12.07.2015 Views

InPro 7200 Series Instruction manual ... - Mettler Toledo

InPro 7200 Series Instruction manual ... - Mettler Toledo

InPro 7200 Series Instruction manual ... - Mettler Toledo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>InPro</strong> <strong>7200</strong> <strong>Series</strong> 51 Introduction1.1 GeneralThe inductive Sensors <strong>InPro</strong> <strong>7200</strong> <strong>Series</strong> are intended to be usedwith Transmitter Cond Ind 7100 e, CondI 7100/2H, CondI7100/2(X)H, or M 700 (module Cond Ind 7700) to measureconductivity and concentration of liquids. Sensors are availablein a number of materials suitable for a variety of conditions.The sensors measure an induced current in a loop of solution.Two toroidally wound coils are encapsulated in close proximitywithin the sensor which is immersed in the solution. An ac signal,applied to one toroidal coil, induces a current in the secondcoil which is directly proportional to the conductance of the solution.1.2 Safety <strong>Instruction</strong>sDangersAn electrical shock hazard may be present under sensor faultconditions when sensor is located in process fluids at electricalpotentials above 30 V rms or 60 V dc. In order to prevent electricalshock hazard, remove sensor from process or de-energizepower to process prior to performing maintenance on theTransmitter Cond Ind 7100 e, CondI 7100/2H, CondI7100/2(X)H, or M 700.Certain units described in this instruction <strong>manual</strong> containelectrical shock hazard potential. Maintenance should be performedby qualified personnel only. During maintenance,remove power to avoid severe injury or death.When performing maintenance, wear appropriate, protectiveclothing including safety goggles. Escaping chemicals underpressure can cause severe injury including blindness.WarningsUse care when connecting and disconnecting high pressure serviceconnections. Use proper gloves and follow the recommendedprocedures to avoid severe injury to personnel ordamage to equipment.When processing hazardous liquids, follow the recommendedprocedures. Failure to do so could result in injury to personneland damage to equipment.Use only METTLER TOLEDO recommended replacement parts.Substitution parts could result in damage to equipment, damageto the process, and/or injury to personnel.Be careful to avoid touching exposed circuits and components.Potential shock hazards are present.© 08/04 <strong>Mettler</strong>-<strong>Toledo</strong> GmbH, CH-8606 Greifensee <strong>InPro</strong> <strong>7200</strong> <strong>Series</strong>Printed in Switzerland 52 001 408

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!