Thermocooker – <strong>TERMOSUPREMA</strong> <strong>Compact</strong> <strong>DSA</strong><br />
Definition: thermocooker in accordance with EN 12815<br />
1. TECHNICAL DATA<br />
<strong>TERMOSUPREMA</strong> COMPACT<br />
<strong>DSA</strong><br />
Overall thermal power in kW 22.3<br />
Useful thermal power in kW 18.5<br />
Output power to liquid (H 2 O) in kW 15<br />
Output power to room in kW 3.5<br />
Hourly wood consumption in kg / h (wood with 20% humidity) 5.2<br />
Yield 83<br />
CO measured at 13% oxygen in % 0.12<br />
Flue gas exhaust pipe diameter in mm<br />
Flue diameter in mm<br />
160 S/P<br />
5m – 220x220 Ø220 ∗<br />
Water contained in the boiler in litres 22<br />
Chimney pressure in Pa (mm H 2 O) 1.7<br />
Delivery and return connector diameter (nominal bore)<br />
External air intake section Ø in mm 200<br />
1¼”F<br />
Exhaust gas emission in g/s – wood 26.84<br />
Exhaust gas temperature in °C - wood 186<br />
Optimum working temperature in °C 70-75<br />
Max. operating pressure in bar<br />
VA1,5 - VEC3<br />
Furnace opening dimensions mm (L x H) 233 x 193<br />
Furnace body / furnace headpiece dimensions in mm (L x H x D) 257 x 395 x 407<br />
Oven dimensions in mm (L x H x D) 307 x 418 x 430<br />
Type of grill<br />
Movable - flat<br />
Thermocooker height in mm 881<br />
Thermocooker width in mm 982<br />
Thermocooker depth (with handles) in mm 682<br />
Weight in Kg 280<br />
Fire prevention safety distances Chapter 4<br />
∗ 200 mm diameter can be used with flue of no less than 6 m<br />
The heating volume of the cookers in accordance with EN 12815, for buildings whose thermal insulation does not<br />
correspond to the provisions regarding heat protection, is:<br />
(30 Kcal/h x m 3 ) - favourable type of building: 530 m³<br />
(40 Kcal/h x m 3 ) -less favourable type of building: 400 m³<br />
(50 Kcal/h x m 3 ) - unfavourable type of building: 320 m³<br />
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater.<br />
With temporary heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by<br />
about 25%.<br />
IMPORTANT: The power of the connected heating system must be proportional to the power transferred to<br />
the water by the thermocooker; a charge which is too low does not allow regular oven<br />
operation, while a charge which is too high prevents adequate radiator heating.<br />
Instructions for installation, use and maintenance – EN – Rev.00 21