EN CAS DE PANNES<br />
DEFAUT CAUSE POSSIBLE REMEDES<br />
Lors de l’activation de la commande<br />
d’ouverture, la porte ne s’ouvre pas et le<br />
moteur électrique de la centrale ne démarre<br />
pas.<br />
Lors de l’activation de la commande<br />
d’ouverture, le moteur électrique de la centrale<br />
démarre mais la porte ne s’ouvre pas.<br />
Après l’opération d’ouverture, la centrale n’est<br />
plus en mesure d’effectuer celle de fermeture.<br />
Fermeture et ouverture saccadées de la porte.<br />
Fuites d’huile du réservoir de la centrale.<br />
Fuites d’huile des flasques latéraux du vérin.<br />
Mouvement intermittent du portail.<br />
Pas de freinage hydraulique en fin de course.<br />
No power supply to the electronic equipment.<br />
Fuses blown.<br />
Damaged power supply cables.<br />
Check the emergency release valve.<br />
Insufficient force to open.<br />
Gate mechanically blocked.<br />
Gate mechanically blocked.<br />
Insufficient force to close.<br />
Check that the control unit motor is functioning.<br />
Check that the gate is perfectly perpendicular.<br />
Air inside the jacks.<br />
Check the seal of the corner piece weldings holding the<br />
base plate.<br />
Bleeder screw closed.<br />
Oil leaking from the bleeder screw hole.<br />
Forcing of the gate due to burglars or due to jerky functioning.<br />
The gate is not perfectly perpendicular.<br />
Air in the hydraulic system.<br />
Wind and/or a solid gate.<br />
Excessive clearance between the jack base plate and the<br />
corner pieces.<br />
Insufficient brake adjustment.<br />
Incorrect timing adjustment.<br />
Air in the hydraulic system.<br />
Gate opening angle is less than jack working area.<br />
Restore the power supply<br />
Replace the fuses with others of the<br />
same amperage.<br />
Replace the cable and eliminate<br />
the cause of its damage.<br />
Screw down the valve tightly in a<br />
clockwise direction.<br />
Adjust the Silver valve as in fig. D4.<br />
Do not screw down completely.<br />
Eliminate any friction or mechanical<br />
problems.<br />
Eliminate the mechanical problems.<br />
Adjust the Gold valve as in fig. D4.<br />
Do not screw down completely.<br />
Check the electronic apparatus:<br />
safety devices incorrectly connected.<br />
Make the gate perfectly perpendicular.<br />
Bleed the air as in fig. C20.<br />
Reinforce the welds and, in the event<br />
of excessive play, fit spacers between<br />
the corner pieces and the plate.<br />
Remove the bleed screw as in fig. C22.<br />
Remove the surplus oil from the<br />
control unit.<br />
Dismantle the jack and send it to an<br />
Aprimatic service centre for repair.<br />
Plumb the gate.<br />
Bleed the system and check the connections<br />
and the piping to detect any possible air inlets.<br />
Check the valve calibration; if the problem<br />
persists, use an <strong>ZT</strong> 70 FS control unit.<br />
Remove the corner pieces and re-weld them,<br />
eliminating the clearance. (pag. 16 C6)<br />
Adjust the braking by means of the<br />
appropriate needles (pag. 25 D6).<br />
Restore correct jack timing (pag.<br />
17-18).<br />
Bleed the system and check the<br />
connections and the piping to detect<br />
any possible air inlets.<br />
Re-adjust the jack timing to obtain<br />
one-way braking only.<br />
E<br />
27