A – Hermetic<br />
closure<br />
Inspection<br />
hatch<br />
26 7093101 – Rev.06 – EN<br />
B