29.06.2015 Views

Template BA B168xH238 - EcoStar

Template BA B168xH238 - EcoStar

Template BA B168xH238 - EcoStar

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENGLISH<br />

10.2 LED RT<br />

The red LED indicates the operating conditions of the control:<br />

In set-up mode<br />

• Limit switch actuated = LED is off<br />

• Limit switch not actuated = LED is on<br />

Display when teaching in the radio<br />

• Flashes 1x for channel 1 (impulse command)<br />

• Flashes 2x for channel 2 (partial opening command)<br />

• Flashes quickly when saving the radio code<br />

Display when deleting the radio<br />

• Flashes slowly to signal readiness for deletion<br />

• Flashes quickly while deleting all radio codes<br />

Display of the button inputs, radio<br />

• Actuated = LED is on<br />

• Not actuated = LED is off<br />

In normal mode<br />

Flashing code as an error/diagnosis display<br />

10.3 Display of errors/warnings<br />

The red LED RT helps to easily identify causes when<br />

operation does not go according to plan.<br />

NOTE:<br />

If normal operation of the sliding gate operator with the radio<br />

receiver or circuit board button T is otherwise possible, a<br />

short circuit in the external button's connecting lead or in the<br />

button itself can be recognised through the behaviour<br />

described here.<br />

Display flashes 2x<br />

Error/warning<br />

Safety/protective device has responded<br />

Possible cause<br />

• Safety/protective device has been actuated<br />

• Safety/protective device defective<br />

Remedy<br />

Check safety/protective device<br />

Display flashes 3x<br />

Error/warning<br />

Force limit in CLOSE direction<br />

Possible cause<br />

Obstruction in gate area<br />

Remedy<br />

Remove obstruction; check forces, increase if necessary<br />

Display flashes 4x<br />

Error/warning<br />

Hold or static current circuit is open, operator at a standstill<br />

Possible cause<br />

• Normally closed contact at terminal 12/13 is open<br />

• Electric circuit interrupted<br />

Remedy<br />

• Close contact<br />

• Check electric circuit<br />

Display flashes 5x<br />

Error/warning<br />

Force limit in OPEN direction<br />

Possible cause<br />

Obstruction in gate area<br />

Remedy<br />

Remove obstruction; check forces, increase if necessary<br />

Display flashes 6x<br />

Error/warning<br />

System error<br />

Possible cause<br />

Internal error<br />

Remedy<br />

Perform a factory reset (see section 11) and teach in the<br />

control again (see section 4.2) or exchange it if necessary<br />

Display flashes 7x<br />

Error/warning<br />

Peak force<br />

Possible cause<br />

• Motor blocked<br />

• Force cut-out has not responded<br />

Remedy<br />

Check the motor for seizure<br />

10.4 Error acknowledgement<br />

If an error occurs, this can be acknowledged, provided the<br />

error is no longer present.<br />

▶ On pressing the internal or external impulse generator,<br />

the error is deleted and the gate travels in the<br />

corresponding direction.<br />

11 Resetting the Control/Restoring<br />

Factory Settings<br />

To reset the control (taught-in end-of-travel positions,<br />

forces):<br />

1. Set DIL switch 2 to ON.<br />

2. Immediately press circuit board button P briefly.<br />

3. When the red LED flashes rapidly, DIL switch 2 must be<br />

quickly set to OFF.<br />

The control has now been reset to the factory settings.<br />

12<br />

Dismantling and Disposal<br />

Note:<br />

When disassembling, observe the applicable regulations<br />

regarding occupational safety.<br />

Have a specialist dismantle the sliding gate operator in the<br />

reverse order of these instructions and dispose of it properly.<br />

16 TR10L019-A RE / 05.2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!