en<br />
The goods will be taken to be compliant and suitable if:<br />
. The device under warranty is that which are working, and has been installed and operates according to applicable legislation and the<br />
manufacturer's instructions.<br />
. Start-up - this date determines the start of the warranty period - and all potential repairs are carried out by qualified personnel or Technical<br />
Support.<br />
. Official spares are used as determined by Technical Support.<br />
. The working fluid will have a pH of between 5 and 9 at 20°C, and a salt content adjusted in accordance with the following points:<br />
a) primary circuit water salinity must not exceed 500 mg/l total soluble salt. If this value is not available conductivity will be taken as limiting<br />
variable, and shall not exceed 650 _S/cm;<br />
b)calcium salt content must not exceed 200 mg/l, expressed as calcium carbonate content;<br />
c) limit for free carbon dioxide in water must not exceed 50 mg/l.<br />
The warranty expressly excludes faults produced by:<br />
a) improper product use, or not following the instructions contained in the instruction manual and other documentation provided for installation and<br />
maintenance.<br />
b) Any type of overload.<br />
c) Freezing.<br />
d) Equipment handling by non-approved personnel.<br />
e) Faults produced by force majeure (atmospheric, geological phenomena, etc.).<br />
4.<br />
SYSTEM DESCRIPTION<br />
4.1 Operation<br />
The system designed by <strong>Orkli</strong> S.Coop. incorporates the benefits of a separate solar system but with much simpler and faster installation and maintenance.<br />
In turn <strong>Orkli</strong> S.Coop. has opted for the architectural integration of the solar system.<br />
Primary recirculation pump regulation is achieved via an incorporated photovoltaic cell. This peculiarity means that the pump starts working when there<br />
is capacity to exploit solar energy. And because it is a device that varies its power depending on the amount of solar radiation, an optimum result is<br />
achieved, avoiding performance penalties<br />
CW<br />
primary drain<br />
secondary drain<br />
AF<br />
CHW<br />
CHW<br />
<strong>Orkli</strong> S.Coop. recommend installers install a thermometer at the auxiliary system inlet so that the user can observe the behaviour of the <strong>OKSOL</strong>-<strong>150</strong><br />
collector.<br />
4.2 System Limits<br />
Operating limits are set by the safety valves, which always act passively. Heat transfer fluid characteristics enable an operating range of -35 ºC - 140ºC<br />
[at 3 bar].<br />
. Max. P. solar circuit: 3 bar<br />
. Max. P. DHW circuit: 6 bar<br />
. Max. Temp DHW circuit: 95ºC<br />
We recommend keeping the tank full if the system is not used. If the tank is empty the system must be covered with a tarp or safe opaque material.<br />
. Heat Transfer Fluid min. temp.: -35ºC<br />
. Heat Transfer Fluid boiling Temp. at 3 bar: 140ºC<br />
. Stagnation temp. above ambient temp: 105ºC<br />
auxiliary system<br />
Solar radiation (W/m2)<br />
800<br />
900<br />
Ambient temp. (ºC)<br />
35<br />
25<br />
User manual - 15