13.07.2015 Views

Motorisation pour portail coulissant LineaMatic - Hormann.fr

Motorisation pour portail coulissant LineaMatic - Hormann.fr

Motorisation pour portail coulissant LineaMatic - Hormann.fr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENGLISH5.8.4DIL switch 5/DIL switch 6ffSee Figure 7.7cSE 2 safety device (closing):ffSee Figure 7.5The functions of the safety device are set with DIL switch 5 incombination with DIL switch 6.5 ON Activation kit for closing edge safety device orphotocell with testing5 OFF • 8k2 resistance contact strip• No safety device (8k2 resistance betweenterminals 20/73, delivery status)6 ON Brief, delayed reversing in the OPEN direction (forphotocell)6 OFF Brief, immediate reversing in the OPEN direction(for SKS)8 ON 9 OFF OperatorAdvance warning phase for every gatetravel without automatic timed closingOption relayRelay clocks rapidly during theadvance warning phase, normallyduring the travel phase.ffSee Figure 7.7d8 OFF 9 OFF OperatorNo special functionOption relayRelay picks up in the CLOSE end-oftravelposition.5.8.5 DIL switch 7SE 3 protective device (closing):ffSee Figure 7.6Delayed reversing to CLOSE end-of-travel position.7 ON Dynamic 2-wire photocell7 OFF • Static photocell without testing• No safety device (wire jumper betweenterminals 20/71, delivery status)5.8.6 DIL switch 8/DIL switch 9The functions of the operator (automatic timed closing/warning phase) and the function of the option relay are setwith DIL switch 8 in combination with DIL switch 9.ffSee Figure 7.7a8 ON 9 ON OperatorAutomatic timed closing, advancewarning phase for each gate movementOption relayRelay clocks rapidly during the advancewarning phase, normally during the travelphase and is OFF during the hold-openphase.ffSee Figure 7.7b8 OFF 9 ON OperatorAutomatic timed closing, advancewarning phase only for automatic timedclosingOption relayRelay clocks rapidly during the advancewarning phase, normally during the travelphase and is OFF during the hold-openphase.Note:Automatic timed closing is only possible <strong>fr</strong>om the determinedend-of-travel positions (full or partial opening). Automatictimed closing is deactivated if it fails three times. The operatormust be restarted with an impulse.5.8.7DIL switch 10Effect of the SE 3 protective device as a through-trafficphotocell with automatic timed closingffSee Figure 7.8This switch is used to set the SE3 protective device as athrough-traffic photocell with automatic timed closing.7 ON The photocell is activated as a through-trafficphotocell, after the photocell has been passed,the hold-open phase is reduced.7 OFF The photocell is not activated as a throughtrafficphotocell. If, however, automatic timedclosing is activated and the photocellinterrupted after the hold-open phase haselapsed, the hold-open phase will be reset tothe preset time.5.8.8DIL switch 11Setting up the reversal limitsffSee Chapter Reversal limit, page 135.8.9DIL switch 12Starting point for slow speed when opening and closing:ffSee Chapter Changing the starting point for slow speedwhen opening and closing, page 1314 TR10A058-C RE / 10.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!