6. Pump groups DN25 / DN32<br />
6.3 Technical data V-UK and V-MK<br />
Technical data: Pump groups V-UK DN 25 and 32<br />
DN 25 32<br />
top connection G 1“ female thread G 1 1/4“ female thread<br />
bottom connection G 1 1/2“ (flat seal)<br />
Pump see article number<br />
Axis-Centre distance from 175 mm upwards<br />
Components made from steel, brass, EPS insulation<br />
Dimensions per line approx. height 550 x width 250 x depth 175 mm<br />
Sealant materials PTFE, asbestos-free fibre seal, EPDM<br />
Temperature display 0 to 120 °C<br />
Operating temperature up to 110 °C<br />
Operating pressure PN 10<br />
k VS – value 9,7 11<br />
Note: Change of side is possible before supply and return, overflow set can be retrofitted.<br />
Technical data: Pump groups V-MK DN 25 and 32<br />
DN 25 32<br />
top connection G 1“ female thread G 1 1/4“ female thread<br />
bottom connection G 1 1/2“ (flat seal)<br />
Pump see article number<br />
Axis-Centre distance from 200 mm upwards<br />
Components made from steel, brass, EPS insulation<br />
Dimensions per line approx. height 550 x width 250 x depth 240 mm<br />
Sealant materials PTFE, asbestos-free fibre seal, EPDM<br />
Temperature display 0 to 120 °C<br />
Operating temperature up to 110 °C<br />
Operating pressure PN 10<br />
k VS – value 6,2 6,4<br />
Summary of power output / flow rates V-UK / V-MK<br />
Group<br />
Nominal<br />
width<br />
k in m vs 3/ h<br />
UK MK<br />
v = 0.5 m/s<br />
Q in <strong>kW</strong><br />
V in l/h ΔT = ΔT =<br />
10 K 20 K<br />
V in l/h<br />
v = 1.0 m/s<br />
Q in <strong>kW</strong><br />
ΔT = ΔT =<br />
10 K 20 K<br />
V in l/h<br />
v = 1.5 m/s<br />
Q in <strong>kW</strong><br />
ΔT = ΔT =<br />
10 K 20 K<br />
1“ DN25 9.7 6.2 1045 12 24 2091 24 28 3136 36 71<br />
1 1/4“ DN32 11 6.4 1821 21 41 3642 42 84 5463 62 124<br />
v Flow velocity<br />
V Volume flow<br />
Q Power<br />
T Temperature spread - supply and return<br />
ATTENTION: The flow rate is determined by the respective pump that is used!<br />
k VS Flow volume with a 1 bar pressure drop and full throughflow<br />
(without a pump)<br />
UK Direct heating circuit<br />
MK Mixed heating circuit<br />