Thermocooker – <strong>TERMOSUPREMA</strong> <strong>Compact</strong> <strong>DSA</strong><br />

Definition: thermocooker in accordance with EN 12815<br />

1. TECHNICAL DATA<br />

<strong>TERMOSUPREMA</strong> COMPACT<br />

<strong>DSA</strong><br />

Overall thermal power in kW 22.3<br />

Useful thermal power in kW 18.5<br />

Output power to liquid (H 2 O) in kW 15<br />

Output power to room in kW 3.5<br />

Hourly wood consumption in kg / h (wood with 20% humidity) 5.2<br />

Yield 83<br />

CO measured at 13% oxygen in % 0.12<br />

Flue gas exhaust pipe diameter in mm<br />

Flue diameter in mm<br />

160 S/P<br />

5m – 220x220 Ø220 ∗<br />

Water contained in the boiler in litres 22<br />

Chimney pressure in Pa (mm H 2 O) 1.7<br />

Delivery and return connector diameter (nominal bore)<br />

External air intake section Ø in mm 200<br />

1¼”F<br />

Exhaust gas emission in g/s – wood 26.84<br />

Exhaust gas temperature in °C - wood 186<br />

Optimum working temperature in °C 70-75<br />

Max. operating pressure in bar<br />

VA1,5 - VEC3<br />

Furnace opening dimensions mm (L x H) 233 x 193<br />

Furnace body / furnace headpiece dimensions in mm (L x H x D) 257 x 395 x 407<br />

Oven dimensions in mm (L x H x D) 307 x 418 x 430<br />

Type of grill<br />

Movable - flat<br />

Thermocooker height in mm 881<br />

Thermocooker width in mm 982<br />

Thermocooker depth (with handles) in mm 682<br />

Weight in Kg 280<br />

Fire prevention safety distances Chapter 4<br />

∗ 200 mm diameter can be used with flue of no less than 6 m<br />

The heating volume of the cookers in accordance with EN 12815, for buildings whose thermal insulation does not<br />

correspond to the provisions regarding heat protection, is:<br />

(30 Kcal/h x m 3 ) - favourable type of building: 530 m³<br />

(40 Kcal/h x m 3 ) -less favourable type of building: 400 m³<br />

(50 Kcal/h x m 3 ) - unfavourable type of building: 320 m³<br />

With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater.<br />

With temporary heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by<br />

about 25%.<br />

IMPORTANT: The power of the connected heating system must be proportional to the power transferred to<br />

the water by the thermocooker; a charge which is too low does not allow regular oven<br />

operation, while a charge which is too high prevents adequate radiator heating.<br />

Instructions for installation, use and maintenance – EN – Rev.00 21