12.07.2015 Views

Nov-Dez - Sociedade Brasileira de Oftalmologia

Nov-Dez - Sociedade Brasileira de Oftalmologia

Nov-Dez - Sociedade Brasileira de Oftalmologia

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Carcinoma basocelular após tratamento cirúrgico e imunoterapia tópicavol. 68 - nº 6 - <strong>Nov</strong>embro / <strong>Dez</strong>embro 2009


Revista<strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong>321ISSN 0034-7280PUBLICAÇÃO OFICIAL:SOCIEDADE BRASILEIRA DE OFTALMOLOGIASOCIEDADE BRASILEIRA DE CATARATA E IMPLANTES INTRAOCULARESSOCIEDADE BRASILEIRA DE CIRURGIA REFRATIVAWEB OF SCIENCEIn<strong>de</strong>xada nas bases <strong>de</strong> dados:SciELOScientific ElectronicLibrary OnLineLILACSLiteratura Latino-americanaem Ciências da Saú<strong>de</strong>www.sboportal.org.brEditor ChefeRaul Nunes Galvarro Vianna - Niterói - RJCo-editoresAcácio Muralha Neto - Niterói - RJAna Luisa Hofling <strong>de</strong> Lima - São Paulo - SPHelena Parente Solari - Niterói - RJJaco Lavinsky - Porto Alegre - RSJosé Beniz Neto - Goiania - GOMarcelo Luis Occhiutto - São Paulo - SPMarcio Bittar Nehemy - Belo Horizonte - MGMarcos Pereira <strong>de</strong> Ávila - Goiania - GOPaulo Fa<strong>de</strong>l - Curitiba - PRRoberto Lorens Marback - Salvador - BASergio Kwitko - Porto Alegre - RSCorpo Editorial InternacionalBaruch D. Kuppermann - Califórnia -EUAChristopher Rapuano - Phyla<strong>de</strong>lphia -EUADeepin<strong>de</strong>r Kauer Dhaliwal - Pittsburg - EUAFelipe A. A. Me<strong>de</strong>iros - Califórnia - EUAHoward Fine - Eugene - EUAJean Jacques De Laey - Ghent -BélgicaLawrence P. Chong - Califórnia -EUAMiguel Burnier Jr. - Montreal-CanadáPeter Laibson - Phyla<strong>de</strong>lphia -EUASteve Arshinoff - Toronto -CanadáDaniel Grigera - Olivos - ArgentinaCurt Hartleben Martkin - Colina Roma -MéxicoFelix Gil Carrasco - México - MéxicoCorpo Editorial NacionalAbelardo <strong>de</strong> Souza Couto Jr.- Rio <strong>de</strong> Janeiro- RJAdalmir Mortera Dantas- Niteroi- RJAntonio Augusto Velasco E Cruz- Ribeirao Preto- SPAri <strong>de</strong> Souza Pena- Niteroi- RJArlindo Jose Freire Portes - Rio <strong>de</strong> Janeiro - RJArmando Stefano Crema- Rio <strong>de</strong> Janeiro- RJCarlos Alexandre <strong>de</strong> Amorim Garcia- Natal- RNCarlos Augusto Moreira Jr.- Curitiba- PRCarlos Ramos <strong>de</strong> Souza Dias- Sao Paulo- SPCelso Marra Pereira- Rio <strong>de</strong> Janeiro- RJClaudio do Carmo Chaves - Manaus - AMDenise <strong>de</strong> Freitas- Sao Paulo- SPEdmundo Frota De Almeida Sobrinho- Belem- PAEduardo Cunha <strong>de</strong> Souza- Sao Paulo- SPEduardo Ferrari Marback- Salvador- BAFernando Cançado Trinda<strong>de</strong>- Belo Horizonte- MGFernando Oréfice- Belo Horizonte- MGFlavio Rezen<strong>de</strong>- Rio <strong>de</strong> Janeiro- RJFrancisco <strong>de</strong> Assis Cor<strong>de</strong>iro Barbosa- Recife- PEDisponível eletronicamente:Francisco Grupenmacher- Curitiba- PRFrancisco Valter da Justa Freitas- Fortaleza- CEGiovanni N.U.I.Colombini- Rio <strong>de</strong> Janeiro- RJGuilherme Herzog Neto- Rio <strong>de</strong> Janeiro- RJHaroldo Vieira <strong>de</strong> Moraes Jr.- Rio <strong>de</strong> Janeiro- RJHen<strong>de</strong>rson Celestino <strong>de</strong> Almeida- Belo Horizonte- MGHilton Arcover<strong>de</strong> G. <strong>de</strong> Me<strong>de</strong>iros- Brasilia- DFHomero Gusmao <strong>de</strong> Almeida- Belo Horizonte- MGItalo Mundialino Marcon- Porto Alegre- RSJoão Borges Fortes Filho- Porto Alegre- RSJoão Luiz Lobo Ferreira- Florianopolis- SCJoão Orlando Ribeiro Goncalves- Teresina- PIJoaquim Marinho <strong>de</strong> Queiroz- Belem- PAJose Ricardo Carvalho L. Reh<strong>de</strong>r- Sao Paulo- SPLaurentino Biccas Neto- Vitoria- ESLeiria <strong>de</strong> Andra<strong>de</strong> Neto- Fortaleza- CELiana Maria V. <strong>de</strong> O. Ventura- Recife- PELuiz Claudio Santos <strong>de</strong> Souza Lima - Rio <strong>de</strong> Janeiro - RJManuel Augusto Pereira Vilela- Porto Alegre- RSMarcelo Palis Ventura- Niteroi- RJMarco Antonio Rey <strong>de</strong> Faria- Natal- RNMaria <strong>de</strong> Lour<strong>de</strong>s Veronese Rodrigues- Ribeirao Preto- SPMaria Rosa Bet <strong>de</strong> Moraes Silva- Botucatu- SPMario Luiz Ribeiro Monteiro - São Paulo- SPMaurício Bastos Pereira - RJMario Martins dos Santos Motta- Rio <strong>de</strong> Janeiro- RJMiguel Angelo Padilha Velasco- Rio <strong>de</strong> Janeiro- RJMiguel Hage Amaro - Belém - PAMilton Ruiz Alves- Sao Paulo- SPNassim da Silveira Calixto- Belo Horizonte- MGNewton Kara Jose - Sao Paulo - SPNewton Kara José Jr. - São Paulo - SPOctávio Moura Brasil do Amaral Fo.- Rio <strong>de</strong> Janeiro- RJOswaldo Moura Brasil- Rio <strong>de</strong> Janeiro- RJPaulo Augusto De Arruda Mello- Sao Paulo- SPPaulo Schor- Sao Paulo- SPRemo Susanna Jr.- Sao Paulo- SPRenato Ambrosio Jr.- Rio <strong>de</strong> Janeiro- RJRenato Luiz Nahoum Curi- Niteroi- RJRiuitiro Yamane - Niterói - RJRogerio Alves Costa- Araraquara- SPRubens Camargo Siqueira- S.J do Rio Preto- SPSebastiao Cronemberger So.- Belo Horizonte- MGSergio Henrique S. Meirelles- Rio <strong>de</strong> Janeiro- RJSilvana Artioli Schellini - Botucatu- SPSuel Abujamra- Sao Paulo- SPTa<strong>de</strong>u Cvintal- Sao Paulo- SPValenio Peres Franca- <strong>Nov</strong>a Lima- MGVirgilio Augusto M. Centurion- Sao Paulo- SPWalton Nose- Sao Paulo- SPWesley Ribeiro Campos- Passos- MGYoshifumi Yamane- Rio <strong>de</strong> Janeiro- RJCoor<strong>de</strong>nação<strong>de</strong> Aperfeiçoamento<strong>de</strong> Pessoal<strong>de</strong> Nível Superiorhttp://www.capes.gov.brPublicação bimestral Rev Bras Oftalmol, v. 68, n. 6, p. 321-374, <strong>Nov</strong>./<strong>Dez</strong>. 2009Redação:Rua São Salvador, 107LaranjeirasCEP 22231-170Rio <strong>de</strong> Janeiro - RJTel: (0xx21) 3235-9220Fax: (0xx21) 2205-2240Tiragem:5.000 exemplaresEdição:BimestralSecretaria:Marcelo DinizEditoração Eletrônica:<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong>Responsável:Marco Antonio PintoDG 25341RJPublicida<strong>de</strong>:<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong>Responsável: João Dinizjoaodiniz@sboportal.org.brContato publicitário:Westinghouse CarvalhoTels.: (11)3726-6941 /9274-0724westin@terra.com.brRevisão:Eliana <strong>de</strong> SouzaFENAJ-RP 15638/71/05Normalização:Edna Terezinha RotherAssinatura Anual:R$240,00 ou US$210,00


322Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>Rua São Salvador, 107 - Laranjeiras - CEP 22231-170 - Rio <strong>de</strong> Janeiro - RJTels: (0xx21) 3235-9220 - Fax: (0xx21) 2205-2240 - e-mail: sbo@sboportal.org.br - www.sboportal.org.brRevista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>, ISSN 0034-7280, é uma publicação bimestral da <strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>Diretoria da SBO 2009-2010Presi<strong>de</strong>nteMário MottaVice-presi<strong>de</strong>nte RJA<strong>de</strong>rbal <strong>de</strong> Albuquerque Alves Jr.Vice-presi<strong>de</strong>ntes regionaisFernando Trinda<strong>de</strong>João Borges Fortes FilhoMiguel Hage AmaroRoberto MarbackSecretário GeralArmando Crema1º SecretárioAlmir Ghiaroni2º SecretárioLília MuralhaTesoureiroSansão KacDiretor <strong>de</strong> CursosArlindo PortesDiretor <strong>de</strong> PublicaçõesRaul ViannaDiretor <strong>de</strong> BibliotecaRicardo Lima <strong>de</strong> Almeida NevesConselho ConsultivoA<strong>de</strong>rbal <strong>de</strong> Albuquerque AlvesCelso Marra PereiraMorizot Leite FilhoLuiz Carlos PortesMiguel Ângelo PadilhaOswaldo Moura BrasilConselho FiscalEfetivosPaiva Gonçalves NetoGilberto dos PassosGiovanni ColombiniSuplentesMário NagaoOctávio Moura BrasilRoberli Bichara PintoSOCIEDADES FILIADAS A SOCIEDADE BRASILEIRA DE OFTALMOLOGIAAssociação <strong>Brasileira</strong> <strong>de</strong> Banco <strong>de</strong> Olhos e Transplante <strong>de</strong> CórneaPresi<strong>de</strong>nte: Dr. Ari <strong>de</strong> Souza PenaAssociação Matogrossense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Fabiano Saulo Rocha Jr.Associação Pan-Americana <strong>de</strong> Banco <strong>de</strong> OlhosPresi<strong>de</strong>nte: Dr. Elcio Hi<strong>de</strong>o SatoAssociação Paranaense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Ezequiel PortellaAssociação Sul Matogrossense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Beogival Wagner Lucas SantosAssociação Sul-Mineira <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Elias Donato<strong>Socieda<strong>de</strong></strong> Alagoana <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Jack Arnold Oliveira Lima<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> Administração em <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Renato Ambrósio Jr.<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> Catarata e Implantes IntraocularesPresi<strong>de</strong>nte: Dr. Marco Rey Faria<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> Cirurgia Plástica OcularPresi<strong>de</strong>nte: Dra. Suzana Matayoshi<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> Cirurgia RefrativaPresi<strong>de</strong>nte: Dr. José Ricardo Lima Reh<strong>de</strong>r<strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> Ecografia em <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Celso Klejnberg<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> do AmazonasPresi<strong>de</strong>nte: Dr. Manuel Neuzimar Pinheiro Junior<strong>Socieda<strong>de</strong></strong> Capixaba <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. César Fracalossi Barbieri<strong>Socieda<strong>de</strong></strong> Catarinense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Walbert <strong>de</strong> Paula e Souza<strong>Socieda<strong>de</strong></strong> Goiana <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Solimar Moisés <strong>de</strong> Souza<strong>Socieda<strong>de</strong></strong> Maranhense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Mauro César Viana <strong>de</strong> Oliveira<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> da BahiaPresi<strong>de</strong>nte: Dra. Cláudia Galvão Brochado<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> do CearáPresi<strong>de</strong>nte: Dr. David da Rocha Lucena<strong>Socieda<strong>de</strong></strong> Norte Nor<strong>de</strong>ste <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Raimundo Emanuel Menezes Maciel<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> do Nor<strong>de</strong>ste MineiroPresi<strong>de</strong>nte: Dr. Mauro César Gobira Guimarães<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> <strong>de</strong> PernambucoPresi<strong>de</strong>nte: Dr. Paulo Josse Suassuna <strong>de</strong> Me<strong>de</strong>iros<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> do Rio Gran<strong>de</strong> do NortePresi<strong>de</strong>nte: Dr. Uchoandro Bezerra Costa Uchôa<strong>Socieda<strong>de</strong></strong> <strong>de</strong> <strong>Oftalmologia</strong> do Rio Gran<strong>de</strong> do SulPresi<strong>de</strong>nte: Dr. Afonso Reichel Pereira<strong>Socieda<strong>de</strong></strong> Paraibana <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Ivan<strong>de</strong>mberg Velloso Meira Lima<strong>Socieda<strong>de</strong></strong> Paraense <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Ofir Dias Vieira<strong>Socieda<strong>de</strong></strong> Sergipana <strong>de</strong> <strong>Oftalmologia</strong>Presi<strong>de</strong>nte: Dr. Joel Carvalhal Borges


Revista<strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong>323ISSN 0034-7280PUBLICAÇÃO OFICIAL:SOCIEDADE BRASILEIRA DE OFTALMOLOGIASOCIEDADE BRASILEIRA DE CATARATA E IMPLANTES INTRAOCULARESSOCIEDADE BRASILEIRA DE CIRURGIA REFRATIVAFundada em 01 <strong>de</strong> junho <strong>de</strong> 1942CODEN: RBOFA9In<strong>de</strong>xada nas bases <strong>de</strong> dados:WEB OF SCIENCESciELOScientific ElectronicLibrary OnLineLILACSLiteratura Latino-americanaem Ciências da Saú<strong>de</strong>www.sboportal.org.brDisponível eletronicamente:Coor<strong>de</strong>nação<strong>de</strong> Aperfeiçoamento<strong>de</strong> Pessoal<strong>de</strong> Nível Superiorhttp://www.capes.gov.brPublicação bimestral Rev Bras Oftalmol, v. 68, n. 6, p. 321-374, <strong>Nov</strong>./<strong>Dez</strong>. 2009Editorial325 Como (ainda) ser feliz na profissãoFrancisco Valter da Justa FreitasArtigos originaisSumário - Contents327 Percepção da administração tópica ocular <strong>de</strong> drogas: vaporização x gotasThe drug administration perception: spray x eyedropArlindo José Freire Portes, Louise Pellegrino Gomes, Beatriz Lopes Moura Brasil do Amaral, Lívio Massa332 Avaliação da microbiota ocular em paciente com disfunção do filme lacrimalEvaluation of conunctival flora in patients with tear film dysfunctionMelissa Megume Tomimatsu, Manuela Maria Valença Cor<strong>de</strong>iro Barbosa, Cecília Zorat Yu, FlavioEduardo Hirai, Ana Luisa Höfling-Lima338 Estudo do comportamento da PIO <strong>de</strong> 24 horas e frequência <strong>de</strong> glaucoma empacientes com síndrome da apnéia obstrutiva do sonoStudy on 24 hours IOP study and glaucoma frequency in patients with obstructivesleep apnea syndromeMaria Rosa Bet <strong>de</strong> Moraes Silva, Silke Anna Theresa Weber


324Relato <strong>de</strong> Caso344 Síndrome do bloqueio capsular precoce relato <strong>de</strong> caso e especulação sobre otamanho da parte óptica da lente como fator <strong>de</strong> riscoEarly caspsular block syndrome a case report and speculation about the size of thelens’ optic as a risk factorEduardo Ferrari Marback, Rita <strong>de</strong> Cássia Aquino <strong>de</strong> Araújo, Marcelo Siqueira <strong>de</strong> Freitas348 Hipertensão ocular “mascarada” por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarataOcular hipertension confoun<strong>de</strong>d by corneal e<strong>de</strong>ma after cataract surgeryBruno <strong>de</strong> Freitas Valbon, Fre<strong>de</strong>rico Guerra, Renata Siqueira da Silva, Ana Laura Canedo,Renato Ambrósio Junior355 Imunoterapia tópica no tratamento do carcinoma basocelular periocularTopical immunotherapy for the treatment of periocular basal cell carcinomaErick Marcet Santiago <strong>de</strong> Macedo, Rachel Camargo Carneiro, Suzana Matayoshi,Artigo <strong>de</strong> Revisão359 “Crosslinking”<strong>de</strong> colágeno no tratamento do ceratoconeCollagen crosslinking for the treatment of keratoconousRodrigo Coelho Amaral, Helena Parente SolariÍndice Remissivo365 Índice Remissivo do volume 68Instruções aos autores372 Normas para publicação <strong>de</strong> artigos na RBO


EDITORIAL325Como (ainda) ser feliz na profissãoApós quatro décadas <strong>de</strong> tranquilo exercício da oftalmologia julgo-me autorizado a tentarcompartilhar algumas idéias <strong>de</strong> como ainda é possível ser feliz como médico. A mensagem<strong>de</strong>stina-se principalmente aos mais jovens.Vivemos tempos <strong>de</strong> materialismo exaltado e <strong>de</strong> aparências. Para Gilles Lipovetsky, filósofofrancês contemporâneo, no pós-mo<strong>de</strong>rnismo a “imagem” domina a realida<strong>de</strong>. Ser alguém é aparecerna tela e no website. Aquilo que é visto <strong>de</strong>fine o que <strong>de</strong>ve ser; quase ninguém mais se importa com oque é realida<strong>de</strong>. A imagem pública é o objeto <strong>de</strong> culto.Múltiplas instituições vivem atualmente uma crise <strong>de</strong> credibilida<strong>de</strong>. As pessoas <strong>de</strong>ixam <strong>de</strong>crer em sua serieda<strong>de</strong>. Isso se reflete na economia, na política e também, é óbvio, na vida diária <strong>de</strong>cada um. A Medicina não ficou imune à <strong>de</strong>scrença. Tanto as crises econômica e política quanto amédica po<strong>de</strong>m ser atribuídas a uma outra muito maior e pouco comentada – a crise ética.Não é objetivo <strong>de</strong>ste trabalho discutir o que é ética, já que po<strong>de</strong>mos simplificar o conceito comuma frase milenar: “Não faças aos outros aquilo que não queres que te façam”. O egocentrismo, oindividualismo e a indiferença por conceitos fundamentais para a boa convivência, aliados à exacerbaçãodo <strong>de</strong>sejo <strong>de</strong> ter, consumir e ostentar, têm gerado monstros insensíveis e vorazes.Gran<strong>de</strong>s corporações estudam como programar a obsolescência <strong>de</strong> seus produtos, geram expectativas<strong>de</strong>smedidas e irreais quanto à eficácia <strong>de</strong> seus lançamentos (muitas vezes meras reedições <strong>de</strong>fracassos passados) e cooptam profissionais bem conhecidos para ajudar a validá-los e vendê-los.A ânsia pela fama, pelo conforto e por contas bancárias muito acima do razoável ajudam a vercom naturalida<strong>de</strong> tais <strong>de</strong>sfigurações da ativida<strong>de</strong> médica. O respeito pelo semelhante é posto <strong>de</strong>lado, importando o paciente apenas como objeto <strong>de</strong> ganho, lícito ou não.Títulos <strong>de</strong> pós-graduação e <strong>de</strong> docência, assim como posições <strong>de</strong> <strong>de</strong>staque na classe e nacomunida<strong>de</strong>, são buscados a todo custo por alguns para uso como púlpitos <strong>de</strong> on<strong>de</strong> possam bradarsua sapiência “indiscutível” ou escudos contra sanções <strong>de</strong> qualquer or<strong>de</strong>m.Qual a finalida<strong>de</strong> disso tudo? Será que tal conduta gera felicida<strong>de</strong> genuína? Sabemos que não.Quase sempre (o tempo tem mostrado <strong>de</strong> maneira eloquente) o resultado é uma chusma <strong>de</strong> doenças,<strong>de</strong>sastres (pessoais ou familiares), <strong>de</strong>sgraças <strong>de</strong> toda or<strong>de</strong>m e <strong>de</strong>silusão. Não é o mero acúmulo <strong>de</strong>bens materiais e/ou <strong>de</strong> honrarias que produz felicida<strong>de</strong>.Buscar a paz <strong>de</strong> espírito, a saú<strong>de</strong> do corpo eo equilíbrio familiar são receitas milenares, mais simples e tremendamente eficazes. Isso significaexercer a profissão com amor ao semelhante, solidarieda<strong>de</strong> com os companheiros, mo<strong>de</strong>ração nacompetição e a certeza <strong>de</strong> que (como dizia Ortega y Gasset) “o homem é apenas meta<strong>de</strong> <strong>de</strong> simesmo; a outra é sua circunstância”. Portanto, não há porquê <strong>de</strong>sesperar-se por não pertencer aoclube dos famosos, não ostentar o título <strong>de</strong> professor <strong>de</strong> alguma Universida<strong>de</strong> importante, não ser aestrela dos congressos. Nem todos são bafejados com circunstâncias favoráveis à notorieda<strong>de</strong>.Não se trata <strong>de</strong> fazer apologia da mediocrida<strong>de</strong>. Antes, preten<strong>de</strong>mos estimular os colegas aver com alegria as vitórias (quando merecidas) <strong>de</strong> seus pares. “Se você não po<strong>de</strong> ser um pinheiro damontanha seja a relva do vale, mas seja a relva mais ver<strong>de</strong>jante”, escreveu o poeta. E diante dosucesso imerecido lembremo-nos que, pior do que sofrer injustiças é praticá-las.Sobretudo, mantenhamos sempre viva a idéia da transitorieda<strong>de</strong> da vida, aliada à outra <strong>de</strong> queestamos aqui para servir. Em nossa profissão isso significa ter o doente como preocupação máximaRev Bras Oftalmol. 2009; 68 (6): 325-6


326 Como (ainda) serf feliz na profissão– como preceitua nosso Código <strong>de</strong> Ética – e por ele manter-se atualizado, conhecer os próprioslimites e refrear a ambição <strong>de</strong>smedida por cifrões.A prática <strong>de</strong>sses conceitos resultará, com toda a certeza, em vida agradável e consciênciatranquila. E será nosso maior legado aos <strong>de</strong>scen<strong>de</strong>ntes, por mais <strong>de</strong>sprestigiada que esteja a éticanos dias que correm.Francisco Valter da Justa FreitasOftalmologista do Centro Visual do CearáRev Bras Oftalmol. 2009; 68 (6): 325-6


ARTIGO ORIGINAL 327Percepção da administração tópica ocular<strong>de</strong> drogas: vaporização x gotasTopical drug administration perception: spray x eyedropArlindo José Freire Portes 1 , Louise Pellegrino Gomes 2 , Beatriz Lopes Moura Brasil do Amaral 3 , Lívio Massa 4RESUMOObjetivo: Avaliar por questionário qual o nível <strong>de</strong> dificulda<strong>de</strong> para aplicação tópica <strong>de</strong>medicações oculares: vaporização ou gotas através da observação do paciente e qualmétodo foi tecnicamente melhor utilizado para aplicação <strong>de</strong> drogas tópicas oculares.Métodos: A pesquisa foi realizada no <strong>de</strong>correr <strong>de</strong> 2008 e 2009 no ambulatório <strong>de</strong> oftalmologiada Policlínica Ronaldo Gazolla. Foi utilizado um frasco <strong>de</strong> colírio e um <strong>de</strong>vaporizador com solução <strong>de</strong> carboximetilcelulose sódica a 0,5%. Cada participanteaplicou em um dos olhos a solução por vaporização ou instilação <strong>de</strong> gotas através <strong>de</strong> umprocesso randomizado. Foi perguntado ao paciente questões pré-formuladas sobre apraticida<strong>de</strong> <strong>de</strong> ambos os métodos. Resultados: Consi<strong>de</strong>rando o grau <strong>de</strong> dificulda<strong>de</strong> <strong>de</strong>administração tópica ocular: 36% acharam difícil ou muito difícil a vaporização e 14%a instilação <strong>de</strong> colírio. As dificulda<strong>de</strong>s <strong>de</strong>scritas pelos pacientes foram relatadas por64% dos pacientes para vaporização e por 34% para aplicação <strong>de</strong> colírio (p= 0,0027).Já 42% dos pacientes necessitaram <strong>de</strong> mais <strong>de</strong> uma instilação para aplicação do colírio,enquanto 36% dos pacientes precisaram <strong>de</strong> mais <strong>de</strong> uma aplicação para que a drogavaporizada tivesse contato com o olho (p= 0,49). Em 56% dos pacientes houve toque daponta do colírio com os cílios, já com o vaporizador não houve toque (p=0,0001). Conclusão:A vaporização foi o método mais seguro para evitar a contaminação do frasco. Amaior facilida<strong>de</strong> percebida pelos pacientes ao instilar o colírio em relação a vaporizaçãofoi <strong>de</strong>vido a terem apoiado a ponta do frasco nos tecidos oculares.Descritores: Volatilização; Administração tópica; Soluções oftálmicas; Lubrificantes;Olho/efeitos <strong>de</strong> drogas1Professor Adjunto <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio <strong>de</strong> Janeiro (RJ), Brasil;2Acadêmica do 6 o ano do Curso <strong>de</strong> Medicina da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio <strong>de</strong> Janeiro (RJ), Brasil;3Acadêmica do 6 o ano do Curso <strong>de</strong> Medicina da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio <strong>de</strong> Janeiro (RJ), Brasil;4Acadêmico do 6 o ano do Curso <strong>de</strong> Medicina da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio <strong>de</strong> Janeiro (RJ), Brasil.Trabalho realizado na Policlínica Ronaldo Gazolla da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio <strong>de</strong> Janeiro ( RJ), Brasil.Recebido para publicação em: 26/6/2009 - Aceito para publicação em 29/10/2009Rev Bras Oftalmol. 2009; 68 (6): 327-31


328Portes AJF, Gomes LP, Amaral BLMB, Massa LINTRODUÇÃOAo contrário dos tratamentos médicos baseadosna ingestão <strong>de</strong> medicamentos por via oral, ouso correto <strong>de</strong> colírios <strong>de</strong>pen<strong>de</strong> <strong>de</strong> uma técnica<strong>de</strong> administração baseada em movimentos <strong>de</strong> coor<strong>de</strong>naçãomotora fina associada à visão a<strong>de</strong>quada (1) .Muitos pacientes, notadamente os idosos, têm dificulda<strong>de</strong>em aplicar medicações oculares tópicas <strong>de</strong>vidoa não possuirem a<strong>de</strong>quada coor<strong>de</strong>nação motora ou visão<strong>de</strong> perto sem óculos (1) .Vários estudos <strong>de</strong>monstraram que o uso incorreto<strong>de</strong> colírios po<strong>de</strong> acarretar o aumento da absorçãosistêmica das drogas, com consequente maiortoxicida<strong>de</strong> (2) .O uso incorreto ocorre quando se usa númeroexcessivo <strong>de</strong> gotas por aplicação ou número excessivo<strong>de</strong> aplicações das gotas.É comum o uso <strong>de</strong> gotas gerar sensações <strong>de</strong>sagradáveiscomo queimação, ardência e lacrimejamento. Emvirtu<strong>de</strong> <strong>de</strong>stas sensações, as crianças são <strong>de</strong> um grupoem que o uso <strong>de</strong> gotas representa um transtorno para ainstituição <strong>de</strong> um tratamento, <strong>de</strong>vido à sua pouca cooperação,exacerbada pela necessida<strong>de</strong> <strong>de</strong> manterem osolhos abertos para o colírio ser aplicado.Alguns dos mais importantes fatores que levamos pacientes a não a<strong>de</strong>rirem a<strong>de</strong>quadamente ao tratamentocom colírios po<strong>de</strong>m estar relacionados à instilaçãoincorreta <strong>de</strong>stes, o que eleva o custo da terapêutica (3) .O uso do medicamento sob a forma vaporizada po<strong>de</strong>facilitar o tratamento em: crianças, pacientes com altasametropias, idosos, pós-operatórios, traumas oculares, etc.<strong>de</strong>vido a menor necessida<strong>de</strong> <strong>de</strong> visão da ponta do colírio,da proximida<strong>de</strong> dos cílios e <strong>de</strong> coor<strong>de</strong>nação motora (4) .Há estudos que <strong>de</strong>monstraram a eficácia dos medicamentosquando aplicados na forma <strong>de</strong> vaporização.No Brasil apenas um estudo <strong>de</strong>ste tipo foi publicado naRevista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> por Tavares e Portes(4) em 2006. Após extensa revisão bibliográfica nasbases <strong>de</strong> dados MedLine, LILACS e SciELO, não encontramosestudos nacionais ou internacionais sobre a percepçãoda aplicação tópica <strong>de</strong> drogas vaporizadas nosolhos.Os objetivos <strong>de</strong>ste trabalho foram:a) Avaliar <strong>de</strong> acordo com questionário qual o nível<strong>de</strong> facilida<strong>de</strong> ou dificulda<strong>de</strong> para aplicação tópica<strong>de</strong> medicações oculares: vaporização x gotas;b) Avaliar <strong>de</strong> acordo com a observação do pacientequal o método que foi utilizado com maior a<strong>de</strong>quaçãotécnica para aplicação <strong>de</strong> drogas tópicas oculares.MÉTODOSA pesquisa foi realizada no no <strong>de</strong>correr <strong>de</strong> 2008 e2009 no Ambulatório <strong>de</strong> <strong>Oftalmologia</strong> da PoliclínicaRonaldo Gazolla da Universida<strong>de</strong> Estácio <strong>de</strong> Sá – Rio<strong>de</strong> Janeiro (RJ), Brasil.Foi utilizado um frasco <strong>de</strong> colírio <strong>de</strong> solução <strong>de</strong>lubrificante ocular <strong>de</strong> carboximetilcelulose sódica a0,5% e um frasco <strong>de</strong> vaporizador previamente esterilizadocom óxido <strong>de</strong> etileno contendo a mesma solução(procedimento realizado em centro cirúrgico).No ambulatório havia uma ca<strong>de</strong>ira e uma maca,<strong>de</strong> forma que os pacientes po<strong>de</strong>riam realizar a instilação,tanto quanto possível, da mesma forma que estivessemhabituados a fazê-lo em seu próprio ambiente.Para cada participante foi fornecido um frasco <strong>de</strong>colírio <strong>de</strong> solução lubrificante ocular <strong>de</strong>carboximetilcelulose sódica a 0,5% e solicitado que efetuassea instilação do mesmo em um dos olhos previamenteselecionado. Através <strong>de</strong> um processo randomizadopor uma tabela pseudoaleatória do Excel só foram incluídosos pacientes que disseram saber instilar colírionos olhos.No outro olho foi solicitado que o participanteaplicasse a solução <strong>de</strong> carboximetilcelulose sódica a0,5% através do vaporizador.Todo processo foi acompanhado pelos autores.Após o processo foi perguntado ao paciente questõespré-formuladas sobre a praticida<strong>de</strong> <strong>de</strong> ambos osmétodos.A análise estatística foi realizada com auxílio daplanilha Excel 2007 para confecção <strong>de</strong> tabelas e do programaBiostat 5.0 para cálculo da significância estatística.Aspectos éticosEsta pesquisa foi submetida ao Comitê <strong>de</strong> Éticaem Pesquisa da Universida<strong>de</strong> Estácio <strong>de</strong> Sá.RESULTADOSDos 50 pacientes avaliados, 72% eram do sexofeminino com ida<strong>de</strong> média <strong>de</strong> 50,94 ± 18,16 anos.Em relação ao grau <strong>de</strong> dificulda<strong>de</strong> <strong>de</strong> administraçãotópica ocular, 36% acharam difícil ou muito difícil avaporização e 14% a instilação <strong>de</strong> colírio. Emcontrapartida, 70% acharam fácil ou muito fácil realizara instilação do colírio e 42% a vaporização(Tabela 1).As dificulda<strong>de</strong>s <strong>de</strong>scritas pelos pacientes para aaplicação tópica ocular foram relatadas por 64% dosRev Bras Oftalmol. 2009; 68 (6): 327-31


Percepção da administração tópica ocular <strong>de</strong> drogas: vaporização x gotas329pacientes para vaporização e por 34% para aplicação<strong>de</strong> colírio (p= 0,0027).A maior dificulda<strong>de</strong> dos pacientes estudados era“acertar o olho” tanto em relação ao colírio quanto emrelação à vaporização (Tabela 2).<strong>Nov</strong>enta por cento (90%) das vaporizações realizadasatingiram o globo ocular na primeira administração,enquanto 88% das gotas do colírio instiladas atingiramo olho na primeira aplicação (p= 0,74).Em 42% dos pacientes observados houve necessida<strong>de</strong><strong>de</strong> uma nova aplicação do colírio, o que ocorreutambém em 36% dos olhos que sofreram vaporização(p= 0,54).Em relação ao número <strong>de</strong> aplicações, 42% dos pacientesnecessitaram <strong>de</strong> mais <strong>de</strong> uma instilação para aplicaçãotópica do colírio, enquanto 36% dos pacientes precisaram<strong>de</strong> mais <strong>de</strong> uma aplicação para que a droga vaporizadativesse contato com o olho (p= 0,49) ( Tabela 3)Em 56% dos pacientes houve toque da ponta docolírio com os cílios, enquanto com o vaporizador nãohouve toque (p=0,0001).DISCUSSÃOApós extensa revisão bibliográfica em bancos <strong>de</strong>dados nacionais e internacionais, como Medline, Lilacse Scielo, não observamos nenhum estudo comparando apercepção do paciente sobre a instilação <strong>de</strong> colírios emrelação à vaporização <strong>de</strong> drogas tópicas oculares.Tavares et al. (4) em 2006 compararam a eficáciada midríase produzida por vaporizador ou gota com ouso <strong>de</strong> tropicamida a 1% em crianças <strong>de</strong> 5 a 10 anos enão encontraram diferença clínica e estatisticamentesignificativa da midríase causada pela vaporização emrelação a gota. Seria útil que se avaliasse também a percepçãodo paciente quanto a facilida<strong>de</strong> e praticida<strong>de</strong> douso da vaporização em relação à instilação <strong>de</strong> gotas, poisesta percepção afeta a fi<strong>de</strong>lida<strong>de</strong> ao tratamento e indicao quanto o modo <strong>de</strong> administração po<strong>de</strong> ser feito corretamentepossibilitando a eficácia.Solomon et al. (5) ressaltaram em seu estudo, em2003, a importância <strong>de</strong> uma instrução correta <strong>de</strong> comoinstilar colírios após observar lesão conjuntival pelo contatonão intencional da ponta do tubo com os olhos em12 pacientes avaliados com queixa <strong>de</strong> dor e hiperemiaocular aguda. Em nosso trabalho, observamos que nosolhos em que foram aplicados o colírio houve uma maiorquantida<strong>de</strong> <strong>de</strong> toques da ponta do frasco com o globoocular do que nos olhos com vaporizador (p=0,0001).No trabalho <strong>de</strong> Dietlein et al. (1) realizado em 2008,Tabela 1Grau <strong>de</strong> dificulda<strong>de</strong> da administraçãotópica ocular <strong>de</strong> drogasGrau <strong>de</strong> Colírio Vaporizaçãodificulda<strong>de</strong> (%) (%)1 8 102 62 323 16 224 10 265 4 10Total 100 1001- muito fácil; 2- fácil; 3- nem fácil nem difícil; 4- difícil; 5- muito difícilTabela 2Dificulda<strong>de</strong>s apresentadas pelos pacientes naadministração tópica <strong>de</strong> medicaçõesDificulda<strong>de</strong> Colírio Vaporizaçãon % n %Acertar o olho 13 26 9 18Piscar 4 8 0 0Assusta 1 2 4 8Gran<strong>de</strong> quantida<strong>de</strong> 1 2 4 8Um paciente po<strong>de</strong> ter referido mais <strong>de</strong> uma dificulda<strong>de</strong>Tabela 3Número <strong>de</strong> aplicações tópicas necessáriasaté a droga instilada atingir o olhoNúmero Colírio Vaporização<strong>de</strong> aplicações (%) (%)1 58 642 34 343 8 2Total 100 10068% dos pacientes que usavam um container lesavam aconjuntiva ou córnea. O risco <strong>de</strong> lesão tinha relaçaoinversamente proporcional a acuida<strong>de</strong> visual do melhorolho dos pacientes. Logo, pacientes idosos tiveram maioresproblemas na administração <strong>de</strong> containers e o sucessoda aplicação também po<strong>de</strong>ria <strong>de</strong>pen<strong>de</strong>r <strong>de</strong> uma experiênciaprévia com o uso <strong>de</strong>sse tipo <strong>de</strong> frasco .Segundo Höfling-Lima et al. (6) em um estudo realizadoem 2001 com 127 frascos <strong>de</strong> colírios com soroautólogo dos pacientes, 76,03% apresentaram contaminaçãoapós o término do conteúdo do frasco <strong>de</strong>vidoao toque da ponta do colírio com tecidos oculares. Osprincipais microrganismos encontrados foram:Rev Bras Oftalmol. 2009; 68 (6): 327-31


330Portes AJF, Gomes LP, Amaral BLMB, Massa LStaphylococcus coagulase-negativo (35,86%),Alcaligenes sp (21,73%), Klebsiella sp (20,65%),Bacillussp (9,78%) e outras bactérias (11,94%), o que mostrouque a contaminação po<strong>de</strong> ocorrer por microrganismospresentes na margem palpebral e conjuntiva por contatodireto no momento <strong>de</strong> instilação. É importante ressaltarque no frasco do colírio não havia conservantesjunto com o soro autólogo. Em nosso trabalho, observamosque a aplicação <strong>de</strong> drogas vaporizadas evita o contatoda ponta do aplicador com a conjuntiva. Evitandoassim a contaminação que foi <strong>de</strong>monstrada no estudo<strong>de</strong> Höfling-Lima.No presente estudo, a maioria dos pacientesinstilou o colírio erroneamente, permitindo o contato daponta do frasco com os cílios ou utilizando o canto medialdo olho como anteparo para realizar a aplicação. Istopo<strong>de</strong> explicar porque o colírio foi consi<strong>de</strong>rado <strong>de</strong> maisfácil aplicação.Observamos que a vaporização é uma forma<strong>de</strong> administração <strong>de</strong> drogas oculares menos complicadaque o método proposto por Morlet et al. (7) noano <strong>de</strong> 1997, que permite que o paciente instile omedicamento corretamente sem realizar o contatocom o olho e sem necessitar <strong>de</strong> algum objeto <strong>de</strong> apoio.O artigo explica que com frasco <strong>de</strong> colírio <strong>de</strong> cabeçapara baixo, o polegar <strong>de</strong>ve estabilizar o frasco aousar a testa como anteparo, enquanto a outra mãoretrai a pálpebra inferior para que a gota atinja asuperfície ocular.Gran<strong>de</strong> parte dos pacientes relatou maior dificulda<strong>de</strong>com a vaporização por não estarem acostumadoscom este ato, sugeriram que o auxílio <strong>de</strong> um espelhoseria necessário para melhor localização do olho para aaplicação. A dificulda<strong>de</strong> relatada em pressionar ovaporizador, pela força excessiva a ser utilizada, explica-sepelo fato <strong>de</strong> que o nosso dispositivo não foi calibradopara aplicação <strong>de</strong> medicamentos oculares e sim adaptadopara esta situação.Em 2005 Muller et al. (8) também questionaramem seu estudo a força necessária para aplicação do medicamentopor um dispositivo <strong>de</strong> vaporização e a quantida<strong>de</strong>excessiva <strong>de</strong> substância vaporizada. Testes realizadosin vitro compararam a força necessária para ainstilação <strong>de</strong> colírios e para o ato <strong>de</strong> vaporização. A umadistância <strong>de</strong> 3 cm o vaporizador teve um efeito <strong>de</strong> forçamecânica mais favorável do que as gotas para evitar o<strong>de</strong>sperdício.Encontramos na literatura outras possibilida<strong>de</strong>s<strong>de</strong> administração <strong>de</strong> drogas oculares para ajudar o pacientea administrar <strong>de</strong> maneira correta, Overaker et al. (9)publicaram em 1999 a criação <strong>de</strong> um novo tipo <strong>de</strong> frasco<strong>de</strong> colírio que po<strong>de</strong> ser instilado com o paciente com acabeça na posição vertical. O dispositivo <strong>de</strong>ve ser apoiadona bochecha do paciente e <strong>de</strong>ste emerge um tubocuja ponta é angulada para baixo <strong>de</strong> forma que ao apertaro frasco a gota cai <strong>de</strong> cima para baixo sem havernecessida<strong>de</strong> <strong>de</strong> virar o frasco.CONCLUSÃOA vaporização foi aplicada corretamente pelamaioria dos pacientes, não houve nenhum contato dovaporizador com os tecidos oculares, método mais seguropara evitar a contaminação do frasco.A maior facilida<strong>de</strong> percebida pelos pacientes aoinstilar o colírio em relação a vaporização <strong>de</strong>veu-se aofato <strong>de</strong> terem apoiado a ponta do frasco nos tecidos ocularesno canto medial dos olhos.ABSTRACTObjective: Evaluate how difficult it is to apply oculartopical medications based on patient observation andanswers to a questionnaire. Eye drops were comparedto vaporization. Methods: The study was performedin 2008 and 2009 in Policlinica Ronaldo Gazollaophthalmological ambulatory. An eyedropper and avaporizer with carboximetilcelulose 0,5% were used.Each individual tested applied randomly on one oftheir eyes an eye drop or vaporization. The patientshad to answer questions about the practice concerningboth forms of topical eye drug application. Results:36% informed that it was difficult or very difficult tovaporize and 14% to use eye drops. Problems<strong>de</strong>scribed by patients were consi<strong>de</strong>red by 64% forvaporization and by 34% for topical eye drop use (p=0,0027). 42% of the patients nee<strong>de</strong>d more than oneeye drop application to have eye drop contact , while36% of the patients nee<strong>de</strong>d more than one applicationof vaporization in or<strong>de</strong>r to get drug eye contact (p=0,49). In 56% of patients there were an eyedropper tipcontact with cilia, however there was not contact whenthe medicine was vaporized (p=0,0001). Conclusion:Vaporization was the safest method to avoid topicalocular drug contamination by manipulation; thegreater facility noticed for patients when theyadministered eye drops was achieved using eye tissuesas an eyedropper support.Keywords: Volatilization; Administration, topical;Ophthalmic solutions; Lubricants ; Eye/drug effectsRev Bras Oftalmol. 2009; 68 (6): 327-31


Percepção da administração tópica ocular <strong>de</strong> drogas: vaporização x gotas331REFERÊNCIAS1. Dietlein TS, Jordan JF, Luke C, Schild A, Dinslage S,Krieglstein GK. Self-application of single-use eyedrop containersin an el<strong>de</strong>rly population: comparisons with standar<strong>de</strong>yedrop bottle and with younger patients. Acta Ophthalmol.2008; 86(8): 856-9.2. Vai<strong>de</strong>rgorn, PG, Malta RFS, Borges AS, Menezes MDR,Trinda<strong>de</strong> ES, Santiago JBN. Técnica da instilação <strong>de</strong> colíriosem pacientes portadores <strong>de</strong> glaucoma crônico. Arq BrasOftalmol. 2003; 66(6):865-9.3. Stillitano IG, Lima MG, Ribeiro MP, Cabral J, Brandt CT.Impacto econômico do custo <strong>de</strong> colírios no tratamento doglaucoma. Arq Bras Oftalmol. 2005; 68(1): 79-84.4. Tavares MO, Portes AJF. Efeito midriático da tropicamida a1%: vaporização x gota, Rev Bras Oftalmol. 2006; 65(1):7-12.5. Solomon A, Chowers I, Raiskup F, Siganos CS, Frucht-PerJ. Inadvertent conjunctival trauma related to contact withdrug container tips: A masquera<strong>de</strong> syndrome. Ophthalmology.2003; 110(4):796–800.6. Höfling-Lima AL, Lima AS, Batistoso JA, Kawamura D,Chalita MRC, Alves LS, Farah ME. Contaminação <strong>de</strong> frascos<strong>de</strong> colírios <strong>de</strong> soro autólogo. Arq Bras Oftalmol. 2001; 64 (1):63-5.7. Morlet N, Kelly M, Morlet GC. A method of drop administration,Ophthalmic Surg Lasers. 1997; 28(8): 687-9.8. Muller F, Wagner M, Neubert RH. Comparative in vitro investigationof the forces exerted by eye drops and eyespray. Pharmazie. 2005; 60(8): 630-1.9. Overaker RF, Dodge BC, Epstein DL. A new eyedropdispensing bottle. Am J Ophthalmol. 1999;128(3): 368-70.En<strong>de</strong>reço para Correspondência:Arlindo PortesRua Riachuelo, nº 43 - LapaCEP 20230-010 - Rio <strong>de</strong> Janeiro - RJe-mail: portes@uol.com.brRev Bras Oftalmol. 2009; 68 (6): 327-31


332ARTIGO ORIGINALAvaliação da microbiota ocular em pacientescom disfunção do filme lacrimalEvaluation of conjunctival flora in patients with tear film dysfunctionMelissa Megumi Tomimatsu 1 , Manuela Maria Valença Cor<strong>de</strong>iro Barbosa 2 , Cecília Zorat Yu 3 , Flavio EduardoHirai 4 , Ana Luisa Höfling-Lima 5RESUMOObjetivo: Avaliar a microbiota conjuntival em olhos com disfunção do filme lacrimal, ea modificação <strong>de</strong>sta microbiota após a colocação <strong>de</strong> plug <strong>de</strong> silicone no canalículoinferior. Métodos: Série <strong>de</strong> casos intervencionais não comparativos para avaliar 68olhos <strong>de</strong> 41 pacientes com disfunção do filme lacrimal, durante o período <strong>de</strong> 2002 a2007, na Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo. Todos os pacientes foram submetidos àcolheita <strong>de</strong> amostras <strong>de</strong> raspado conjuntival <strong>de</strong> fundo-<strong>de</strong>-saco inferior para cultivo emBrain heart infusion broth. Os vinte e dois pacientes submetidos à colocação <strong>de</strong> plug <strong>de</strong>silicone repetiram a colheita <strong>de</strong> raspado conjuntival um mês após o procedimento.Resultados: Dos 68 olhos avaliados, 47 apresentaram crescimento bacteriano nas amostrascolhidas. <strong>Nov</strong>e diferentes espécies <strong>de</strong> bactérias foram i<strong>de</strong>ntificadas: Staphylococcuscoagulase negativa em 66,66%, Staphylococcus aureus em 13,72%, Corynebacteriumsp em 5,86%, Enterobacter aerogenes em 3,92%, Streptococcus hemolítico do grupoviridans em 1,96%, Serratia sp em 1,96%, Alcaligenes xylosoxidans spp em 1,96%,Corynebacterium xerosis em 1,96%, e Proteus mirabilis em 1,96%. Staphylococcuscoagulase negativa (SCN) foi o microrganismo mais frequentemente isolado tantoantes quanto após o plug <strong>de</strong> silicone. A sensibilida<strong>de</strong> do SCN à Oxacilina antes dacolocação do plug era <strong>de</strong> 87,50%, e, após, <strong>de</strong> 73,68%. Conclusão: A microbiota em olhoscom disfunção do filme lacrimal é bastante semelhante à encontrada em olhos normais.A resistência <strong>de</strong> SCN à Oxacilina foi um pouco maior após o implante do plug <strong>de</strong>silicone.Descritores: Síndrome do olho seco/microbiologia; Conjuntiva/microbiologia;Infecções estafilocócicas /microbiologia; Elastômeros <strong>de</strong> silicone1Médica Oftalmologista e Estagiária <strong>de</strong> Doenças Externas Oculares e Córnea do Departamento <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong>Fe<strong>de</strong>ral <strong>de</strong> São Paulo – UNIFESP - São Paulo (SP) - Brasil;2Médica Oftalmologista e Estagiária <strong>de</strong> Doenças Externas Oculares e Córnea do Departamento <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong>Fe<strong>de</strong>ral <strong>de</strong> São Paulo – UNIFESP - São Paulo (SP) - Brasil;3Biomédica responsável pelo Laboratório <strong>de</strong> Microbiologia do Departamento <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo– UNIFESP - São Paulo (SP) - Brasil;4Pós-graduando (doutorado) pela Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo – UNIFESP – São Paulo (SP) - Brasil;5Livre-docente, Professora Titular do Departamento <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo – UNIFESP - São Paulo(SP) - Brasil;Departamento <strong>de</strong> <strong>Oftalmologia</strong> da Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo – UNIFESP - São Paulo (SP) - Brasil.Recebido para publicação em: 7/7/2009 - Aceito para publicação em 5/11/2009Rev Bras Oftalmol. 2009; 68 (6): 332-7


Avaliação da microbiota ocular em pacientes com disfunção do filme lacrimal333INTRODUÇÃOOfilme lacrimal, além <strong>de</strong> lubrificar a superfícieocular, tem a importante função <strong>de</strong> protegê-lacontra a ação <strong>de</strong> vários patógenos. A lágrimacontém proteínas como a lisozima, a lactoferrina,imunoglobulina A, entre outras substâncias, que exercemativida<strong>de</strong> antimicrobiana (1-3) .Além disso, a mucinaproduzida por células caliciformes da conjuntiva promoveuma barreira física que impe<strong>de</strong> tanto a a<strong>de</strong>rênciacomo a penetração <strong>de</strong> muitos patógenos através doepitélio da superfície ocular (1-3) . Seal et al. mostraramque existe redução tanto da lactoferrina quanto dalisozima na lágrima <strong>de</strong> indivíduos com disfunção do filmelacrimal (4) .Alguns estudos <strong>de</strong>monstraram um aumento daativida<strong>de</strong> da enzima metaloproteinase-9 no epitéliocorneano, em resposta à insuficiência do filme lacrimal,e que resultou em perda das “tight junctions” da barreiraepitelial corneana (5) . A <strong>de</strong>ficiência do filme lacrimalaliada à fragilida<strong>de</strong> epitelial corneana em olhos secospo<strong>de</strong>m facilitar a instalação <strong>de</strong> infecções oculares.Terapias anti-inflamatórias como esterói<strong>de</strong>s tópicose ciclosporina A têm sido prescritas em vários casos<strong>de</strong> disfunção do filme lacrimal, com melhora dos sintomas.A administração <strong>de</strong> imunomoduladores po<strong>de</strong>, contudo,alterar a ativida<strong>de</strong> imune na superfície ocular, aumentandoassim a predisposição à infeçcão (1) .A oclusão <strong>de</strong> ponto lacrimal com plugs é umaopção terapêutica em casos <strong>de</strong> disfunção do filme lacrimal,uma vez que diminuem a drenagem lacrimal atravésdos canalículos (1, 6, 7) . Apesar <strong>de</strong> ser um método relativamentefácil e seguro, há estudos mostrando bactériascapazes <strong>de</strong> formar um biofilme a<strong>de</strong>rente à superfície doplug (6) .O objetivo <strong>de</strong>ste estudo foi avaliar a microbiotaconjuntival em olhos com disfunção do filme lacrimal, ea modificação <strong>de</strong>sta microbiota pela colocação do plug<strong>de</strong> silicone no canalículo inferior.MÉTODOSNesta série <strong>de</strong> casos intervencionais não comparativosforam avaliados 68 olhos <strong>de</strong> 41 pacientes (29 dosexo feminino, e 12 do sexo masculino) portadores <strong>de</strong>disfunção do filme lacrimal, durante o período <strong>de</strong> 2002 a2007. Os critérios <strong>de</strong> exclusão foram pacientes em uso<strong>de</strong> antibioticoterapia ou <strong>de</strong> terapias anti-inflamatóriascomo corticói<strong>de</strong>s ou imunossupressores tópicos ousistêmicos. Foram incluídos pacientes com diagnóstico<strong>de</strong> disfunção do filme lacrimal em tratamento somentecom lágrimas artificiais. O diagnóstico <strong>de</strong> disfunção dofilme lacrimal foi feito pela presença <strong>de</strong> pelo menos umdos sintomas (sensação <strong>de</strong> olho seco, ardor ou dor ousensação <strong>de</strong> corpo estranho, prurido e lacrimejamento),associados aos achados <strong>de</strong> exame oftalmológico(biomicroscopia avaliando-se conjuntiva e córnea, tempo<strong>de</strong> rompimento do filme lacrimal e teste com coloraçãovital rosa bengala).Na biomicroscopia anterior foram valorizados sinaiscomo presença <strong>de</strong> hiperemia conjuntival, muco,oleosida<strong>de</strong> excessiva do filme lacrimal, e <strong>de</strong> ceratitefilamentar. Tempo <strong>de</strong> rompimento do filme lacrimal inferiora 10 segundos foi consi<strong>de</strong>rado indicativo <strong>de</strong>disfunção do filme lacrimal (8) . No teste com coloraçãovital rosa bengala foi instilada 1 gota da solução a 1% eo paciente foi orientado a piscar várias vezes. Para interpretaçãodo resultado, sob luz anerita ver<strong>de</strong>, a superfícieocular foi dividida em 3 partes: conjuntiva bulbar nasale temporal e córnea. Cada área foi graduada <strong>de</strong> 0 a 3pontos, em que “0” significava ausência <strong>de</strong> coloração e“3” correspondia à coloração confluente, para um máximo<strong>de</strong> 9 pontos em cada olho. Olhos com valores superioresa 3 pontos foram consi<strong>de</strong>rados portadores <strong>de</strong>disfunção do filme lacrimal (9) .Durante o estudo, houve 22 pacientes (30 olhos),do total <strong>de</strong> 41 pacientes (68 olhos), que precisaram recorrerà oclusão <strong>de</strong> ponto lacrimal com plug <strong>de</strong> silicone.Estes pacientes foram submetidos à cultura <strong>de</strong> amostrascolhidas do fundo-<strong>de</strong>-saco conjuntival antes e após ummês da oclusão do ponto lacrimal inferior.Colheita e CulturaTodos os pacientes tiveram amostras, para cultivo,obtidas do fundo-<strong>de</strong>-saco da conjuntiva inferior, comzaragatoa estéril; o material foi imediatamente inoculadoem Brain heart infusion broth (BHI broth) (Difco, LePont <strong>de</strong> Claix/France) e encaminhado ao laboratório.Após apresentar turbi<strong>de</strong>z, as amostras <strong>de</strong> BHI foramsemeadas em meios sólidos <strong>de</strong> ágar sangue <strong>de</strong> carneiroa 5% (AS) (Difco, Le Pont <strong>de</strong> Claix/France) e ágar chocolate(AC) (Difco, Le Pont <strong>de</strong> Claix/France) para posteriori<strong>de</strong>ntificação dos microrganismos presentes.A sensibilida<strong>de</strong> aos antimicrobianos oxacilina,amicacina, tobramicina, ciprofloxacino, ofloxacino,gatifloxacino e moxifloxacino foi testada pelo método<strong>de</strong> disco difusão <strong>de</strong> acordo com as recomendações doClinical Laboratory Standards Institute (CLSI, Filadélfia,EUA) e <strong>de</strong>terminação das concentrações inibitóriasmínimas por Etest ® (AB Biodisk, Solna, Suécia). Todo oRev Bras Oftalmol. 2009; 68 (6): 332-7


334Tomimatsu MM, Barbosa MMVC, Yu CZ, Hirai FE, Höfling-Lima ALprocessamento das amostras e as respectivas análisesmicrobiológicas foram realizados no laboratório <strong>de</strong>microbiologia ocular do <strong>de</strong>partamento <strong>de</strong> <strong>Oftalmologia</strong>da Universida<strong>de</strong> Fe<strong>de</strong>ral <strong>de</strong> São Paulo.Análise estatísticaDados foram apresentados pela frequência, pelasmédias ± <strong>de</strong>svios-padrão ou proporções. Para comparação<strong>de</strong> variáveis categóricas foi utilizado o teste exato<strong>de</strong> Fisher. Valores <strong>de</strong> p ≤ 0,05 foram consi<strong>de</strong>rados estatisticamentesignificantes. A análise foi realizada com osoftware Stata v.10 (College Park, Texas).RESULTADOSA ida<strong>de</strong> dos pacientes incluídos no estudo variou<strong>de</strong> 20 a 88 anos com média ± <strong>de</strong>svio-padrão <strong>de</strong> 58,0 ±15,71 e mediana <strong>de</strong> 59 anos; 70,73% eram do sexo femininoe 29,27%, do masculino.Dos 68 olhos avaliados, 21 tiveram cultivos negativose 47 apresentaram crescimento bacteriano nasamostras colhidas. <strong>Nov</strong>e diferentes espécies <strong>de</strong> bactériasforam i<strong>de</strong>ntificadas: Staphylococcus coagulase negativa(SCN) em 34 amostras (66,66%), StaphylococcusTabela 1Microbiota dos 47 olhos com disfunção do filme lacrimal com cultura positivaBactéria Frequência %Staphylococcus coagulase negativa 34 66,66Staphylococcus aureus 7 13,72Corynebacterium sp 3 5,86Enterobacter aerogenes 2 3,92Corynebacterium xerosis 1 1,96Streptococcus hemolítico do grupo viridans 1 1,96Proteus mirabilis 1 1,96Serratia sp 1 1,96Alcaligenes xylosoxidans 1 1,96Total 51* 100* Dentre as 47 amostras, quatro tiveram crescimento <strong>de</strong> duas bactérias distintasTabela 2Microbiota dos olhos com cultura positiva antes e após o implante <strong>de</strong> plug*Bactéria Pré-plug % Pós-plug %Staphylococcus coagulase negativa 16 64 19 70,38Sensível à oxacilina 14 87,50 14 73,68Staphylococcus aureus 4 16 1 3,70Sensível à oxacilina 4 100 1 100Corynebacterium sp 1 4 1 3,70Serratia sp 1 4 1 3,70Streptococcus hemolítico do grupo viridans 1 4 3 11,12Alcaligenes xylosidans spp 1 4Corynebacterium xerosis 1 4Citrobacter feundii 1 3,70Moraxella nonliquefaciens 1 3,70Total 25 100 27 100*Alguns olhos apresentaram crescimento <strong>de</strong> mais <strong>de</strong> uma bactéria, conforme <strong>de</strong>talhado na Tabela 3Rev Bras Oftalmol. 2009; 68 (6): 332-7


Avaliação da microbiota ocular em pacientes com disfunção do filme lacrimal335Tabela 3Microbiota antes e após o implante <strong>de</strong> plug nos 30 olhos dos 22 pacientescom disfunção do filme lacrimal submetidos ao procedimentoID Olho Microbiota pré-plug Microbiota pós-plug1 D SCN SCNCitrobacter freundiiStreptococcus hemolíticodo grupo viridansE SCN SCNStreptococcus hemolíticodo grupo viridans2 D SCN SCN3 D Corynebacterium spp SCN4 D SCN SCN5 D SCN SCNE SCN SCN6 E cultura negativa cultura negativa7 D SCN SCNE S. aureus SCN8 E S. aureus SCN9 D SCN cultura negativaE cultura negativa cultura negativa10 D Alcaligenes xylosoxidans spp SCN11 E cultura negativa Corynebacterium spp12 D SCN SCN13 D Serratia spp cultura negativaE cultura negativa Serratia spp14 E SCN Streptococcus hemolíticoStreptococcus hemolítico do grupo viridansdo grupo viridans15 E Corynebacterium xerosis cultura negativa16 E cultura negativa SCN17 D SCN SCNS. aureusE SCN SCN18 D cultura negativa cultura negativa19 E SCN SCN20 D S. aureus cultura negativaE S. aureus cultura negativa21 E SCN SCNMoraxella nonliquefaciens22 D SCN SCNE SCN SCNaureus em 7 (13,72%), Corynebacterium sp em 3(5,86%), Enterobacter aerogenes em 2 (3,92%),Streptococcus hemolítico do grupo viridans em 1 (1,96%),Serratia sp em 1 (1,96%), Alcaligenes xylosoxidans sppem 1 (1,96%), Corynebacterium xerosis em 1 (1,96%),e Proteus mirabilis em 1 (1,96%) (Tabela 1). Dos 47olhos que apresentaram cultivo positivo, isolou-se umaúnica espécie <strong>de</strong> bactéria em 43 amostras, e em 4, duasespécies <strong>de</strong> bactérias foram isoladas.A oclusão <strong>de</strong> ponto lacrimal com plug <strong>de</strong> siliconefoi efetuada em 30 olhos <strong>de</strong> 22 pacientes (77,3% do sexofeminino e 22,7% do sexo masculino).Dos 30 olhos, 24 (80%) tiveram cultura positivaantes da colocação do plug, sendo 64% para SCN, 16%para S. aureus, e 20% para outras bactérias (Streptococcushemolítico do grupo viridans, Corynebacterium sp,Serratia sp, Alcaligenes xylosoxidans spp) (Tabela 2).Após o implante do plug, 22 (73,3%) dos 30 olhosapresentaram crescimento bacteriano, sendo que, emquatro <strong>de</strong>les, houve crescimento <strong>de</strong> mais <strong>de</strong> uma bactéria(Tabela 3). SCN continuou sendo o microrganismomais prevalente, com 70,38%, seguido peloStreptococcus hemolítico do grupo viridans, com 11,12%,e pelos outros (S. aureus, Serratia sp, AlcaligenesRev Bras Oftalmol. 2009; 68 (6): 332-7


336Tomimatsu MM, Barbosa MMVC, Yu CZ, Hirai FE, Höfling-Lima ALTabela 4Perfil <strong>de</strong> sensibilida<strong>de</strong> aos antimicrobianos das bactériasisoladas <strong>de</strong> pacientes com disfunção do filme lacrimalSCN(N=34)S. aureus(N=7)n % n %Oxacilina 30 88,23 7 100Amicacina 33 97,05 7 100Tobramicina 28 82,35 7 100Ciprofloxacino 29 85,29 7 100Ofloxacino 32 94,11 7 100Gatifloxacino 29 85,29 6 85,71Moxifloxacino 29 85,29 6 85,71N= número <strong>de</strong> isolados; n= número <strong>de</strong> isolados sensíveisxylosidans spp, Corynebacterium sp, Moraxellanonliquefaciens, e Citrobacter feundii) com 18,5% (Tabela2).Houve mudança na microbiota <strong>de</strong> 17 olhos(56,6%) após o implante do plug, mas isto não teve associaçãocom alterações <strong>de</strong> sinais e sintomas.Observou-se, neste estudo, que nos olhos comdisfunção do filme lacrimal, 88,23% dos SCN eram sensíveisà oxacilina, 82,35% eram sensíveis à tobramicina e85,29% à ciprofloxacino ou a moxifloxacino (Tabela 4).Nos olhos que necessitaram <strong>de</strong> plug, 87,5% dosSCN eram sensíveis à oxacilina antes, e 73,68% após acolocação do plug <strong>de</strong> silicone.DISCUSSÃOO presente estudo confirma dados anteriormentepublicados sobre a microbiota <strong>de</strong> pacientes comdisfunção do filme lacrimal, que apresentam maiorprevalência <strong>de</strong> Staphylococcus coagulase negativa(SCN) com ou sem oclusão do ponto lacrimal com plug<strong>de</strong> silicone (1, 10) . Diversos autores também <strong>de</strong>monstraramque SCN é o microrganismo mais prevalente emolhos normais (11, 12) .Ainda não há estudos <strong>de</strong>screvendoalterações da microbiota <strong>de</strong> acordo com a severida<strong>de</strong>da disfunção lacrimal.O método utilizado para avaliar a microbiota,neste estudo, foi o <strong>de</strong> cultivo em meios sólidos e líquidos.Estudos com PCR <strong>de</strong>screvem que este método é capaz<strong>de</strong> <strong>de</strong>tectar uma diversida<strong>de</strong> muito maior <strong>de</strong> bactériastanto na superfície <strong>de</strong> olhos saudáveis quanto na <strong>de</strong> olhoscom disfunção do filme lacrimal, enquanto que os métodos<strong>de</strong> cultivo convencionais frequentemente apresentamresultados negativos ou somente positivos paraSCN (10) . Isso ocorre porque o PCR po<strong>de</strong> <strong>de</strong>tectar materialgenético mesmo <strong>de</strong> microrganismos com difícil crescimentoem meios <strong>de</strong> cultura convencionais, especialmente<strong>de</strong>vido à limitada quantida<strong>de</strong> do microrganismona amostra. Entretanto, a elevada sensibilida<strong>de</strong> do examemolecular permite a <strong>de</strong>tecção <strong>de</strong> microrganismosque, apesar <strong>de</strong> presentes, po<strong>de</strong>m não estar relacionadosao quadro clínico. É muito difícil instituir um tratamentona ausência <strong>de</strong> sinais e sintomas oculares.É frequente que o paciente com disfunção do filmelacrimal apresente-se com sinais <strong>de</strong> olho vermelho esintomas <strong>de</strong> irritação ocular (5, 13) . As enzimas e toxinasproduzidas por muitas das bactérias que colonizam asuperfície ocular são capazes <strong>de</strong> <strong>de</strong>struir a camada <strong>de</strong>mucina e <strong>de</strong> lipídios, <strong>de</strong>sestabilizando ainda mais o filmelacrimal, e agravando a inflamação ocular e os sintomas<strong>de</strong> olho com disfunção do filme lacrimal (3, 10) . Emolhos com inflamação crônica há maior risco <strong>de</strong> existiremSCN multirresistentes (1, 14) . Em contrapartida, nesteestudo, observou-se que, em olhos com disfunção do filmelacrimal, 87,50% dos SCN eram sensíveis à oxacilina.Após a oclusão do ponto lacrimal inferior com plug <strong>de</strong>silicone, ainda 73,68% dos SCN isolados eram sensíveisà oxacilina.Neste estudo, apesar <strong>de</strong> 17 (56,6%) dos 30 olhosdos 22 pacientes submetidos ao plug terem apresentadoalteração da microbiota, não foi observado um padrão<strong>de</strong> modificação no perfil <strong>de</strong> microrganismos encontradosem olhos com disfunção do filme lacrimal após oimplante do plug <strong>de</strong> silicone. Além disso, não é possívelinterpretar se o plug foi o fator <strong>de</strong>terminante da mudança.Para tanto, o i<strong>de</strong>al seria que cada paciente submetidoao implante <strong>de</strong> plug tivesse um olho com plug e o outrosem, como controle.Sabe-se que a possibilida<strong>de</strong> <strong>de</strong> formação <strong>de</strong>Rev Bras Oftalmol. 2009; 68 (6): 332-7


Avaliação da microbiota ocular em pacientes com disfunção do filme lacrimal337biofilme é frequente em portadores <strong>de</strong> plug <strong>de</strong>silicone. O biofilme po<strong>de</strong> resultar em maior resistênciaa antibióticos (6, 15) . Este fator <strong>de</strong> formação <strong>de</strong>biofilme não foi avaliado neste estudo. Entretanto,houve o cuidado <strong>de</strong> não se tocar o plug durante acolheita das amostras.A disfunção do filme lacrimal geralmente ocorreem pacientes com ida<strong>de</strong> mais avançada, que eventualmenteprecisa ser submetida a cirurgias oculares.A presença <strong>de</strong> bactérias sensíveis antes e <strong>de</strong>poisda colocação do plug – i<strong>de</strong>ntificadas neste estudo –aparentemente não ressalta a necessida<strong>de</strong> <strong>de</strong> mudança<strong>de</strong> conduta terapêutica no pré-operatório <strong>de</strong>ssespacientes.CONCLUSÃOHá poucos estudos sobre a microbiota em olhoscom disfunção do filme lacrimal com ou sem plug <strong>de</strong>silicone, especialmente em nossa população.Este estudo <strong>de</strong>tectou maior prevalência <strong>de</strong> SCNna microbiota conjuntival <strong>de</strong> pacientes <strong>de</strong> nosso serviçocom disfunção do filme lacrimal. Os pacientes submetidosao implante <strong>de</strong> plug <strong>de</strong> silicone, apesar da modificaçãoda microbiota, não evoluíram clinicamente com infecção<strong>de</strong> superfície ocular.ABSTRACTPurpose: To evaluate conjunctival microbiota in eyes withtear film dysfunction and its modification after punctalocclusion with silicone plug. Methods: Non comparativeinterventional case series study to evaluate 68 eyes of 41patients with tear film dysfunction, from 2002 to 2007,followed in Fe<strong>de</strong>ral University of Sao Paulo. Samples forculture were all obtained from conjunctival swabs andinoculated in Brain heart infusion broth (BHI broth).Twenty two patients that un<strong>de</strong>rgone punctal plug occlusionrepeated culture procedure one month after plug insertion.Results: 47 of the 68 eyes evaluated had positive culturein their samples. Nine different types of bacteria werei<strong>de</strong>ntified: Coagulase negative Staphylococcus in 66,66%,Staphylococcus aureus, in 13,72%, Corynebacterium sp,in 5,86%, Enterobacter aerogenes, in 3,92%,Streptococcus hemolítico do grupo viridans, in 1,96%,Serratia sp, in 1,96%, Alcaligenes xylosoxidans spp, in1,96%, Corynebacterium xerosis, in 1,96%, and Proteusmirabilis in 1,96%. Coagulase negative Staphylococcus(CNS) was the most frequently isolated microorganismbefore and after punctal occlusion. CNS sensibility toOxacilin before plug insertion was 87,50%, and after,73,68%. Conclusion: Microbiota found in eyes with tearfilm dysfunction seems to be similar to that found in normaleyes. CNS resistance to oxacilin was slightly higherafter silicone plug insertion.Keywords: Dry eye syndromes/microbiology;Conjunctiva/microbiology; Staphylococcal infections/microbiology; Silicone elastomersREFERÊNCIAS1. Hori Y, Maeda N, Sakamoto M, Koh S, Inoue T, Tano Y. Bacteriologicprofile of the conjunctiva in the patients with dryeye. Am J Ophthalmol. 2008;146(5):729-34.2. Lemp MA. un<strong>de</strong>rstanding and managing dry eye disease. AmJ Ophthalmol. 2008;146(3):350-6.3. Berry M, Harris A, Lumb R, Powell K. Commensal ocular bacteria<strong>de</strong>gra<strong>de</strong> mucins. Br J Ophthalmol. 2002;86(12):1412-6.4. Seal DV, McGill JI, Mackie IA, Liakos GM, Jacobs P, GouldingNJ. Bacteriology and tear protein profiles of the dry eye. BrJ Ophthalmol. 1986 70(2):122-5.5. Pflugfel<strong>de</strong>r SC, Farley W, Luo L, Chen LZ, <strong>de</strong> Paiva CS, OlmosLC, et al. Matrix metalloproteinase-9 knockout confers resistanceto corneal epithelial barrier disruption in experimentaldry eye. Am J Pathol. 2005;166(1):61-71.6. Sugita J, Yokoi N, Fullwood NJ, Quantock AJ, Takada Y,Nakamura Y, et al. The <strong>de</strong>tection of bacteria and bacterialbiofilms in punctal plug holes. Cornea. 2001;20(4):362-5.7. Horwath-Winter J, Thaci A, Gruber A, Boldin I. Long-termretention rates and complications of silicone punctal plugs indry eye. Am J Ophthalmol. 2007;144(3):441-4.8. N RENPK-J. Olho Seco ou Ceratoconjuntivite Sicca. In: N.K-J, editor. Doenças da córnea e conjuntiva. Rio <strong>de</strong> Janeiro:Cultura Médica; 2007. p. 275-84.9. van Bijsterveld OP. Diagnostic tests in the Sicca syndrome.Arch Ophthalmol. 1969;82(1):10-4.10. Graham JE, Moore JE, Jiru X, Moore JE, Goodall EA, DooleyJS, et al. Ocular pathogen or commensal: a PCR-based studyof surface bacterial flora in normal and dry eyes. InvestOphthalmol Vis Sci. 2007 Dec;48(12):5616-23.11. Moeller CT, Branco BC, Yu MC, Farah ME, Santos MA,Hofling-Lima AL. Evaluation of normal ocular bacterial florawith two different culture media. Can J Ophthalmol. 2005Aug;40(4):448-53.12. Mino <strong>de</strong> Kaspar H, Koss MJ, He L, Blumenkranz MS, Ta CN.Antibiotic susceptibility of preoperative normal conjunctivalbacteria. Am J Ophthalmol. 2005 Apr;139(4):730-3.13. Solomon A, Dursun D, Liu Z, Xie Y, Macri A, Pflugfel<strong>de</strong>r SC.Pro- and anti-inflammatory forms of interleukin-1 in the tearfluid and conjunctiva of patients with dry-eye disease. InvestOphthalmol Vis Sci. 2001 Sep;42(10):2283-92.14. Grasbon T, Mino <strong>de</strong> Kaspar H, Klauss V. [Coagulase-negativestaphylococci in normal and chronically inflamed conjunctiva].Ophthalmologe. 1995 Dec;92(6):793-801.15. John JF, Harvin AM. History and evolution of antibiotic resistancein coagulase-negative staphylococci: Susceptibility profilesof new anti-staphylococcal agents. Ther Clin Risk Manag.2007 Dec;3(6):1143-52.Rev Bras Oftalmol. 2009; 68 (6): 332-7


338ARTIGO ORIGINALEstudo do comportamento da PIO<strong>de</strong> 24 horas e frequência <strong>de</strong> glaucomaem pacientes com síndrome da apnéiaobstrutiva do sonoStudy on 24 hours IOP study and glaucoma frequencyin patients with obstructive sleep apnea syndromeMaria Rosa Bet <strong>de</strong> Moraes Silva 1 , Silke Anna Theresa Weber 2RESUMOObjetivo: Determinar a frequência <strong>de</strong> glaucoma e avaliar o comportamento da pressãointraocular (PIO) <strong>de</strong> 24 horas em pacientes portadores da síndrome da apnéia obstrutiva dosono (SAOS). Métodos: Foi realizado estudo transversal em 11 pacientes consecutivos portadores<strong>de</strong> SAOS diagnosticados por polissonografia. Foram analisados dados <strong>de</strong>mográficos:ida<strong>de</strong>, sexo, raça/cor, peso, altura e doenças associadas. Os pacientes foram submetidos àavaliação oftalmológica completa que incluiu campo visual e também avaliação da pressãointraocular (PIO) <strong>de</strong> 24 horas com tonômetro <strong>de</strong> aplanação às 9h, 12h, 15h, 18h, 24h e 6h<strong>de</strong>itado e sentado. O critério para diagnóstico <strong>de</strong> glaucoma foi alteração <strong>de</strong> campo visual(CV) compatível com glaucoma e uma ou mais das seguintes alterações: relação escavaçãodisco ≥ 0,7, hemorragia, <strong>de</strong>feito em cunha, vaso em baioneta, sinal <strong>de</strong> Hoyt, assimetria > que0,2 entre as escavações dos dois olhos. O ângulo <strong>de</strong>via ser aberto sem alterações. Resultados:9 (82%) <strong>de</strong> 11 pacientes apresentaram glaucoma ou suspeita <strong>de</strong> glaucoma, sendo 9% glaucoma<strong>de</strong> pressão normal e 73% suspeita <strong>de</strong> glaucoma por apresentarem alterações do nervo ópticoou hipertensão ocular. A média dos valores <strong>de</strong> PIO dos 11 pacientes apresentou-se maiselevada às 6 horas quando os pacientes estavam <strong>de</strong>itados. Ocorreram flutuações <strong>de</strong> PIO ≥ 5mmHg em 7 (64%) dos pacientes sendo que ocorreram flutuações <strong>de</strong> até 14 mmHg e picos <strong>de</strong>PIO <strong>de</strong> até 32 mmHg. Conclusão: A SAOS po<strong>de</strong> ser um fator <strong>de</strong> risco importante para oesenvolvimento <strong>de</strong> glaucoma principalmente <strong>de</strong> pressão normal. Pacientes com SAOS <strong>de</strong>vemser referidos para o oftalmologista e os oftalmologistas <strong>de</strong>vem estar atentos para aassociação <strong>de</strong> distúrbios do sono em pacientes com glaucoma <strong>de</strong> ângulo aberto.Descritores: Apnéia do sono tipo obstrutiva; Pressão intra-ocular; Glaucoma <strong>de</strong> ânguloaberto; Técnicas <strong>de</strong> diagnóstico oftalmológico1Livre-docente, Professora Adjunta do Departamento <strong>de</strong> <strong>Oftalmologia</strong>, Otorrinolaringologia e Cirurgia <strong>de</strong> Cabeça e Pescoço daFaculda<strong>de</strong> <strong>de</strong> Medicina <strong>de</strong> Botucatu da Universida<strong>de</strong> Estadual “Julio <strong>de</strong> Mesquita Filho” – UNESP - Botucatu (SP), Brasil;2Doutora, Professora do Departamento <strong>de</strong> <strong>Oftalmologia</strong>, Otorrinolaringologia e Cirurgia <strong>de</strong> Cabeça e Pescoço da Faculda<strong>de</strong> <strong>de</strong>Medicina <strong>de</strong> Botucatu da Universida<strong>de</strong> Estadual “Julio <strong>de</strong> Mesquita Filho” – UNESP - Botucatu (SP), Brasil.Hospital das Clínicas da Faculda<strong>de</strong> <strong>de</strong> Medicina <strong>de</strong> Botucatu da Universida<strong>de</strong> Estadual “Julio <strong>de</strong> Mesquita Filho” – UNESP –Botucatu (SP), BrasilRecebido para publicação em: 22/4/2009 - Aceito para publicação em 13/11/2009Rev Bras Oftalmol. 2009; 68 (6): 338-43


Estudo do comportamento da PIO <strong>de</strong> 24 horas e frequência <strong>de</strong> glaucoma em pacientes com síndrome...339INTRODUÇÃOAprevalência do glaucoma varia conforme apopulação estudada, mas é consenso estar porvolta <strong>de</strong> 2% na população branca acima <strong>de</strong> 40anos (1) . A pressão intraocular é o principal fator <strong>de</strong> riscopara o glaucoma, mas déficits microcirculatórios, imunida<strong>de</strong>alterada, excitotoxicida<strong>de</strong> <strong>de</strong>ntre outros, po<strong>de</strong>mtambém estar implicados isoladamente ou <strong>de</strong> formacombinada (2,3) .A literatura tem mostrado que a prevalência <strong>de</strong>glaucoma em portadores <strong>de</strong> apnéia obstrutiva do sono émaior do que a da população em geral (4-6) . Mojon et al. (4)observaram 5 (7,2%) pacientes com glaucoma em 69portadores <strong>de</strong> síndrome <strong>de</strong> apnéia do sono. Dos cinco, trêstinham glaucoma <strong>de</strong> pressão normal e 2 glaucoma primário<strong>de</strong> ângulo aberto. Outros estudos sugerem associaçãoda apnéia do sono com glaucoma (7-9) . No entanto esta associaçãonão tem sido confirmada por outros autores. (10,11)Tendo em vista as contradições sobre a associação<strong>de</strong> glaucoma e síndrome da apnéia obstrutiva(SAOS) e a falta <strong>de</strong> estudos <strong>de</strong> avaliação <strong>de</strong> pressãointra-ocular (principal fator <strong>de</strong> risco do glaucoma) emportadores <strong>de</strong> SAOS, este estudo teve como objetivos:<strong>de</strong>terminar a frequência <strong>de</strong> glaucoma e avaliar o comportamentoda pressão intra-ocular (PIO) <strong>de</strong> 24 horasem pacientes portadores da síndrome da apnéiaobstrutiva do sono.MÉTODOSForam estudados 11 pacientes consecutivos, portadoresda síndrome da apnéia obstrutiva do sono comdiagnóstico polissonográfico do Ambulatório <strong>de</strong> Distúrbiosdo Sono do HC da Faculda<strong>de</strong> <strong>de</strong> Medicina <strong>de</strong>Botucatu – UNESP atendidos no período <strong>de</strong> abril à <strong>de</strong>zembro<strong>de</strong> 2006.Foram analisados os dados <strong>de</strong>mográficos dos pacientes:ida<strong>de</strong>, sexo, raça/cor, peso, altura, índice <strong>de</strong> massacorporal e doenças associadas.Todos os pacientes realizaram polissonografia <strong>de</strong>noite inteira. A SAOS foi diagnosticada quando o índice<strong>de</strong> distúrbios respiratórios (RDI) era maior do que 5. Dolaudo da polissonografia foram analisados os dados <strong>de</strong>RDI, eficiência do sono, saturação média <strong>de</strong> O 2e índice<strong>de</strong> <strong>de</strong>spertar para efeito <strong>de</strong> diagnóstico <strong>de</strong> SAOS (12,13) .Todos os pacientes foram submetidos a exameoftalmológico completo que incluiu: história e antece<strong>de</strong>ntes,medida da acuida<strong>de</strong> visual (AV) a 6 metros comtabela <strong>de</strong> Snellen, refração dinâmica, biomicroscopia dosegmento anterior, biomicroscopia do segmento posteriorcom lente <strong>de</strong> Volk <strong>de</strong> 78D, campo visual (C.V.) comprograma 24-2 do perímetro <strong>de</strong> Humphrey egonioscopia. Foi realizada CTD (curva tensional diária– com 8 medidas <strong>de</strong> PIO: 6h <strong>de</strong>itado, 6h sentado 9h, 12h,15h, 18h, 21h e 24h). As medidas foram feitas comtonômetro <strong>de</strong> Goldman exceto a das 6h (<strong>de</strong>itado) quefoi realizada com tonômetro <strong>de</strong> Perkins. Todas as avaliaçõesda PIO foram feitas em ambiente hospitalar porum dos autores (MRBMS).O critério utilizado para diagnóstico <strong>de</strong> glaucomafoi: alteração <strong>de</strong> C.V. <strong>de</strong> pelo menos 2 pontos adjacentesnão periféricos com p < 5% no gráfico “pattern<strong>de</strong>viation” associado a um ponto com p < 1%, em localizaçãocompatível com <strong>de</strong>feito glaucomatoso e GHToutsi<strong>de</strong> normal limits associada a uma ou mais das alteraçõesdo nervo óptico e camada <strong>de</strong> fibras nervosas: relaçãoescavação disco ≥ 0,7, hemorragia no disco, <strong>de</strong>feitoem cunha, vaso em baioneta, sinal <strong>de</strong> Hoyt, assimetria<strong>de</strong> escavação > 0,2, na presença <strong>de</strong> ângulo aberto semalterações à gonioscopia.O diagnóstico <strong>de</strong> glaucoma <strong>de</strong> pressão normal foidado quando o paciente apresentava as alterações <strong>de</strong>scritasacima associadas a PIO < 21 mmHg.O critério utilizado para suspeito <strong>de</strong> glaucomafoi: CV anormal, porém não confirmado com outro exame,PIO > 21 mmHg, sem alteração <strong>de</strong> CV e <strong>de</strong> discoóptico, relação escavação / disco ≤ 0,6, perda <strong>de</strong> padrãoisn’t, assimetrias <strong>de</strong> escavação ≤ 0,2 com CV normal eângulo aberto sem alterações à gonioscopia.Os dados <strong>de</strong> PIO foram <strong>de</strong>scritos como média (M)e <strong>de</strong>svio padrão (DP) e foram comparados os valores <strong>de</strong>média <strong>de</strong> PIO dos olhos direitos (OD) e olhos esquerdos(OE) por meio do teste t-Stu<strong>de</strong>nt <strong>de</strong> amostras pareadas,consi<strong>de</strong>rado significativo quando p < 0,05.O estudo foi aprovado pelo Comitê <strong>de</strong> Ética emPesquisa (CEP 38/2006) e todos os pacientes assinaramTermo <strong>de</strong> Consentimento Livre e Esclarecido.RESULTADOSDos 11 pacientes, 3 (27,2%) eram do sexo femininoe 8 (72,7%) do sexo masculino. A ida<strong>de</strong> média dos 11pacientes foi <strong>de</strong> 51,2 anos, sendo a das mulheres <strong>de</strong> 51,3anos e a dos homens <strong>de</strong> 51,2. Dos 11 pacientes, 9 erambrancos e 2 negros/pardos (Tabela 1).Quanto ao RDI, 5 pacientes apresentaram RDI >30 n/h (número <strong>de</strong> distúrbios respiratórios por hora), consi<strong>de</strong>radoSAOS grave, 5 pacientes RDI entre 15 e 30 n/h, consi<strong>de</strong>rado SAOS mo<strong>de</strong>rada e somente 1 pacienteapresentou SAOS leve com RDI entre 5 a 15 n/h.O valor da média do índice <strong>de</strong> massa corporal(IMC) foi <strong>de</strong> 33,56 Kg/m 2 . Consi<strong>de</strong>rando-se como obesida<strong>de</strong>IMC > 30 Kg/m 2 , todos os pacientes individualmenteapresentaram IMC compatível com obesida<strong>de</strong>,exceto o <strong>de</strong> número 5 (IMC = 24,98 Kg/m 2 ).Rev Bras Oftalmol. 2009; 68 (6): 338-43


340Silva MRBM, Weber SATTabela 1Caracterização dos 11 portadores <strong>de</strong> SAOS (síndrome da apnéia obstrutivado sono) quanto à ida<strong>de</strong> (anos) sexo, raça, IMC e doenças sistêmicasassociadas (UNESP – Botucatu – 2006)Paciente Ida<strong>de</strong> (anos) Sexo Raça IMC Doenças sistêmicas1 41 M B 39,87 –2 52 M B 38,69 Doença coronária3 50 F N 36,41 HA4 67 M B 30,86 HA5 63 M B 24,98 HA, artrite reumatiói<strong>de</strong>6 57 M P 33,59 Diabetes7 48 F B 31,24 Doença coronária8 35 M B 33,83 –9 56 F B 25,089 HA10 48 M B 33,31 Hanseníase11 47 M B 37,27 HAMÉDIA 51,27 33,56M- masculino; F- feminino; B- branco; P- pardo; N- negro; IMC- índice <strong>de</strong> massa corporal (Kg/m 2 ); HA – hipertensãoarterialTabela 2Valores <strong>de</strong> pressão intraocular (PIO) em mmHg <strong>de</strong> ambos os olhos nosdiferentes horários, média e <strong>de</strong>svio-padrão da média da PIO (mmHg) <strong>de</strong> ambos os olhose valores <strong>de</strong> p em portadores <strong>de</strong> SAOS (UNESP – Botucatu – 2006)9h 12h 15h 18h 21h 24h 6h D 6h SOD OE OD OE OD OE OD OE OD OE OD OE OD OE OD OE1 17 16 20 22 17 18 19 18 15 11 19 14 21 16 25 232 19 18 20 21 20 22 20 19 18 23 17 17 20 20 18 173 15 14 16 16 14 14 14 15 12 12 12 15 14 13 14 134 16 14 13 15 16 15 15 14 15 14 16 12 15 17 14 165 14 14 14 14 14 14 13 13 15 14 16 14 16 17 16 146 17 17 12 13 11 12 13 12 11 12 10 10 20 20 15 157 20 21 15 15 14 14 14 13 18 21 19 24 28 28 20 218 24 24 20 18 20 20 20 20 21 21 19 19 24 32 24 279 9 8 12 12 14 12 14 12 11 10 12 12 13 12 14 1210 10 10 14 14 17 15 16 14 15 13 19 18 25 25 19 2011 12 12 12 12 10 10 9 9 8 8 8 14 8 10 14 12M 15,73 15,27 15,27 15,64 15,18 15,09 15,18 14,45 14,45 14,45 15,18 15,36 18,55 19,09 17,55 17,27DP 4,43 4,65 3,29 3,38 3,22 3,59 3,37 3,33 3,75 4,97 4,02 3,93 5,94 6,86 4,06 4,90p 0,095 0,306 0,809 0,023 1,000 0,826 0,573 0,625OD- olho direito; OE- olho esquerdo; M- média; DP- <strong>de</strong>svio padrão; p- comparação entre médias <strong>de</strong> OD e OE por teste <strong>de</strong> t <strong>de</strong> Stu<strong>de</strong>nt para amostras pareadasQuanto às doenças associadas, foram encontrados:hipertensão arterial em 6, doença coronariana em 2,diabetes em 1, artrite reumatói<strong>de</strong> em 1 e hanseníase em1. Apenas 2 pacientes não apresentavam nenhuma outrapatologia (Tabela 1).Todos os pacientes negavam ter glaucoma e negavamantece<strong>de</strong>ntes <strong>de</strong> glaucoma na família.A Tabela 2 apresenta os valores das medidas daPIO <strong>de</strong> 24 horas (9h, 12h, 15h, 18h, 21h, 24h, 6h <strong>de</strong>itado e6h sentado) <strong>de</strong> ambos os olhos (AO) dos 11 pacientes,assim como a média e <strong>de</strong>svio-padrão dos valores emcada um dos horários e valores <strong>de</strong> p da comparação dosvalores <strong>de</strong> média <strong>de</strong> PIO entre os dois olhos. A médiados valores <strong>de</strong> PIO <strong>de</strong> 9 horas foi semelhante em AO,sendo <strong>de</strong> 15,73 mmHg e 15,27 mmHg respectivamenteem OD e OE (p = 0,095). A análise estatística mostrouque não houve diferença entre a PIO <strong>de</strong> OD e OE,exceto às 18:00h (p = 0,02). A partir das 12h observa-seque a PIO sofre ligeira queda que persiste até as 21h,quando se inicia elevação culminando com o pico às 6 hRev Bras Oftalmol. 2009; 68 (6): 338-43


Estudo do comportamento da PIO <strong>de</strong> 24 horas e frequência <strong>de</strong> glaucoma em pacientes com síndrome...341Tabela 3Presença <strong>de</strong> glaucoma ou suspeita <strong>de</strong> glaucoma nosportadores <strong>de</strong> Síndrome da apnéia obstrutiva do sono- SAOS (UNESP – Botucatu – 2006).PacienteGlaucoma/suspeitoODOE1 suspeito* suspeito*2 – suspeito*3 – suspeito4 suspeito suspeito5 – %6 GPN suspeito7 suspeito* suspeito*8 suspeito* suspeito*9 suspeito suspeito10 suspeito* suspeito*11 – %suspeito* - por apresentar pressão intraocular > 21 mmHg; suspeito – por apresentaralterações <strong>de</strong> nervo óptico e campo visual;OD – olho direito; OE – olhoesquerdo; GPN – glaucoma <strong>de</strong> pressão normal(paciente <strong>de</strong>itado) cujos valores foram: 18,55 mmHg parao OD e <strong>de</strong> 19,09 mmHg para o OE.A média dos valores <strong>de</strong> PIO às 6 h com o pacientesentado foram menores do que os valores com o paciente<strong>de</strong>itado, sendo a diferença <strong>de</strong> 1 mmHg para o OD e1,82 mmHg para o OE (Tabela 2 e Figura 1).Dos 22 olhos dos 11 pacientes, 1 olho apresentouglaucoma <strong>de</strong> pressão normal (OD do nº 6). Outros 6 olhos(OE- nº 3, AO- nº 4, OE- nº 6 e AO nº 9) foram consi<strong>de</strong>radossuspeitos <strong>de</strong> glaucoma por apresentarem alteraçõesdo nervo óptico e <strong>de</strong> campo visual. Pacientes que apresentaramalterações apenas <strong>de</strong> CV não foram consi<strong>de</strong>radossuspeitos pelo fato do exame não ter sido repetido(Tabela 3).Os pacientes <strong>de</strong> números 1, 2, 7, 8 e 10 apresentaramvalores <strong>de</strong> PIO maiores do que 21 mmHg, mas nãoapresentaram alterações <strong>de</strong> nervo óptico e campo visual(Tabelas 2 e 3).DISCUSSÃOA SAOS é uma doença comum, <strong>de</strong>finida comoobstrução intermitente das vias aéreas superiores duranteo sono, associada à hipóxia, variação <strong>de</strong> pressãointratorácica, ativação simpática e fragmentação do sono.Esses fenômenos são responsáveis por repercussõescardiovasculares, que incluem hipertensão arterial epulmonar, arritmias cardíacas, infarto do miocárdio eneurológicas como o aci<strong>de</strong>nte vascular cerebral (13-15) .A SAOS também tem sido apontada como fator<strong>de</strong> risco para o <strong>de</strong>senvolvimento do glaucoma principalmentedo glaucoma <strong>de</strong> pressão normal (6,7) .Figura 1: Curva tensional diária 8 medidas <strong>de</strong> pressão intraocular(PIO) em mmHg <strong>de</strong> ambos os olhos <strong>de</strong> portadores da Síndrome daapnéia obstrutiva do sono – SAOS (UNESP – Botucatu – 2006)No presente estudo que inclui pacientes brancose negros foi encontrada frequência <strong>de</strong> glaucoma <strong>de</strong> 4,5%(1 <strong>de</strong> 22 olhos) e consi<strong>de</strong>rando-se frequência por pacientefoi <strong>de</strong> 9% (1 <strong>de</strong> 11 pacientes).A prevalência <strong>de</strong> glaucoma em portadores <strong>de</strong>SAOS varia <strong>de</strong> 4,4 a 7,2% na população branca (4-6) masnão há nenhum estudo que inclua negros na amostra. Naliteratura apontada só um trabalho (6) tem grupo controle,portanto apenas este po<strong>de</strong>ria usar o termo prevalência.Neste estudo um paciente apresentou glaucoma<strong>de</strong> pressão normal. Mojon et al. (4) encontraram em populaçãosuíça branca, 5 (7,2%) casos <strong>de</strong> glaucoma sendo 3primários <strong>de</strong> ângulo aberto e 2 <strong>de</strong> pressão normal.No estudo <strong>de</strong> Bezerra (5) , que não faz referência àraça/cor, foram encontrados 4 (4,4%) portadores <strong>de</strong>glaucoma mas os autores falam apenas em glaucoma <strong>de</strong>ângulo aberto não ficando claro se são glaucomas <strong>de</strong>pressão normal ou glaucomas primários <strong>de</strong> ângulo aberto.Deve ser ressaltado que neste estudo (5) o diagnóstico<strong>de</strong> glaucoma foi feito por meio da análise <strong>de</strong> prontuários,sendo examinados apenas os 4 pacientes que apresentaramhistória positiva para glaucoma.No estudo <strong>de</strong> Sergi et al. (6) em pacientes brancos,e com grupo controle, os 3 casos (5,9%) apresentaramglaucoma <strong>de</strong> pressão normal.Apesar da patogênese do glaucoma <strong>de</strong> pressãonormal ainda não estar bem <strong>de</strong>finida, há evidências <strong>de</strong>que a hipoperfusão do nervo óptico causada por doençasisquêmicas crônicas e progressivas po<strong>de</strong>riam ser a causa(16) . A SAOS está associada com episódios <strong>de</strong> hipóxiaprolongada, com excitação simpática aguda e prolonga-Rev Bras Oftalmol. 2009; 68 (6): 338-43


342Silva MRBM, Weber SATda compatível com aumento do tônus vascular. A SAOSaumenta a liberação <strong>de</strong> hormônios <strong>de</strong> ação vascular:catecolaminas, peptí<strong>de</strong>os natriuréticos atriais,angiotensina II, vasopressina e endotelina (13,14) . Assim ahipóxia prolongada característica da síndrome po<strong>de</strong>riacausar dano direto ao nervo óptico. Outras possibilida<strong>de</strong>spara explicar o dano ao nervo óptico seriam a alteraçãoda autoregulação do fluxo sangüíneo na cabeçado nervo óptico (17) , secundária a apnéias prolongadas erepetidas ou secundária a hipertensão arterial earterioesclerose (18,19) causadas pela própria SAOS ouainda <strong>de</strong>sequilíbrio entre óxido nítrico e endotelina (19) .Chama atenção neste estudo o gran<strong>de</strong> número <strong>de</strong>suspeitos <strong>de</strong> glaucoma, 9 (82%) <strong>de</strong> 11 pacientes. Dos 9, 5tiveram o diagnóstico <strong>de</strong> suspeita <strong>de</strong> glaucoma por apresentaremà CTD picos pressóricos <strong>de</strong> até 32 mmHg egran<strong>de</strong>s flutuações da PIO (PIO maior – PIO menor) <strong>de</strong>até 14 mmHg. Os picos pressóricos ocorreram sempreno horário das 6 horas da manhã quando o paciente estava<strong>de</strong>itado. Após levantar a PIO já sofria queda, masmanteve-se maior do que nos outros horários. A PIO elevadana posição supina po<strong>de</strong>ria ser também outro fatorcontribuinte para o <strong>de</strong>senvolvimento do glaucoma nospacientes com SAOS. Foi observada PIO aumentada emposição supina no horário das 6 horas em portadores <strong>de</strong>glaucoma tratados ou com hipertensão ocular (20) . Tambémem indivíduos normais observou-se PIO aumentadaem posição supina, porém é maior nos pacientes comglaucoma <strong>de</strong> pressão normal (21-23) o que po<strong>de</strong> reduzir ofluxo sanguíneo ocular nestes pacientes (24) .Goldblum et al. (25) avaliaram a PIO <strong>de</strong> 3 pacientesportadores <strong>de</strong> SAOS e glaucoma <strong>de</strong> pressão normal duranteo sono em Laboratório do Sono. As avaliações da PIOforam feitas em 2 momentos: <strong>de</strong> respiração normal e nofinal <strong>de</strong> apnéias prolongadas sendo os valores semelhantes.Assim a PIO elevada em nossos pacientes é provavelmentepostural e não por efeito da apnéia prolongada.Não foi encontrado na literatura nenhum estudodo comportamento da PIO <strong>de</strong> 24 horas em pacientesportadores <strong>de</strong> SAOS. Apesar <strong>de</strong>ste trabalho não ter grupocontrole, os picos e as flutuações da PIO observadosforam muito maiores do que o esperado na populaçãonormal. Deve ser ainda ressaltado que os cinco pacientesque apresentaram picos <strong>de</strong> PIO > 21 mmHg (números1, 2, 7, 8 e 10) não apresentavam no momento doexame alterações <strong>de</strong> nervo óptico e/ou da camada <strong>de</strong>fibras nervosas.Mesmo sendo glaucoma <strong>de</strong> pressão normal, oglaucoma mais frequentemente associado a SAOS, Sergiet al. (6) encontraram PIO mais elevada nestes pacientes doque nos controles, o que sugere que também a PIO teriapapel na fisiopatogenia do glaucoma associado à SAOS.Fortalecem a relação glaucoma/SAOS não só agran<strong>de</strong> prevalência <strong>de</strong> glaucoma na SAOS, e a gran<strong>de</strong>prevalência <strong>de</strong> SAOS (<strong>de</strong> 46% a 50%) em portadores<strong>de</strong> glaucoma (7,9) , mas também a <strong>de</strong>monstração <strong>de</strong>Kremmer et al. (26) <strong>de</strong> que a terapia com ventilação positivanasal (CPAP) melhora o curso das duas doenças.Este é um estudo observacional, assim como o sãoos estudos citados anteriormente e portanto não permiteconclusões <strong>de</strong> causa e efeito da SAOS levando ao glaucoma,mas mostra associação da SAOS com glaucoma <strong>de</strong> ânguloaberto. Mostra ainda alto risco <strong>de</strong> <strong>de</strong>senvolvimento <strong>de</strong>glaucoma naqueles pacientes que apresentaram gran<strong>de</strong>spicos pressóricos (27) e gran<strong>de</strong>s flutuações na avaliação daPIO <strong>de</strong> 24h, picos estes observados às 6 h com paciente<strong>de</strong>itado e portanto fora do horário da avaliação normal doconsultório. As flutuações da PIO têm sido apontadas comoimportante fator <strong>de</strong> progressão do glaucoma (28) e o OHTS (29)mostrou que quanto maior a PIO e menor a espessuracorneana maior é o risco <strong>de</strong> <strong>de</strong>senvolver glaucoma, o quesugere que os pacientes com PIO elevada terão maior probabilida<strong>de</strong><strong>de</strong> <strong>de</strong>senvolver glaucoma.Os resultados <strong>de</strong>ste estudo em portadores <strong>de</strong>SAOS mostraram portanto alta freqência <strong>de</strong> glaucomae <strong>de</strong> suspeitos <strong>de</strong> glaucoma. Apesar da amostra pequenae <strong>de</strong> não haver grupo controle, os dados sugerem queportadores <strong>de</strong> SAOS têm maior risco <strong>de</strong> <strong>de</strong>senvolverglaucoma do que indivíduos sem SAOS, e portanto <strong>de</strong>veriamser submetidos à avaliação oftalmológica parapesquisa <strong>de</strong> glaucoma.CONCLUSÃOA SAOS po<strong>de</strong> ser um fator <strong>de</strong> risco importantepara o <strong>de</strong>senvolvimento <strong>de</strong> glaucoma principalmente<strong>de</strong> pressão normal.Pacientes com SAOS <strong>de</strong>vem ser referidos para ooftalmologista e os oftalmologistas <strong>de</strong>vem estar atentospara a associação <strong>de</strong> distúrbios do sono em pacientescom glaucoma <strong>de</strong> ângulo aberto.ABSTRACTPurpose: To <strong>de</strong>termine the frequency of glaucoma an<strong>de</strong>valuate the behavior of 24-hour intraocular pressure inpatients with the obstructive sleep apnea syndrome (OSAS).Methods: Eleven consecutive patients with OSAS,diagnosed by polysonography, were avaliated in a cross –sectional study. Demographic data were analyzed: age, sex,race/color, weight, height and associated diseases. Thepatients were submitted to complete ophthalmologicexamination, including the visual field, as well as to 24-hour intra-ocular pressure (IOP) evaluation by anapplanation tonometer at 9h, 12h, 15h, 18h, 24h and 6h inthe lying and sitting positions. The diagnostic criterion forRev Bras Oftalmol. 2009; 68 (6): 338-43


Estudo do comportamento da PIO <strong>de</strong> 24 horas e frequência <strong>de</strong> glaucoma em pacientes com síndrome...343glaucoma was alteration of the visual field (VF) compatiblewith glaucoma and one or more of the following alterations:cup-disc ratio ≥ 0.7, hemorrhage, wedge-shaped <strong>de</strong>fect,bayonet-shaped vessels, Hoyt’s sign, asymmetry > than 0.2between cup/disc ratio of the eyes. The angle should beopened without alterations. Results: 9 (82%) of 11 patientsshowed glaucoma or were suspected to have glaucoma,9% of which exhibited normal tension glaucoma and 73%were suspected to have glaucoma for presenting alterationsin the optic nerve or ocular hypertension. The mean for theIOP values of the 11 patients was observed to be the highestat 6 o’clock, when they were lying down. Variations of IOP≥ 5 mmHg occurred in 7 (64%) of the patients, andvariations of up to 14 mmHg and IOP peaks of up to 32mmHg were observed. Conclusion: OSAS may be animportant risk factor for the <strong>de</strong>velopment of glaucoma,particularly that of normal tension glaucoma. Patients withOSAS must be referred to an ophthalmologist and thoseprofessionals must be attentive to the association of sleepdisor<strong>de</strong>rs in patients with open-angle glaucoma.Keywords: Sleep apnea, obstructive; Intraocularpressure; Glaucoma, open-angle; Diagnostic techniques,ophthalmologicalREFERÊNCIAS1. Wilson MR, Martone JF. Epi<strong>de</strong>miology of chronic open-angleglaucoma. In: Ritch R, Bruce Shields M, Krupin T. The Glaucomas.2nd ed. St Louis: Mosby; 1998. p. 753-68.2. Weinreb RN, Khaw PT. Primary open-angle glaucoma. Lancet.2004; 363(9422):1711-20.3. Me<strong>de</strong>iros FA, Weinreb RN. Medical backgroun<strong>de</strong>rs: glaucoma.Drugs Today (Barc). 2002; 38(8):563-70.4. Mojon DS, Hess CW, Goldblum D, Fleischhauer J, Koerner F,Bassetti C, et al. High prevalence of glaucoma in patientswith sleep apnea syndrome. Ophthalmology. 1999;106(5):1009-12.5. Bezerra ML. A prevalência do glaucoma nos pacientes comsíndrome da apnéia/hipopnéia do sono do Instituto do Sonoda Universida<strong>de</strong> Estácio <strong>de</strong> Sá. In: IX Congresso Brasileiro<strong>de</strong> Sono; 2003 <strong>Nov</strong> 5-8; Vitória. Anais. Vitória: <strong>Socieda<strong>de</strong></strong><strong>Brasileira</strong> <strong>de</strong> Sono; 2003. p. 45.6. Sergi M, Salerno DE, Rizzi M, Blini M, Andreoli A, MessenioD, et al. Prevalence of normal tension glaucoma in obstructivesleep apnea syndrome patients. J Glaucoma. 2007;16(1):42-6.7. Mojon DS, Hess CW, Goldblum D, Boehnke M, Koerner F,Gugger M, et al. Normal-tension glaucoma is associated withsleep apnea syndrome. Ophthalmologica. 2002; 216(3):180-4.8. Mojon DS, Hess CW, Goldblum D, Bohnke M, Korner F, MathisJ. Primary open-angle glaucoma is associated with sleep apneasyndrome. Ophthalmologica. 2000; 214(2):115-8.9. Marcus DM, Costari<strong>de</strong>s AP, Gokhale P, Papastergiou G, Miller JJ,Johnson MH, Chaudhary BA. Sleep disor<strong>de</strong>rs: a risk factor fornormal – tension glaucoma. J Glaucoma. 2001; 10(3):177-83.10. Girkin CA, McGwin G Jr, McNeal SF, Owsley C. Is there anassociation between pre-existing sleep apnoea and the <strong>de</strong>velopmentof glaucoma? Br J Ophthalmol. 2006; 90(6): 679-81.11. Geyer O, Cohen N, Segev E, Rath EZ, Melamud L, Peled R,et al. The prevalence of glaucoma in patients with sleep apneasyndrome: same as in the general population. Am JOphthalmol. 2003; 136(6):1093-6.12. Sleep-related breathing disor<strong>de</strong>rs in adults: recommendationsfor syndrome <strong>de</strong>finition and measurement techniques in clinicalresearch. The Report of an American Aca<strong>de</strong>my of SleepMedicine Task Force. Sleep. 1999; 22(5):667-89.13. Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. Theoccurrence of sleep- disor<strong>de</strong>red breathing among middleagedadults. N Engl J Med. 1993; 328(17):1230-5.14. Stradling JR, Crosby JH. Relation between systemic hypertensionand sleep hypoxaemia or snoring: analysis in 748 mendrawn from general practice. Br Med J. 1990; 300(6717):75-8.15. Strobel RJ, Rosen RC. Obesity and weight loss in obstructivesleep apnea: a critical review. Sleep. 1996; 19(2):104-15.16. Hayreh SS, Zimmerman MB, Podhajsky P, Alward WL. Nocturnalarterial hypotension and its role in optic nerve headand ocular ischemic disor<strong>de</strong>rs. Am J Opthalmol. 1994;117(5):603-24.17. Hayreh SS. The 1994 Von Sallman Lecture. The optic nerve headcirculation in health and disease. Exp Eye Res. 1995; 61(3):259-72.18. Hayreh SS Acute ischemic disor<strong>de</strong>rs of the optic nerve. Pathogenesis,clinical manifestations, and management. OphthalmolClin North Am. 1996; 9:407-42.19. Luscher TF. The endothelium and cardiovascular disease – acomplex relation. N Engl J Med. 1994; 330(15):1081-3.20. Rodrigues LD, Silva MR, Schellini SA, Jorge EN. Picos <strong>de</strong>pressão intra-ocular: comparação entre curva tensional diária,minicurva e medida da pressão intra-ocular às 6h. Arq BrasOftalmol. 2004; 67(1):127-31.21. Liu JH, Kripke DF, Twa MD, Hoffman RE, Mansberger SL,Rex KM, et al. Twenty-four-hour pattern of intraocular pressurein the aging population. Invest Ophthalmol Vis Sci. 1999;40(12):2912-7.22. Tsukahara S, Sasaki T. Postural change of IOP in normal personsand in patients with primary wi<strong>de</strong> open-angle glaucoma andlow-tension glaucoma. Br J Ophthalmol. 1984; 68(6):389-92.23. Yamabayashi S, Aguilar RN, Hosoda M, Tsukahara S. Posturalchange of intraocular and blood pressures in ocular hypertensionand low tension glaucoma. Br J Ophthalmol. 1991;75(11):652-5.24. James CB, Smith SE. Pulsatile ocular blood flow in patients withlow tension glaucoma. Br J Ophthalmol. 1991; 75(8):466-70.25. Goldblum D, Mathis J, Böhnke M, Basset C, Hess CW, Gugger M,et al. [Nocturnal measurements of intraocular pressure in patientswith normal-tension glaucoma and sleep apnea syndrome].Klin Monatsbl Augenheilkd. 2000; 216(5):246-9. German.26. Kremmer S, Nie<strong>de</strong>rdraing N, Ayertey HD, Steuhl KP, Selbach JM.Obstructive sleep apnea syndrome, normal tension glaucoma,and nCPAP therapy - a short note. Sleep. 2003; 26(2):161-2.27. Davanger M, Ringvold A, Blika S. The probability of havingglaucoma at different IOP levels. Acta Ophthamol (Copenh).1991; 69(5):565-8.28. Asrani S, Zeimer R, Wilensky J, Gieser D, Vitale S, Lin<strong>de</strong>nmuthK. Large diurnal fluctuations in intraocular pressure are anin<strong>de</strong>pen<strong>de</strong>nt risk factor in patients with glaucoma. J Glaucoma.2000; 9(2):134-42.29. Gordon MO, Beiser JA, Brandt JD, Heuer DK, HigginbothamEJ, Johnson CA, et al. The Ocular Hypertension TreatmentStudy: baseline factors that predict the onset of primary openangleglaucoma. Arch Ophthalmol. 2002; 120(6):714-20.En<strong>de</strong>reço para correspondência:Faculda<strong>de</strong> <strong>de</strong> Medicina <strong>de</strong> Botucatu – UNESPDepartamento <strong>de</strong> <strong>Oftalmologia</strong>, Otorrinolaringologiae Cirurgia <strong>de</strong> Cabeça e PescoçoDistrito <strong>de</strong> Rubião Júnior s/nºCEP 18618-970 - Botucatu - SPTel/fax: (14) 3811-6256 / 3811-6081E-mail: rosabet@fmb.unesp.brRev Bras Oftalmol. 2009; 68 (6): 338-43


344RELATO DE CASOSíndrome do bloqueio capsular precoce relato<strong>de</strong> caso e especulação sobre o tamanhoda parte óptica da lente como fator <strong>de</strong> riscoEarly caspsular block syndrome a case report and speculationabout the size of the lens’ optic as a risk factorEduardo Ferrari Marback 1 , Rita <strong>de</strong> Cássia Aquino <strong>de</strong> Araújo 2 , Marcelo Siqueira <strong>de</strong> Freitas 3RESUMOApresentamos um caso <strong>de</strong> síndrome <strong>de</strong> bloqueio capsular precoce, tratado porreintervenção cirúrgica no segundo dia <strong>de</strong> pós-operatório. Comentamos as principaiscaracterísticas da síndrome, os possíveis fatores predisponentes, as opções <strong>de</strong> tratamentoe a importância do seu correto reconhecimento. Nós também especulamos sobreoutro possível fator <strong>de</strong> risco, lentes intraoculares com parte óptica <strong>de</strong> 6mm ou maiores.Descritores: Cápsula do cristalino; Cristalino/cirurgia; Extração da catarata/efeitosadversos; Pseudofacia/complicações; Relatos <strong>de</strong> casos1Doutor, Oftalmologista do Instituto <strong>de</strong> Olhos Freitas – Salvador (BA), Brasil;2Oftalmologista do Instituto <strong>de</strong> Olhos Freitas – Salvador (BA), Brasil;3Mestre, Diretor Médico do Instituto <strong>de</strong> Olhos Freitas – Salvador (BA), Brasil.Recebido para publicação em: 23/8/2009 - Aceito para publicação em 8/11/2009Rev Bras Oftalmol. 2009; 68 (6): 344-7


346Marback EF, Araújo RCA, Freitas MSFigura 1: A) Aspecto biomicroscópicono segundo dia pós-operatório, espaçoentre a parte óptica da lenteintraocular (seta cinza) e cápsula posterior(seta branca); B) Sete dias pósirrigação/aspiração para <strong>de</strong>sfazer o bloqueiocapsular, nota-se parte óptica dalente intraocular praticamente emcontacto direto com a cápsula posterior(seta)Figura 2: A) Mobilizando a lenteintraocular para <strong>de</strong>sfazer o bloqueio;B) Notar dobra <strong>de</strong> cápsula posterior(seta) indicando não haver maisdistensão do saco capsularmos dois viscoelásticos diferentes, um <strong>de</strong>les comhialuronato <strong>de</strong> sódio em sua composição.A forma precoce da síndrome po<strong>de</strong> acontecer porbloqueio mecânico pela simples aposição da óptica daLIO à capsulorrexe, ou ainda por uma a<strong>de</strong>rência inflamatóriaentre estas duas estruturas (3) . Em ambas situaçõescostuma haver um <strong>de</strong>slocamento anterior da LIOcom indução <strong>de</strong> <strong>de</strong>svio miópico que varia entre 2,0 a 3,0dioptrias (3-5) . Na forma inflamatória, o tratamento clínicoda causa <strong>de</strong> base costuma resolver o bloqueio (3) . Já aforma mecânica usualmente necessita <strong>de</strong> nova intervenção.Durak e colaboradores relatam resolução espontâneaem apenas 2 <strong>de</strong> 13 olhos após observação por 30dias, dos 11 olhos restantes em 8 foi tentada capsulotomiaanterior por YAG laser, com resolução em 5 olhos, 5 foramtratados por capsulotomia posterior e 1 pacienteoptou por não tratar por sentir-se confortável com a miopia(4) . Já Mar<strong>de</strong>lli propõe o tratamento precoce, realizadopor agulhamento na lâmpada <strong>de</strong> fenda (5) . Em nossocaso, optamos por levar novamente o paciente à sala<strong>de</strong> cirurgia e, após preparo <strong>de</strong> pele e saco conjuntivalcom iodopovidiona a 10% e 5% respectivamente, e corretoisolamento <strong>de</strong> anexos com campo a<strong>de</strong>sivo, abrimosa incisão principal e realizamos mobilização da LIO easpiração do líquido por <strong>de</strong>trás da mesma, com uma cânula<strong>de</strong> irrigação/aspiração manual. No sétimo DPO aAV era <strong>de</strong> 0,9 e houve um <strong>de</strong>svio positivo <strong>de</strong> aproximadamente2,5 dioptrias, como relata a literatura (1-5) . Nossaopção <strong>de</strong> reintervenção cirúrgica foi tomada pela necessida<strong>de</strong><strong>de</strong> restaurar a funcionalida<strong>de</strong> da visão <strong>de</strong> formarápida e efetiva. Questionamos o uso da capsulotomiaposterior por suas complicações potenciais como<strong>de</strong>scolamento <strong>de</strong> retina e e<strong>de</strong>ma cistói<strong>de</strong> <strong>de</strong> macular,bem como pela necessida<strong>de</strong> <strong>de</strong> i<strong>de</strong>almente postergar aresolução do problema por no mínimo 30 dias <strong>de</strong> pósoperatório,já o agulhamento em lâmpada <strong>de</strong> fenda nosparece um procedimento potencialmente <strong>de</strong>sconfortávelpara o paciente e cirurgião. Não sabemos qual o risco <strong>de</strong>endoftalmite ao reabrir a incisão principal da cirurgiaem ambiente <strong>de</strong> centro cirúrgico mesmo com todo o preparoe cuidados referentes a uma cirurgia intraocular.Em nosso serviço nos últimos 67 meses realizamos 4520facectomias e tivemos dois casos (0,044%) <strong>de</strong>endoftalmite (dados não publicados), extrapolando estataxa para a reabertura da incisão e irrigação/aspiraçãoda câmara anterior, acreditamos que o risco <strong>de</strong> infecçãoé bastante pequeno e o conforto para o paciente e controlepara o cirurgião são sem dúvida muito maiores.Em nosso caso, a LIO utilizada foi <strong>de</strong> acrílicohidrofílico, em peça única, com alças <strong>de</strong> <strong>de</strong>senho duplo eparte óptica <strong>de</strong> 6,25mm. Embora este tenha sido o únicocaso i<strong>de</strong>ntificado por nós em 106 cirurgias com esta LIO,é interessante notar que apesar <strong>de</strong> termos realizado aoredor <strong>de</strong> 4520 facectomias nos últimos 67 meses com aRev Bras Oftalmol. 2009; 68 (6): 344-7


Síndrome do bloqueio capsular precoce relato <strong>de</strong> caso e especulação sobre o tamanho da parte óptica da lente...347mesma técnica cirúrgica e LIOs <strong>de</strong> diferentes <strong>de</strong>senhose materiais, (6) este foi o primeiro caso diagnosticado pornós. Embora este dado não seja absoluto pois po<strong>de</strong>moster tomado algum caso prévio como erro biométrico,achamos que isto é improvável. O acrílico hidrofílico jáfoi aventado como possível fator <strong>de</strong> risco para o bloqueiocapsular precoce, embora existam casos relatadostambém com silicone, polimetilmetacrilato (PMMA) eacrílico hidrofóbico (2-4, 7-9) . No trabalho <strong>de</strong> Kim e colaboradoresfoi relatado associação entre implante <strong>de</strong> LIO<strong>de</strong> acrílico hidrofílico e síndrome <strong>de</strong> bloqueio capsular,e em 206 implantes <strong>de</strong> LIOS Akreos Adapt (BaushLomb) foram encontrados 6 casos (2,9%) <strong>de</strong> síndromedo bloqueio capsular precoce (3) . Nossa experiência pessoalcom este material ainda é limitada pois só começamosa utilizá-lo nos últimos 16 meses, neste período implantamos498 lentes <strong>de</strong> peça única do mesmo acrílicohidrofílico com óptica <strong>de</strong> 5,75 mm (Akreos Fit, BaushLomb), sem nunca ter visto um caso <strong>de</strong> bloqueio capsular.Vale ressaltar que apesar <strong>de</strong> serem do mesmo material,a Akreos adapt tem um <strong>de</strong>senho peculiar, com óptica <strong>de</strong>6 mm e quatro alças que potencialmente limitam amobilida<strong>de</strong> da LIO e a aspiração da substânciaviscoelástica atrás da LIO. Talvez mais importante queo material utilizado, seja a associação entre uma LIO <strong>de</strong>peça única sem angulação posterior <strong>de</strong> alças e, principalmente,uma parte óptica gran<strong>de</strong>. Quando individualizamosas LIOs nas diversas séries publicadas, é nítidoque a maioria dos casos aconteceram em olhos implantadoscom LIOs com pelo menos 6 mm <strong>de</strong> parteóptica (3-5) . Chamamos a atenção para a associação entreo implante <strong>de</strong> LIO com óptica gran<strong>de</strong> e capsulorrexepequena e bem centrada. Esta combinação tem se tornadocada vez mais frequente com a introdução das LIOsasféricas, tóricas e multifocais, que i<strong>de</strong>almente <strong>de</strong>vemficar no saco capsular com 360º <strong>de</strong> parte óptica cobertapela borda da capsulorrexe para manter a LIO bemcentrada, sendo nítida uma tendência à redução no diâmetroda capsulorrexe por gran<strong>de</strong> parte dos cirurgiões.É importante também chamar a atenção do cirurgiãopara o diagnóstico diferencial entre a síndrome <strong>de</strong>bloqueio capsular precoce e o erro biométrico. As soluçõespara estes dois problemas po<strong>de</strong>m ser antagônicas.Ou seja, um caso <strong>de</strong> síndrome <strong>de</strong> bloqueio capsular tomadopor erro biométrico po<strong>de</strong> levar a uma troca <strong>de</strong>LIO ou cirurgia refrativa corneana. A troca da LIO provavelmenteresolveria o bloqueio, mas levaria a insatisfaçãorefrativa com erro hipermetrópico. Já um procedimentorefrativo corneano não resolveria o bloqueiocapsular e também levaria a insatisfação refrativa comerro hipermetrópico, caso o bloqueio sofresse resoluçãoespontânea mais tardiamente ou após capsulotomia porcatarata secundária. Diante do exposto, sugerimos queem todo caso <strong>de</strong> suspeita <strong>de</strong> erro biométrico com <strong>de</strong>sviomiópico seja consi<strong>de</strong>rada a possibilida<strong>de</strong> <strong>de</strong> síndromedo bloqueio capsular precoce. Para realizar o diagnósticodiferencial entre as duas situações, sugerimos o estudocuidadoso da relação entre a lente e o saco capsular,sempre realizado sob midríase farmacológica.ABSTRACTWe present a case of early capsular block syndrome thatwas treated by re-operation on the second post operativeday. We discuss the major characteristics of the syndrome,possible predisposing factors, therapeutic options andhighlight the importance of its correct recognition. Wealso speculate about another possible risk factor, anintraocular lens with a optic part about 6mm or more.Keywords: Lens capsule; Lens/surgery; Cataractextraction/adverse effects; Pseudophakia/complications;Case reportsREFERÊNCIAS1. Davison JA. Capsular bag distension afterendophacoemulsification and posterior chamber intraocular lensimplantation. J Cataract Refract Surg. 1990; 16(1):99–108.2. Miyake K, Ota I, Ichihashi S, Miyake S, Tanaka Y, Terasaki H.New classification of capsular block syndrome. J CataractRefract Surg. 1998; 24(9):1230–4.3. Kim HK, Shin JP. Capsular block syndrome after cataractsurgery: clinical analysis and classification. J Cataract RefractSurg. 2008; 34(3):357–63.4. Durak I, Ozbek Z, Ferliel ST, Oner FH, Soylev M. Earlypostoperative capsular block syndrome. J Cataract RefractSurg. 2001; 27(4):555–9.5. Mar<strong>de</strong>lli PG. Slitlamp needle revision of capsular block syndrome.J Cataract Refract Surg. 2008; 34(7):1065–9.6. Marback EF. Resultados iniciais com a técnica <strong>de</strong>facoemulsificação por múltipla divisão circunferencial. RevBras Oftalmol. 2005;64:87-91.7. Masket S. Postoperative complications of capsulorhexis. JCataract Refract Surg. 1993; 19(6):721–4.8. Sugiura T, Miyauchi S, Eguchi S, Obata H, Nanba H, Fujino Y,et al. Analysis of liquid accumulated in the disten<strong>de</strong>d capsularbag in early postoperative capsular block syndrome. JCataract Refract Surg. 2000; 26(3):420–5.9. Mar<strong>de</strong>lli PG, Mehanna CJ. Phacoanaphylactic endophthalmitissecondary to capsular block syndrome. J Cataract RefractSurg. 2007; 33(5):921–2.En<strong>de</strong>reço para correspondência:Eduardo MarbackR. Jequié, n o 4 - Rio VermelhoCEP 41940-580 - Salvador - BahiaTel: (71) 3330-6100Fax: (71) 3330-6114Rev Bras Oftalmol. 2009; 68 (6): 344-7


348RELATO DE CASOHipertensão ocular “mascarada”por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarataOcular hipertension confoun<strong>de</strong>d bycorneal e<strong>de</strong>ma after cataract surgeryBruno <strong>de</strong> Freitas Valbon 1 , Fre<strong>de</strong>rico Guerra 2 , Renata Siqueira da Silva 3 , Ana Laura Canedo 4 , Renato Ambrósio Junior 5RESUMOCom base em mo<strong>de</strong>los matemáticos e estudos experimentais estima-se que as medidasda PIO sejam linearmente hiperestimadas em córneas com maior espessura e menorceratometria por meio <strong>de</strong> tonometria <strong>de</strong> aplanação <strong>de</strong> Goldmann (TAG). Entretanto,tal influência se dá <strong>de</strong> uma maneira mais complexa que a prevista por estes parâmetrosgeométricos, sendo diretamente relacionada com proprieda<strong>de</strong>s biomecânicas. O sistema<strong>de</strong> não contato ORA (Ocular response analyzer – Reichert) permite estudo dasproprieda<strong>de</strong>s biomecânicas juntamente com a medida pressórica calibrada para a TAGe a compensada da córnea. Adicionalmente, o estudo tomográfico com reconstruçãotridimensional do mapa paquimétrico caracteriza a córnea <strong>de</strong> forma mais completaque a ceratometria anterior e espessura central. Neste artigo, relatamos um caso <strong>de</strong> dorocular, fotofobia e baixa visão, 28 dias após cirurgia <strong>de</strong> facoemulsificação com implante<strong>de</strong> lente intraocular sem complicações em paciente feminina <strong>de</strong> 81 anos. Na primeiravisita da paciente, enquanto a TAG era <strong>de</strong> 16 mmHg, o valor da PIO compensada dacórnea (PIOcc), obtido com o ORA, era 25,6 mmHg. A histerese e fator <strong>de</strong> resistênciada córnea eram baixos, 4,1 e 6,1mmHg respectivamente, apesar da paquimetria centralser relativamente mais elevada, <strong>de</strong> 601 micra. O padrão <strong>de</strong> distribuição espacial daespessura era atenuado, compatível com e<strong>de</strong>ma corneano que era observado tambémpor meio das imagens <strong>de</strong> Scheimpflug (Pentacam). Com base nestes dados, foi feitodiagnóstico <strong>de</strong> quadro <strong>de</strong> uveíte hipertensiva, associado à e<strong>de</strong>ma corneano, instituindosetratamento tópico com combinação fixa <strong>de</strong> maleato <strong>de</strong> timolol e brimonidina associadoao acetato <strong>de</strong> prednisolona. Três semanas após, a paciente apresentou-se com gran<strong>de</strong>melhora da acuida<strong>de</strong> visual, resolução do e<strong>de</strong>ma corneano, e dos sintomas, normalizandoos parâmetros biomecânicos, geométricos da córnea e <strong>de</strong> PIO.Descritores: Proprieda<strong>de</strong>s biomecânicas; E<strong>de</strong>ma <strong>de</strong> córnea; Tomografia <strong>de</strong> córnea;Espessura corneana; Facoemulsificação; Relatos <strong>de</strong> casos1Pós-graduando (Mestrado) da Universida<strong>de</strong> Fe<strong>de</strong>ral Fluminense – UFF – Rio <strong>de</strong> Janeiro (RJ), Brasil;2Colaborador do Setor <strong>de</strong> Segmento Anterior do Instituto Benjamin Constant – Rio <strong>de</strong> Janeiro (RJ), Brasil;3Colaboradora do Setor <strong>de</strong> Glaucoma e Catarata do Hospital <strong>de</strong> Ipanema – Rio <strong>de</strong> Janeiro (RJ), Brasil;4Fellow <strong>de</strong> Refrativa do Instituto <strong>de</strong> Olhos Renato Ambrósio – Rio <strong>de</strong> Janeiro (RJ), Brasil;5Coor<strong>de</strong>nador do Grupo <strong>de</strong> Estudos <strong>de</strong> Tomografia e Biomecânica <strong>de</strong> Córnea do Rio <strong>de</strong> Janeiro - Brasil.Recebido para publicação em: 11/8/2009 - Aceito para publicação em 9/12/2009Rev Bras Oftalmol. 2009; 68 (6): 348-54


Hipertensão ocular “mascarada” por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata349INTRODUÇÃOAtonometria <strong>de</strong> aplanação por Goldmann (TAG),padrão ouro para a <strong>Oftalmologia</strong> é o método<strong>de</strong> aferição mais utilizado no mundo para medidada pressão intraocular (PIO), que se baseia no princípio<strong>de</strong> Imbert-Fick. Com isso, sofre influência <strong>de</strong> característicasda córnea, <strong>de</strong>stacando-se a espessura (1,3) . Demodo geral, assume-se que quanto mais fina seja a córnea,menor será sua resistência, causando uma menor medidada pressão, ou seja, valor hipoestimado. Por outro lado,quanto mais grossa a córnea, maior seria sua resistênciae maior a pressão medida, valor hiperestimado por meioda TAG. Além da espessura, outras características comoa curvatura da córnea, também são reconhecidamenteimportantes, <strong>de</strong> modo que córneas mais planas ten<strong>de</strong>m aapresentar maior resistência para a aplanação e gerarvalores mais elevados (4,5) . Entretanto, a medida da pressãointra-ocular sofre influência da córnea <strong>de</strong> forma maiscomplexa. Em um mo<strong>de</strong>lo matemático, Liu e Roberts 5 ,observaram uma maior influência <strong>de</strong> variações relacionadascom a tensão da superfície relacionadas pela resistênciada córnea (módulo <strong>de</strong> Young), potencialmente<strong>de</strong>terminando maior “erro” na TAG, comparando-se comos efeitos relacionados com a espessura central e com aceratometria.O estudo das proprieda<strong>de</strong>s biomecânicas dacórnea, tema <strong>de</strong> crescente interesse e objetivo <strong>de</strong> importantesestudos relacionados com córnea, glaucoma e cirurgiarefrativa, era limitado a mo<strong>de</strong>los matemáticos eestudos experimentais até a introdução do Ocularresponse analyzer (ORA – Reichert), em 2005 por Luce,PhD 6 . O ORA monitora dinamicamente a resposta <strong>de</strong>aplanamento da córnea pelo jato <strong>de</strong> ar, <strong>de</strong> modo a <strong>de</strong>terminarproprieda<strong>de</strong>s biomecânicas da córnea, juntamentecom as medidas da pressão intraocular. Além da medidada PIO calibrada <strong>de</strong> acordo com o “padrão ouro”,TAG (IOPg – gold standard, Goldmann correlatedIntraocular pressure), existe um cálculo para <strong>de</strong>terminaruma pressão compensada da córnea <strong>de</strong> acordo comas proprieda<strong>de</strong>s biomecânicas encontradas (IOPcc –corneal compensated Intraocular pressure). Além dasmedidas pressóricas, IOPg e IOPcc, o ORA <strong>de</strong>termina ahisterese corneana (CH – Corneal Hysteresis) que é umparâmetro relacionado com a visco-elasticida<strong>de</strong> dacórnea e o fator <strong>de</strong> resistência corneana (CRF – ornealresistance factor) (6-9) .De forma paralela ao progresso relacionadocom a caracterização das proprieda<strong>de</strong>s biomecânicasda córnea, o estudo tomográfico representa uma evoluçãona avaliação da geometria e arquitetura dacórnea (10-13) . A abordagem tomográfica possibilita reconstruçãodo mapa paquimétrico, com informaçõesda espessura corneana <strong>de</strong> limbo a limbo. Com isso, épossível i<strong>de</strong>ntificar o ponto central e <strong>de</strong>terminar seuvalor e localização. Consi<strong>de</strong>rando-se que a córnea sejaum menisco, mais fino na região central e mais espessona periferia, um método gráfico para <strong>de</strong>screver operfil <strong>de</strong> progressão paquimétrico foi proposto porAmbrósio, juntamente com o Grupo <strong>de</strong> Estudos <strong>de</strong>Tomografia e Biomecânica <strong>de</strong> Córnea do Rio <strong>de</strong> Janeiro(CTSP – Corneal Thickness Spatial Profile) emcolaboração com a Oculus (11,12) . Os gráficos foram incorporadosno programa <strong>de</strong> análise do Pentacam (12) .Com isso, foi possível caracterizar uma variaçãopopulacional normal Gaussiana na taxa <strong>de</strong> aumentoda espessura do ponto mais fino em direção a periferia.Adicionalmente, observamos diferenças significativasna distribuição espacial da paquimetria entrecórneas normais e com ectasia, que apresentam umpadrão mais acelerado <strong>de</strong> engrossamento do pontomais fino em direção a periferia, bem como entrecórneas normais e com e<strong>de</strong>ma, que apresentam umaatenuação no padrão <strong>de</strong> aumento da espessura (12) . Emoutras palavras, é possível com esta análise se diferenciaruma córnea fina normal <strong>de</strong> uma afinadaectásica e uma córnea grossa normal, <strong>de</strong> uma córneacom e<strong>de</strong>ma (13) .Neste artigo, relatamos um caso <strong>de</strong> uveítehipertensiva pós-cirurgia <strong>de</strong> catarata, realizada porfacoemulsificação e implante <strong>de</strong> lente intraocular (LIO)sem intercorrências. O quadro era mascarado por umamedida <strong>de</strong> TAG mais baixa por diminuição da resistênciada córnea por causa <strong>de</strong> e<strong>de</strong>ma leve (subclínico).Paradoxalmente, no caso <strong>de</strong> e<strong>de</strong>ma, apesar do aumentoda espessura, ocorre diminuição das proprieda<strong>de</strong>sbiomecânicas <strong>de</strong>vido à maior presença <strong>de</strong> água entre aslamelas <strong>de</strong> colágeno no estroma, que se comporta comouma esponja. Adicionalmente o e<strong>de</strong>ma era compatívelcom relativa transparência estromal, mas dificultava aavaliação do flare e <strong>de</strong> células na câmara interior. Estesfatores e características clínicas combinados tornam ocaso bastante peculiar e relevante como exemplo paraa importância da propedêutica com base na avaliaçãotomográfica e biomecânica da córnea.Relato <strong>de</strong> casoPaciente do sexo feminino, 81 anos, aposentada,natural do Rio <strong>de</strong> Janeiro, sem comorbida<strong>de</strong>s sistêmicasou oculares pré-existentes, foi encaminhada para segun-Rev Bras Oftalmol. 2009; 68 (6): 348-54


350Valbon BF, Fre<strong>de</strong>rico Guerra F, Silva RS, Canedo AL, Ambrósio Junior Rda opinião <strong>de</strong>vido a quadro <strong>de</strong> dor ocular, fotofobia e mávisão em olho esquerdo. A paciente havia realizado cirurgia<strong>de</strong> catarata há 28 dias sem sabidas intercorrênciascirúrgicas, estando em uso irregular <strong>de</strong> acetato <strong>de</strong>prednisolona (Predfort).Ao exame oftalmológico na primeira visita, realizadaem 28 <strong>de</strong> abril, a paciente apresentava acuida<strong>de</strong>visual corrigida <strong>de</strong> 20/20 em OD e 20/200 em OE, semmelhoras com refração manifesta. A TAG era <strong>de</strong> 14 e 16mmHg em OD e OE respectivamente, às 15 horas. Aoexame da lâmpada <strong>de</strong> fenda (biomicroscopia), observou-sesem alterações notáveis em OD, salvo cataratanuclear insipiente. Observou-se em OE:· pálpebras e anexos sem alterações; hiperemiaconjuntival leve, mais acentuada na região pericerática,sem secreções;· córnea transparente porém com aspecto <strong>de</strong>e<strong>de</strong>ma corneano leve e difuso 1+/4+, sem dobras <strong>de</strong>Descemet, ausência <strong>de</strong> lesões epiteliais coradas comfluoresceína e presença <strong>de</strong> ponto simples corneano presumidamente<strong>de</strong> mononylon 10-0 na região superior;· filme lacrimal espesso, com presença mo<strong>de</strong>rada<strong>de</strong> partículas, tempo <strong>de</strong> rotura do filme lacrimal comBUT menor que 10 segundos;· pupila fotorreagente provocando fotofobia mo<strong>de</strong>rada,<strong>de</strong>talhes da íris visíveis, mas discretamente nãonítidos, lente intraocular <strong>de</strong> câmara posterior em posiçãoa<strong>de</strong>quada;· vítreo limpo, sem opacida<strong>de</strong>s e polo posteriorsem alterações notáveis.Realizaram-se os exames <strong>de</strong> não contato e avaliaçãobiomecânica com sopro <strong>de</strong> ar (ORA) etomografia <strong>de</strong> córnea e segmento anterior por fotografiasScheimpflug rotacionais (Pentacam). O ORAem OE revelou IOPcc <strong>de</strong> 25,6mmHg, enquanto a IOPgfoi <strong>de</strong> 18,8mmHg. O CH e CRF foram <strong>de</strong> 4,1 e6,1mmHg respectivamente (Figura 1A). O exametomográfico revelou paquimetria central (Pentacam)<strong>de</strong> 591 micra (µm), com gráfico <strong>de</strong> progressão espacialapresentando padrão atenuado, compatível come<strong>de</strong>ma (Figura 2A). Por meio do estudo das imagens<strong>de</strong> Scheimpflug, observou-se aumento da refletivida<strong>de</strong>corneana, mais acentuadamente a nível epitelial queestromal, discreto e<strong>de</strong>ma estromal e LIO em posição(Figura 3A). O padrão <strong>de</strong> progressão paquimétricaespacial mostrou-se retificado, característico <strong>de</strong>e<strong>de</strong>ma leve (Figura 4A).Consi<strong>de</strong>rando os achados, foi feito o diagnóstico<strong>de</strong> uveíte anterior hipertensiva associado à e<strong>de</strong>ma apóscirurgia <strong>de</strong> catarata em OE, sendo prescrito colírio <strong>de</strong>Figura 1: Parâmetros e gráficos do ORA (Ocular responseanalyzer)Figura 2: Mapa diferencial paquimétricocombinação fixa <strong>de</strong> maleato <strong>de</strong> timolol associado àbrimonidina (Combigan), 2 vezes ao dia e acetato <strong>de</strong>prednisolona (Predfort) <strong>de</strong> 4/4 horas.A paciente retornou 1 semana após início do tratamento,relatando melhora parcial da dor e discretamelhora da visão, que era <strong>de</strong> 20/100 em OE. Ao examebiomicroscópico, observou-se ceratopatia ponteada noterço inferior da córnea, porém com redução importantedo quadro da hiperemia e redução leve do e<strong>de</strong>macorneano, permitindo observação <strong>de</strong> discreto flare nacâmara anterior. A paquimetria central (Pentacam) era<strong>de</strong> 587µm, ainda com padrão <strong>de</strong> atenuação da progressãoespacial (Figura 2B). A TAG foi 12mmHg (14h),IOPcc 12,9mmHg, IOPg 11,5mmHg, CH 9,0mmHg eRev Bras Oftalmol. 2009; 68 (6): 348-54


Hipertensão ocular “mascarada” por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata351CRF 8,0mmHg. Optou-se por manter medicação tópicaanti-hipertensiva ocular e iniciar <strong>de</strong>smame do corticói<strong>de</strong>com lotoprednol 0,5% (Loteprol), bem como adicionarlubrificação tópica com lágrima artificial a base <strong>de</strong> HPGuar e com Polyquad como conservante (Oftane) 4 vezesao dia e suplementação alimentar com ácidos graxosessenciais tipo ômega 3 a base <strong>de</strong> linhaça em cápsulas<strong>de</strong> 1g, 2 vezes ao dia durante as refeições.Três semanas após a primeira avaliação, a pacienteretornou relatando redução importante dos sintomas e melhorada visão que era, sem correção, <strong>de</strong> 20/20 em OE. Apaciente fazia uso da suplementação alimentar recomendada,Loteprol 2 vezes ao dia e Oftane irregularmente, tendo<strong>de</strong>scontinuado por conta própria o Combigan há 5 dias.O ORA revelou IOPcc 13,9 mmHg, IOPg 11,5mmHg, CH 9,2 e CRF 8,2 (Figura 1B). A espessura central(Pentacam) foi <strong>de</strong> 522µm (Figura 2C). A diferença daespessura corneana po<strong>de</strong> ser observada no mapa diferencial(Figura 2D). Observou-se redução significativa darefletivida<strong>de</strong> (scattering) da córnea e restauração da transparênciacorneana e resolução do quadro <strong>de</strong> e<strong>de</strong>maestromal, que se correlacionou com os achados das imagens<strong>de</strong> Scheimpflug (Figura 3B). O padrão <strong>de</strong> progressãoespacial estava <strong>de</strong>ntro dos limites da normalida<strong>de</strong>(Figura 4B). Ao exame da lâmpada <strong>de</strong> fenda, observou-seainda leve ceratopatia ponteada no 1/3 inferior.Consi<strong>de</strong>rando-se a evolução clínica e os achados,optamos por manter <strong>de</strong>smame do corticói<strong>de</strong>, orientara paciente sobre a importância da lubrificação e dasuplementação alimentar para tratamento da disfunçãolacrimal e retornar para controle pressórico em um mês.Com isso, a paciente retornou neste período semqueixas, em uso da suplementação alimentar recomendadae Oftane 4 vezes ao dia. A acuida<strong>de</strong> visual sem correçãoera <strong>de</strong> 20/20 em OE. O exame do segmento anteriorrevelava olho esquerdo calmo pseudofácico, sem alteraçõesnotáveis. A TAG era <strong>de</strong> 15mmHg às 15 horas. OORA revelou IOPcc 15,1mmHg, IOPg 13,3mmHg, CH9,3 e CRF 8,1. A espessura central (Pentacam) foi <strong>de</strong>529µm. O exame da microscopia especular revelou contagem<strong>de</strong> 2.617 células/mm 2 em OD, com mosaico celularnormal e 1.960 células em OE, com mo<strong>de</strong>radospolimegatismo e pleomorfismo. A paciente foi orientadapara retornar em 3 meses para controle clínico e acompanhamentoou antes, em caso <strong>de</strong> alguma sintoma novo.DISCUSSÃOA influência da córnea nas medidas da TAG ésabida <strong>de</strong>s<strong>de</strong> a introdução do método por Goldmann eFigura 3: Tomografia <strong>de</strong> segmento anterior com imagens <strong>de</strong>Scheimpflug (Pentacam)Figura 4: Gráfico <strong>de</strong> Progressão Paquimétrica Espacial: A – Naprimeira consulta com e<strong>de</strong>ma subclínico; B – Após o tratamentoSchimitd, em 1957 (1) . Entretanto, somente após a publicaçãodo estudo OHTS (Ocular Hypertension TreatmentStudy), em junho <strong>de</strong> 2002, que i<strong>de</strong>ntificou em análisemultivariada a espessura central da córnea (ECC) comoo mais importante fator preditivo para o <strong>de</strong>senvolvimento<strong>de</strong> lesão glaucomatosa do nervo óptico em pacienteshipertensos oculares, que houve a popularização do reconhecimento<strong>de</strong>sta variável (14) . Fórmulas <strong>de</strong> correçãoda TAG foram propostas com base em análises <strong>de</strong> regressãolinear com a ECC (15-18) . Entretanto, Gunvant etal. <strong>de</strong>monstraram que tais fórmulas po<strong>de</strong>m hipercorrigira medida da pressão em córneas finas (19) . Por outro lado,córneas com aumento da espessura por e<strong>de</strong>ma apresentamuma resistência reduzida e portanto um efeito naTAG similar a córneas com menor espessura (16-20) .Comisso, recomenda-se muito cuidado no uso <strong>de</strong> qualquerfórmula baseada em uma suposta relação sempre linearentre a espessura da córnea, sua resistência e seu efeitoRev Bras Oftalmol. 2009; 68 (6): 348-54


352Valbon BF, Fre<strong>de</strong>rico Guerra F, Silva RS, Canedo AL, Ambrósio Junior Rna TAG (5-9) . Adicionalmente, consi<strong>de</strong>rando-se os achados<strong>de</strong> Liu e Roberts, variações relacionadas com a tensãoda superfície referidas pela resistência da córnea(módulo <strong>de</strong> Young) potencialmente <strong>de</strong>terminam maiorimpacto na TAG, que a espessura central e aceratometria (5) .Com a introdução do ORA, iniciamos uma novafase no entendimento das proprieda<strong>de</strong>s biomecânicasda córnea (6) . Até então, o conhecimento nesta área eralimitado a estudos experimentais e mo<strong>de</strong>los matemáticos(8,21) . Fontes et al. reportaram as variações da CH eCRF em população brasileira normal, bem como suasrelações com diversos parâmetros clínicos (22) . A CH tevevalores médios <strong>de</strong> 10,17, com <strong>de</strong>svio-padrão <strong>de</strong> 1,82,enquanto o CRF médio foi <strong>de</strong> 10,14, com <strong>de</strong>svio-padrão<strong>de</strong> 1,8.Um recente artigo <strong>de</strong> <strong>de</strong>l Buey et al. <strong>de</strong>monstraque córneas com distrofia endotelial <strong>de</strong> Fuchs, com espessurasignificativamente maior (média <strong>de</strong> 606µm, com<strong>de</strong>svio-padrão <strong>de</strong> 20, variando entre 578-635µm), apresentammenores CH e CRF e maiores diferenças entreIOPcc que IOPg 23 . Adicionalmente, uma redução da CHe CRF foi encontrada após cirurgia da catarata, <strong>de</strong>vidoao e<strong>de</strong>ma pós-operatório (24-26) . Tal alteração se mostroutransitória, retornando aos patamares pré-operatóriosentre 1 e 3 meses (25,26) .A ECC po<strong>de</strong> ser medida por meio <strong>de</strong> sistema <strong>de</strong>ultrassom e óptico, não havendo diferenças significativasentre os métodos quando bem calibrados e realizadoscom metodologia correta (27) . A ECC varia <strong>de</strong>forma ampla na população normal, havendo algumasdiferenças em populações <strong>de</strong> diferentes regiões (22,28,29) .Por exemplo, na população norte-americana, o valormédio <strong>de</strong> ECC é <strong>de</strong> 556µm, com <strong>de</strong>svio-padrão <strong>de</strong> 35 (27)e na população brasileira, 545µm com <strong>de</strong>svio-padrão<strong>de</strong> 34 (22) , sendo que a variação foi semelhante emambas as populações, <strong>de</strong> 454 a 669µm. Existe, portanto,uma superposição <strong>de</strong> valores em córneas normais ecom e<strong>de</strong>ma por Distrofia <strong>de</strong> Fuchs (30) . Entretanto,e<strong>de</strong>ma po<strong>de</strong> ser i<strong>de</strong>ntificado com o padrão <strong>de</strong> atenuaçãoda progressão espacial da paquimetria, com menordiferença entre a região mais fina e a periferia dacórnea, o que é possível e facilitado pelos gráficos doPentacam, CTSP e PTI (12,13) .No presente caso relatado, observamos e<strong>de</strong>macorneano apesar da espessura central ser inferior a600µm. A retificação da progressão espacial dapaquimetria, juntamente com a maior refletivida<strong>de</strong> doestroma corneano e as medidas <strong>de</strong> CH e CRF maisbaixas que os valores normais possibilitam a i<strong>de</strong>ntificaçãoclínica <strong>de</strong> e<strong>de</strong>ma. A IOPcc foi fundamental parao diagnóstico <strong>de</strong> hipertensão ocular.Hipertensão ocular é uma complicação reconhecidaapós cirurgia <strong>de</strong> catarata, mesmo quando realizadasem complicações ou intercorrências per-operatórias(31,32) . A diminuição das proprieda<strong>de</strong>s biomecânicas dacórnea está relacionada à dificulda<strong>de</strong> na capacida<strong>de</strong> <strong>de</strong><strong>de</strong>tectar o aumento da PIO (24-26) . Uma forma alternativa<strong>de</strong> se <strong>de</strong>tectar tal aumento seria a tonometria <strong>de</strong> contornodinâmico (PASCAL), que sofre menor influência dascaracterísticas da córnea por não ser necessárioaplanação, mas apenas contato do sensor pressórico coma superfície (33-35) .Optamos pela associação <strong>de</strong> betabloqueadorcom alfa 2 agonista no tratamento da hipertensão ocularassociada à e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata,uma vez que era <strong>de</strong>sejada uma redução acentuadada PIO e tratar-se das melhores escolhas emtermos <strong>de</strong> medicações para o caso. Em casos <strong>de</strong> doençaendotelial, evitamos o uso <strong>de</strong> inibidor da anidrasecarbônica tópico pela possível atuação na funçãoendotelial, que po<strong>de</strong> causar ou agravar o e<strong>de</strong>ma (36-38) .Consi<strong>de</strong>rando o quadro clínico da paciente, acreditamosque a causa da hipertensão ocular estaria relacionadacom o processo inflamatório não controladoa<strong>de</strong>quadamente, sendo também contraindicado o uso<strong>de</strong> prostaglandinas ou <strong>de</strong>rivados. O tratamento da inflamaçãoa base <strong>de</strong> corticói<strong>de</strong> geralmente é muito eficaz,<strong>de</strong>vendo ser associado e ter o seu <strong>de</strong>smame bemcontrolado. Optamos por substituir o colírio <strong>de</strong> acetato<strong>de</strong> prednisolona por etabonato <strong>de</strong> lotoprednol para o<strong>de</strong>smame do corticói<strong>de</strong>, pois existe menor chance <strong>de</strong>hipertensão cortisônica (39) . O <strong>de</strong>senvolvimento <strong>de</strong> sinaise sintomas relacionados com a disfunção lacrimalpo<strong>de</strong> estar relacionado à presença <strong>de</strong> cloreto <strong>de</strong>benzalcônio como conservante nos colírios utilizados(40) . O tratamento com suplementação alimentar abase <strong>de</strong> ácidos graxos insaturados essenciais tipoômega 3 tem se mostrado eficaz em diversos estudos (41-43). O uso <strong>de</strong> colírio lubrificante a base <strong>de</strong> HP Guar éindicado no tratamento <strong>de</strong> disfunção lacrimal, principalmentese estiver relacionado com ceratopatia ponteada,bem como alterações da camada mucói<strong>de</strong> dofilme lacrimal (44-45) .Relatamos um caso <strong>de</strong> hipertensão ocular associadoà e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia <strong>de</strong> catarata emque a medida da pressão ocular por meio <strong>de</strong> TAGera hipoestimado. A documentação propedêutica com oORA e Pentacam para avaliação biomecânica etomográfica mostraram-se fundamentais para o diagnóstico,<strong>de</strong> modo a guiar o tratamento e acompanhamentoclínico do caso.Rev Bras Oftalmol. 2009; 68 (6): 348-54


Hipertensão ocular “mascarada” por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata353ABSTRACTGoldmann applanation tonometry (GAT) overestimatesintraocular pressure (IOP) measurements in cases with thickand flatter corneas. This is thought to occur linearly based onmathematical and on experimental studies. However, suchinfluence does exist, but this is more complex than the oneanticipated by pachymetry and keratometry because it isrelated to corneal biomechanical properties. The ocularresponse analyzer (ORA – Reichert) provi<strong>de</strong>s the datarelated to the biomechanical properties of the cornea alongwith the IOP measurements that are calibrated for correlatingto the Goldmann applanation and also compensated fromcorneal properties. Also corneal tomography with apachymetric map evaluation characterizes the corneabeyond central thickness and anterior curvature. In this article,we report a case of a 77 years old female patient with lowvision, photofobia and ocular pain 28 days afterphacoemulsification and intraocular lens implant. In the firstvisit, GAT was 14mmHg, while IOPcc (ORA cornealcompensated IOP) was 25,6mmHg. Corneal hysteresis andresistance factor were low: 4,1 and 6,1mmHg respectively<strong>de</strong>spite a central thickness of 601 micron. Corneal thicknessspatial profile was attenuated with an e<strong>de</strong>matous patternthat was also observed by the Scheimpflug images(Pentacam). Hypertensive uveitis was diagnosed and thepatient was started on a fixed combination of timolol andbrimonidine associate with prednisolone acetate. Three weeksafter, the patient referred resolution of photofobia and markedimprovement of vision. Clinically, e<strong>de</strong>ma was resolved asobserved by corneal tomographyc and biomechanicalfindings.Keywords: Biomechanical properties; Corneale<strong>de</strong>ma; Corneal tomography; Corneal thickness;Phacoemulsification; Case reportsREFERÊNCIAS1. Goldmann H, Schmidt T. [Applanation tonometry].Ophthalmologica. 1957;134(4):221-42. German.2. Doughty MJ, Zaman ML. Human corneal thickness and itsimpact on intraocular pressure measures: a review and metaanalysisapproach. Surv Ophthalmol. 2000;44(5):367-408.3. Dueker DK, Singh K, Lin SC, Fechtner RD, Minckler DS,Samples JR, Schuman JS. Corneal thickness measurement inthe management of primary open-angle glaucoma: a reportby the American Aca<strong>de</strong>my of Ophthalmology. Ophthalmology.2007;114(9):1779-87.4. Sánchez-Tocino H, Bringas-Calvo R, Iglesias-Cortiñas D. [Correlationbetween intraocular pressure, paquimetry andkeratometry in a normal population]. Arch Soc Esp Oftalmol.2007;82(5):267-72. Spanish.5. Liu J, Roberts CJ. Influence of corneal biomechanical propertieson intraocular pressure measurement: quantitative analysis.J Cataract Refract Surg. 2005;31(1):146-55. Comment in:J Cataract Refract Surg. 2006;32(7):1073-4; author reply 1074.6. Luce DA. Determining in vivo biomechanical properties ofthe cornea with an ocular response analyzer. J Cataract RefractSurg. 2005;31:156-62.7. Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-HeathDF. Corneal thickness- and age-related biomechanical propertiesof the cornea measured with the ocular response analyzer.Invest Ophthalmol Vis Sci. 2006;47(12):5337-47.8. Alonso RS, Ventura MP, Ambrósio Jr R. Aspectos práticos daavaliação biomecânica da córnea. In: Vieira Netto M,Ambrósio Júnior R, Schor P, Chalita MR, Chamon W, editores.Wavefront, topografia e tomografia da córnea e segmentoanterior: atualização propedêutica em cirurgia refrativa. Rio<strong>de</strong> Janeiro: Cultura Médica; 2006.9. Pepose JS, Feigenbaum SK, Qazi MA, San<strong>de</strong>rson JP, RobertsCJ. Changes in corneal biomechanics and intraocular pressurefollowing LASIK using static, dynamic, and noncontacttonometry. Am J Ophthalmol. 2007;143(1):39-47.10. Souza MB, Me<strong>de</strong>iros FM, Ruiz-Alves M. Conceitos emtomografia do segmento anterior. In: Vieira Netto M, AmbrósioJúnior R, Schor P, Chalita MR, Chamon W, editores. Wavefront,topografia e tomografia da córnea e segmento anterior:atualização propedêutica em cirurgia refrativa. Rio <strong>de</strong> Janeiro:Cultura Médica; 2006.11. Luz A, Ursulio M, Castañeda D, Ambrósio Jr. R. Progressãoda espessura corneana do ponto mais fino em direção aolimbo: estudo <strong>de</strong> uma população normal e <strong>de</strong> portadores <strong>de</strong>ceratocone para criação <strong>de</strong> valores <strong>de</strong> referência. Arq BrasOftalmol. 2006;69(4):579-83.12. Ambrósio R Jr, Alonso RS, Luz A, Coca Velar<strong>de</strong> LG. Cornealthicknessspatial profile and corneal-volume distribution: tomographicindices to <strong>de</strong>tect keratoconus. J Cataract RefractSurg. 2006;32(11):1851-9.13. Ambrósio Jr R. Enhanced Screening for Refractive CandidatesBased on Corneal Tomography and Biomechanics.ASCRS 2008 Online Poster - awar<strong>de</strong>d as Best Poster Category:Cornea. [cited 2009 Jun 11]. Available from: http://ascrs2008.abstractsnet.com/acover.wcs?entryid=000116)14. Gordon MO, Beiser JA, Brandt JD, Heuer DK, HigginbothamEJ, Johnson CA, et al. The Ocular Hypertension TreatmentStudy: baseline factors that predict the onset of primary openangleglaucoma. Arch Ophthalmol. 2002;120(6):714-20; discussion829-30. Comment in: Arch Ophthalmol.2004;122(7):1088-9; author reply 1089.15. Ehlers N, Bramsen T, Sperling S. Applanation tonometry andcentral corneal thickness. Acta Ophthalmol (Copenh).1975;53(1):34-43.16. Whitacre MM, Stein R. Sources of error with use of Goldmanntypetonometers. Surv Ophthalmol. 1993;38(1):1-30.17. Orssengo GJ, Pye DC. Determination of the true intraocularpressure and modulus of elasticity of the human cornea invivo. Bull Math Biol. 1999;61(3):551-72.18. Shah S, Chatterjee A, Mathai M, Kelly SP, Kwartz J, HensonD, McLeod D. Relationship between corneal thickness andmeasured intraocular pressure in a general ophthalmologyclinic. Ophthalmology. 1999;106(11):2154-60. Comment in:Ophthalmology. 2000;107(10):1803. Ophthalmology.2001;108(8):1364-6.19. Gunvant P, O’Leary DJ, Baskaran M, Broadway DC, WatkinsRJ, Vijaya L. Evaluation of tonometric correction factors. JGlaucoma. 2005;14(5):337-43.Rev Bras Oftalmol. 2009; 68 (6): 348-54


354Valbon BF, Fre<strong>de</strong>rico Guerra F, Silva RS, Canedo AL, Ambrósio Junior R20. Simon G, Small RH, Ren Q, Parel JM. Effect of corneal hydrationon Goldmann applanation tonometry and cornealtopography. Refract Corneal Surg. 1993;9(2):110-7.21. Roberts C. Biomechanical customization: the next generationof laser refractive surgery. J Cataract Refract Surg.2005;31(1):2-5.22. Fontes BM, Ambrósio R Jr, Alonso RS, Jardim D, Velar<strong>de</strong> GC,Nosé W. Corneal biomechanical metrics in eyes with refractionof -19.00 to +9.00 D in healthy Brazilian patients. JRefract Surg. 2008;24(9):941-5.23. <strong>de</strong>l Buey MA, Cristóbal JA, Ascaso FJ, Lavilla L, LancharesE. Biomechanical properties of the cornea in Fuchs’ cornealdystrophy. Invest Ophthalmol Vis Sci. 2009;50(7):3199-202.24. Hager A, Loge K, Füllhas MO, Schroe<strong>de</strong>r B, Grossherr M,Wiegand W. Changes in corneal hysteresis after clear cornealcataract surgery. Am J Ophthalmol. 2007;144(3):341-6.25. Kucumen RB, Yenerel NM, Gorgun E, Kulacoglu DN, OncelB, Kohen MC, Alimgil ML. Corneal biomechanical propertiesand intraocular pressure changes after phacoemulsificationand intraocular lens implantation. J Cataract Refract Surg.2008;34(12):2096-8.26. Valbon B, Ventura MP, Salomão M, Ambrósio R Jr. Correlationbetween central corneal thickness and biomechanicalproperties after phacoemulsification. Invest Ophthalmol VisSci. 2008;49:E-Abstract 656.27. Alonso RS, Maranhão SB, Luz A, Castañeda DN, AmbrósioJúnior R. Comparação entre as medidas da espessura corneanacentral obtidas pela paquimetria ultrassônica e pelo sistemaPentacam. Rev Bras Oftalmol. 2005;64(4):227-31.28. Ambrósio R Jr, Klyce SD, Wilson SE. Corneal topographicand pachymetric screening of keratorefractive patients. JRefract Surg. 2003;19(1):24-9.29. Aghaian E, Choe JE, Lin S, Stamper RL. Central cornealthickness of Caucasians, Chinese, Hispanics, Filipinos, AfricanAmericans, and Japanese in a glaucoma clinic. Ophthalmology.2004;111(12):2211-9.30. Ambrósio R Jr, Netto MV, Wilson SE. Surgery in patients withFuchs’. Ophthalmology. 2006;113(3):503; author reply 504.31. Alves MC, Faria RM, Raskin E, Raskin DG, Eredia GC,Andra<strong>de</strong> BBA. Hipertensão intra-ocular apósfacoemulsificação e implante <strong>de</strong> lente intra-ocular. Rev BrasOftalmol. 2001;60(6):432-6.32. Dayanir V, Ozcura F, Kir E, Topaloðlu A, Ozkan SB, Aktunç T.Medical control of intraocular pressure after phacoemulsification.J Cataract Refract Surg. 2005;31(3):484-8.33. Pepose JS, Feigenbaum SK, Qazi MA, San<strong>de</strong>rson JP, RobertsCJ. Changes in corneal biomechanics and intraocular pressurefollowing LASIK using static, dynamic, and noncontacttonometry. Am J Ophthalmol. 2007;143(1):39-47.34. Hager A, Loge K, Schroe<strong>de</strong>r B, Füllhas MO, Wiegand W. Effectof central corneal thickness and corneal hysteresis ontonometry as measured by dynamic contour tonometry, ocularresponse analyzer, and Goldmann tonometry in glaucomatouseyes. J Glaucoma. 2008;17(5):361-5. Erratum in: JGlaucoma. 2008;17(7):604. Annette, Hager [corrected toHager, Annette]; Kristina, Loge [corrected to Loge, Kristina];Bernd, Schroe<strong>de</strong>r [corrected to Schroe<strong>de</strong>r, Bernd]; Mark-Oliver, Füllhas [corrected to Füllhas, Mark-Oliver]; Wolfgang,Wiegand [corrected to Wiegand, Wolfgang].35. Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E. Dynamiccontour tonometry in comparison to intracameral IOP measurements.Invest Ophthalmol Vis Sci. 2008;49(6):2472-7.36. Wirtitsch MG, Findl O, Heinzl H, Drexler W. Effect ofdorzolami<strong>de</strong> hydrochlori<strong>de</strong> on central corneal thickness inhumans with cornea guttata. Arch Ophthalmol.2007;125(10):1345-50.37. Zhao JC, Chen T. Brinzolami<strong>de</strong> induced reversible corneal<strong>de</strong>compensation. Br J Ophthalmol. 2005;89(3):389-90.38. Adamsons I. Irreversible corneal <strong>de</strong>compensation in patientstreated with topical dorzolami<strong>de</strong>. Am J Ophthalmol.1999;128(6):774-6.39. Bartlett JD, Horwitz B, Laibovitz R, Howes JF. Intraocularpressure response to loteprednol etabonate in known steroidrespon<strong>de</strong>rs. J Ocul Pharmacol. 1993;9(2):157-65.40. Leung EW, Me<strong>de</strong>iros FA, Weinreb RN. Prevalence of ocularsurface disease in glaucoma patients. J Glaucoma.2008;17(5):350-5.41. Ambrósio RJ, Stelzner SK, Boerner CF, Honan PR, McIntyreDJ. Nutrition and dry eye: the role of lipids. Rev RefractSurg. 2002:29-32.42. Pinheiro Jr. MN, Santos PM, Santos RCR, Barros JN, PassosLF, Cardoso Neto JC. Uso oral do óleo <strong>de</strong> linhaça(Linumusitatissimum) no tratamento do olho seco <strong>de</strong> pacientesportadores da síndrome <strong>de</strong> Sjögren. Arq Bras Oftalmol.2007;70(4):649-55.43. Macsai MS. The role of omega-3 dietary supplementation inblepharitis and meibomian gland dysfunction (an AOS thesis).Trans Am Ophthalmol Soc. 2008;106:336-56.44. Gifford P, Evans BJ, Morris J. A clinical evaluation of Systane.Cont Lens Anterior Eye. 2006;29(1):31-40.45. Rolando M, Autori S, Badino F, Barabino S. Protecting theocular surface and improving the quality of life of dry eyepatients: a study of the efficacy of an HP-guar containingocular lubricant in a population of dry eye patients. J OculPharmacol Ther. 2009;25(3):271-8.En<strong>de</strong>reço para correspondênciaRenato Ambrósio Jr.Rua Con<strong>de</strong> <strong>de</strong> Bonfim, nº 211/712 – TijucaCEP 20520-050 – Rio <strong>de</strong> Janeiro - RJTel: (21) 2274-5694e-mail: renatoambrosiojr@wavefront.com.brRev Bras Oftalmol. 2009; 68 (6): 348-54


RELATO DE CASO355Imunoterapia tópica no tratamentodo carcinoma basocelular periocularTopical immunotherapy for the treatmentof periocular basal cell carcinomaErick Marcet Santiago <strong>de</strong> Macedo 1 , Rachel Camargo Carneiro 1 , Suzana Matayoshi 2RESUMOOs autores <strong>de</strong>screvem um paciente com carcinoma basocelular nodular em canto medialtratado com imiquimo<strong>de</strong> creme 5%. A avaliação patológica <strong>de</strong> uma biópsia incisionalrealizada 12 semanas após o tratamento revelou a total resolução da lesão. Embora acirurgia permaneça como tratamento <strong>de</strong> primeira escolha, a imunoterapia comimiquimo<strong>de</strong> creme 5% surge como uma opção terapêutica válida para o tratamentoambulatorial do carcinoma basocelular periocular.Descritores: Carcinoma basocelular; Antineoplásicos; Imunoterapia; Neoplasiaspalpebrais; Biópsia; Relatos <strong>de</strong> casos1Pós-graduandos (Doutorado) do Setor <strong>de</strong> Plástica Ocular da Clínica Oftalmológica do Hospital das Clínicas da Faculda<strong>de</strong> <strong>de</strong>Medicina da Universida<strong>de</strong> <strong>de</strong> São Paulo – USP – São Paulo - SP - Brasil;2Doutora, Médica Assistente e Chefe do Setor <strong>de</strong> Plástica Ocular da Clínica Oftalmológica do Hospital das Clínicas da Faculda<strong>de</strong> <strong>de</strong>Medicina da Universida<strong>de</strong> <strong>de</strong> São Paulo – USP – São Paulo - SP - Brasil;Trabalho realizado no Setor <strong>de</strong> Plástica Ocular da Clínica Oftalmológica do Hospital das Clínicas da Faculda<strong>de</strong> <strong>de</strong> Medicina daUniversida<strong>de</strong> <strong>de</strong> São Paulo – USP – São Paulo - SP - BrasilApoio CNPq - Processo CNPq nº480144/2008-7Recebido para publicação em: 24/7/2009 - Aceito para publicação em 5/11/2009Rev Bras Oftalmol. 2009; 68 (6): 355-8


356Macedo EMS, Carneiro RC, Matayoshi S,INTRODUÇÃOAneoplasia mais comum da região periocular éo carcinoma basocelular. Esse tumor <strong>de</strong> crescimentolento tem sua origem na epi<strong>de</strong>rme epo<strong>de</strong> causar <strong>de</strong>struição significativa dos tecidos locais,porém raramente leva a metástase (1-2) . Entre as causasque predispõe ao início <strong>de</strong>sta transformação celular temosa exposição prolongada e repetida à radiação ultravioleta,predisposição genética, além da exposição acarcinógenos (1) .A intervenção terapêutica é orientada para completaerradicação das células malignas e os tratamentosina<strong>de</strong>quados levam a recorrência. Na área periocularencontramos dificulda<strong>de</strong>s <strong>de</strong> intervenção, uma vez quea terapia escolhida <strong>de</strong>ve atingir essa meta com a máximapreservação da função palpebral e o melhor resultadoestético possível.Atualmente visando alcançar esses objetivos algumasterapias conservadoras têm sido pesquisadas. Apósuma ampla revisão bibiliográfica, observou-se que oimiquimo<strong>de</strong> creme 5% apresenta os requisitos necessáriospara o uso em lesões perioculares (1) . Oimunomodulador já tem seu <strong>de</strong>staque no uso<strong>de</strong>rmatológico, observando-se uma cura histológica nagran<strong>de</strong> maioria dos casos <strong>de</strong> carcinoma basocelular (2-3) .Relato <strong>de</strong> casoPaciente masculino, 57 anos, Fitzpatrick tipo II,apresentando lesão nódulo-ulcerativa em canto medial<strong>de</strong> olho esquerdo há aproximadamente sete anos <strong>de</strong> crescimentolento, acompanhada <strong>de</strong> episódios <strong>de</strong>sangramento. A lesão media aproximadamente 10 mmem seu maior diâmetro (Figura 1A).Foi realizada biópsia incisional com punch <strong>de</strong> 2mm escolhendo o local mais típico do tumor. O materialcoletado foi encaminhado para o <strong>de</strong>partamento <strong>de</strong> patologiado próprio hospital, <strong>de</strong>vidamente i<strong>de</strong>ntificado emrecipiente com Formol 10% para avaliação patológica.O exame revelou a presença <strong>de</strong> carcinoma basocelularnodular pela coloração <strong>de</strong> hematoxilina e eosina (HE).Apresentava o aspecto típico do ninho <strong>de</strong> célulasneoplásicas com paliçada periférica e retração doestroma adjacente (Figura 1B).O paciente foi orientado verbalmente e atravésdo termo <strong>de</strong> consentimento livre esclarecido sobre asopções terapêuticas e optou-se pelo tratamento conservadorpor motivos estéticos e pela possibilida<strong>de</strong> <strong>de</strong> complicaçõespós-operatórias como epífora, <strong>de</strong>vido a sualocalização.Figura 1: A – Lesão nódulo-ulcerativa em canto medial <strong>de</strong> olhoesquerdo antes do tratamento; B – ninho <strong>de</strong> células neoplásicascom paliçada periférica (seta 1) e retração do estroma adjacente(seta 2)HE 200xImiquimo<strong>de</strong> creme 5% foi aplicado com cotonetepor acompanhante após treinamento médico conformeposologia <strong>de</strong> uma vez ao dia, cinco vezes por semana, por16 semanas. Foi orientado a utilizar gel lubrificante emfórnice conjuntival antes da aplicação da medicação ecolírio lubrificante <strong>de</strong> seis em seis horas, durante o período<strong>de</strong> vigília. O acompanhamento oftalmológico foi quinzenale o paciente referiu vários episódios <strong>de</strong> contato aci-Rev Bras Oftalmol. 2009; 68 (6): 355-8


Imunoterapia tópica no tratamento do carcinoma basocelular periocular357durante uma semana. Na décima segunda semana apóso término do tratamento, foi submetido a nova biópsiaincisional para controle <strong>de</strong> cura. Não há sinais <strong>de</strong> recidivaapós doze meses <strong>de</strong> seguimento (Figura 2A).O resultado anátomo-patológico revelouparaqueratose <strong>de</strong> epitélio malpighiano e infiltradolinfoplasmocitário mo<strong>de</strong>rado em <strong>de</strong>rme superficialcom ausência <strong>de</strong> neoplasia no tecido examinado (Figura2B).DISCUSSÃOFigura 2: A – Aspecto clínico um ano após o tratamento (semsinais <strong>de</strong> recorrência); B – Fragmento <strong>de</strong> pele apresentandoparaqueratose <strong>de</strong> epitélio malpighiano e infiltradolinfoplasmocitário mo<strong>de</strong>rado em <strong>de</strong>rme superficial (seta); Biópsia12 semanas após término do tratamento – corado pela HE, 200X<strong>de</strong>ntal com a conjuntiva. No <strong>de</strong>correr do tratamento apresentouconjuntivite reacional e ceratite puntata leve queregrediu após interrupção da medicação.Após quinta semana <strong>de</strong> tratamento, o pacienterelatou episódio <strong>de</strong> secreção ocular purulenta. Ao exameoftalmológico sob biomicroscopia, observou-se a presença<strong>de</strong> papilas em conjuntiva tarsal, sendo prescritocolírio <strong>de</strong> tobramicina uma gota <strong>de</strong> seis em seis horasO uso tópico do imiquimo<strong>de</strong> 5% em creme parao tratamento <strong>de</strong> carcinomas basocelulares têm-se mostradoeficaz. Esse imunomodulador se sobrepõe emrelação a outras terapias conservadoras como ointerferon e as interleucinas intralesionais (1) . Ao contrárioda maioria dos imunomoduladores que têm afunção <strong>de</strong> inibir a resposta imune, o imiquimo<strong>de</strong> promovesua ativação. Sua principal ação consiste na liberação<strong>de</strong> Th1 citoquinas, promovendo a inflamaçãolocal da pele. Os antígenos tumorais passam a ser reconhecidospelas células <strong>de</strong>ndríticas da pele,internalizados e então apresentados aos linfócitos Tcitotóxicos que migram <strong>de</strong> volta para a pele, levandoà <strong>de</strong>struição das células tumorais. Uma ação secundáriaobservada foi a indução direta da apoptose dascélulas tumorais pelo imiquimo<strong>de</strong>, que parece ser capaz<strong>de</strong> ativar a via das caspases (1) .Liberado para uso em CBC superficial e ceratoseactínica em 2004 pelo “US Food and DrugAdministration “ (FDA - U.S.A) (3-5) e em 2006 pela AgênciaNacional <strong>de</strong> Vigilância Sanitária (Anvisa) aindapermanece em estudo para aplicação no CBC nodular,assim como na área periocular (4,6,7) . O CBC nodular assimcomo o superficial são subtipos histológicos menosagressivos do CBC (2) e aparentemente mais responsivosa essa medicação. Os poucos trabalhos realizados na áreaperiocular foram promissores, po<strong>de</strong>ndo se tornar umaalternativa interessante para casos em que o pacienterecusa a intervenção cirúrgica seja por motivo estéticoou por contra-indicação clínica (1-4-6-7) .Os pacientes portadores <strong>de</strong> xero<strong>de</strong>rma pigmentar (8)e Síndrome Gorlin-goltz (9) em que são necessárias múltiplascirurgias, muitas das vezes <strong>de</strong>sfigurantes, também po<strong>de</strong>rãose beneficiar da medicação.A ceratite puntata e a conjuntivite reacional foramos principais efeitos colaterais observados e coinci<strong>de</strong>mcom os da literatura (4-6) . No presente caso umaconjuntivite bacteriana se sobrepôs à conjuntiviteRev Bras Oftalmol. 2009; 68 (6): 355-8


358Macedo EMS, Carneiro RC, Matayoshi S,reacional, <strong>de</strong>monstrando a importância do acompanhamentooftalmológico rigoroso no tratamento empregado.Estudos atualmente em curso avaliarão suaaplicabilida<strong>de</strong> na região periocular. Até o presente momentonão se evi<strong>de</strong>nciou nenhum dano ocular permanente(4-6-7) . Todas as alterações oculares apresentadas naliteratura (4-6) e no caso relatado foram temporárias eregrediram após interrupção do tratamento ou prescrição<strong>de</strong> colírios.ABSTRACTThe authors <strong>de</strong>scribe a patient with a medial canthalnodular basal cell carcinoma treated with Imiquimod 5%cream. Pathologic evaluation of an incisional biopsyperformed 12 weeks after treatment revealed completeresolution of local disease. Although the treatment ofchoice continues to be surgery, topical immunotherapywith imiquimod 5% cream is an emerging therapeuticoption suitable for the outpatient treatment of periocularbasal cell carcinoma.Keywords: Carcinoma, basal cell; Antineoplasticagents; Immunotherapy; Eyelid neoplasms ; Biopsy; CasereportsREFERÊNCIAS1. Macedo EMS, Carneiro RC, Matayoshi S. <strong>Nov</strong>a modalida<strong>de</strong>no tratamento do carcinoma basocelular periocular:imiquimo<strong>de</strong>: [revisão]. Rev Bras Oftalmol. 2007;66(6):411-7.2. Festa Neto C. Tratamento tópico do carcinoma basocelularsuperficial e nodular pelo imiquimod creme a 5 por cento:observação <strong>de</strong> 10 casos. An Bras Dermatol. 2002;77(6):693-8.3. Schulze HJ, Cribier B, Requena L, Reifenberger J, FerrándizC, Garcia Diez A, et al. Imiquimod 5% cream for the treatmentof superficial basal cell carcinoma: results from a randomizedvehicle-controlled phase III study in Europe. Br JDermatol. 2005;152(5):939-47.4. Choontanom R, Thanos S, Busse H, Stupp T. Treatment ofbasal cell carcinoma of the eyelids with 5% topical imiquimod:a 3-year follow-up study. Graefes Arch Clin Exp Ophthalmol.2007;245(8):1217-20.5. Geisse J, Caro I, Lindholm J, Golitz L, Stampone P, Owens M.Imiquimod 5% cream for the treatment of superficial basal cellcarcinoma: results from two phase III, randomized, vehicle-controlledstudies. J Am Acad Dermatol. 2004;50(5):722-33.6. Blasi MA, Giammaria D, Balestrazzi E. Immunotherapy withimiquimod 5% cream for eyelid nodular basal cell carcinoma.Am J Ophthalmol. 2005;140(6):1136-9.7. Leppälä J, Kaarniranta K, Uusitalo H, Kontkanen M.Imiquimod in the treatment of eyelid basal cell carcinoma.Acta Ophthalmol Scand. 2007;85(5):566-8.8. Roseeuw D. The treatment of basal skin carcinomas in twosisters with xero<strong>de</strong>rma pigmentosum. Clin Exp Dermatol.2003;28 Suppl 1:30-2.9. Micali G, Lacarrubba F, Nasca MR, De Pasquale R. The useof imiquimod 5% cream for the treatment of basal cell carcinomaas observed in Gorlin’s syndrome. Clin Exp Dermatol.2003;28 Suppl 1:19-23En<strong>de</strong>reço para correspondência:Dr. Erick Marcet Santiago <strong>de</strong> MacedoAv. Higienópolis, nº 870 apto. 63 – HigienópolisCEP 01242-001 - São Paulo - SPe-mail: erickmarcet@yahoo.com.brRev Bras Oftalmol. 2009; 68 (6): 355-8


ARTIGO DE REVISÃO 359“Crosslinking”<strong>de</strong> colágenono tratamento do ceratoconeCollagen crosslinking for the treatment of keratoconousRodrigo Coelho Amaral 1 , Helena Parente Solari 2RESUMOEm meados da década <strong>de</strong> 90, o crosslinking <strong>de</strong> colágeno corneano foto-induzido utilizandoriboflavina foi proposto como uma nova modalida<strong>de</strong> terapêutica no tratamentodo ceratocone. Des<strong>de</strong> então foram estudados os efeitos <strong>de</strong>ste procedimento em ambientelaboratorial e posteriormente em ensaios clínicos. Neste artigo, revisamos a literaturaque já foi publicada até o momento no intuito <strong>de</strong> expor sobre o procedimento e seusefeitos.Descritores: Ceratocone/terapia; Colágeno/efeitos <strong>de</strong> radiação; Riboflavina/usoterapêutico; Terapia ultravioleta; Fototerapia; Raios ultravioleta; Reagentes para ligaçõescruzadas1Resi<strong>de</strong>nte (R3) <strong>de</strong> <strong>Oftalmologia</strong> do Hospital dos Servidores do Estado do Rio <strong>de</strong> Janeiro – HSE - Rio <strong>de</strong> Janeiro (RJ), Brasil;2Pós-Doutora em Patologia Ocular na Universida<strong>de</strong> McGill em Montreal, Canadá; Professora adjunto da Universida<strong>de</strong> Fe<strong>de</strong>ralFluminense – UFF – Rio <strong>de</strong> Janeiro - (RJ), Brasil.Recebido para publicação em: 19/11/2009 - Aceito para publicação em 16/12/2009Rev Bras Oftalmol. 2009; 68 (6): 359-64


360Amaral RC, Solari HPINTRODUÇÃOI<strong>de</strong>alizado por Seiler et al. (1) , o uso <strong>de</strong> irradiaçãoultravioleta A (UVA) associada à riboflavina (vitaminaB2) para indução <strong>de</strong> crosslinking <strong>de</strong> colágenoda córnea apresenta-se como uma técnica promissora,que vem sendo amplamente divulgada através das experiênciasclínicas <strong>de</strong> pesquisadores do mundo inteiro.Este estudo tem como objetivo avaliar os resultadosda utilização do crosslinking no tratamento doceratocone, revisando os dados publicados <strong>de</strong> estudos invitro e <strong>de</strong> estudos clínicos.Princípio bioquímico e molecularO colágeno representa o principal elemento presentena matriz extracelular (MEC) humana, estandoenvolvido principalmente em processos <strong>de</strong> renovação ecicatrização tissular. É um polímero proteico natural, sintetizadoa partir dos fibroblastos e formado porpolipeptídios organizados em ca<strong>de</strong>ias (2,3) .A reticulação polimérica é um processo on<strong>de</strong> ca<strong>de</strong>iaspoliméricas são interligadas por pontes <strong>de</strong> ligaçõesformando uma re<strong>de</strong> polimérica tridimensional, processotambém conhecido como crosslinking (formação <strong>de</strong> ligaçõescruzadas). Como resultado da reticulação, as estruturasten<strong>de</strong>m a per<strong>de</strong>r sua flui<strong>de</strong>z e tornam-se mais rígidas (4,5) .O conhecimento da capacida<strong>de</strong> <strong>de</strong> reação dasmoléculas <strong>de</strong> colágeno com produtos provenientes <strong>de</strong>seu ambiente (reticulação) levou Dalle Carbonare ePathak a testarem a sensibilida<strong>de</strong> do colágeno frente àassociação <strong>de</strong> riboflavina sob irradiação UVA. Observou-seum efeito catalisador atribuído a riboflavina noprocesso <strong>de</strong>nominado fotopolimerização do colágeno,com conseqüente aumento na resistência da estruturacolágena atribuída à formação <strong>de</strong> novas ligaçõescovalentes inter e intraestruturais (crosslinking) (6) .A compreensão bioquímica da induçãofotoquímica <strong>de</strong> crosslinking <strong>de</strong> colágeno foi <strong>de</strong>monstradapor Fujimori ainda em 1989. Como efeito, evi<strong>de</strong>nciou-seum aumento no número <strong>de</strong> ligações interfibrilares,com subsequente aumento na estabilida<strong>de</strong> e <strong>de</strong>nsida<strong>de</strong>estrutural (7) .No final da década <strong>de</strong> 90, Spoerl et al. propuseramo uso <strong>de</strong> luz ultravioleta associada a um agentefotossensibilizante (riboflavina) para indução dareticulação do colágeno corneano (8) .Efeitos biomecânicosEm córneas normais, a estrutura do estroma é formadapor cerca <strong>de</strong> 300 lamelas <strong>de</strong> colágeno <strong>de</strong> tamanhosque variam entre 0,5 a 250µm, e espessura entre0,2 a 2,5µm. Cada lamela é composta por fibrilas <strong>de</strong>colágeno dispostas paralelamente, e cada fibrila, por suavez, composta por micromoléculas <strong>de</strong> polipeptí<strong>de</strong>os separadosem ca<strong>de</strong>ias (9) .A estabilida<strong>de</strong> biomecânica da córnea <strong>de</strong>pen<strong>de</strong>diretamente da interrelação <strong>de</strong>stas estruturas e da manutenção<strong>de</strong> sua arquitetura. Em todos os níveis <strong>de</strong>stecomplexo morfológico encontram-se ligações do tipocrosslinking: intermoleculares, interfibrilares einterlamelares (10) .Em estudo <strong>de</strong> córneas com ceratocone, Stachs etal. observaram irregularida<strong>de</strong> estrutural na disposiçãodos ceratócitos, bem como diminuição das lamelas oblíquas<strong>de</strong> orientação ântero-posterior no estroma anterior(11,12) .O protocolo proposto <strong>de</strong> irradiação UVA comriboflavina em olhos <strong>de</strong> suínos e olhos humanos postmorten <strong>de</strong>monstrou um aumento na rigi<strong>de</strong>z elástica total<strong>de</strong> 328% nas córneas humanas tratadas, quando comparadasao grupo controle. Este efeito mostrou-se mais evi<strong>de</strong>nteem olhos humanos se comparados ao <strong>de</strong> suínos, on<strong>de</strong>o incremento na resistência foi <strong>de</strong> apenas 71,9%% (13,14) .Estes resultados são justificados pelo fato <strong>de</strong> quea irradiação UVA associada à riboflavina apresenta umaabsorção <strong>de</strong> 70% <strong>de</strong> sua intensida<strong>de</strong> concentrada nos200 a 300µm anteriores da córnea. Tendo a córnea humanaem média 550µm <strong>de</strong> espessura central e a <strong>de</strong> suínos850µm, esta medida torna-se proporcionalmentemaior nas córneas humanas (13,14) .Efeitos termomecânicosA <strong>de</strong>snaturação das moléculas <strong>de</strong> colágeno através<strong>de</strong> processos termoinduzidos resulta em perda daconformida<strong>de</strong> helicoidal <strong>de</strong> sua estrutura e consequente<strong>de</strong>saparecimento <strong>de</strong> sua birrefringência (15) . O estudo<strong>de</strong>stas alterações evi<strong>de</strong>nciou um encurtamento das microfibrilas, com consequente encurtamento do feixecolágeno como um todo (16) . Quando aquecidas acima <strong>de</strong>um ponto crítico, as fibras colágenas apresentam umafase pré-<strong>de</strong>snaturação, com a transição <strong>de</strong> um estado <strong>de</strong>soli<strong>de</strong>z para um estado gelatinoso (15) . Este processo é<strong>de</strong>nominado hialinização, através do qual as ligaçõescovalentes entre as moléculas <strong>de</strong> colágeno são quebradase o processo <strong>de</strong> <strong>de</strong>snaturação se completa.Spoerl et al. observaram os efeitos térmicos emcórneas <strong>de</strong> suínos tratadas com diferentes intensida<strong>de</strong>s<strong>de</strong> temperatura comparando-as com córneas não tratadas.Evi<strong>de</strong>nciou-se um incremento significativo no limiarmáximo <strong>de</strong> encurtamento pós-<strong>de</strong>snaturação no grupo<strong>de</strong> córneas tratadas (15) .Rev Bras Oftalmol. 2009; 68 (6): 359-64


“Crosslinking”<strong>de</strong> colágeno no tratamento do ceratocone361Este efeito, no entanto, não se mostra homogêneono tecido corneano. Durante a análise histológica ebiomicroscópica dos botões corneanos submetidos à temperatura<strong>de</strong> 70º C pô<strong>de</strong>-se observar um efeito predominantementeacentuado nas 200µm anteriores da córnea,on<strong>de</strong> a arquitetura organizada e a presença <strong>de</strong>birrefringência ainda encontravam-se presentes (15) .Efeitos morfológicosDurante o processo <strong>de</strong> envelhecimento naturaldo tecido corneano ocorre um aumento no diâmetro dafibra <strong>de</strong> colágeno <strong>de</strong> 4,5% (17,18) . As alterações <strong>de</strong>scritasno processo <strong>de</strong> envelhecimento foram evi<strong>de</strong>nciadas namicroscopia eletrônica <strong>de</strong> córneas <strong>de</strong> coelhos submetidosao procedimento <strong>de</strong> crosslinking induzido pela UVAassociado à riboflavina (16) . As fibras <strong>de</strong> colágenocorneano apresentaram um aumento, em média, <strong>de</strong>12,2% <strong>de</strong> seu diâmetro no estroma anterior e 4,6% noestroma posterior quando comparado ao grupo controle.A diferença <strong>de</strong> 9,3% maior do efeito no estroma anteriorem relação ao posterior corroborou para evidênciapreviamente <strong>de</strong>scrita <strong>de</strong> uma indução maior <strong>de</strong>crosslinking na porção anterior da córnea (19) .O diâmetro da fibra colágena <strong>de</strong>monstrada porWollensak et al. neste experimento obteve um aumentomédio na or<strong>de</strong>m <strong>de</strong> 3,96 nm (16) . Não houve perda datransparência corneana em nenhuma amostra corroborandopara evidência <strong>de</strong> um procedimento seguro (19) .Efeitos enzimáticosEm pacientes com ceratocone a <strong>de</strong>tecção <strong>de</strong> produtosresultantes da <strong>de</strong>gradação do colágeno(telopeptí<strong>de</strong>os), <strong>de</strong>tectadas na lágrima, foi <strong>de</strong>monstradacomo sendo cerca <strong>de</strong> 3,5 vezes maior, quando comparadoao grupo controle. Esta evidência contribuiu tardiamentepara a <strong>de</strong>tecção <strong>de</strong> um catabolismo enzimáticoacelerada no ceratocone, quando comparado a olhosnormais (20,21) .Durante o processo <strong>de</strong> estudos laboratoriais, nointuito <strong>de</strong> avaliar os efeitos do tratamento <strong>de</strong> crosslinkingfotoinduzido, foi possível observar um importante<strong>de</strong>créscimo nas taxas dos subprodutos da <strong>de</strong>gradaçãodo colágeno em córneas tratadas. A este fato atribui-seuma menor ativida<strong>de</strong> <strong>de</strong> algumas enzimas envolvidasno turn-over <strong>de</strong> colágeno corneano, como asmetaloproteinases matriciais tipo 1 e 13 (MMP’s),tripsina humana tipo 2 e catepsina K (22) .Efeitos sobre os ceratócitosA radiação ultravioleta, por si só, po<strong>de</strong> exercerum efeito <strong>de</strong>letério na camada <strong>de</strong> ceratócitos. A intensida<strong>de</strong><strong>de</strong>ste efeito está diretamente ligada ao comprimento<strong>de</strong> onda <strong>de</strong> cada um <strong>de</strong> seus espectros. O espectroUVA é o maior <strong>de</strong> todos, com comprimento entre 315 e400nm. Esta característica confere ao mesmo uma capacida<strong>de</strong><strong>de</strong> transmissão na or<strong>de</strong>m <strong>de</strong> 25 a 35% <strong>de</strong> suairradiação às camadas mais profundas da córnea, sendoabsorvido no estroma anterior on<strong>de</strong> exerce importanteefeito citotóxico (23) .O processo <strong>de</strong> <strong>de</strong>sepitelização corneana tambémexerce um efeito lesivo aos ceratócitos, porém <strong>de</strong> formamenos intensa, acometendo somente os 50µm anterioresda córnea. A riboflavina, por ser uma substânciaendógena, não exerce qualquer efeito citotóxico diretoao estroma corneano (23,24) .Wollensak et al. <strong>de</strong>monstraram in vitro os efeitosda irradiação proposta para o tratamento do ceratoconeem culturas <strong>de</strong> ceratócitos provenientes <strong>de</strong> córneas <strong>de</strong>suínos. A análise dos tecidos tratados sob diferentes intensida<strong>de</strong>s<strong>de</strong>monstrou um limiar <strong>de</strong> citotoxicida<strong>de</strong> naor<strong>de</strong>m <strong>de</strong> 5mW/cm² quando somente tratada com UVA,e uma redução para 0,5 mW/cm² quando se utilizou aassociação UVA-riboflavina. Estes resultados evi<strong>de</strong>nciama função catalisadora da riboflavina no processo (24) .Posteriormente, Wollensak et al. estudaram através<strong>de</strong> microscopia eletrônica, córneas <strong>de</strong> suínos tratadassob diversas intensida<strong>de</strong>s <strong>de</strong> irradiação. Os achadosin vivo <strong>de</strong>monstraram bastante semelhança com o experimentoanterior utilizando cultura <strong>de</strong> ceratócitos suínos,reafirmando o limiar <strong>de</strong> citotoxicida<strong>de</strong> (25) .Nestes estudos, não foi observado nenhum caso<strong>de</strong> alteração na transparência ou espessura corneana,efeito também ausente durante a realização <strong>de</strong> ensaiosclínicos com humanos que serão <strong>de</strong>scritos a seguir (24,25) .Efeitos colateraisA radiação UV representa um importante fatorlesivo à córnea, cristalino, e retina. Os danos causadospelos raios UV <strong>de</strong>pen<strong>de</strong>m do comprimento <strong>de</strong> onda daradiação, da área sobre a qual ela inci<strong>de</strong>, bem como dotempo <strong>de</strong> exposição.Na ausência <strong>de</strong> um fotossensibilizante, lesõesendoteliais foram <strong>de</strong>monstradas na presença <strong>de</strong> comprimentos<strong>de</strong> ondas maiores que 350nm e intensida<strong>de</strong>superior a 3mW/cm² (26) . Durante experimentos realizados,o limiar <strong>de</strong> segurança para a lesão fotoativa foi<strong>de</strong> 70 J/cm² para o cristalino, 42 J/cm² para a córneae 4.3 m W/cm² para a retina (24,25,27) .Comparando-se estes valores citados à dose utilizadadurante o procedimento <strong>de</strong> crosslinking UVA-R induzidoem humanos (3mW/cm², 5.4 J/cm²), nenhum dano é esperadono endotélio corneano, cristalino ou mesmo retina (24,25,27) .Rev Bras Oftalmol. 2009; 68 (6): 359-64


362Amaral RC, Solari HPA concentração da riboflavina instilada nasuperfície ocular apresenta significativa relevância noprocesso <strong>de</strong> absorção e difusão da mesma nas camadasmais profundas da córnea. Com um peso molecular <strong>de</strong>376,37 g/mol, o epitélio intacto representa uma barreiraà sua difusão, fazendo-se <strong>de</strong> forma lenta e incompleta.Por esse motivo, <strong>de</strong>ve-se realizar o <strong>de</strong>sbridamento préviodo epitélio corneano, no intuito <strong>de</strong> acelerar a saturação<strong>de</strong> riboflavina no estroma corneano (27,28) .O coeficiente <strong>de</strong> absorção da solução <strong>de</strong>riboflavina aumenta linearmente até uma concentração<strong>de</strong> 0,04%, mantendo-se constante a partir <strong>de</strong>ste pontopara concentrações entre 0,05% e 0,1%. Após trintaminutos da aplicação, a concentração <strong>de</strong> 0,04% <strong>de</strong>riboflavina passa a ser <strong>de</strong>tectável em qualquer ponto auma profundida<strong>de</strong> <strong>de</strong> 400µm, apresentando um <strong>de</strong>créscimo<strong>de</strong> concentração à medida que se aprofunda notecido corneano. Esta concentração cria uma espécie <strong>de</strong>barreira adicional a todas as estruturas localizadas posteriormenteao estroma corneano, incluindo endotéliocorneano, câmara anterior, íris, cristalino e retina (28) .A citotoxicida<strong>de</strong> da irradiação UVA-R durante aexposição terapêutica e seus efeitos na camada <strong>de</strong>ceratócitos e endotélio foi estudada por Wollensak etal. (23,24) . Em córneas <strong>de</strong> coelhos e em cultura in vitro <strong>de</strong>ceratócitos <strong>de</strong> suínos, após o tratamento com UVA-Rsob os parâmetros recomendados, foi observada apoptose<strong>de</strong> ceratócitos a uma profundida<strong>de</strong> <strong>de</strong> até 300µm (23,24) .Em conformida<strong>de</strong> com estes achados laboratoriais, amicroscopia confocal <strong>de</strong> 10 córneas tratadas nosparâmetros recomendados revelou morte <strong>de</strong> ceratócitosa uma profundida<strong>de</strong> <strong>de</strong> 270-350µm no estroma, comrepopularização e recuperação total <strong>de</strong> sua <strong>de</strong>nsida<strong>de</strong>celular após seis meses do tratamento. Nenhum dano aoendotélio foi observado em qualquer momento do tratamento(29) .No ensaio clínico mais recente, on<strong>de</strong> foram estudadosefeitos colaterais do tratamento em córneas <strong>de</strong>humanos tratadas in vivo, foram relatados como efeitoscolaterais: opacida<strong>de</strong> estromal leve transitória eautolimitada, infiltrado estromal estéril na proporção <strong>de</strong>7.6% e cicatriz estromal em 2.8% dos casos (30) .Estudos clínicosO pioneirismo na utilização <strong>de</strong> UVA-R em pacientescom ceratocone data <strong>de</strong> 1998, na Alemanha, quandoWollensack et al. trataram 16 olhos com diagnóstico<strong>de</strong> ceratocone progressivo e mo<strong>de</strong>rado. Após o acompanhamentoentre 1 e 3 anos, a progressão do ceratoconefoi paralisada em todos os casos, com melhora daacuida<strong>de</strong> visual e redução do valor ceratométrico máximoem 50% dos casos. Em nenhum caso foi observadaqualquer perda na transparência corneana ou diminuiçãona celularida<strong>de</strong> endotelial (31) .Na segunda fase <strong>de</strong>ste ensaio, 22 pacientes comceratocone mo<strong>de</strong>rado a avançado foram tratados, com52% dos olhos incluídos apresentando progressão dadoença, com valor ceratométrico máximo entre 48 e 72dioptrias. A progressão do ceratocone foi interrompidaem todos os pacientes tratados, além disso, em 70% doscasos ocorreu uma redução <strong>de</strong> duas dioptrias no valorceratométrico (K) máximo. A acuida<strong>de</strong> visual medidaapós a melhor correção apresentou ganho médio <strong>de</strong> 1,26linhas, com redução <strong>de</strong> 1,14 ± 2.18 dioptrias <strong>de</strong> equivalenteesférico. Em 22% dos olhos contralaterais utilizadoscomo controles, no entanto, houve progressão daectasia com um aumento médio <strong>de</strong> 1,48 dioptrias naceratometria máxima. A transparência da córnea e docristalino, bem como a <strong>de</strong>nsida<strong>de</strong> das células endoteliaispermaneceram inalteradas (32) .<strong>Nov</strong>os resultados obtidos com acompanhamento<strong>de</strong> 3 a 5 anos, também em Dres<strong>de</strong>n, mostraram que todosos 60 olhos com ceratocone tratados pararam <strong>de</strong> evoluir.Em 31 olhos ocorreu um aplanamento discreto do conecom valor médio <strong>de</strong> 2,87 D e a melhor acuida<strong>de</strong> visualcorrigida aumentou em 1,4 linhas (33) .Outro estudo europeu mostrou uma redução média<strong>de</strong> 2,5 D no equivalente esférico, confirmada topograficamente,com melhora na acuida<strong>de</strong> visual e diminuição<strong>de</strong> parâmetros topográficos. Caporossi et al. eMazzotta et al. publicaram seus resultadoscorrelacionando os dados clínicos com evidências observadasà microscopia confocal e topoaberrometria noseguimento <strong>de</strong> seis meses (29,34) . O HRT II-RCM(Hei<strong>de</strong>lberg Retinal Tomograph II Rodstock CornealModule) registrou um efeito confinado aos 350µm anterioresda córnea, enquanto que a topoaberrometria <strong>de</strong>tectouum aumento na simetria corneana (34) .Nestes estudos não houve evidências <strong>de</strong> qualqueralteração endotelial ou da pressão intraocular e pô<strong>de</strong>-seconfirmar in vivo o potencial <strong>de</strong> regeneração da camada<strong>de</strong> ceratócitos já especulada durante os ensaioslaboratoriais (25,27,29,34) .Des<strong>de</strong> o início dos ensaios clínicos, mais <strong>de</strong> 272pacientes, contabilizando um total <strong>de</strong> 480 olhos comceratocone foram submetidos ao tratamento com o crosslinkingem Dres<strong>de</strong>n. A recente publicação dos resultadosapós o acompanhamento dos pacientes pelo período<strong>de</strong> 6 anos confirmou a tendência positiva dos resultadospreliminares. Ao final do terceiro ano, o aplainamentodo ápice corneano <strong>de</strong>monstrou um <strong>de</strong>créscimo do valorceratométrico máximo na or<strong>de</strong>m <strong>de</strong> 4.84 dioptrias. OsRev Bras Oftalmol. 2009; 68 (6): 359-64


“Crosslinking”<strong>de</strong> colágeno no tratamento do ceratocone363parâmetros clínicos também obtiveram bons resultados,mostrando ganho <strong>de</strong> pelo menos uma linha <strong>de</strong> visão natabela EDTRS em 57% dos pacientes em média e aausência <strong>de</strong> perdas <strong>de</strong> mais linhas, em aproximadamente22%% (35) .No Brasil, em 2008, Lamy et al. publicaram osresultados preliminares obtidos através da aplicação doprotocolo internacional em pacientes do Hospital Universitárioda Universida<strong>de</strong> Fe<strong>de</strong>ral do Rio <strong>de</strong> Janeiro.Foram tratados 37 olhos com análise ao final <strong>de</strong> 90 dias.Os resultados mostraram uma redução do po<strong>de</strong>r dióptricomédio (PDM) em até 1,3 dioptrias em 83,8% dos olhos eum aumento <strong>de</strong> 0,3 dioptrias em 16,2%, apresentandoportanto uma média <strong>de</strong> 0,4 dioptrias <strong>de</strong> <strong>de</strong>créscimo. Ovalor ceratométrico máximo reduziu 0,6 dioptrias emmédia nos 3 milímetros centrais e a acuida<strong>de</strong> visualcorrigida evoluiu com melhora média <strong>de</strong> 6,27 letras (36) .Em suma, po<strong>de</strong>-se concluir que a utilização clínicasegura da irradiação UVA-R em córneas <strong>de</strong> humanos,no tratamento do ceratocone, <strong>de</strong>pen<strong>de</strong> <strong>de</strong> criteriosaseleção <strong>de</strong> pacientes e da manutenção das recomendaçõestécnicas protocoladas. A literatura evi<strong>de</strong>ncia resultadospromissores, porém são ainda necessários maisestudos prospectivos com maior número <strong>de</strong> pacientes etempo <strong>de</strong> acompanhamento para confirmação da eficáciae segurança <strong>de</strong>ste novo procedimento.ABSTRACTIn middle of 90th <strong>de</strong>ca<strong>de</strong>, corneal collagen crosslinkingphoto-induced by riboflavin was consi<strong>de</strong>red as a newtherapeutical modality in the treatment of keratoconus.Since then, the clinical effect of this procedure inlaboratorial environment and clinical assays had beenstudied. In this article, we revise the literature alreadypublished until the moment in or<strong>de</strong>r to display on theprocedure and its effects.Keywords: Keratoconus/therapy; Collagen/radiation effects; Riboflavin/therapeutic use; Ultraviolettherapy; Phototherapy; Ultraviolet rays; CrosslinkingreagentsREFERÊNCIAS1. Seiler T, Spoerl E, Huhle M, Kamouna A. Conservativetherapy of keratoconus by enhancement of collagen crosslinks.Invest Ophthalmol Vis Sci. 1996;37:S10172. Amsler M. [Some data on the problem of keratoconus].BullSoc Belge Ophtalmol. 1961;129:331-54. French.3. Mano EB, Men<strong>de</strong>s LC. Introdução a polímeros. 2a ed. SãoPaulo: Blücher; 1999.4. Prockop DJ, Kivirikko KI, Tu<strong>de</strong>rman L, Guzman NA. Thebiosynthesis of collagen and its disor<strong>de</strong>rs (first of two parts).N Engl J Med. 1979;301(1):13-23.5. Andra<strong>de</strong> CT, Coutinho FM, Dias ML, Lucas EF, Oliveira CM, TabakD. Dicionário <strong>de</strong> polímeros. Rio <strong>de</strong> Janeiro: Interciência; 2001.6. Dalle Carbonare M, Pathak MA. Skin photosensitizing agentsand the role of reactive oxygen species in photoaging. JPhotochem Photobiol B. 1992;14(1-2):105-24.7. Fujimori E. Cross-linking and fluorescence changes of collagenby glycation and oxidation. Biochim Biophys Acta.1989;998(2):105-10.8. Spoerl E, Huhle M, Seiler T. Induction of cross-links in cornealtissue. Exp Eye Res. 1998;66(1):97-1039. Maurice DM.The structure and transparency of the cornea. JPhysiol.1957;136(2):263-86.10. Muller LJ, Pels E,Vrensen GF. The specific architecture ofthe anterior stroma accounts for maintenance of cornealcurvature. Br J Ophthalmol. 2001;85(4):437–443.11. Daxer A,Fratzl P.Collagen fibril orientation in the humancorneal stroma and its implication in keratoconus. InvestOphthalmol Vis Sci. 1997;38(1):121–9.12. Stachs O, Bochert A, Gerber T, Koczan D, Thiessen HJ, GuthoffRF. [The extracellular matrix structure in keratoconus].Ophthalmologe. 2004;101(4):384-9.13. Kohlhaas M, Spoerl E, Schil<strong>de</strong> T, Unger G, Wittig C, PillunatLE. Biomechanical evi<strong>de</strong>nce of the distribution of cross-linksin corneas treated with riboflavin and ultraviolet A light. JCataract Refract Surg. 2006;32(2):279-83.14. Wollensak G, Spoerl E, Seiler T. Stress-strain measurements ofhuman and porcine corneas after riboflavin-ultraviolet-A-inducedcross-linking. J Cataract Refract Surg. 2003;29(9):1780-5.15. Spoerl E, Wollensak G, Dittert DD, Seiler T. Thermomechanicalbehavior of collagen-cross-linked porcine cornea.Ophthalmologica. 2004; 218(2):136-40.16. Wollensak G, Wilsch M, Spoerl E, Seiler T. Collagen fiberdiameter in the rabbit cornea after collagen crosslinking byriboflavin/UVA. Cornea. 2004;23(5):503-7.17. Daxer A, Misof K, Grabner B, Ettl A, Fratzl P. Collagen fibrilsin the human corneal stroma: structure and aging. InvestOphthalmol Vis Sci. 1998;39(3):644-8.18. Bailey AJ. Structure, function and ageing of the collagens ofthe eye. Eye. 1987;1(Pt 2):175–83.19. Freund DE, McCally RL, Farrell RA, Cristol SM, L’HernaultNL, E<strong>de</strong>lhauser HF. Ultrastructure in anterior and posteriorstroma of perfused human and rabbit corneas. Relation totransparency. Invest Ophthalmol Vis Sci. 1995;36(8):1508-23.20. Abalain, J. H. Ph.D.; Dossou, H. M.D.; Colin, J. M.D.; Floch, H.H. M.D. Levels of Collagen Degradation Products(Telopepti<strong>de</strong>s) in the Tear Film of Patients with Keratoconus.Cornea. 2000;19(4):474-7621. Zhou L, Sawaguchi S, Twining SS, Sugar J, Fe<strong>de</strong>r RS, Yue BY.Expression of <strong>de</strong>gradative enzymes and protease inhibitorsin corneas with keratoconus. Invest Ophthalmol Vis Sci.1998;39(7):1117-24.22. Spoerl E, Wollensak G, Seiler T. Increased resistance ofcrosslinked cornea against enzymatic digestion. Curr Eye Res.2004;29(1):35-40.23. Wollensak G, Spoerl E, Wilsch M, Seiler T. Keratocyteapoptosis after corneal collagen cross-linking using riboflavin/UVAtreatment. Cornea. 2004;23(1):43-9.24. Wollensak G, Spoerl E, Reber F, Seiler T. Keratocyte cytotoxicityof riboflavin/UVA-treatment in vitro. Eye (Lond).2004;18(7):718-22.Rev Bras Oftalmol. 2009; 68 (6): 359-64


364Amaral RC, Solari HP25. Wollensak G, Spoerl E, Reber F, Pillunat L, Funk R. Cornealendothelial cytotoxicity of riboflavin/UVA treatment in vitro.Ophthalmic Res. 2003;35(6):324-8.26. Pitts DG. Glenn A. Fry Award Lecture—1977. The oculareffects of ultraviolet radiation. Am J Optom Physiol Opt.1978;55(1):19-35.27. Spoerl E, Mrochen M, Sliney D, Trokel S, Seiler T. Safety of UVAriboflavincross-linking of the cornea. Cornea. 2007; 26(4): 385-9.28. Prausnitz MR, Noonan JS. Permeability of cornea, sclera, andconjunctiva: a literature analysis for drug <strong>de</strong>livery to the eye.J Pharm Sci. 1998;87(12):1479-88.29. Mazzotta C, Balestrazzi A, Traversi C, Baiocchi S, Caporossi T,Tommasi C, Caporossi A. Treatment of progressive keratoconusby riboflavin-UVA-induced cross-linking of corneal collagen:ultrastructural analysis by Hei<strong>de</strong>lberg Retinal Tomograph II invivo confocal microscopy in humans. Cornea. 2007;26(4):390-7.30. Koller T, Mrochen M, Seiler T. Complication and failure ratesafter corneal crosslinking. J Cataract Refract Surg.2009;35(8):1358-1362.31. Wollensak G, Spörl E, Seiler T. [Treatment of keratoconus bycollagen cross linking]. Ophthalmologe. 2003;100(1):44-9.32. Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-A-inducedcollagen crosslinking for the treatment of keratoconus.Am J Ophthalmol. 2003;135(5):620-7.33. Wollensak G.Crosslinking treatment of progressive keratoconus:new hope. Curr Opin Ophthalmol. 2006Aug;17(4):356-60.34. Caporossi A, Baiocchi S, Mazzotta C, Traversi C, Caporossi T.Parasurgical therapy for keratoconus by riboflavin-ultraviolettype A rays induced cross-linking of corneal collagen:preliminary refractive results in an Italian study. J CataractRefract Surg. 2006;32(5):837-45.35. Raiskup-Wolf F, Hoyer A, Spoerl E, Pillunat LE. Collagencrosslinking with riboflavin and ultraviolet-A light in keratoconus:long-term results. J Cataract Refract Surg.2008;34(5):796-801.36. Lamy R, Netto CF, Pecego MG, Pecego JG, Pereira BB, MoraesJúnior, HV, et al. Reticulação do colágeno corneano comradiação ultravioleta e riboflavina para tratamento doceratocone: resultados preliminares <strong>de</strong> um estudo brasileiro.Rev Bras Oftalmol. 2008; 67(5):231-5.En<strong>de</strong>reço para correspondênciaHelena Parente SolariAv. Mariz e Barros, nº 459 - IcaraíCEP 24220-120 - Niterói - RJ - BrasilRev Bras Oftalmol. 2009; 68 (6): 359-64


365Índice remissivo do volume 68AutoresED. PÁG.Almeida, Hen<strong>de</strong>rson Celestino <strong>de</strong>... et al. - Estudo comparativo daação da toxina botulínica tipo A e da crotoxina sobre as célulassatélites da musculatura extrínseca ocular em mo<strong>de</strong>lo animal ........ 5 296Almeida, Homero Gusmão <strong>de</strong>... et al. - Antiphospholipid syndromeand retinal vein occlusion ......................................................................... 2 100Almodin, Edna... et al. - Tratamento aditivo do ceratocone por‘crosslinking’ do colágeno após implante <strong>de</strong> anel <strong>de</strong> Ferrara .......... 3 138Almodin, Juliana... et al. - Tratamento aditivo do ceratocone por‘crosslinking’ do colágeno após implante <strong>de</strong> anel <strong>de</strong> Ferrara .......... 3 138Alves, Milton Ruiz... et al. - Avaliação clínica comparativa <strong>de</strong> lentesprogressivas na correção da presbiopia ................................................ 3 129Amador, Rodrigo Carvalho... et al. - Resultados da associaçãotrabeculotomia-trabeculectomia em pacientes não idosos ................ 4 223Amaral, Beatriz Lopes Moura Brasil do... et al. - Percepção daadministração tópica ocular <strong>de</strong> drogas: vaporização x gotas ............ 6 327Amaral, Rodrigo Coelho... et al. - ‘Crosslinking’ <strong>de</strong> colágeno notratamento do ceratocone .......................................................................... 6 359Ambrósio Junior, Renato... et al. - Hipertensão ocular “mascarada”por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata: relato <strong>de</strong> caso ........ 6 344Andra<strong>de</strong>, Dorislay Barbosa <strong>de</strong> Sousa Camargo... et al. - Prolapso <strong>de</strong>gordura orbitária e oftalmopatia <strong>de</strong> graves ......................................... 2 103Andra<strong>de</strong>, Marizilda Rita <strong>de</strong>... et al. - Ceratectomia fotorrefrativa(PRK) com mitomicina C a 0,02% para correção <strong>de</strong> grau acentuado<strong>de</strong> astigmatismo hipermetrópico composto secundário a cirurgia <strong>de</strong>ceratotomia radial (RK) ........................................................................... 3 156Aragão, Ricardo Evangelista Marrocos <strong>de</strong>... et al. - Importância doexame oftalmológico na doença <strong>de</strong> von Hippel-Lindau ...................... 4 241Araújo, Rita <strong>de</strong> Cássia Aquino <strong>de</strong>... et al. - Síndrome do bloqueiocapsular precoce relato <strong>de</strong> caso e especulação sobre o tamanho daparte óptica da lente como fator <strong>de</strong> risco .................................................. 6 344Arschinoff, Steve... et al. - Tratamento aditivo do ceratocone por‘crosslinking’ do colágeno após implante <strong>de</strong> anel <strong>de</strong> Ferrara .......... 3 138Athanázio, Paulo Roberto Fontes... et al. - Metástase orbital comoprimeira manifestação clínica <strong>de</strong> hepatocarcinoma ............................ 4 245Avakian, Amaryllis... et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Avakian, Amaryllis... et al. - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySof Restorlens ................................................................................................................. 4 216Barbosa, Manuela Maria Valença Cor<strong>de</strong>iro... et al - Avaliação damicrobiota ocular em pacientes com disfunção do filme lacrimal .... 6 332Barreira, Iêda Maria Alexandre... et al. - Importância do exameoftalmológico na doença <strong>de</strong> von Hippel-Lindau ................................... 4 241Barreto, Rodrigo <strong>de</strong> Pinho Paes... et al. - Uso <strong>de</strong> ciclosporina 0,05%tópica no tratamento do olho seco <strong>de</strong> pacientes portadores do vírusHIV ................................................................................................................. 2 83Belfort Junior, Rubens... et al. - Avaliação <strong>de</strong> sistema <strong>de</strong> leituraportátil (SLP) para baixa visão <strong>de</strong>senvolvido no Brasil .................... 5 259Berezovsky, Adriana... et al. - Avaliação <strong>de</strong> sistema <strong>de</strong> leituraportátil (SLP) para baixa visão <strong>de</strong>senvolvido no Brasil .................... 5 259Bernar<strong>de</strong>s, Taliana Freitas ... et al. - Entrópio congênito primário dapálpebra superior ....................................................................................... 1 53Bertino, Pedro Moreira... et al. - Perfil do paciente com ceratopatiabolhosa pós-facectomia atendidos em hospital público ...................... 4 201ED. PÁG.Betinjane, Alberto Jorge... et al. - Estudo comparativo entre imagensultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHz naavaliação <strong>de</strong> anormalida<strong>de</strong>s do segmento posterior doglobo ocular .................................................................................................. 5 291Bezerra, Andreya Ferreira Rodrigues... et al. - Importância do exameoftalmológico na doença <strong>de</strong> von Hippel-Lindau ................................... 4 241Biancardi, Ana Luiza ... et al. - Uso <strong>de</strong> ciclosporina 0,05% tópica notratamento do olho seco <strong>de</strong> pacientes portadores do vírus HIV ....... 2 83Bonomo, Pedro Paulo... et al. - Prevalência e fatores <strong>de</strong> risco para aretinopatia da prematurida<strong>de</strong>: estudo com 450 pré-termos <strong>de</strong> muitobaixo peso ..................................................................................................... 1 22Brandão, Juliana Cabral Duarte... et al. - Metástase orbital comoprimeira manifestação clínica <strong>de</strong> hepatocarcinoma ............................ 4 245Caballero, Juan Carlos... et al. - A neutralização do astigmatismocorneano durante a cirurgia da catarata por meio <strong>de</strong> lente intraoculartórica: resultados ......................................................................................... 2 76Caliari, Larissa Casteluber... et al. - Retinopatia <strong>de</strong> Purtscher ePurtscher-like .............................................................................................. 2 114Calucci, Daniela... et al. - Avaliação ocular multimodal em doençasheredodistróficas e <strong>de</strong>generativas da retina ........................................ 5 309Campos, Christian Marcellus <strong>de</strong> Camargo... et al. - Antiphospholipidsyndrome and retinal vein occlusion ...................................................... 2 100Canedo, Ana Laura... et al. - Hipertensão ocular “mascarada” pore<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata .......................................... 6 348Carani, José Carlos Eu<strong>de</strong>s... et al. - Estudo comparativo entre imagensultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHz naavaliação <strong>de</strong> anormalida<strong>de</strong>s do segmento posterior do globoocular ............................................................................................................. 5 291Carneiro, Rachel Camargo... et al. - Imunoterapia tópica notratamento do carcinoma basocelular periocular – relato <strong>de</strong> caso ... 6 355Carricondo, Pedro Carlos... et al. - Alterações na tela <strong>de</strong> Amsler entrepacientes com catarata senil ...................................................................... 1 18Carvalho, Durval Moraes <strong>de</strong>... et al. - Endoscopiccyclophotocoagulation in refractory glaucomas: a long term study .... 3 146Castanheira, Vera Regina Cardoso... et al. - Estudo comparativo entreimagens ultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHzna avaliação <strong>de</strong> anormalida<strong>de</strong>s do segmento posterior do globoocular ............................................................................................................. 5 291Cavalcante, Adhele Furlani <strong>de</strong> Sá... et al. - Estudo comparativo entreimagens ultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHzna avaliação <strong>de</strong> anormalida<strong>de</strong>s do segmento posterior doglobo ocular .................................................................................................. 5 291Centurion, Virgilio... et al. - A neutralização do astigmatismo corneanodurante a cirurgia da catarata por meio <strong>de</strong> lente intraoculartórica: resultados .......................................................................................... 2 76Centurion, Virgilio... et al. - Excelência em cirurgia <strong>de</strong> cristalino ...... 5 257Cheng Te Cheng... et al. - Estudo comparativo entre imagensultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHz na avaliação<strong>de</strong> anormalida<strong>de</strong>s do segmento posterior do globo ocular ................... 5 291Coblentz , Jacqueline... et al. - Aspectos atuais no diagnóstico do e<strong>de</strong>mamacular diabético ......................................................................................... 1 59Coelho, Maria do Carmo Jordão... et al. - Estudo comparativo da açãoda toxina botulínica tipo A e da crotoxina sobre as células satélitesda musculatura extrínseca ocular em mo<strong>de</strong>lo animal ......................... 5 296Costa, Marlene Coelho da... et al. - Prevalência e fatores <strong>de</strong> riscopara a retinopatia da prematurida<strong>de</strong>: estudo com 450 pré-termos <strong>de</strong>muito baixo peso .......................................................................................... 1 22Rev Bras Oftalmol. 2009; 68 (6): 365-71


366ED. PÁG.Costa Filho, Adroaldo <strong>de</strong> Alencar... et al. - Ensino <strong>de</strong> oftalmologiana graduação médica. Estudo comparativo <strong>de</strong> aprendizado naoftalmoscopia direta com oftalmoscópio convencional e <strong>de</strong> campoamplo (Panoptic) ......................................................................................... 4 231Costa Filho, Adroaldo <strong>de</strong> Alencar... et al. - Tendências evolutivasdos cirurgiões <strong>de</strong> catarata presentes no IV Congresso Brasileiro <strong>de</strong>Catarata e Cirurgia Refrativa .................................................................. 1 13Costa, Alinne Maria Camargos da ...et al. - Antiphospholipidsyndrome and retinal vein occlusion ...................................................... 2 100Costa, Rogério Alves... et al. - Avaliação ocular multimodal emdoenças heredodistróficas e <strong>de</strong>generativas da retina ........................ 5 309Couto Junior, Abelardo <strong>de</strong> Souza... et al. - Prevalência da retinopatiadiabética em unida<strong>de</strong> do Programa <strong>de</strong> Saú<strong>de</strong> da Família ................... 2 90Crema, Armando Stefano... et al. - Facectomia na infância: quem sãonossos pacientes? ........................................................................................ 3 134Dalfré, Joyce Treinta... et al. - Emergências oftalmológicas em umhospital dia ................................................................................................... 4 197Dalfré, Joyce Treinta... et al. - Corpo estranho intracristaliniano .... 2 96Damasceno, Eduardo <strong>de</strong> França... et al. - Ensino <strong>de</strong> oftalmologia nagraduação médica. Estudo comparativo <strong>de</strong> aprendizado naoftalmoscopia direta com oftalmoscópio convencional e <strong>de</strong> campoamplo (Panoptic) ......................................................................................... 4 231Damasceno, Nadyr Antonia Pereira... et al. - Ensino <strong>de</strong> oftalmologiana graduação médica. Estudo comparativo <strong>de</strong> aprendizado naoftalmoscopia direta com oftalmoscópio convencional e <strong>de</strong> campoamplo (Panoptic) ......................................................................................... 4 231Duarte Brandão, Juliana Cabral...et al. - Metástase orbital comoprimeira manifestação clínica <strong>de</strong> hepatocarcinoma ............................ 4 245Eckert , Gabriela Unchalo ... et al. - Prevalência e fatores <strong>de</strong> riscopara a retinopatia da prematurida<strong>de</strong>: estudo com 450 pré-termos <strong>de</strong>muito baixo peso .......................................................................................... 1 22Eduardo Ferrari, Marback ...et al. - Síndrome do bloqueio capsularprecoce relato <strong>de</strong> caso e especulação sobre o tamanho da parte ópticada lente como fator <strong>de</strong> risco ...................................................................... 6 344Fante, Danilo...et al. - Comparison between OPD-scan results andcontrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Feres, Rachel Campêlo... et al. - Prolapso <strong>de</strong> gordura orbitária eoftalmopatia <strong>de</strong> Graves .............................................................................. 2 103Fernan<strong>de</strong>s, Celso Lopez... et al. - Função visual <strong>de</strong> criançaspseudofácicas por catarata infantil ......................................................... 5 278Ferrara, Daniela Cavalcanti... et al. - Avaliação ocular multimodalem doenças heredodistróficas e <strong>de</strong>generativas da retina .................. 5 309Ferrara, Paulo...et al. - Tratamento aditivo do ceratocone por‘crosslinking’ do colágeno após implante <strong>de</strong> anel <strong>de</strong> Ferrara .......... 3 138Ferraz, Patrícia da Rocha Pitta... et al. - Função visual <strong>de</strong> criançaspseudofácicas por catarata infantil ......................................................... 5 278Ferreira, Ana Luiza Lise...et al. - Fixação iriana <strong>de</strong> lentes <strong>de</strong> câmaraposterior para o tratamento da afacia .................................................... 5 284Ferreira, Juliana <strong>de</strong> Lucena Martins... et al. - Evidências obtidas <strong>de</strong>um caso <strong>de</strong> melanoma <strong>de</strong> íris recidivado ................................................ 1 37Flores, Eduardo... et al. - Tratamento do lagoftalmo paralítico com autilização do implante <strong>de</strong> peso <strong>de</strong> ouro recoberto pela aponeurosedo músculo levantador palpebral ............................................................ 1 30Floriano, João Fernan<strong>de</strong>s... et al. - Prevalência <strong>de</strong> infecção porChlamydia Tracomatis em amostras oculares <strong>de</strong> pacientes comconjuntivite em laboratório <strong>de</strong> genética e biologia molecular naregião metropolitana <strong>de</strong> Florianópolis .................................................. 4 206Fortes Filho, João Borges... et al. - Prevalência e fatores <strong>de</strong> riscopara a retinopatia da prematurida<strong>de</strong>: estudo com 450 pré-termos <strong>de</strong>muito baixo peso .......................................................................................... 1 22Fraga, Diego <strong>de</strong> Souza... et al. - Prevalência <strong>de</strong> infecção por ChlamydiaTracomatis em amostras oculares <strong>de</strong> pacientes com conjuntivite emlaboratório <strong>de</strong> genética e biologia molecular na regiãometropolitana <strong>de</strong> Florianópolis ................................................................ 4 206França, Valenio Perez... et al. - Entrópio congênito primário dapálpebra superior ....................................................................................... 1 53ED. PÁG.Freitas, Francisco Valter da Justa... et al. - Como (ainda) ser feliz naprofissão ........................................................................................................ 6 325Freitas, Luiz Antônio Rodrigues <strong>de</strong>... et al. - Papel daimunoistoquímica no diagnóstico das alterações oculares naleishmaniose tegumentar americana. Relato clínico-patológico <strong>de</strong>cinco casos .................................................................................................... 3 152Freitas, Marcelo Siqueira <strong>de</strong> ...et al. - Síndrome do bloqueio capsularprecoce relato <strong>de</strong> caso e especulação sobre o tamanho da parte ópticada lente como fator <strong>de</strong> risco’ .................................................................... 6 344Fujita, Reinaldo... et al. - Comparison of central corneal e<strong>de</strong>ma andvisual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ..................................................... 1 7Gaffree, Fernanda Ferreira Pires ... et al. - Tendências evolutivasdos cirurgiões <strong>de</strong> catarata presentes no IV Congresso Brasileiro <strong>de</strong>Catarata e Cirurgia Refrativa .................................................................. 1 13Gaiotto Júnior, Osmar Antônio... et al. - Corpo estranhointracristaliniano ........................................................................................ 2 96Gaiotto Júnior, Osmar Antônio...et al. - Emergências oftalmológicasem um hospital dia ...................................................................................... 4 197Galvão, Cláudia...et al. - Melanocitoma associado à membrananeovascular subrretiniana ........................................................................ 4 237Garcia, Alessandro Perussi ...et al. - Estesiometria corneana póscirurgiafotorrefrativa ............................................................................... 5 271Giovedi Filho, Renato...et al. - Avaliação clínica comparativa <strong>de</strong>lentes progressivas na correção da presbiopia .................................... 3 129Goe<strong>de</strong>rt, Merry Elizabeth ...et al. - Avaliação da aplicabilida<strong>de</strong> e docusto da profilaxia da oftalmia neonatal em maternida<strong>de</strong>s da gran<strong>de</strong>Florianópolis ................................................................................................ 5 264Gomes, Beatriz <strong>de</strong> Abreu Fiuza ... et al.- Tendências evolutivas doscirurgiões <strong>de</strong> catarata presentes no IV Congresso Brasileiro <strong>de</strong>Catarata e Cirurgia Refrativa .................................................................. 1 13Gomes, Beatriz <strong>de</strong> Abreu Fiúza... et al. - Facectomia na infância: quemsão nossos pacientes? ................................................................................. 3 134Gomes, Beatriz <strong>de</strong> Abreu, Fiúza... et al. - Perfil do paciente comceratopatia bolhosa pós-facectomia atendidos em hospital público. 4 201Gomes, Louise Pellegrino...et al. - Percepção da administração tópicaocular <strong>de</strong> drogas: vaporização x gotas .................................................... 6 327Gonçalves, Roberto Martins...et al. - Antiphospholipid syndrome andretinal vein occlusion ................................................................................. 2 100Gue<strong>de</strong>s, Murielem Fernan<strong>de</strong>s ... et al. - Prevalência da retinopatiadiabética em unida<strong>de</strong> do Programa <strong>de</strong> Saú<strong>de</strong> da Família ................... 2 90Guerra, Fre<strong>de</strong>rico... et al. - Hipertensão ocular “mascarada” pore<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata: relato <strong>de</strong> caso .............. 6 348Hida, Wilson Takashi ... et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Hida, Wilson Takashi ...et al. - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Hida, Wilson Takashi... et al. - Alterações na tela <strong>de</strong> Amsler entrepacientes com catarata senil ..................................................................... 1 18Hirai, Flavio Eduardo ...et al. - Avaliação da microbiota ocular empacientes com disfunção do filme lacrimal ........................................... 6 332Hofling-Lima, Ana Luisa...et al. - Avaliação da microbiota ocular empacientes com disfunção do filme lacrimal ............................................. 6 332Hokazone Kenzo...et al. - Retinal nerve fiber layer loss documentedby optical coherence tomography in patients with optic tractlesions ............................................................................................................ 1 48Hokazono, Kenzo ...et al. - Síndrome do ápice orbitário causada porherpes zóster oftálmico: relato <strong>de</strong> caso e revisão da literatura ........ 5 304Holzchuh, Ricardo... et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Holzchuh, Ricardo...et al. - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Rev Bras Oftalmol. 2009; 68 (6): 365-71


367ED. PÁG.Jales, Martha <strong>de</strong> Queiroz Monteiro...et al. - Membrana neovascularsubrretiniana justapapilar em paciente com papile<strong>de</strong>ma ehipertensão intracraniana idiopática ..................................................... 1 42Kara-Jose Junior, Newton... et al. - Comparison of central corneale<strong>de</strong>ma and visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Kara-Jose Junior, Newton... et al. - Facectomia na infância: quem sãonossos pacientes? ........................................................................................ 3 134Kara-Jose Junior, Newton... et al. - Lentes asféricas: avaliação daindicação clínica e das opções <strong>de</strong> lentes ................................................ 3 175Kara-Jose Junior, Newton... et al. - <strong>Nov</strong>ida<strong>de</strong>s na cirurgia <strong>de</strong> catarata:lentes intraoculares asféricas .................................................................. 4 195Kara-Jose Junior, Newton...et al. - Comparison between OPD-scanresults and contrast sensitivity of three intraocular lenses: sphericAcrySof SN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Kara-Jose, Newton... et al. - Alterações na tela <strong>de</strong> Amsler entrepacientes com catarata senil ..................................................................... 1 18Kara-Junior, Newton... et al. - Alterações na tela <strong>de</strong> Amsler entrepacientes com catarata senil ..................................................................... 1 18Kara-Junior,Newton...et al. - Perfil do paciente ceratopatiabolhosapós-facectomia atendidos em hospital público ....................... 4 201Kiefer, Kélcia...et al. - Resultados da associação trabeculotomiatrabeculectomiaem pacientes não idosos .............................................. 4 223Lacava, Augusto Cézar... et al. - A neutralização do astigmatismocorneano durante a cirurgia da catarata por meio <strong>de</strong> lente intraoculartórica: resultados ......................................................................................... 2 76Lacordia, Marta Halfeld Ferrari Alves...et al. - Estudo comparativoda ação da toxina botulínica tipo A e da crotoxina sobre as célulassatélites da musculatura extrínseca ocular em mo<strong>de</strong>lo animal ........ 5 291Lamim, Raul Fernando Binato...et al. - Estudo comparativo da açãoda toxina botulínica tipo A e da crotoxina sobre as células satélitesda musculatura extrínseca ocular em mo<strong>de</strong>lo animal ......................... 5 291Leite, Cícero Narciso Moreira... et al. - Evidências obtidas <strong>de</strong> umcaso <strong>de</strong> melanoma <strong>de</strong> íris recidivado ...................................................... 1 37Leonor, Ana Carolina Igreja ...et al. - Emergências oftalmológicasem um hospital dia ...................................................................................... 4 197Leonor, Ana Carolina Igreja... et al. - Corpo estranhointracristaliniano ........................................................................................ 2 96Lessa, Sergio... et al. - Tratamento do lagoftalmo paralítico com autilização do implante <strong>de</strong> peso <strong>de</strong> ouro recoberto pela aponeurosedo músculo levantador palpebral ............................................................ 1 30Lima, Eliana Cunha ...et al. - Avaliação <strong>de</strong> sistema <strong>de</strong> leitura portátil(SLP) para baixa visão <strong>de</strong>senvolvido no Brasil ................................... 5 259Lima, Francisco Eduardo...et al. - Endoscopic cyclophotocoagulationin refractory glaucomas: a long term study ........................................... 3 146Lima, Vagner Loduca...et al. - Biometria ultrassônica no cálculo dopo<strong>de</strong>r dióptrico <strong>de</strong> lentes intraoculares: estudo comparativo dosmétodos <strong>de</strong> contato e <strong>de</strong> imersão ............................................................. 4 212Lui, Tatiana Adarli Fioravanti... et al. - Ceratectomia fotorrefrativa(PRK) com mitomicina C a 0,02% para correção <strong>de</strong> grau acentuado<strong>de</strong> astigmatismo hipermetrópico composto secundário a cirurgia <strong>de</strong>ceratotomia radial (RK) ........................................................................... 3 156Lui, Aline Cristina Fioravanti... et al . - Ceratectomia fotorrefrativa(PRK) com mitomicina C a 0,02% para correção <strong>de</strong> grau acentuado<strong>de</strong> astigmatismo hipermetrópico composto secundário a cirurgia <strong>de</strong>ceratotomia radial (RK) ........................................................................... 3 156Lui, Aline Cristina Fioravanti...et al. - Avaliação clínica comparativa<strong>de</strong> lentes progressivas na correção da presbiopia .............................. 3 129Lui, Giovana Arlene Fioravanti... et al .- Ceratectomia fotorrefrativa(PRK) com mitomicina C a 0,02% para correção <strong>de</strong> grau acentuado<strong>de</strong> astigmatismo hipermetrópico composto secundário a cirurgia <strong>de</strong>ceratotomia radial (RK) ........................................................................... 3 156Lui, Giovana Arlene Fioravanti...et al. - Avaliação clínicacomparativa <strong>de</strong> lentes progressivas na correção da presbiopia ......... 3 129Lui, Tatiana Adarli Fioravanti...et al. - Avaliação clínica comparativa<strong>de</strong> lentes progressivas na correção da presbiopia .............................. 3 129ED. PÁG.Macedo, Erick Marcet Santiago <strong>de</strong>...et al. - Imunoterapia tópica notratamento do carcinoma basocelular periocular – relato <strong>de</strong> caso ... 6 355Machado, Marcos <strong>de</strong> Oliveira ...et al. - Prevalência <strong>de</strong> infecção porChlamydia Tracomatis em amostras oculares <strong>de</strong> pacientes comconjuntivite em laboratório <strong>de</strong> genética e biologia molecular naregião metropolitana <strong>de</strong> Florianópolis .................................................. 4 206Maia Junior, Otacílio <strong>de</strong> Oliveira...et al. - Melanocitoma associado àmembrana neovascular subrretiniana ..................................................... 4 237Marback, Eduardo Ferrari... et al. - Melanocitoma associado àmembrana neovascular subrretiniana .................................................... 4 237Marback, Eduardo Ferrari... et al. - Papel da imunoistoquímica nodiagnóstico das alterações oculares na leishmaniose tegumentaramericana. Relato clínico-patológico <strong>de</strong> cinco casos .......................... 3 152Marback, Roberto Lorens... et al. - Papel da imunoistoquímica nodiagnóstico das alterações oculares na leishmaniose tegumentaramericana. Relato clínico-patológico <strong>de</strong> cinco casos .......................... 3 152Marback, Roberto Lorens... et al. - Melanocitoma associado àmembrana neovascular subrretiniana .................................................... 4 237Marback, Roberto Lorens... et al. - Metástase orbital como primeiramanifestação clínica <strong>de</strong> hepatocarcinoma ............................................. 4 245Martinelle, Edmundo Velasco...et al. - Estesiometria corneana póscirurgiafotorrefrativa ............................................................................... 5 271Martins, Felipe Cortizas Ré... et al. - Biometria ultrassônica no cálculodo po<strong>de</strong>r dióptrico <strong>de</strong> lentes intraoculares: estudo comparativo dosmétodos <strong>de</strong> contato e <strong>de</strong> imersão ............................................................. 4 212Maruyama, Aparecida Tapia ... et al. - Percepção dos professores dare<strong>de</strong> regular <strong>de</strong> ensino sobre os problemas visuais e a inclusão <strong>de</strong>alunos com baixa visão ............................................................................... 2 73Massa, Lívio...et al. - Percepção da administração tópica ocular <strong>de</strong>drogas: vaporização x gotas ...................................................................... 6 327Masson, Victor Ferreira...et al. - Comparison between OPD-scanresults and contrast sensitivity of three intraocular lenses: sphericAcrySof SN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Matayoshi, Suzana...et al. - Imunoterapia tópica no tratamento docarcinoma basocelular periocular – relato <strong>de</strong> caso ............................ 6 355Mazurek, Maysa Godoy Gomes...et al. - Perfil do paciente comceratopatia bolhosa pós-facectomia atendidos em hospital público. 4 201Me<strong>de</strong>iros, Hilton Arcover<strong>de</strong> Gonçalves <strong>de</strong>... et al. - Retinopatia <strong>de</strong>Purtscher e Purtscher-like ......................................................................... 2 114Me<strong>de</strong>iros, João Eugenio Gonçalves <strong>de</strong>... et al. - Retinopatia <strong>de</strong>Purtscher e Purtscher-like ......................................................................... 2 114Meirelles, Sergio Henrique Sampaio... et al. - Facectomia na infância:quem são nossos pacientes? ...................................................................... 3 134Meirelles, Sergio Henrique Sampaio...et al - Perfil do paciente comceratopatia bolhosa pós-facectomia atendidos em hospital público. 4 201Melo, Laura Gomes Nunes <strong>de</strong>...et al. - Aspectos atuais no diagnósticodo e<strong>de</strong>ma macular diabético ..................................................................... 1 59Men<strong>de</strong>s, Marcio Henrique... et al. - Estudo comparativo entre imagensultrassonográficas obtidas com sondas <strong>de</strong> 10MHz e 20 MHz naavaliação <strong>de</strong> anormalida<strong>de</strong>s do segmento posterior do globoocular ............................................................................................................. 5 291Memória, Marineuza Rocha... et al. - Evidências obtidas <strong>de</strong> um caso<strong>de</strong> melanoma <strong>de</strong> íris recidivado .............................................................. 1 37Men<strong>de</strong>s Junior, Epaminondas <strong>de</strong> Souza...et al - Metástase orbitalcomo primeira manifestação clínica <strong>de</strong> hepatocarcinoma .................. 4 245Menezes, Maria Elizabeth...et al. - Prevalência <strong>de</strong> infecção porChlamydia Tracomatis em amostras oculares <strong>de</strong> pacientes comconjuntivite em laboratório <strong>de</strong> genética e biologia molecular naregião metropolitana <strong>de</strong> Florianópolis .................................................. 4 206Miyaji, Marcos Enrique... et al. - Biometria ultrassônica no cálculodo po<strong>de</strong>r dióptrico <strong>de</strong> lentes intraoculares: estudo comparativo dosmétodos <strong>de</strong> contato e <strong>de</strong> imersão ............................................................. 4 212Moitinho, Lívia Maria Nossa... et al. - Papel da imunoistoquímica nodiagnóstico das alterações oculares na leishmaniose tegumentaramericana. Relato clínico-patológico <strong>de</strong> cinco casos .......................... 3 152Monica, Luiz Alberto Molina...et al. - Perfil do paciente comceratopatia bolhosa pós-facectomia atendidos em hospital público. . 4 201Rev Bras Oftalmol. 2009; 68 (6): 365-71


368ED. PÁG.Monte, Fernando Queiroz... et al. - Evidências obtidas <strong>de</strong> um caso <strong>de</strong>melanoma <strong>de</strong> íris recidivado .................................................................... 1 37Monteiro, Mário Luiz Ribeiro... et al. - Hipertensão intracranianaidiopática <strong>de</strong> apresentação atípica com papile<strong>de</strong>ma unilateral ....... 3 168Monteiro, Mário Luiz Ribeiro... et al. - Membrana neovascularsubrretiniana justapapilar em paciente com papile<strong>de</strong>ma e hipertensãointracraniana idiopática ............................................................................. 1 42Monteiro, Mário Luiz Ribeiro... et al. - Retinal nerve fiber layer lossdocumented by optical coherence tomography in patients with optictract lesions .................................................................................................. 1 48Monteiro, Mário Luiz Ribeiro... et al. - Síndrome do ápice orbitáriocausada por herpes zóster oftálmico: relato <strong>de</strong> caso e revisão daliteratura ....................................................................................................... 5 304Moraes Júnior, Haroldo Vieira <strong>de</strong>... et al. - Uso <strong>de</strong> ciclosporina 0,05%tópica no tratamento do olho seco <strong>de</strong> pacientes portadores do vírusHIV ................................................................................................................. 2 83Moreira, Marise Amaral Rebouças... et al. - Prolapso <strong>de</strong> gorduraorbitária e oftalmopatia <strong>de</strong> Graves ........................................................ 2 103Moreira, Pedro Bertino ... et al. - Emergências oftalmológicas em umhospital dia ................................................................................................... 4 197Moreira, Pedro Bertino... et al. - Corpo estranho intracristaliniano 2 96Motta, Antonio Francisco Pimenta... et al. - Comparison of centralcorneal e<strong>de</strong>ma and visual recovery between liquefaction andconventional phacoemulsification in soft cataracts ............................. 1 7Motta, Antonio Francisco Pimenta... et al. - Comparison between OPDscanresults and contrast sensitivity of three intraocular lenses:spheric AcrySof SN60AT, aspheric AcrySof SN60WF and multifocalAcrySof Restor lens ................................................................................... 4 216Motta, Mário Martins dos Santos... et al. - Aspectos atuais nodiagnóstico do e<strong>de</strong>ma macular diabético ............................................... 1 59Moura, Fre<strong>de</strong>rico Castelo... et al. - Síndrome do ápice orbitáriocausada por herpes zóster oftálmico: relato <strong>de</strong> caso e revisão daliteratura ....................................................................................................... 5 304Murer, Elizabete Brandão... et al. - Avaliação clínica comparativa <strong>de</strong>lentes progressivas na correção da presbiopia ...................................... 3 129Nakano, Celso Takashi ...et al - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Nakano, Celso Takashi ...et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Nanci, Marcelo... et al. - Tratamento do lagoftalmo paralítico com autilização do implante <strong>de</strong> peso <strong>de</strong> ouro recoberto pela aponeurosedo músculo levantador palpebral ............................................................ 1 30Nascimento, Emília Matos... et al - Uso <strong>de</strong> ciclosporina 0,05% tópicano tratamento do olho seco <strong>de</strong> pacientes portadores do vírus HIV 2 83Navarrete, Carlos Patrício... et al. - Facectomia na infância: quem sãonossos pacientes? ......................................................................................... 3 134Neto, José Beniz... et al. - Endoscopic cyclophotocoagulation inrefractory glaucomas: a long term study ................................................ 3 146Netto, Adamo Lui ...et al. - Avaliação clínica comparativa <strong>de</strong> lentesprogressivas na correção da presbiopia ................................................ 3 129Netto, Adamo Lui... et al. - Ceratectomia fotorrefrativa (PRK) commitomicina C a 0,02% para correção <strong>de</strong> grau acentuado <strong>de</strong>astigmatismo hipermetrópico composto secundário a cirurgia <strong>de</strong>ceratotomia radial (RK) ........................................................................... 3 156Netto, Augusto Adam ... et al. - Avaliação da aplicabilida<strong>de</strong> e docusto da profilaxia da oftalmia neonatal em maternida<strong>de</strong>s da gran<strong>de</strong>Florianópolis ................................................................................................ 5 264Nunes, Juliana dos Santos... et al. - Hipertensão intracranianaidiopática <strong>de</strong> apresentação atípica com papile<strong>de</strong>ma unilateral ....... 3 168Nunes, Juliana dos Santos... et al. - Prevalência da retinopatiadiabética em unida<strong>de</strong> do Programa <strong>de</strong> Saú<strong>de</strong> da Família ................... 2 90Oliveira, Regina Célia Coutinho... et al. - Prevalência da retinopatiadiabética em unida<strong>de</strong> do Programa <strong>de</strong> Saú<strong>de</strong> da Família, ................... 2 90Oliveira, Marcelo ...et al. - Síndrome do ápice orbitário causada porherpes zóster oftálmico: relato <strong>de</strong> caso e revisão da literatura ....... 5 304ED. PÁG.Oréfice, Juliana Lambert... et al. - Avaliação ocular multimodal emdoenças heredodistróficas e <strong>de</strong>generativas da retina ........................ 5 309Pamplona, Mauricio... et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Pamplona, Mauricio... et al. - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Passos, Angelo Ferreira... et al. - Resultados da associaçãotrabeculotomia-trabeculectomia em pacientes não idosos ................ 4 223Paulino, Leonardo Verri...et al. - Fixação iriana <strong>de</strong> lentes <strong>de</strong> câmaraposterior para o tratamento da afacia ...................................................... 5 284Pereira, Basílio <strong>de</strong> Bragança... et al. - Uso <strong>de</strong> ciclosporina 0,05% tópicano tratamento do olho seco <strong>de</strong> pacientes portadores do vírus HIV .... 2 83Pereira, Felipe Bezerra Alves... et al - Importância do exameoftalmológico na doença <strong>de</strong> von Hippel-Lindau ................................... 4 241Pereira, Gustavo Maurílio do Nascimento Garcia... et al. - Prolapso<strong>de</strong> gordura orbitária e oftalmopatia <strong>de</strong> Graves ................................... 2 103Pereira, Fernanda Fernan<strong>de</strong>s... et al. - Melanocitoma associado àmembrana neovascular subrretiniana .................................................... 4 237Pimentel, Sérgio Luis Gianotti... et al. - Membrana neovascularsubrretiniana justapapilar em paciente com papile<strong>de</strong>ma e hipertensãointracraniana idiopática ............................................................................. 1 42Portes, André Luís Freire... et al. - Hipertensão intracranianaidiopática <strong>de</strong> apresentação atípica com papile<strong>de</strong>ma unilateral ....... 3 168Portes, Arlindo José Freire... et al. - Prevalência da retinopatiadiabética em unida<strong>de</strong> do Programa <strong>de</strong> Saú<strong>de</strong> da Família ................... 2 90Portes, Arlindo José Freire...et al. - Percepção da administração tópicaocular <strong>de</strong> drogas: vaporização x gotas ..................................................... 6 327Procianoy, Renato Soibelmann... et al. - Prevalência e fatores <strong>de</strong>risco para a retinopatia da prematurida<strong>de</strong>: estudo com 450 prétermos<strong>de</strong> muito baixo peso ....................................................................... 1 22Ramos, Carolina do Val Ferreira ... et al. - Hipertensão intracranianaidiopática <strong>de</strong> apresentação atípica com papile<strong>de</strong>ma unilateral ....... 3 168Ramos, Régia Maria Gondim... et al. - Importância do exameoftalmológico na doença <strong>de</strong> von Hippel-Lindau ................................... 4 241Reh<strong>de</strong>r, José Ricardo Carvalho Lima... et al. - Biometria ultrassônicano cálculo do po<strong>de</strong>r dióptrico <strong>de</strong> lentes intraoculares: estudocomparativo dos métodos <strong>de</strong> contato e <strong>de</strong> imersão ............................. 4 212Reh<strong>de</strong>r, Jose Ricardo Carvalho Lima... et al. - Estesiometria corneanapós-cirurgia fotorrefrativa ......................................................................... 5 271Reh<strong>de</strong>r, Jose Ricardo Carvalho Lima... et al. - Fixação iriana <strong>de</strong> lentes<strong>de</strong> câmara posterior para o tratamento da afacia .................................. 5 284Reh<strong>de</strong>r, José Ricardo Lima... et al. - Percepção dos professores dare<strong>de</strong> regular <strong>de</strong> ensino sobre os problemas visuais e a inclusão <strong>de</strong>alunos com baixa visão ............................................................................... 2 73Reis, Alexandre Reis... et al. - Comparison of central corneal e<strong>de</strong>maand visual recovery between liquefaction and conventionalphacoemulsification in soft cataracts ..................................................... 1 7Reis, Alexandre... et al. - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Rezen<strong>de</strong>, Flavio... et al. - Troca do cristalino com finalida<strong>de</strong> refrativa(TCR) ............................................................................................................. 3 180Ribeiro, Geraldo <strong>de</strong> Barros... et al. - Estudo comparativo da ação datoxina botulínica tipo A e da crotoxina sobre as células satélites damusculatura extrínseca ocular em mo<strong>de</strong>lo animal ............................... 5 296Rolim, Márjorie Sabino Façanha Barreto... et al - Evidências obtidas<strong>de</strong> um caso <strong>de</strong> melanoma <strong>de</strong> íris recidivado .......................................... 1 37Sampaio, Paulo Ricardo Souza... et al. - Percepção dos professoresda re<strong>de</strong> regular <strong>de</strong> ensino sobre os problemas visuais e a inclusão <strong>de</strong>alunos com baixa visão ............................................................................... 2 73Santhiago, Marcony Rodrigues <strong>de</strong> ... et al. - Tendências evolutivasdos cirurgiões <strong>de</strong> catarata presentes no IV Congresso Brasileiro <strong>de</strong>Catarata e Cirurgia Refrativa .................................................................. 1 13Rev Bras Oftalmol. 2009; 68 (6): 365-71


369ED. PÁG.Santhiago, Marcony Rodrigues <strong>de</strong>... et al. - Facectomia na infância:quem são nossos pacientes? ...................................................................... 3 134Santhiago, Marcony Rodrigues <strong>de</strong>... et al. - Lentes asféricas: avaliaçãoda indicação clínica e das opções <strong>de</strong> lentes ............................................. 3 175Santhiago, Marcony Rodrigues <strong>de</strong>... et al. - Perfil do paciente comceratopatia bolhosa pós-facectomia atendidos em hospital público. 4 201Santhiago, Marcony... et al. - Alterações na tela <strong>de</strong> Amsler entrepacientes com catarata senil ..................................................................... 1 18Santos, Vagner Rogério dos ... et al - Avaliação <strong>de</strong> Sistema <strong>de</strong> LeituraPortátil (SLP) para baixa visão <strong>de</strong>senvolvido no Brasil .................... 5 259Sardinha, Mariluze... et al. - Metástase orbital como primeiramanifestação clínica <strong>de</strong> hepatocarcinoma ............................................. 4 245Schor, Paulo...et al. - Avaliação <strong>de</strong> Sistema <strong>de</strong> Leitura Portátil (SLP)para baixa visão <strong>de</strong>senvolvido no Brasil ............................................... 5 259Sebastiá, Roberto... et al. - Tratamento do lagoftalmo paralítico coma utilização do implante <strong>de</strong> peso <strong>de</strong> ouro recoberto pela aponeurosedo músculo levantador palpebral ............................................................ 1 30Shato, Chow Wang Ming... et al. - Avaliação clínica comparativa <strong>de</strong>lentes progressivas na correção da presbiopia .................................... 3 129Silva, Carlos Henrique Reis <strong>de</strong> Araújo...et al. - Estudo comparativoda ação da toxina botulínica tipo A e da crotoxina sobre as célulassatélites da musculatura extrínseca ocular em mo<strong>de</strong>lo animal ........ 5 296Silva, Maria Rosa Bet <strong>de</strong> Moraes... et al. - O Ensino da <strong>Oftalmologia</strong>3 127Silva, Noêmia Peixoto da... et al. - Facectomia na infância: quem sãonossos pacientes? ........................................................................................ 3 134Silva, Renata Siqueira da... et al. - Hipertensão ocular “mascarada”por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da catarata: relato <strong>de</strong> caso ........ 6 348Silva, Felício Aristóteles da... et al. - Maculopatia tóxica porcloroquina ..................................................................................................... 3 161Silva, Jaquison Furtado da... et al. - Retinopatia <strong>de</strong> Purtscher ePurtscher-like .............................................................................................. 2 114Silva, Maria Rosa Bet <strong>de</strong> Moraes ... et al - Estudo do comportamentoda PIO <strong>de</strong> 24 horas e frequência <strong>de</strong> glaucoma em pacientes comsíndrome da apnéia obstrutiva do sono .................................................. 6 338Silva, Nikias Alves da... et al. - Maculopatia tóxica por cloroquina 3 161Siqueira, Rubens Camargo... et al. - O uso <strong>de</strong> células-tronco naoftalmologia .................................................................................................. 2 71Soares, Eduardo Jorge Carneiro... et al.- Entrópio congênito primárioda pálpebra superior .................................................................................. 1 53Soares, Ícaro Perez ... et al. - Entrópio congênito primário da pálpebrasuperior ......................................................................................................... 1 53Solari, Helena Parente... et al. - ‘Crosslinking’ <strong>de</strong> colágeno notratamento do ceratocone .......................................................................... 6 359Souza-Dias, Carlos Ramos <strong>de</strong>... et al. - New consi<strong>de</strong>rations aboutDuane’s syndrome ...................................................................................... 2 107ED. PÁG.Sugano, Debora Mayumi... et al. - Função visual <strong>de</strong> criançaspseudofácicas por catarata infantil ......................................................... 5 278Tarcha, Fernando Antonio Gualiardo... et al. - Estesiometria corneanapós-cirurgia fotorrefrativa ....................................................................... 5 271Teixeira, Kim-Ir-Sen Santos ... et al. - Prolapso <strong>de</strong> gordura orbitáriae oftalmopatia <strong>de</strong> Graves .......................................................................... 2 103Toscano, Daniela... et al. - Endoscopic cyclophotocoagulation inrefractory glaucomas: a long term study ................................................ 3 146Traebert, Jefferson... et al.- Prevalência <strong>de</strong> infecção por Chlamydiatracomatis em amostras oculares <strong>de</strong> pacientes com conjuntivite emlaboratório <strong>de</strong> genética e biologia molecular na regiãometropolitana <strong>de</strong> Florianópolis ................................................................ 4 206Tomimatsu, Melissa Megumi ... et al. - Avaliação da microbiotaocular em pacientes com disfunção do filme lacrimal. ........................ 6 332Uras, Ricardo... et al. - Avaliação <strong>de</strong> Sistema <strong>de</strong> Leitura Portátil (SLP)para Baixa Visão Desenvolvido no Brasil ............................................. 5 259Valbon, Bruno <strong>de</strong> Freitas... et al. - Hipertensão ocular “mascarada”por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgia da Catarata .................................. 6 348Val<strong>de</strong>taro, Renata ... et al. - Hipertensão intracraniana idiopática <strong>de</strong>apresentação atípica com papile<strong>de</strong>ma unilateral ................................ 3 168Valiatti, Fabiana Borba ... et al. - Prevalência e fatores <strong>de</strong> risco paraa retinopatia da prematurida<strong>de</strong>: estudo com 450 pré-termos <strong>de</strong> muitobaixo peso ..................................................................................................... 1 22Varandas, Vinicius da Silva... et al. - Tendências evolutivas doscirurgiões <strong>de</strong> catarata presentes no IV Congresso Brasileiro <strong>de</strong>Catarata e Cirurgia Refrativa .................................................................. 1 13Vianna, Raul N. G - <strong>Nov</strong>os horizontes ................................................... 1 5Vitiello, Vicente...et al. - Estesiometria corneana pós cirurgiafotorrefrativa ............................................................................................... 5 271Weber, Silke Anna Theresa ...et al. - Estudo do comportamento daPIO <strong>de</strong> 24 horas e freqüência <strong>de</strong> glaucoma em pacientes com síndromeda apnéia obstrutiva do sono .................................................................... 6 338Yamane, Iris... et al - Alterações na tela <strong>de</strong> Amsler entre pacientescom catarata senil ....................................................................................... 1 18Yamane, Iris <strong>de</strong> Souza...et al - Comparison between OPD-scan resultsand contrast sensitivity of three intraocular lenses: spheric AcrySofSN60AT, aspheric AcrySof SN60WF and multifocal AcrySofRestor lens .................................................................................................... 4 216Yamane, Iris... et al - Comparison of central corneal e<strong>de</strong>ma and visualrecovery between liquefaction and conventionalphacoemulsification in soft cataracts ...................................................... 1 7Yamane, Yoshifume... et al - Facectomia na infância: quem são nossospacientes? ..................................................................................................... 3 134Yamane, Yoshifume ... et al. - Perfil do paciente com ceratopatia bolhosapós-facectomia atendidos em hospital público ...................................... 4 201Yu, Cecília Zorat ... et al - Avaliação da microbiota ocular em pacientescom disfunção do filme lacrimal ............................................................... 6 332AssuntoED. PÁG.Artigo <strong>de</strong> RevisãoAspectos atuais no diagnóstico do e<strong>de</strong>ma macular diabético. MárioMartins dos Santos Motta, Jacqueline Coblentz, Laura GomesNunes <strong>de</strong> Melo .............................................................................................. 1 59New consi<strong>de</strong>rations about Duane’s syndrome. Carlos Ramos <strong>de</strong>Souza-Dias .................................................................................................... 2 107Retinopatia <strong>de</strong> Purtscher e Purtscher-like. Hilton Arcover<strong>de</strong>Gonçalves <strong>de</strong> Me<strong>de</strong>iros, João Eugenio Gonçalves <strong>de</strong> Me<strong>de</strong>iros,Larissa Casteluber Caliari, Jaquison Furtado da Silva ....................... 2 114Lentes asféricas: avaliação da indicação clínica e das opções <strong>de</strong>lentes. Newton Kara-Jose Junior, Marcony Rodrigues <strong>de</strong> Santhiago ... 3 175Troca do cristalino com finalida<strong>de</strong> refrativa (TCR). Flavio Rezen<strong>de</strong>,Renata Rezen<strong>de</strong> Bisol, Tiago Bisol ........................................................ 3 180Síndrome do ápice orbitário causada por herpes zóster oftálmico:relato <strong>de</strong> caso e revisão da literatura. Kenzo Hokazono, MarceloOliveira, Fre<strong>de</strong>rico Castelo Moura, Mário Luiz Ribeiro Monteiro ...... 5 304ED. PÁG.Avaliação ocular multimodal em doenças heredodistróficas e<strong>de</strong>generativas da retina. Daniela Cavalcanti Ferrara, DanielaCalucci, Juliana Lambert Oréfice, Rogério Alves Costa .......................... 5 309Crosslinking <strong>de</strong> colágeno no tratamento do Ceratocone. RodrigoCoelho Amaral, Helena Parente Solari ................................................. 6 359CatarataComparison of central corneal e<strong>de</strong>ma and visual recovery betweenliquefaction and conventional phacoemulsification in soft cataractsCelso Takashi Nakano,Wilson Takashi Hida, Newton Kara-JoseJunior, Antonio Francisco Pimenta Motta, Alexandre Reis, MauricioPamplona, Reinaldo Fujita, Iris Yamane, Ricardo Holzchuh,Amaryllis Avakian ..................................................................................... 1 7Tendências evolutivas dos cirurgiões <strong>de</strong> catarata presentes no IVCongresso Brasileiro <strong>de</strong> Catarata e Cirurgia Refrativa. MarconyRodrigues <strong>de</strong> Santhiago, Beatriz <strong>de</strong> Abreu Fiuza Gomes, FernandaFerreira Pires Gaffree, Vinicius da Silva Varandas, Adroaldo <strong>de</strong>Alencar Costa Filho .................................................................................... 1 13Rev Bras Oftalmol. 2009; 68 (6): 365-71


370Alterações na tela <strong>de</strong> Amsler entre pacientes com catarata senil.Newton Kara-Junior, Wilson Takashi Hida, Marcony Santhiago, IrisYamane, Pedro Carlos Carricondo, Newton Kara-Jose ....................... 1 18A neutralização do astigmatismo corneano durante a cirurgia dacatarata pormeio <strong>de</strong> lente intraocular tórica: resultados. VirgilioCenturion, Augusto Cézar Lacava, Juan Carlos Caballero ................ 2 76Corpo estranho intracristaliniano. Joyce Treinta Dalfré, AnaCarolina Igreja Leonor, Pedro Bertino Moreira, Osmar AntônioGaiotto Júnior .............................................................................................. 2 96Facectomia na infância: quem são nossos pacientes? MarconyRodrigues <strong>de</strong> Santhiago, Beatriz <strong>de</strong> Abreu Fiúza Gomes, NewtonKara-José Junior, Noêmia Peixoto da Silva, Carlos PatrícioNavarrete, Armando Stefano Crema, Yoshifume Yamane,Sergio Henrique Sampaio Meirelles ...................................................... 3 134Troca do cristalino com finalida<strong>de</strong> refrativa (TCR). Flavio Rezen<strong>de</strong>,Renata Rezen<strong>de</strong> Bisol, Tiago Bisol ........................................................ 3 180Biometria ultrassônica no cálculo do po<strong>de</strong>r dióptrico <strong>de</strong> lentesintraoculares: estudo comparativo dos métodos <strong>de</strong> contato e <strong>de</strong>imersão. Felipe Cortizas Ré Martins, Marcos Enrique Miyaji, VagnerLoduca Lima, José Ricardo Carvalho Lima Reh<strong>de</strong>r ............................ 4 212Comparison between OPD-scan results and contrast sensitivity ofthree intraocular lenses: spheric AcrySof SN60AT, aspheric AcrySofSN60WF and multifocal AcrySof Restor lens. Celso Takashi Nakano,Wilson Takashi Hida, Newton Kara-Jose Junior, Antonio FranciscoPimentaMotta, Danilo Fante, Victor Ferreira Masson, AlexandreReis, Mauricio Pamplona, Iris <strong>de</strong> Souza Yamane, Ricardo Holzchuh,Amaryllis Avakian ..................................................................................... 4 216Função visual <strong>de</strong> crianças pseudofácicas por catarata infantil. Patríciada Rocha Pitta Ferraz, Debora Mayumi Sugano, Celso LopezFernan<strong>de</strong>s ..................................................................................................... 5 278Fixação iriana <strong>de</strong> lentes <strong>de</strong> câmara posterior para o tratamento daafacia. Ana Luiza Lise Ferreira, Leonardo Verri Paulino, JoseRicardo Carvalho Lima Reh<strong>de</strong>r ............................................................... 5 284Síndrome do bloqueio capsular precoce relato <strong>de</strong> caso e especulaçãosobre o tamanho da parte óptica da lente como fator <strong>de</strong> risco. EduardoF. Marback , Rita <strong>de</strong> Cássia Aquino <strong>de</strong> Araújo, Marcelo Siqueira <strong>de</strong>Freitas ............................................................................................................ 6 334Hipertensão ocular “mascarada” por e<strong>de</strong>ma <strong>de</strong> córnea após cirurgiada catarata: relato <strong>de</strong> caso. Bruno <strong>de</strong> Freitas Valbon, Fre<strong>de</strong>ricoGuerra, Renata Siqueira da Silva, Ana LauraCanedo; Renato Ambrósio Junior .......................................................... 6 348ConjuntivaPrevalência <strong>de</strong> infecção por Chlamydia Tracomatis em amostrasoculares <strong>de</strong> pacientes com conjuntivite em laboratório <strong>de</strong> genéticae biologia molecular na região metropolitana <strong>de</strong> Florianópolis.Marcos <strong>de</strong> Oliveira Machado, Diego <strong>de</strong> Souza Fraga, João Fernan<strong>de</strong>sFloriano, Maria Elizabeth Menezes, Jefferson Traebert .................... 4 206Avaliação da aplicabilida<strong>de</strong> e do custo da profilaxia da oftalmianeonatal em maternida<strong>de</strong>s da gran<strong>de</strong> Florianópolis. Augusto AdamNetto, Merry Elizabeth Goe<strong>de</strong>rt .............................................................. 5 264Percepção da administração tópica ocular <strong>de</strong> drogas: vaporização xgotas. Arlindo José Freire Portes, Louise Pellegrino Gomes, BeatrizLopes Moura Brasil do Amaral, Lívio Massa ...................................... 6 327Avaliação da microbiota ocular em pacientes com disfunção do filmelacrimal. Melissa Megumi Tomimatsu, Manuela Maria ValençaCor<strong>de</strong>iro Barbosa, Cecília Zorat Yu, Flavio Eduardo Hirai, Ana LuisaHofling-Lima ................................................................................................ 6 332CórneaUso <strong>de</strong> ciclosporina 0,05% tópica no tratamento do olho seco <strong>de</strong>pacientes portadores do vírus HIV. Rodrigo <strong>de</strong> Pinho Paes Barreto,Ana Luiza Biancardi, Emília Matos Nascimento, Basílio <strong>de</strong> BragançaPereira, Haroldo Vieira <strong>de</strong> Moraes Jr .................................................... 2 83Tratamento aditivo do ceratocone por ‘crosslinking’ do colágenoapós implante <strong>de</strong> anel <strong>de</strong> Ferrara. Edna Almodin, Steve Arschinoff,Juliana Almodin, Paulo Ferrara ............................................................... 3 138Ceratectomia fotorrefrativa (PRK) com mitomicina C a 0,02% paracorreção <strong>de</strong> grau acentuado <strong>de</strong> astigmatismo hipermetrópicocomposto secundário a cirurgia <strong>de</strong> ceratotomia radial (RK) ........... 3 156Perfil do paciente com ceratopatia bolhosa pós-facectomia atendidosem hospital público. Marcony Rodrigues <strong>de</strong> Santhiago, Luiz AlbertoMolina Monica, Newton Kara-Junior, Beatriz <strong>de</strong> Abreu, Fiúza Gomes,Pedro Moreira Bertino, Maysa Godoy Gomes Mazurek, YoshifumeYamane,Sergio Henrique Sampaio Meirelles ...................................... 4 201Estesiometria corneana pós-cirurgia fotorrefrativa. AlessandroPerussi Garcia, Fernando Antonio Gualiardo Tarcha, VicenteVitiello Neto, Edmundo Velasco Martinelle, Jose Ricardo CarvalhoLima Reh<strong>de</strong>r ................................................................................................. 5 271‘Crosslinking’ <strong>de</strong> colágeno no tratamento do ceratocone.RodrigoCoelho Amaral, Helena Parente Solari ................................................. 6 359EditorialRevista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>: novos horizontes. Raul N. G.Vianna ........................................................................................................... 1 5O uso <strong>de</strong> células-tronco na oftalmologia. Rubens C. Siqueira ........... 2 71O Ensino da <strong>Oftalmologia</strong>. Maria Rosa Bet <strong>de</strong> Moraes Silva ............ 3 127<strong>Nov</strong>ida<strong>de</strong>s na cirurgia <strong>de</strong> catarata: lentes intraoculares asféricas.Newton Kara-José Junior .......................................................................... 4 195Excelência em cirurgia <strong>de</strong> cristalino. Virgilio Centurion .................. 5 257Como (ainda) ser feliz na profissão. Francisco Valter da Justa Freitas .. 6 325EnsinoPercepção dos professores da re<strong>de</strong> regular <strong>de</strong> ensino sobre osproblemas visuais e a inclusão <strong>de</strong> alunos com baixa visão. AparecidaTapia Maruyama, Paulo Ricardo Souza Sampaio, José Ricardo LimaReh<strong>de</strong>r ........................................................................................................... 2 73Ensino <strong>de</strong> oftalmologia na graduação médica. Estudo comparativo<strong>de</strong> aprendizado na oftalmoscopia direta com oftalmoscópioconvencional e <strong>de</strong> campo amplo (Panoptic). Eduardo <strong>de</strong> FrançaDamasceno, Nadyr Antonia Pereira Damasceno, Adroaldo <strong>de</strong>Alencar Costa Filho .................................................................................... 4 231Epi<strong>de</strong>miologiaPapel da imunoistoquímica no diagnóstico das alterações ocularesna leishmaniose tegumentar americana. Relato clínico-patológico<strong>de</strong> cinco casos. Lívia Maria Nossa Moitinho, Luiz Antônio Rodrigues<strong>de</strong> Freitas, Eduardo Ferrari Marback, Roberto Lorens Marback .... 3 152Emergências oftalmológicas em um hospital dia. Ana Carolina IgrejaLeonor, Joyce Treinta Dalfré, Pedro Bertino Moreira, Osmar AntônioGaiotto Júnior .............................................................................................. 4 197EstrabismoNew consi<strong>de</strong>rations about Duane’s syndrome. Carlos Ramos <strong>de</strong>Souza-Dias .................................................................................................... 2 107Estudo comparativo da ação da toxina botulínica tipo A e dacrotoxinasobre as células satélites da musculatura extrínsecaocularem mo<strong>de</strong>lo animal. Marta Halfeld Ferrari Alves Lacordia,Geraldo <strong>de</strong> Barros Ribeiro, Hen<strong>de</strong>rson Celestino <strong>de</strong> Almeida, CarlosHenrique Reis <strong>de</strong> Araújo Silva, Maria do CarmoJordão Coelho, RaulFernando Binato Lamim ............................................................................ 5 296GlaucomaEndoscopic cyclophotocoagulation in refractory glaucomas: a longterm study. Francisco Eduardo Lima, José Beniz Neto, DanielaToscano, Durval Moraes <strong>de</strong> Carvalho, Marcos Pereira <strong>de</strong> Ávila .... 3 146Resultados da associação trabeculotomia-trabeculectomia empacientes não idosos. Angelo Ferreira Passos, Kélcia Kiefer, RodrigoCarvalho Amador ....................................................................................... 4 223Estudo do comportamento da PIO <strong>de</strong> 24 horas e frequência <strong>de</strong>glaucoma em pacientes com síndrome da apnéia obstrutiva do sono.Maria Rosa Bet <strong>de</strong> Moraes Silva, Silke Anna Theresa Weber ......... 6 338Neuro-oftalmologiaRetinal nerve fiber layer loss documented by optical coherencetomography in patients with optic tract lesions. Mário Luiz RibeiroMonteiro, Kenzo Hokazone ....................................................................... 1 48Hipertensão intracraniana idiopática <strong>de</strong> apresentação atípica compapile<strong>de</strong>ma unilateral. André Luís Freire Portes, Carolina do ValFerreira Ramos, Juliana dos Santos Nunes, Renata Val<strong>de</strong>taro, MárioLuiz Ribeiro Monteiro ............................................................................... 3 168Órbita / Plástica OcularTratamento do lagoftalmo paralítico com a utilização do implante <strong>de</strong>peso <strong>de</strong> ouro recoberto pela aponeurose do músculo levantadorpalpebral. Sergio Lessa, Marcelo Nanci, Eduardo Flores, RobertoSebastiá ......................................................................................................... 1 30Entrópio congênito primário da pálpebra superior. Taliana FreitasBernar<strong>de</strong>s, Ícaro Perez Soares, Valenio Perez França, Eduardo JorgeCarneiro Soares .......................................................................................... 1 53Rev Bras Oftalmol. 2009; 68 (6): 365-71


371Prolapso <strong>de</strong> gordura orbitária e oftalmopatia <strong>de</strong> Graves. Kim-Ir-Sen Santos Teixeira, Rachel Campêlo Feres, Gustavo Maurílio doNascimento Garcia Pereira, Marise Amaral Rebouças Moreira,Dorislay Barbosa <strong>de</strong> Sousa Camargo Andra<strong>de</strong> .................................... 2 103Síndrome do ápice orbitário causada por herpes zóster oftálmico:relato <strong>de</strong> caso e revisão da literatura. Kenzo Hokazono, MarceloOliveira, Fre<strong>de</strong>rico Castelo Moura, Mário Luiz Ribeiro Monteiro . 5 304RefraçãoAvaliação clínica comparativa <strong>de</strong> lentes progressivas na correçãoda presbiopia. Adamo Lui Netto, Milton Ruiz Alves, Aline CristinaFioravanti Lui, Giovana Arlene Fioravanti Lui, Renato GiovediFilho, Tatiana Adarli Fioravanti Lui, Elizabete Brandão Murer, ChowWang Ming Shato ......................................................................................... 3 129Lentes asféricas: avaliação da indicação clínica e das opções <strong>de</strong>lentes. Newton Kara-Jose Junior, Marcony Rodrigues <strong>de</strong> Santhiago ... 3 175Avaliação <strong>de</strong> Sistema <strong>de</strong> Leitura Portátil (SLP) para Baixa VisãoDesenvolvido no Brasil. Vagner Rogério dos Santos, Eliana CunhaLima, Adriana Berezovsky, Paulo Schor, Ricardo Uras, RubensBelfort Junior ............................................................................................... 5 259RetinaPrevalência e fatores <strong>de</strong> risco para a retinopatia da prematurida<strong>de</strong>:estudo com 450 pré-termos <strong>de</strong> muito baixo peso. João Borges FortesFilho, Gabriela Unchalo Eckert, Fabiana Borba Valiatti, MarleneCoelho da Costa, Pedro Paulo Bonomo, Renato Soibelmann Procianoy .... 1 22Membrana neovascular subrretiniana justapapilar em pacientecompapile<strong>de</strong>ma e hipertensão intracraniana idiopática. Mário LuizRibeiro Monteiro, Martha <strong>de</strong> Queiroz Monteiro Jales, Sérgio LuisGianotti Pimentel ........................................................................................ 1 42Aspectos atuais no diagnóstico do e<strong>de</strong>ma macular diabético. MárioMartins dos Santos Motta, Jacqueline Coblentz, Laura Gomes Nunes<strong>de</strong> Melo .......................................................................................................... 1 59Prevalência da retinopatia diabética em unida<strong>de</strong> do Programa <strong>de</strong>Saú<strong>de</strong> da Família. Murielem Fernan<strong>de</strong>s Gue<strong>de</strong>s, Arlindo José FreirePortes, Abelardo <strong>de</strong> Souza Couto Junior, Juliana dos Santos Nunes,Regina Célia Coutinho Oliveira .............................................................. 2 90Antiphospholipid syndrome and retinal vein occlusion. Alinne MariaCamargos da Costa, Homero Gusmão <strong>de</strong> Almeida, ChristianMarcellus <strong>de</strong> Camargo Campos, Roberto Martins Gonçalves ........... 2 100Retinopatia <strong>de</strong> Purtscher e Purtscher-like. Hilton Arcover<strong>de</strong>Gonçalves <strong>de</strong> Me<strong>de</strong>iros, João Eugenio Gonçalves <strong>de</strong>Me<strong>de</strong>iros,Larissa Casteluber Caliari, Jaquison Furtado da Silva .... 2 114Maculopatia tóxica por cloroquina. Nikias Alves da Silva, FelícioAristóteles da Silva .................................................................................... 3 161Importância do exame oftalmológico na doença <strong>de</strong> von Hippel-Lindau. Ricardo Evangelista Marrocos <strong>de</strong> Aragão, Iêda MariaAlexandre Barreira, Andreya Ferreira Rodrigues Bezerra, RégiaMaria Gondim Ramos, Felipe Bezerra Alves Pereira ........................ 4 241Estudo comparativo entre imagens ultrassonográficas obtidas comsondas <strong>de</strong> 10MHz e 20 MHz na avaliação <strong>de</strong> anormalida<strong>de</strong>s dosegmento posterior do globo ocular. Marcio Henrique Men<strong>de</strong>s,Alberto Jorge Betinjane, Adhele Furlani <strong>de</strong> Sá Cavalcante, VeraRegina Cardoso Castanheira, Cheng Te Cheng, José Carlos Eu<strong>de</strong>sCarani ............................................................................................................ 5 291Avaliação ocular multimodal em doenças heredodistróficas e<strong>de</strong>generativas da retina. Daniela Cavalcanti Ferrara, DanielaCalucci, Juliana Lambert Oréfice, Rogério Alves Costa ................... 5 309TumoresEvidências obtidas <strong>de</strong> um caso <strong>de</strong> melanoma <strong>de</strong> íris recidivado.Juliana <strong>de</strong> Lucena Martins Ferreira, Márjorie Sabino FaçanhaBarreto Rolim, Cícero Narciso Moreira Leite, Fernando QueirozMonte, Marineuza Rocha Memória ......................................................... 1 37Melanocitoma associado à membrana neovascular subrretiniana.Eduardo Ferrari Marback, Fernanda Fernan<strong>de</strong>s Pereira, CláudiaGalvão, Otacílio <strong>de</strong> Oliveira Maia Jr, Roberto Lorens Marback ..... 4 237Metástase orbital como primeira manifestação clínica <strong>de</strong>hepatocarcinoma. Mariluze Sardinha, Epaminondas <strong>de</strong> Souza Men<strong>de</strong>sJunior, Juliana Cabral Duarte Brandão, Paulo Roberto FontesAthanázio, Roberto Lorens Marback .................................................... 4 245Imunoterapia tópica no tratamento do carcinoma basocelularperiocular – relato <strong>de</strong> caso. Erick Marcet Santiago <strong>de</strong> Macedo,Rachel Camargo Carneiro, Suzana Matayoshi ..................................... 6 355Rev Bras Oftalmol. 2009; 68 (6): 365-71


372Instruções aos autoresA Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> (Rev Bras Oftalmol.) -ISSN 0034-7280, publicação científica da <strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong><strong>de</strong> <strong>Oftalmologia</strong>, se propõe a divulgar artigos que contribuampara o aperfeiçoamento e o <strong>de</strong>senvolvimento da prática,da pesquisa e do ensino da <strong>Oftalmologia</strong> e <strong>de</strong> especialida<strong>de</strong>safins. Todos os manuscritos, após aprovação pelosEditores, serão avaliados por dois ou três revisores qualificados(peer review), sendo o anonimato garantido em todo oprocesso <strong>de</strong> julgamento. Os comentários dos revisores serão<strong>de</strong>volvidos aos autores para modificações no texto ou justificativa<strong>de</strong> sua conservação. Somente após aprovações finaisdos revisores e editores, os manuscritos serão encaminhadospara publicação. O manuscrito aceito para publicação passaráa ser proprieda<strong>de</strong> da Revista e não po<strong>de</strong>rá ser editado, totalou parcialmente, por qualquer outro meio <strong>de</strong> divulgação, sema prévia autorização por escrito emitida pelo Editor Chefe. Osartigos que não apresentarem mérito, que contenham errossignificativos <strong>de</strong> metodologia, ou não se enquadrem na políticaeditorial da revista, serão rejeitados não cabendo recurso.Os artigos publicados na Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>seguem os requisitos uniformes proposto pelo ComitêInternacional <strong>de</strong> Editores <strong>de</strong> Revistas Médicas, atualizado emfevereiro <strong>de</strong> 2006 e disponível no en<strong>de</strong>reço eletrônico http://www.icmje.orgAPRESENTAÇÃO E SUBMISSÃO DOS MANUSCRITOSO artigo enviado <strong>de</strong>verá ser acompanhado <strong>de</strong> carta assinadapor todos os autores, autorizando sua publicação, <strong>de</strong>clarandoque o mesmo é inédito e que não foi, ou está sendosubmetido à publicação em outro periódico.A esta carta <strong>de</strong>vem ser anexados:• Declaração <strong>de</strong> Conflitos <strong>de</strong> Interesse, quando pertinente.A Declaração <strong>de</strong> Conflitos <strong>de</strong> Interesses, segundo Resoluçãodo Conselho Fe<strong>de</strong>ral <strong>de</strong> Medicina nº 1595/2000, vedaque em artigo científico seja feita promoção ou propaganda<strong>de</strong> quaisquer produtos ou equipamentos comerciais;• Certificado <strong>de</strong> Aprovação do Trabalho pela Comissão<strong>de</strong> Ética em Pesquisa da Instituição em que o mesmo foi realizado;• Informações sobre eventuais fontes <strong>de</strong> financiamentoda pesquisa;• Artigo que trata <strong>de</strong> pesquisa clínica com seres humanos<strong>de</strong>ve incluir a <strong>de</strong>claração <strong>de</strong> que os participantes assinaramTermo <strong>de</strong> Consentimento Livre Informado.Todas as pesquisas, tanto as clínicas como as experimentais,<strong>de</strong>vem ter sido executadas <strong>de</strong> acordo com a Declaração<strong>de</strong> Helsinki.A Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> não endossa a opiniãodos autores, eximindo-se <strong>de</strong> qualquer responsabilida<strong>de</strong>em relação a matérias assinadas.Os artigos po<strong>de</strong>m ser escritos em português, espanhol,inglês ou francês.A Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> recebe para publicação:Artigos Originais <strong>de</strong> pesquisa básica, experimentaçãoclínica ou cirúrgica; Divulgação e condutas em casos clínicos<strong>de</strong> relevante importância; Revisões <strong>de</strong> temas específicos, Atualizações;Cartas ao editor. Os Editoriais serão escritos a convite,apresentando comentários <strong>de</strong> trabalhos relevantes daprópria revista, pesquisas importantes publicadas ou comunicaçõesdos editores <strong>de</strong> interesse para a especialida<strong>de</strong>. Artigoscom objetivos comerciais ou propagandísticos serão recusados.Os manuscritos <strong>de</strong>verão obe<strong>de</strong>cer as seguintes estruturas:Artigo Original: Descreve pesquisa experimental ou investigaçãoclínica - prospectiva ou retrospectiva, randomizadaou duplo cego. Deve ter: Título em português e inglês, Resumoestruturado, Descritores; Abstract, Keywords, Introdução,Métodos, Resultados, Discussão, Conclusão e Referências.Artigo <strong>de</strong> Revisão: Tem como finalida<strong>de</strong> examinar a bibliografiapublicada sobre um <strong>de</strong>terminado assunto, fazendouma avaliação crítica e sistematizada da literatura sobre um<strong>de</strong>terminado tema e apresentar as conclusões importantes,baseadas nessa literatura. Somente serão aceitos para publicaçãoquando solicitado pelos Editores. Deve ter: Texto, Resumo,Descritores, Título em Inglês, Abstract, Keywords eReferências.Artigo <strong>de</strong> Atualização: Revisões do estado-da-arte sobre<strong>de</strong>terminado tema, escrito por especialista a convite dos Editores.Deve ter: Texto, Resumo, Descritores, Título em Inglês,Abstract, Keywords e Referências.Relato <strong>de</strong> Caso: Deve ser informativo e não <strong>de</strong>ve conter<strong>de</strong>talhes irrelevantes. Só serão aceitos os relatos <strong>de</strong> casos clínicos<strong>de</strong> relevada importância, quer pela rarida<strong>de</strong> como entida<strong>de</strong>nosológica, quer pela não usual forma <strong>de</strong> apresentação.Deve ter: Introdução, Descrição objetiva do caso, Discussão,Resumo, Descritores, Título em Inglês, Abstract eKeywords e Referências.Cartas ao Editor: Têm por objetivo comentar ou discutirtrabalhos publicados na revista ou relatar pesquisas originaisem andamento. Serão publicadas a critério dos Editores, coma respectiva réplica quando pertinente.Preparo do Manuscrito:A) Folha <strong>de</strong> Rosto <strong>de</strong>verá conter:• Título do artigo, em português e inglês, contendo entre<strong>de</strong>z e doze palavras, sem consi<strong>de</strong>rar artigos e preposições. OTítulo <strong>de</strong>ve ser motivador e <strong>de</strong>ve dar idéia dos objetivos e doconteúdo do trabalho;• Nome completo <strong>de</strong> cada autor, sem abreviaturas, porém,se o autor já possui um formato utilizado em suas publicações,<strong>de</strong>ve informar à secretaria da revista;• Indicação do grau acadêmico e/ou função acadêmicae a afiliação institucional <strong>de</strong> cada autor, separadamente. Sehouver mais <strong>de</strong> uma afiliação institucional, indicar apenas amais relevante. Cargos e/ou funções administrativas não <strong>de</strong>vemser indicadas.• Indicação da Instituição on<strong>de</strong> o trabalho foi realizado;• Nome, en<strong>de</strong>reço, fax e e-mail do autor correspon<strong>de</strong>nte;• Fontes <strong>de</strong> auxílio à pesquisa, se houver;• Declaração <strong>de</strong> inexistência <strong>de</strong> conflitos <strong>de</strong> interesse.B) Segunda folhaResumo e Descritores: Resumo, em português e inglês,com no máximo 250 palavras. Para os artigos originais, <strong>de</strong>veráser estruturado (Objetivo, Métodos, Resultados, Conclusão),ressaltando os dados mais significativos do trabalho.Para Relatos <strong>de</strong> Caso, Revisões ou Atualizações, o resumonão <strong>de</strong>verá ser estruturado. Abaixo do resumo, especificar nomínimo cinco e no máximo <strong>de</strong>z <strong>de</strong>scritores (Keywords) que<strong>de</strong>finam o assunto do trabalho. Os <strong>de</strong>scritores <strong>de</strong>verão serbaseados no DeCS - Descritores em Ciências da Saú<strong>de</strong> - disponívelno en<strong>de</strong>reço eletrônico http://<strong>de</strong>cs.bvs.br/Abaixo do Resumo, indicar, para os Ensaios Clínicos, onúmero <strong>de</strong> registro na base <strong>de</strong> Ensaios Clínicos (http://clinicaltrials.gov)*C) TextoDeverá obe<strong>de</strong>cer rigorosamente a estrutura para cada categoria<strong>de</strong> manuscrito.Em todas as categorias <strong>de</strong> manuscrito, a citação dos autoresno texto <strong>de</strong>verá ser numérica e seqüencial, utilizando al-Rev Bras Oftalmol. 2009; 68 (5): 372-4


373garismos arábicos entre parênteses e sobrescritos. As citaçõesno texto <strong>de</strong>verão ser numeradas seqüencialmente em númerosarábicos sobrepostos, <strong>de</strong>vendo evitar a citação nominaldos autores.Introdução: Deve ser breve, conter e explicar os objetivose o motivo do trabalho.Métodos: Deve conter informação suficiente para saberseo que foi feito e como foi feito. A <strong>de</strong>scrição <strong>de</strong>ve ser clara esuficiente para que outro pesquisador possa reproduzir oudar continuida<strong>de</strong> ao estudo. Descrever a metodologia estatísticaempregada com <strong>de</strong>talhes suficientes para permitir quequalquer leitor com razoável conhecimento sobre o tema e oacesso aos dados originais possa verificar os resultados apresentados.Evitar o uso <strong>de</strong> termos imprecisos tais como: aleatório,normal, significativo, importante, aceitável, sem <strong>de</strong>finilos.Os resultados da pesquisa <strong>de</strong>vem ser relatados neste capítuloem seqüência lógica e <strong>de</strong> maneira concisa.Informação sobre o manejo da dor pós-operatório, tantoem humanos como em animais, <strong>de</strong>ve ser relatada no texto(Resolução nº 196/96, do Ministério da Saú<strong>de</strong> e Normas Internacionais<strong>de</strong> Proteção aos Animais).Resultados: Sempre que possível <strong>de</strong>vem ser apresentadosem Tabelas, Gráficos ou Figuras.Discussão: Todos os resultados do trabalho <strong>de</strong>vem serdiscutidos e comparados com a literatura pertinente.Conclusão: Devem ser baseadas nos resultados obtidos.Agra<strong>de</strong>cimentos: Devem ser incluídos colaborações <strong>de</strong>pessoas, instituições ou agra<strong>de</strong>cimento por apoio financeiro,auxílios técnicos, que mereçam reconhecimento, mas nãojustificam a inclusão como autor.Referências: Devem ser atualizadas contendo, preferencialmente,os trabalhos mais relevantes publicados, nosúltimos cinco anos, sobre o tema. Não <strong>de</strong>ve conter trabalhosnão referidos no texto. Quando pertinente, é recomendávelincluir trabalhos publicados na RBO. As referências<strong>de</strong>verão ser numeradas consecutivamente, na or<strong>de</strong>m em quesão mencionadas no texto e i<strong>de</strong>ntificadas com algarismosarábicos. A apresentação <strong>de</strong>verá seguir o formato <strong>de</strong>nominado“Vancouver Style” , conforme mo<strong>de</strong>los abaixo. Os títulosdos periódicos <strong>de</strong>verão ser abreviados <strong>de</strong> acordo com oestilo apresentado pela National Library of Medicine, disponívelna “List of Journal In<strong>de</strong>xed in In<strong>de</strong>x medicus” noen<strong>de</strong>reço eletrônico: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=journalsPara todas as referências, citar todos os autores até seis.Quando em número maior, citar os seis primeiros autoresseguidos da expressão et al.Artigos <strong>de</strong> Periódicos:Dahle N, Werner L, Fry L, Mamalis N. Localized, centraloptic snowflake <strong>de</strong>generation of a polymethyl methacrylateintraocular lens: clinical report with pathological correlation.Arch Ophthalmol. 2006;124(9):1350-3.Arnarsson A, Sverrisson T, Stefansson E, Sigurdsson H,Sasaki H, Sasaki K, et al. Risk factors for five-year inci<strong>de</strong>nt agerelatedmacular <strong>de</strong>generation: the Reykjavik Eye Study. Am JOphthalmol. 2006;142(3):419-28.Livros:Yamane R. Semiologia ocular. 2a ed. Rio <strong>de</strong> Janeiro: CulturaMédica; 2003.Capítulos <strong>de</strong> Livro:Oréfice F, Boratto LM. Biomicroscopia. In: Yamane R.Semiologia ocular. 2ª ed. Rio <strong>de</strong> Janeiro:Cultura Médica; 2003.Dissertações e Teses:Cronemberger S. Contribuição para o estudo <strong>de</strong> algunsaspectos da aniridia [tese]. São Paulo: Universida<strong>de</strong> Fe<strong>de</strong>ral<strong>de</strong> São Paulo; 1990.Publicações eletrônicas:Herzog Neto G, Curi RLN. Características anatômicas dasvias lacrimais excretoras nos bloqueios funcionais ou síndrome<strong>de</strong> Mil<strong>de</strong>r. Rev Bras Oftalmol [periódico na Internet]. 2003[citado 2006 Jul 22];62(1):[cerca <strong>de</strong> 5p.]. Disponível em:www.sboportal.org.brTabelas e Figuras: A apresentação <strong>de</strong>sse material <strong>de</strong>ve serem preto e branco, em folhas separadas, com legendas e respectivasnumerações impressas ao pé <strong>de</strong> cada ilustração. <strong>Nov</strong>erso <strong>de</strong> cada figura e tabela <strong>de</strong>ve estar anotado o nome domanuscrito e dos autores. Todas as tabelas e figuras também<strong>de</strong>vem ser enviadas em arquivo digital, as primeiras preferencialmenteem arquivos Microsoft Word(r)e as <strong>de</strong>mais em arquivosMicrosoft Excel(r), Tiff ou JPG. As gran<strong>de</strong>zas, unida<strong>de</strong>se símbolos utilizados nas tabelas <strong>de</strong>vem obe<strong>de</strong>cer a nomenclaturanacional. Fotografias <strong>de</strong> cirurgia e <strong>de</strong> biópsias on<strong>de</strong>foram utilizadas colorações e técnicas especiais, serão consi<strong>de</strong>radaspara impressão colorida, sendo o custo adicional <strong>de</strong>responsabilida<strong>de</strong> dos autores.Legendas: Imprimir as legendas usando espaço duplo,acompanhando as respectivas figuras (gráficos, fotografias eilustrações) e tabelas. Cada legenda <strong>de</strong>ve ser numerada emalgarismos arábicos, correspon<strong>de</strong>ndo as suas citações no texto.Abreviaturas e Siglas: Devem ser precedidas do nomecompleto quando citadas pela primeira vez no texto ou naslegendas das tabelas e figuras.Se as ilustrações já tiverem sido publicadas, <strong>de</strong>verão viracompanhadas <strong>de</strong> autorização por escrito do autor ou editor,constando a fonte <strong>de</strong> referência on<strong>de</strong> foi publicada.O texto <strong>de</strong>ve ser impresso em computador, em espaçoduplo, papel branco, no formato 210mm x 297mm ou A4,em páginas separadas e numeradas, com margens <strong>de</strong> 3cm ecom letras <strong>de</strong> tamanho que facilite a leitura (recomendamosas <strong>de</strong> nº 14). O original <strong>de</strong>ve ser encaminhado em uma via,acompanhado <strong>de</strong> CD ou disquete 3,5", com versão do manuscrito,com respectivas ilustrações, digitado no programa“Word for Windows 6.0.A Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> reserva o direito <strong>de</strong>não aceitar para avaliação os artigos que não preencham oscritérios acima formulados.* Nota importante: A “Revista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>”em apoio às políticas para registro <strong>de</strong> ensaios clínicos daOrganização Mundial <strong>de</strong> Saú<strong>de</strong> (OMS) e do IntemationalCommittee of Medical Joumal Editors (ICMJE), reconhecendoa importância <strong>de</strong>ssas iniciativas para o registro e divulgaçãointernacional <strong>de</strong> informação sobre estudos clínicos, em acessosomente aceitará para publicação, a partir <strong>de</strong> 2008, osartigos <strong>de</strong> pesquisas clínicas que tenham recebido um número<strong>de</strong> i<strong>de</strong>ntificação em um dos Registros <strong>de</strong> Ensaios Clínicosvalidados pelos critérios estabelecidos pela OMS e ICMJE,disponível no en<strong>de</strong>reço: http://clinicaltrials.gov ou no site doPubmed, no item .O número <strong>de</strong> i<strong>de</strong>ntificação <strong>de</strong>verá ser registrado abaixodo resumo.Os trabalhos <strong>de</strong>verão ser enviados àRevista <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong>Rua São Salvador, 107 - LaranjeirasCEP 22231-170 - Rio <strong>de</strong> Janeiro - RJRev Bras Oftalmol. 2009; 68 (5): 372-4


374Revista<strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong>Declaração dos Autores (É necessária a assinatura <strong>de</strong> todos os autores)Em consi<strong>de</strong>ração ao fato <strong>de</strong> que a <strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> está interessada em editar o manuscritoa ela encaminhado pelo(s) o(s) autor(es) abaixo subscrito(s), transfere(m) a partir da presente data todos osdireitos autorais para a <strong>Socieda<strong>de</strong></strong> <strong>Brasileira</strong> <strong>de</strong> <strong>Oftalmologia</strong> em caso <strong>de</strong> publicação pela Revista <strong>Brasileira</strong> <strong>de</strong><strong>Oftalmologia</strong> do manuscrito............................................................. . Os direitos autorais compreen<strong>de</strong>m qualquer e todasas formas <strong>de</strong> publicação, tais como na mídia eletrônica, por exemplo. O(s) autor (es) <strong>de</strong>clara (m) que o manuscritonão contém, até on<strong>de</strong> é <strong>de</strong> conhecimento do(s) mesmo(s), nenhum material difamatório ou ilegal, que infrinja alegislação brasileira <strong>de</strong> direitos autorais.Certificam que, <strong>de</strong>ntro da área <strong>de</strong> especialida<strong>de</strong>, participaram cientemente <strong>de</strong>ste estudo para assumir aresponsabilida<strong>de</strong> por ele e aceitar suas conclusões.Certificam que, com a presente carta, <strong>de</strong>scartam qualquer possível conflito financeiro ou <strong>de</strong> interesse quepossa ter com o assunto tratado nesse manuscrito.Título do Manuscrito___________________________________________________________________________Nome dos Autores____________________________________________________________________________________________________________________________________________________________________________Minha assinatura abaixo indica minha total concordância com as três <strong>de</strong>clarações acima.Data____________Assinatura do Autor____________________________________________________________Data____________Assinatura do Autor____________________________________________________________Data____________Assinatura do Autor_____________________________________________________________Data____________Assinatura do Autor_____________________________________________________________Data____________Assinatura do Autor____________________________________________________________Data____________Assinatura do Autor_____________________________________________________________Rev Bras Oftalmol. 2009; 68 (5): 372-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!