This project encompasses a redevelopment plan for one of the vacant office buildings in Heerlen. It is the graduation project of the Bachelor Built Environment at Zuyd University of applied science (Dutch). The goal was to redevelop the building from an office into apartments and studios focused specifically on young one person households, while also adding quality green space to Heerlens city center.

This project encompasses a redevelopment plan for one of the vacant office buildings in Heerlen. It is the graduation project of the Bachelor Built Environment at Zuyd University of applied science (Dutch). The goal was to redevelop the building from an office into apartments and studios focused specifically on young one person households, while also adding quality green space to Heerlens city center.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5.2 – Energie

Een van de eisen aan het projectgebouw is dat het

energieneutraal wordt uitgevoerd. Dit houd in dat er

minstens even veel energie wordt opgewekt als er gebruikt

wordt in het pand. Om het pand energieneutraal te maken

zijn energieberekeningen uitgevoerd. De uitwerking van deze

berekeningen vind u verderop in deze paragraaf. Daarnaast

is een EPC berekening uitgevoerd aan de hand van Uniec.

De resultaten van de EPC berekening zijn opgenomen in

bijlage 4. De EPC berekening gaat enkel over bouwdeel A.

5.2.1 – Berekening zonenergie

Een klein huishouden verbruikt gemiddeld 1930 kWh/jaar.

Deze waarde gaat echter uit van een huishouden waarin de

ruimteverwarming en warm tapwater bereiding met gas

voldaan worden. Omdat het gebouw beter geïsoleerd is dan

de gemiddelde woning (ie bijlage 3 voor een berekening)

wordt er minder energie gebruikt en kan worden

aangenomen dat de nodige energie voor ruimteverwarming

en warm tapwater bereiding gecompenseerd wordt door de

besparing. (Milieu Centraal, 2018) Voor kantoren wordt

gerekend met een energieverbruik van 109 kWh/m 2 en voor

horeca wordt gerekend met een energieverbruik van 120

kWh/m 2 . deze cijfers komen voort uit een rapport van

SenterNovum. (SenterNovum, 2007)

Voor de opwekking van energie wordt uitgegaan van een

gemiddelde opbrengst van 100 kWh/m 2 voor de

zonnepanelen die op het dak liggen. (Energieleveranciers,

2018) Voor de ZigZagSolar wand wordt uitgegaan van een

optimale opbrengst van 135 kWh/m 2 geveloppervlakte

conform informatie van de leverancier. (Wall, 2018)

Energieverbruik:

Woningen: 1930 kWh/jaar * 19 = 36.670 kWh/jaar

Kantoren: 109 kWh * 285 m 2 = 31.065 kWh/jaar

Horeca: 120 kWh * 112 m 2 = 13.440 kWh/jaar

----------------------- +

81.175 kWh/jaar

De woningen gebruiken 45,17% van alle energie. Enkel de

woningen in bouwdeel A (15 woningen) gebruiken 35.66%

van alle energie. In de EPC berekening is dan ook slechts

35,66% van de energieleverende toepassingen meegenomen.

Energieopwekking:

Dakoppervlak zonnepanelen:

Dak A: 12,8*23,1= 295,7 m 2

Dak C: 11,2*31,7= 355,1 m 2

---------------- +

650,8 m 2

650,8 m 2 * 100 kWh/m 2 = 65.080 kWh/jaar

ZigZagSolar wand:

11,45 * 11,22 = 128,5 m 2

128,5 m 2 * 135 kWh/m 2 = 17.347 kWh/jaar

Totaal:

66.560 + 12.850 = 82.427 kWh/jaar

Ten behoeve van de EPC berekening voor bouwdeel A wordt

uitgegaan van 35.66 % van de energieopwekking. Dit om de

berekening in verhouding kloppend te maken. Toepassing

van dit percentage resulteert in de volgende cijfers:

Totaal dakoppervlak:

650,8 m 2 * 35,66% = 232,08 m 2

128,5 m 2 * 35,66% = 45,82 m 2

5.2.2 – Daglicht & zontoetreding

De woningen hebben allemaal een klein raam in de

badkamer en ten minste drie ramen in het woongedeelte. In

bijlage 2 is een daglichttoetreding te vinden met betrekking

op woningtype 1C. Verder is meer informatie over de

berekening te vinden in hoofdstuk 7.2. De ramen zijn

voorzien van geïntegreerde zonneschermen aan de

buitenkant die dient als zonwering.

5.2.3 – Verwarming & koeling

Voor ruimteverwarming en koeling wordt gebruik gemaakt

van een all-electric systeem. De ruimte verwarming en

koeling vind plaats met behulp van een warmtepomp die

wordt aangesloten op het lokale mijnwatersysteem. Door

gebruik te maken van een elektrische warmtepomp in plaats

van een elektrische cv ketel kan een rendement van 400%

gehaald worden. Door de warmtepomp ook te gebruiken

voor koeling wordt de warmtebron geregenereerd waardoor

deze in de winter weer warm genoeg is om de woning in

warmte te voorzien.

5.2.4 – Ventilatie

De woningen in bouwdeel A en C worden geventileerd door

middel van een natuurlijke luchttoevoer via de in de woning

gelegen gevelopeningen. De toegevoerde lucht wordt door

een mechanische afvoer in de keuken en badkamer de

woning uitgevoerd. Dit zelfde principe geld voor de horeca

gelegenheid in bouwdeel C. De ventilatielucht in bouwdeel B

wordt aangevoerd via roosters in de vloer. De koele lucht

warmt op en stijgt naar het plafond, waar de lucht via een

mechanische afzuiging weggevoerd wordt via het dak.

5.2.5 – Verlichting en armatuur

De energievraag voor verlichting en armatuur is gebaseerd

op kengetallen uit de EPC berekening (bijlage 4). Hieruit

blijkt dat 46863 MJ nodig is om bouwdeel A van energie te

voorzien. Deze waarde is forfaitair bepaald en kan daarom

in praktijk lager uitpakken. In de gezamenlijke delen van

het gebouw word LED verlichting toegepast. Daarnaast is er

zoveel mogelijk gekozen voor low-tech ingrepen zoals

natuurlijke ventilatie.

31