The goods will be taken to be compliant and suitable if:<br />

. The device under warranty is that which are working, and has been installed and operates according to applicable legislation and the<br />

manufacturer's instructions.<br />

. Start-up - this date determines the start of the warranty period - and all potential repairs are carried out by qualified personnel or Technical<br />

Support.<br />

. Official spares are used as determined by Technical Support.<br />

. The working fluid will have a pH of between 5 and 9 at 20°C, and a salt content adjusted in accordance with the following points:<br />

a) primary circuit water salinity must not exceed 500 mg/l total soluble salt. If this value is not available conductivity will be taken as limiting<br />

variable, and shall not exceed 650 _S/cm;<br />

b)calcium salt content must not exceed 200 mg/l, expressed as calcium carbonate content;<br />

c) limit for free carbon dioxide in water must not exceed 50 mg/l.<br />

The warranty expressly excludes faults produced by:<br />

a) improper product use, or not following the instructions contained in the instruction manual and other documentation provided for installation and<br />

maintenance.<br />

b) Any type of overload.<br />

c) Freezing.<br />

d) Equipment handling by non-approved personnel.<br />

e) Faults produced by force majeure (atmospheric, geological phenomena, etc.).<br />

4.<br />

SYSTEM DESCRIPTION<br />

4.1 Operation<br />

The system designed by <strong>Orkli</strong> S.Coop. incorporates the benefits of a separate solar system but with much simpler and faster installation and maintenance.<br />

In turn <strong>Orkli</strong> S.Coop. has opted for the architectural integration of the solar system.<br />

Primary recirculation pump regulation is achieved via an incorporated photovoltaic cell. This peculiarity means that the pump starts working when there<br />

is capacity to exploit solar energy. And because it is a device that varies its power depending on the amount of solar radiation, an optimum result is<br />

achieved, avoiding performance penalties<br />

CW<br />

primary drain<br />

secondary drain<br />

AF<br />

CHW<br />

CHW<br />

<strong>Orkli</strong> S.Coop. recommend installers install a thermometer at the auxiliary system inlet so that the user can observe the behaviour of the <strong>OKSOL</strong>-<strong>150</strong><br />

collector.<br />

4.2 System Limits<br />

Operating limits are set by the safety valves, which always act passively. Heat transfer fluid characteristics enable an operating range of -35 ºC - 140ºC<br />

[at 3 bar].<br />

. Max. P. solar circuit: 3 bar<br />

. Max. P. DHW circuit: 6 bar<br />

. Max. Temp DHW circuit: 95ºC<br />

We recommend keeping the tank full if the system is not used. If the tank is empty the system must be covered with a tarp or safe opaque material.<br />

. Heat Transfer Fluid min. temp.: -35ºC<br />

. Heat Transfer Fluid boiling Temp. at 3 bar: 140ºC<br />

. Stagnation temp. above ambient temp: 105ºC<br />

auxiliary system<br />

Solar radiation (W/m2)<br />

800<br />

900<br />

Ambient temp. (ºC)<br />

35<br />

25<br />

User manual - 15