12.07.2015 Views

SNAP Gentamicin Insérer - Idexx

SNAP Gentamicin Insérer - Idexx

SNAP Gentamicin Insérer - Idexx

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

snap ® 06-04231-01Step 3 cont.Visual Interpretationc. Read results immediately.d. Follow "Interpreting Test Results" as indicated below.<strong>Gentamicin</strong> Test KitInterpreting Test ResultsWhen interpreting results, position the <strong>SNAP</strong> device with the sample well to the left, as seen in the diagram. If colordevelopment does not occur in the control spot, retest sample.Sample Well Control Spot Activation CircleNegative ResultSample Spot is darker than orequal to the Control SpotProduct and Intended UseThe <strong>SNAP</strong> ® <strong>Gentamicin</strong> Test kit is an enzyme-linked immunoassay designed to detect gentamicin residues in raw commingledbovine milk. The <strong>SNAP</strong> <strong>Gentamicin</strong> Test is recommended for use by Quality Assurance personnel who have received training byan IDEXX Representative.Sample SpotActivatorPositive ResultSample Spot is lighter thanControl SpotIntroductionFailure to follow antibiotic label instructions and milk withholding guidelines may result in antibiotic residues in milk. The <strong>SNAP</strong><strong>Gentamicin</strong> Test kit is designed to provide convenience and ease-of-use in monitoring gentamicin residues as part of a qualityassurance program.Performance InformationSensitivityThe <strong>SNAP</strong> <strong>Gentamicin</strong> Test Kit is designed to detect gentamicin residues in rawcommingled bovine milk at or below 30 ppb.Sole reliance on use of this kit may result in the rejection of milk that is considered safe for humanconsumption.Kit ComponentsCapSampleTubeOrange Reagent PelletSnapDeviceComponents Required But Not Included(Available through IDEXX Laboratories, Inc.)• Heat Block Heater capable of maintaining an operating temperature of 45°C (113°F) ± 5°C.• <strong>SNAP</strong> ® Block Insert®PipetFor technical assistance, call IDEXX Technical Service 800-321-0207.IDEXX Laboratories, Inc. One IDEXX Drive, Westbrook, Maine 04092 USA Tel.: 207-856-0300 or 800-321-0207 Fax: 207-856-0630Covered by U.S. Patent Nos. 5,627,026; 5,726,010; 5,726,013; 5,750,333 and/or 6,007,999. Other U.S. and/or foreign patents issued or pending.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!