<strong>FIREX</strong><br />

PROACTIVE FIRE PROTECTION SYSTEMS<br />

<strong>FIREX</strong> <strong>BOARD</strong><br />

Patented<br />

Worldwide<br />

GB9706479.4<br />

The Revolutionary New Fireproof Panel Material for the 21st Century<br />

The World's Highest Fire-Rated Fireproof Board<br />

THE BEST PROTECTION FOR YOUR FIRE SAFETY AND PROPERTY<br />

®


1<br />

C<br />

O N T E N T S<br />

ABOUT NEW CITY RESOURCES INC. .................................................................. 2<br />

GENERAL INFORMATION.................................................................................... 3<br />

1. Proactive Fire Protection ................................................................................................ 3<br />

1.1 What is Proactive Fire Protection? ................................................................................................3<br />

1.2 Fire Test Standard - Test on Material .............................................................................................3<br />

1.3 Fire Test Standard - Test on Construction of Systems ...................................................................4<br />

2. <strong>FIREX</strong> <strong>BOARD</strong> – Introduction .......................................................................................... 5<br />

3. <strong>FIREX</strong> <strong>BOARD</strong> – Applications ......................................................................................... 6<br />

TECHNICAL DATA .............................................................................................. 7<br />

1. <strong>FIREX</strong> <strong>BOARD</strong> and <strong>FIREX</strong> <strong>BOARD</strong>-H ............................................................................... 7<br />

2. <strong>FIREX</strong> <strong>BOARD</strong> in Comparison with Other Panel Materials .............................................9<br />

3. Recommended <strong>FIREX</strong> <strong>BOARD</strong> Accessories ................................................................... 9<br />

4. <strong>Building</strong> <strong>FIREX</strong> Systems ............................................................................................... 10<br />

5. Finishing .......................................................................................................................10<br />

CEILINGS .......................................................................................................... 11<br />

PARTITIONS...................................................................................................... 14<br />

HOARDING ........................................................................................................ 17<br />

SMOKE BARRIERS............................................................................................ 19<br />

ENCLOSURES FOR E&M SERVICES.................................................................. 21<br />

FIRE-RATED DOORS ......................................................................................... 24<br />

SOLID WALL FIRE-RATING UPGRADE .............................................................. 25<br />

Under the intense heat of over 2000°C, <strong>FIREX</strong> <strong>BOARD</strong> proves incombustible and shows:<br />

No Smoke or Fume No Shrinkage or Distortion<br />

No Burn-up or Meltdown No Damage or Stain!


ABOUT NEW CITY RESOURCES INC.<br />

New City Resources Inc. (NCR), a Canadian company established in 1994, is a member of the N C R Group – the<br />

manufacturing arm of the Ling Kee Group operating in Hong Kong, Shanghai, London, New York, Abbotsford,<br />

Bowmanville, Toronto and Vancouver. NCR is the pioneering innovator of new panel materials and is the manufacturer<br />

of the world’s first all-weather, eco-friendly, everlasting and colourfast panel material – Polyboard ® , the revolutionary<br />

new all-purpose fireproof board – <strong>FIREX</strong> <strong>BOARD</strong> ® and the best fireproof solid wall system – <strong>FIREX</strong>WALL .<br />

NCR currently operates two manufacturing facilities – Bowmanville, Canada and Shanghai, China to serve its global<br />

customer base. Unusually, it started with R & D with a view to searching for a new way of producing an environmentallyprotecting<br />

panel material to replace the wood-based boards such as plywood, MDF, OSB. After three years of intensive<br />

research, NCR succeeded in inventing the 400% environmental Polyboard which eliminates polluting waste to save<br />

precious trees and rain forests to contain global warming, while producing no toxic gas emission in production nor<br />

further waste in use. Polyboard is waterproof, weatherproof, decay-proof, leakage-proof, soundproof, corrosionresistant,<br />

termite-repellent and ramming-resistant. It is everlasting, indestructible, odourless and non-toxic, outperforming<br />

all other panel materials in all applications– indoors, outdoors, underground and underwater.<br />

The success of the waterproof Polyboard has led to the invention of the revolutionary new fireproof board –<br />

<strong>FIREX</strong> <strong>BOARD</strong> which is incombustible and 100% asbestos and crystalline silica free. <strong>FIREX</strong> <strong>BOARD</strong> is the world’s highest<br />

fire-rated fireproof board, withstanding intense heat of 1200°C for 5 hours with a single layer of 6 mm for ceilings and<br />

4 hours with a layer of 6 mm on each side of a common steel stud frame for partitions in accordance with BS 476: Part<br />

22: 1987. It outmatches any other fire-resistant panel material in all applications and in price, thus offering the best of<br />

both worlds, and is becoming the market leader in fire prevention for any place where fire safety is essential.<br />

Recently, NCR has developed the <strong>FIREX</strong>WALL Solid Wall System, which is the most efficient and economical way to<br />

build internal walls by using a steel stud frame lined with a single layer of <strong>FIREX</strong>WALL sheet on each side, and filled with<br />

a lightweight concrete core mix – the best alternative to labor-intensive masonry or precast wall systems. <strong>FIREX</strong>WALL is<br />

recognized as the best fireproof solid wall system, replacing brick/block walls, precast concrete wall systems and<br />

other in-situ infill wall systems using fiber-cement boards.<br />

NCR is committed to working closely with customers to achieve further progress in the 21st Century by offering more<br />

unique products which work wonders for them.<br />

CUSTOMER SERVICES<br />

NEW CITY RESOURCES INC.<br />

NCR's Technical and Customer Service is ready to give comprehensive information and expert guidance on our<br />

products and systems. Customers or architects can obtain technical advice and samples from our Regional Offices.<br />

▲ NCR Industrial Centre — 470,000 sq.ft. of usable space located<br />

in Bowmanville, Ontario, Canada<br />

2


G<br />

1<br />

The term "proactive fire protection" is used to describe products<br />

and systems which become part of the construction of a building.<br />

These products and systems are tested by independently<br />

approved testing authorities under standard testing conditions.<br />

They are designed to protect the building structure, to restrict<br />

1.2 FIRE TEST STANDARDS - Test on Materials<br />

The standard most commonly referred to in <strong>Building</strong> Codes by<br />

most Asian countries and Hong Kong is the British Standard<br />

(BS 476).<br />

BS 476: Part 4: 1970<br />

Non-combustibility test for materials.<br />

This test classifies materials as either "non-combustible" or<br />

"combustible". It is the most stringent standard for testing the<br />

fire resistance of materials and gives a measure of the heat<br />

and flames generated by the material under standard heating<br />

conditions.<br />

Non-combustible materials can be used without restriction<br />

anywhere in a building. Their use ensures that hazards due to<br />

smoke and toxic gases are minimized and that the fabric of a<br />

1.3 FIRE TEST STANDARDS - Test on Construction of Systems<br />

Fire Testing Method<br />

The fire resistance of a system will vary according to the heating<br />

conditions it is exposed to. The fire curve adopted by the British<br />

Standards Institute to simulate fires in tests is called the<br />

Cellulosic Time-Temperature Curve (see graph). This curve is<br />

used in standards throughout the world as a model of a ventilated<br />

controlled natural fire, i.e. fires in a normal building.<br />

Under the British Standard, the system under test is<br />

progressively heated in an accurately controlled furnace, the<br />

temperature of which varies with time as closely as possible to<br />

the Cellulosic Time-Temperature Curve. The heat evolved is<br />

not necessarily that which is produced in a true fire situation,<br />

but is an agreed standard for purposes of comparison. According<br />

to the graph, the temperature of the furnace is increased to<br />

822°C after 30 minutes, to 1029°C after 120 minutes, and to a<br />

maximum of 1193°C after 360 minutes. These figures illustrate<br />

3<br />

ENERAL INFORMATION<br />

Proactive Fire Protection<br />

1.1 WHAT IS PROACTIVE FIRE PROTECTION ?<br />

fires within designated compartments and minimize their severity<br />

and to protect the adjacent properties and their occupants.<br />

Additionally, they ensure the safe escape of building occupants<br />

in case of fire.<br />

how stringent the tests are in respect of the elements of structure. British Standard Cellulosic Time-Temperature Curve for<br />

Fire Testing Performance<br />

Fire resistance is not a property of a material but the performance<br />

of a complete element of construction which will generally be<br />

composed of a number of different materials. A fire-resisting<br />

construction can be one of any number of elements in a building,<br />

eg. wall, ceiling, duct, protected shaft or cavity barrier.<br />

The failure criteria of elements of building construction when<br />

building will make no contribution to a fire. All <strong>FIREX</strong> <strong>BOARD</strong><br />

products are non-combustible as per BS 476: Part 4: 1970. The<br />

equivalent of this standard in China is GB 8624 (GB 5464-85).<br />

BS 476: Part 7: 1987<br />

Method for classification of the surface spread of flame of<br />

products.<br />

This test puts materials into Classes 1 to 4 in descending order<br />

of performance according to the rate and extent of flame spread<br />

over their surface under standard heating conditions. As all<br />

<strong>FIREX</strong> <strong>BOARD</strong> products are non-combustible, they can also be<br />

accepted as having the Class I rating in the surface spread of<br />

flame test.<br />

Temperature rise °C<br />

1200<br />

1100<br />

1000<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

0<br />

30<br />

60<br />

90<br />

120<br />

150<br />

180<br />

210<br />

240<br />

270<br />

300<br />

330<br />

360<br />

Time mins<br />

Fire Tests on <strong>Building</strong> Materials in Structures<br />

tested in accordance with the British Standard (BS 476: Parts<br />

20-24) are as follows:<br />

Loadbearing Capacity<br />

The ability of a specimen of a loadbearing element to support<br />

its test load, where appropriate, without exceeding the specified<br />

criteria with respect to either the extent of, or rate of deformation.


Stability<br />

The ability of the specimen tested to withstand deformation or<br />

collapse.<br />

Integrity<br />

The ability of a test specimen of separable elements to withstand<br />

cracking or opening up to the extent of allowing flames to pass<br />

through the unexposed face.<br />

Insulation<br />

The ability of a test specimen of separable elements to restrict<br />

the temperature rise of the unexposed face to below specified<br />

levels (140°C mean rise, 180°C max. rise).<br />

Fire Testing Standard<br />

The fire performance standard most commonly referred to in<br />

<strong>Building</strong> Codes in Asian countries and Hong Kong is the British<br />

Standard (BS 476: Part 20 to 24). The new European Norm<br />

(EN 1363 – 1366) will gradually replace BS 476 and the current<br />

equivalent are given below:<br />

BS 476: Part 20: 1987 (EN 1363-1: 1999)<br />

This part describes the general procedures and equipment<br />

required to determine the fire resistance of elements of<br />

construction and should be read in conjunction with BS 476:<br />

Part 21, 22, 23 and 24 as appropriate, which describe the<br />

detailed procedures for the testing of individual elements of<br />

construction. For the purposes of these parts, elements of<br />

construction have been categorized into 4 main groups:<br />

a. Loadbearing elements that have fire resistance.<br />

b. Non-loadbearing elements that have fire resistance.<br />

c. Elements that make a contribution to the fire resistance of a<br />

structure.<br />

d. Ducts designed to prevent fire spread across fire barriers.<br />

BS 476: Part 21: 1987 (EN 1365: Part 1 to 4: 1999)<br />

Methods for determining the fire resistance of loadbearing<br />

elements of construction.<br />

This standard describes methods for determining the fire<br />

resistance of loadbearing beams, columns, floors, flat roofs, and<br />

walls. Beams and columns are assessed in terms of loadbearing<br />

capacity, while floors, flat roofs and walls are measured in terms<br />

of loadbearing capacity, integrity and insulation.<br />

The fire resistance of a specimen is the time in minutes from<br />

the start of the test until failure occurs under any one of the<br />

criteria of Stability, Integrity and Insulation if all are appropriate<br />

to the particular type of element being tested; or, if no failure<br />

occurs, until the test is terminated. For example, a test result<br />

showing:<br />

Stability: 180 minutes<br />

Integrity: 120 minutes<br />

Insulation: 120 minutes<br />

would mean that a specimen complied with Stability for 180<br />

minutes and complied with the other criteria for 120 minutes.<br />

BS 476: Part 22: 1987 (EN 1364: Part 1 and 2: 1999)<br />

Methods for determination of the fire resistance of nonloadbearing<br />

elements of construction.<br />

This standard describes methods for determining the fire<br />

resistance of non-loadbearing partitions, doorsets, shutter<br />

assemblies, ceiling membranes. Glazed elements of<br />

construction are determined with respect to integrity, and where<br />

appropriate, insulation.<br />

BS 476: Part 23: 1987<br />

Methods for determining the contribution of components<br />

to the fire resistance of a structure.<br />

This standard describes methods for:<br />

▲ <strong>FIREX</strong> Non-Loadbearing Partition System under testing.<br />

a. determining the fire resistance that is provided by a<br />

suspended ceiling to a standard supporting construction of<br />

steel beams and concrete deck; and<br />

b. determining the contribution of intumescent seals to the fire<br />

resistance of timber door assemblies.<br />

BS 476: Part 24: 1987 (EN 1366-1: 1999)<br />

Methods for determining the fire resistance of ventilation<br />

ducts.<br />

The general purpose of this standard is to test and measure the<br />

ability of a duct assembly to resist the spread of fire from one<br />

compartment to another. Results are expressed in terms of<br />

stability, integrity and, where required, insulation.<br />

4


5<br />

2<br />

The World’s First<br />

<strong>FIREX</strong> <strong>BOARD</strong> ®<br />

– Introduction<br />

<strong>FIREX</strong> <strong>BOARD</strong> – the world's highest fire-rated fireproof board<br />

and a revolutionary patented lightweight multi-purpose board<br />

that outperforms all other panels in terms of fire-resistance and<br />

applications. Not only is <strong>FIREX</strong> <strong>BOARD</strong> fireproof, but it is also<br />

ideal as a base for tiling in wet areas.<br />

<strong>FIREX</strong> <strong>BOARD</strong> is made of incombustible materials, using a<br />

special technique and unique formulae to offer fire protection<br />

and durability. It is odourless, non-toxic and completely free of<br />

asbestos and carcinogenic materials such as crystalline silica<br />

or quartz, usually contained in fiber-cement boards and calciumsilicate<br />

boards.<br />

<strong>FIREX</strong> <strong>BOARD</strong> is non-combustible, heat-insulating, rot-proof,<br />

water-resistant, weather-resistant, impact-resistant, soundinsulating,<br />

termite-repellent and non-deforming. It is strong,<br />

durable and nail-holding and no pre-drilling is necessary. It is<br />

versatile and easy to use like wood – it can be cut, sawn, drilled,<br />

nailed, screwed, stapled, wallpapered, painted and fabricated<br />

with veneer, laminate or vinyl covering. Thin sheets can be bent<br />

to suit architectural designs. It is so dimensionally-stable that<br />

expansion and contraction is negligible. It will not delaminate<br />

or deteriorate after prolonged exposure to moisture.<br />

<strong>FIREX</strong> <strong>BOARD</strong> is indispensable in all areas where fire safety is<br />

essential. Its unique properties make it ideal for partitions,<br />

ceilings, drywalls, hoarding, fire barriers, fire doors, A/C or cable<br />

ducts, E&M services enclosures, raised floor cores, etc.<br />

The <strong>FIREX</strong> Suspended Ceiling System is the world's highest<br />

fire-rated system using a single layer of 6 mm <strong>FIREX</strong> <strong>BOARD</strong>,<br />

which achieved a fire rating of 5 hours integrity at 1200°C in<br />

a c cord anc e with the B S 476:<br />

Part 22: 1987.<br />

The <strong>FIREX</strong> Partition System is<br />

the only system achieving a firerating<br />

of 4 hours integrity and<br />

2 hours or 3 hours insulation<br />

in accordance with BS 476: Part<br />

22: 1987 using only 1 layer of<br />

6 mm or 12 mm board affixed to<br />

e a ch sid e of a common ste el<br />

s t u d fr a m e w it h a n o v e r a ll<br />

thickness of about 3 or 4 inches.<br />

The <strong>FIREX</strong> Steel Stud Hoarding System is the thinnest in<br />

the market to achieve a fire-rating of 4 hours integrity in<br />

accordance with BS 476: Part 22: 1987. Moreover, it has<br />

twice the impact resistance of hoarding built with calcium<br />

silicate boards.<br />

<strong>FIREX</strong> <strong>BOARD</strong> can also be used to construct cost-effective<br />

E&M services enclosures and fire barriers for a variety of<br />

applications, including rolling shutter doorsets, fire-rated<br />

steel doors and wood doors.<br />

<strong>FIREX</strong> <strong>BOARD</strong>-H is especially designed for applications that<br />

require superior fire-rating. It can be used for a variety of<br />

applications, including suspended ceilings, ducts, E&M<br />

services enclosures and raised floors. It meets the Federal<br />

Railroad Administration (FRA) approval requirements and<br />

can be used to provide fire protection for passenger trains<br />

and people movers.<br />

Incombustible <strong>FIREX</strong> <strong>BOARD</strong> 5 5 hour-rated<br />

★ 5 HOURS FIRE-RATING<br />

It sustains intense fire test for 5 hours with integrity.<br />

★ NON-COMBUSTIBLE<br />

It is classified as Incombustible Material, Class A.<br />

★ WATER-RESISTANT<br />

It resists moisture in wet areas.<br />

★ WEATHER-RESISTANT<br />

It can withstand both high and low temperatures and<br />

difficult weather conditions.<br />

★ SOUND-INSULATING<br />

It provides excellent sound insulation.<br />

★ HEAT– INSULATING<br />

It achieves excellent heat insulation for personal safety.<br />

★ DECAY-RESISTANT<br />

It does not rot in dry or wet environment.<br />

★ IMPACT–RESISTANT<br />

It withstands heavy impact.<br />

★ TERMITE–REPELLENT<br />

It prevents termite attacks.<br />

★LIGHTWEIGHT AND DURABLE<br />

It is lightweight but tough, sturdy and durable.<br />

★NON-DEFORMING<br />

It does not deform. Expansion/contraction is minimal.<br />

★STRONG AND NAIL-HOLDING<br />

It is of high strength, and holds nails and screws firmly.<br />

No pre-drilling is necessary.<br />

★FABRICATING AND LAMINATING<br />

It can be easily fabricated with honeycomb, veneers,<br />

laminates and vinyl coverings.<br />

★TILING AND WALLING<br />

It can be used as ceramic tile backers. Ideal for drywalls<br />

and partitions in dry and wet environments.<br />

★ODOURLESS AND NON-TOXIC<br />

It is odourless. It contains no asbestos, crystalline silica,<br />

or toxic glues, such as urea/phenol formaldehyde.<br />

★EASY TO USE<br />

It can be sawn, cut, drilled, stapled, taped, glued. Thin<br />

sheets can be bent to fit any architectural design.<br />

The Best Protection for Your Safety and Property<br />

21st Century Product


3<br />

<strong>FIREX</strong> <strong>BOARD</strong> – Applications<br />

Construction • Renovation<br />

<strong>FIREX</strong> <strong>BOARD</strong> is a basic necessity for any place where fire protection is essential — offices, banks,<br />

shopping malls, department stores, supermarkets, cinemas, restaurants, hotels, karaoke, night clubs,<br />

jewellery shops, off-course betting centres, schools, hospitals, dormitories, gymnasiums, recreation and<br />

sports centres, car parks, high-rise residential buildings ......<br />

Non-combustible, strong and durable, <strong>FIREX</strong> <strong>BOARD</strong> is particularly suitable for partitions, ceilings, interior<br />

walls, drywalls, fire walls, hoarding, fire doors, soffits; air-conditioning duct liners, E&M services enclosures,<br />

electric conduit liners, plenum ceilings, core for raised floors, lining panels for elevators; wallcoverings for<br />

lift shaft, stairwell, garages; roof-decks, sound-insulating walls, thermal barriers. <strong>FIREX</strong> <strong>BOARD</strong> is also<br />

good as ceramic tile underlayment in wet environment.<br />

Fire Protective walls for plane cabins and cargo holds. Baggage carrier liners.<br />

Wallcoverings, ceilings, partitions, fire doors, fire separation barriers for<br />

airports, air cargo terminals, air caterers, hangars, fuel storage, passengers<br />

waiting rooms, corridors, boarding gates, etc.<br />

Fire-rated Doors<br />

Air Transport<br />

<strong>FIREX</strong> <strong>BOARD</strong> is used extensively by internationally-renowned door manufacturers as the core for<br />

1-hour, 2-hour and 4-hour fire-rated steel doors and wooden doors.<br />

Shipping<br />

Land Transport<br />

Fire protecting walls, flooring and body for all types of<br />

vehicles — cars, buses, trams, trucks, trailers, tourist<br />

coaches, mobile homes, school buses, ambulances,<br />

trains, cargo trains, MTR/light railcars, particularly for oil<br />

trucks, flammable goods trucks.<br />

Also essential for fire safety in MTR/railway stations,<br />

terminals, multi-storey car parks, gas stations, garages,<br />

cargo handling areas ....<br />

Fireproof, sound-insulating and lightweight, <strong>FIREX</strong> <strong>BOARD</strong> is particularly ideal for<br />

panels, partitions of cabins for all kinds of vessels, especially cruise ships, yachts,<br />

hydrofoils, ferries, oil tankers, LPG carriers. Essential for all types of naval ships.<br />

Industry<br />

Industrial wallcoverings, partitions, ceilings, electric conduit liners, A/C duct covering,<br />

oil, flammable goods storage; fire doors, fire exits, fire separation barriers for factories,<br />

warehouses, electric sub-stations, .... Fire protective wall, lift shaft and stairwell liners<br />

for multi-storey industrial buildings.<br />

6


T<br />

<strong>FIREX</strong> <strong>BOARD</strong><br />

7<br />

E C H N I C A L D A T A<br />

1 <strong>FIREX</strong> <strong>BOARD</strong><br />

– Technical Data<br />

The following section describes the properties and specifications<br />

of <strong>FIREX</strong> <strong>BOARD</strong> and <strong>FIREX</strong> <strong>BOARD</strong>-H and the recommended<br />

accessories for use with the product. <strong>FIREX</strong> <strong>BOARD</strong> and<br />

<strong>FIREX</strong> <strong>BOARD</strong>-H are non-combustible and can be used in the<br />

Thickness : 2 mm 3 mm 4 mm 6 mm 9 mm 12 mm 16 mm 19 mm 25 mm - 60 mm<br />

Size : 4' X 8' (1220 mm X 2440 mm) 3' X 6' (915 mm x 1830 mm) or any custom-cut size<br />

Texture : Smooth surface White<br />

Applications<br />

General Technical Data<br />

Testing Item Testing Standard Test Result<br />

Density ASTM C1185 690 kg/m3 43 lbs/ft3 Impact Strength ASTM D3029 4.04 m.kg 29.17 ft/lbs<br />

Flexural Modulus of Elasticity<br />

Long. 7820 MPa 1.134 x10 6 ASTM C120<br />

Trav. 6347 MPa<br />

psi<br />

0.92 x10 6 psi<br />

Flexural Modulus of Rupture<br />

ASTM C120<br />

Long. 31.42 MPa<br />

Trav. 30.84 MPa<br />

4577 psi<br />

4473 psi<br />

Hardness ASTM D1037 2 738 N 615 lbs<br />

Moisture Content ASTM C1185 12.4% 12.4%<br />

Water Absorption ASTM C1185 33% 33%<br />

Water Vapour Transmission ASTM E96 11.8 g/hour.m2 16.9 grains/hr.ft2 Thermal Conductivity ASTM C518 0.3096 W/m•K 2.147 Btu•in/ft2 •h•F Thermal Resistance (R Value) ASTM C518 0.0577 m2 •K/W 0.328 F•ft2 •h/Btu<br />

Fastener Pull Resistance ASTM D473 937.5 N 210.5 lbs<br />

Dimensional Stability — Creep Modulus ASTM D2990 433 MPa/cm 24725 psi/in<br />

Dimensional Stability — Load Deflection ASTM D2990 2.59 •10 -3 of Span 2.59 •10 -3 of Span<br />

Non-Combustibility<br />

BS 476: Part 4<br />

GB 8624 (GB5464)<br />

Non-Combustible Material<br />

Class A<br />

Milling : Square Edge Tapered Edge<br />

• Structural steel<br />

• Ceilings<br />

• Partitions<br />

• Hoarding<br />

• E&M services enclosures<br />

• Concrete upgrading<br />

• Fire resistant glazing<br />

• Smoke barriers, access panels<br />

same way as timber materials. It can be worked with<br />

conventional machines and woodworking tools and can be fixed<br />

to each other and other building materials by common fastening<br />

elements.<br />

BUTT AND FLUSH JOINTING<br />

Steel Stud<br />

Square Edge for butt jointing<br />

Steel Stud<br />

Tapered Edge for flush jointing


<strong>FIREX</strong> <strong>BOARD</strong>-H<br />

Applications<br />

General Technical Data<br />

Testing Item Testing Standard Test Result<br />

Density ASTM C1185 1320kg/m3 82 lbs/ft3 Impact Strength ASTM D5628<br />

Face Up 4.72 J Face Up 3.65 ft.lb<br />

Face Down 4.19 J Face Down 3.44 ft.lb<br />

Flexural Modulus of Elasticity ASTM C1185 1560 MPa 226000 psi<br />

Flexural Modulus of Rupture ASTM C1185 19 MPa 2756 psi<br />

Hardness ASTM D1037<br />

Face Up 5970 N Face Up 1340 lb<br />

Face Down 6730 N Face Down 1510 lb<br />

Moisture Content ASTM C1185 7.2% 7.2%<br />

Water Absorption ASTM C1185 17.1% 17.1%<br />

Thermal Conductivity ASTM C518 0.089 W/m•K 0.617 Btu•in/ft2 •h•F Thermal Resistance (R Value) ASTM C518 0.143 m2 •K/W 0.81 F•ft2 •h/Btu<br />

Fastener Pull Resistance ASTM D473 1960 N 440 lbs<br />

Dimensional Stability — Creep Modulus ASTM D2990 0.88 MPa/cm 3605 psi/in<br />

Dimensional Stability — Load Deflection<br />

FRA Title 49 Subtitle B Chapter II Part 238:<br />

ASTM D2990 0.66 mm 0.0256 in<br />

• Flammability ASTM E162 Pass<br />

• Smoke Emission ASTM E662 Pass<br />

• Toxic Gas Generation Boeing BS 7239 Pass<br />

Non-Combustibility<br />

BS 476: Part 4<br />

GB 8624 (GB5464)<br />

Non-Combustible Material<br />

Class A<br />

Thickness : 9 mm 12 mm 16 mm 19mm 25mm<br />

Size : 4' X 8' (1220 mm X 2440 mm) or any custom-cut size<br />

Texture : Smooth surface Biege<br />

Milling : Square Edge Tapered Edge<br />

• Structural steel • E&M services enclosures<br />

• Ceilings • Concrete upgrading<br />

• Raised floors • Fire resistant glazing<br />

• Partitions • Smoke barriers, access panels<br />

• Hoarding • Fire protection for passenger trains<br />

• Duct work and people movers<br />

▼<br />

Comprehensive independent testing of all<br />

<strong>FIREX</strong> <strong>BOARD</strong> and systems has been carried out<br />

by independent and nationally approved<br />

laboratories around the world in order to meet the<br />

relevant sections of ASTM, BS 476 and many other<br />

international standards.<br />

8


Ceramic Fiber<br />

■ Description: <strong>FIREX</strong>WOOL ® Ceramic Fiber Blanket/Mat is<br />

lightweight, have low thermal conductivities, low heat storage<br />

and excellent resistance to thermal shock. <strong>FIREX</strong>WOOL<br />

blankets/mats are available in a wide range of temperature<br />

and density compositions, are flexible and are ready to cut<br />

and fabricated. They can be used for temperatures from<br />

50°C to 1160°C.<br />

9<br />

2<br />

3<br />

<strong>FIREX</strong> <strong>BOARD</strong><br />

Feature<br />

NON-COMBUSTIBLE<br />

MOISTURE-RESISTANT<br />

WEATHER-RESISTANT<br />

IMPACT-RESISTANT<br />

SOUND-INSULATING<br />

HEAT-INSULTING<br />

DECAY-RESISTANT<br />

TERMITE-REPELLENT<br />

FUNGI-REPELLENT<br />

NON-DEFORMING<br />

SAFE TO USE<br />

EASY TO USE:<br />

Sawing<br />

Drilling<br />

Stapling<br />

Glueing<br />

Nail-holding ability<br />

Screw-holding ability<br />

Fabricating<br />

Foiling<br />

Veneering<br />

Varnishing<br />

Painting<br />

Wallpapering<br />

Tiling<br />

Bendable (Below 6mm)<br />

FIRE RESISTANCE LEVEL<br />

(6mm Integrity as per BS 476: PART 22)<br />

DENSITY (kg/m 3 )<br />

LIFE SPAN (Indoors)<br />

*CS = Respirable Crystalline Silica (Quartz)<br />

UF = Urea Formaldehyde<br />

PF = Phenol Formaldehyde<br />

MDI = Isocyanate Polyurethene<br />

<strong>FIREX</strong> <strong>BOARD</strong><br />

in Comparison with Other Panel Materials<br />

Solid Wood Plywood M D F Particle Gypsum Sansilica Fibre-Cement Calcium Silicate<br />

board board board board board (myca) board board board<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

No<br />

Non-rated<br />

580-880<br />

20-30 yrs<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

*UF/PF<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

Yes<br />

No<br />

?<br />

Non-rated<br />

600-800<br />

15-20 yrs<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

*UF/PF<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Insecure<br />

Insecure<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

?<br />

Non-rated<br />

550-950<br />

10-15 yrs<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

*UF/PF<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

No<br />

Fragile<br />

Yes<br />

Yes<br />

No<br />

No<br />

No<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

*CS<br />

Carcinogenic<br />

Yes Yes Yes Yes Yes<br />

Yes Yes Yes Yes Yes<br />

Yes No No No No<br />

Yes Yes No No No<br />

Insecure No No No No<br />

Insecure Insecure Insecure Insecure Insecure<br />

Yes Yes No No No<br />

Yes Yes No No No<br />

Yes Yes No No No<br />

No No No No No<br />

Yes Yes Yes Yes Yes<br />

Yes Yes Yes Yes Yes<br />

No No Yes Yes Yes<br />

No No No No No<br />

(Plasterboard same)<br />

Non-rated 15 min ≤<br />

(700°C)<br />

60 min<br />

(925°C)<br />

30 min ≤<br />

(822°C)<br />

60 min<br />

(925°C)<br />

590-850 700-950 1000-1100 1200-1450 900-950<br />

10 yrs ? ? ?<br />

?<br />

aÉéÉåÇáåÖ=çå=ÜìãáÇáíó=~åÇ=ã~áåíÉå~åÅÉ<br />

Recommended Accessories<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

No<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

*CS<br />

Carcinogenic<br />

Yes<br />

Yes<br />

No<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

*CS<br />

Carcinogenic<br />

<strong>FIREX</strong><br />

<strong>BOARD</strong><br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Non-toxic<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

300 min<br />

(1200°C)<br />

450–750<br />

Up to 50 yrs


4<br />

Cutting<br />

Thin gauge (≤ 9 mm) <strong>FIREX</strong> <strong>BOARD</strong> can be cut with box cutters<br />

or hand-held saws fitted with carbide tipped cutting blades. If<br />

hand-held saws are to be used, it is recommended to cut<br />

<strong>FIREX</strong> <strong>BOARD</strong> sheets in well ventilated spaces. Workers should<br />

wear protective face masks.<br />

Fastening<br />

The most economical method of fastening<br />

<strong>FIREX</strong> <strong>BOARD</strong> is to use pneumatic nailing and<br />

nailing and stapling equipment. For producing<br />

good screw-connections, variable speed<br />

electric screw drivers with friction clutches are<br />

most suitable.<br />

5<br />

<strong>Building</strong><br />

<strong>FIREX</strong><br />

Systems<br />

Finishing<br />

<strong>FIREX</strong> <strong>BOARD</strong> has a surface good for most forms of decoration.<br />

Tiles or wallcoverings can be applied directly onto <strong>FIREX</strong> <strong>BOARD</strong><br />

without the use of any sealers or paint.<br />

Tiling<br />

For surface preparation, all joints should first be filled with dampproof<br />

filler materials. It is recommended to prime the board to<br />

improve adhesion by reducing the absorbency of the surface.<br />

Joints between adjacent tiles should not coincide with those of<br />

<strong>FIREX</strong> <strong>BOARD</strong>, except in the case of expansion joints.<br />

Painting<br />

Water and emulsion-based paints are compatible with<br />

<strong>FIREX</strong> <strong>BOARD</strong>.<br />

Painting on a <strong>FIREX</strong> <strong>BOARD</strong> surface.<br />

▲ Hand held saws fitted with carbide tipped<br />

cutting discs should be used to cut thick<br />

<strong>FIREX</strong> <strong>BOARD</strong> sheets (> 9 mm thick).<br />

<strong>FIREX</strong> <strong>BOARD</strong> can be fastened with<br />

self-tapping screws and drivers<br />

with friction clutches.<br />

Wallcoverings<br />

<strong>FIREX</strong> <strong>BOARD</strong> requires no special treatment to receive all forms<br />

of traditional and modern wallcoverings. Proprietary adhesives<br />

compatible with the wallcovering should be applied in<br />

accordance with the manufacturers' recommendations.<br />

Plastering<br />

A gap of maximum 2-3 mm should be allowed between board<br />

joints. After the first base application of plastering compound,<br />

all joints including board to board or board to other building<br />

components should be concealed with a glass fiber tape. Finish<br />

this with a final application of plaster to give a seamless<br />

appearance.<br />

Tiling on a <strong>FIREX</strong> <strong>BOARD</strong> surface. Plastering a <strong>FIREX</strong> <strong>BOARD</strong> joint.<br />

Note: When applying any form of paint, filler, adhesive and plastering compound on <strong>FIREX</strong> <strong>BOARD</strong>, the individual manufacturer's instructions should be adhered to<br />

<strong>FIREX</strong> <strong>BOARD</strong> includes both <strong>FIREX</strong> <strong>BOARD</strong> and <strong>FIREX</strong> <strong>BOARD</strong>-H.<br />

▲<br />

10


The <strong>FIREX</strong> Suspended Ceiling Systems are used to provide fire resistance and insulation for general<br />

building services and plenum space and protected lobbies and corridors. They are tested in accordance<br />

with BS 476: Part 22: 1987. The <strong>FIREX</strong> Suspended Ceiling System constructed using only one layer of<br />

6 mm <strong>FIREX</strong> <strong>BOARD</strong> can achieve 5 hours integrity in accordance with BS 476: Part 22: 1987 –<br />

The World's Highest Fire Rating. The advantages of <strong>FIREX</strong> Suspended Ceiling Systems are:<br />

• 5 hours fire rating<br />

• Space saving<br />

• Lightweight<br />

• Water-resistant<br />

• Impact-resistant<br />

<strong>FIREX</strong> Suspended Ceilings<br />

Provide fire protection to general building services and plenum space.<br />

Meets INTEGRITY CRITERION of BS 476: Part 22: 1987.<br />

3<br />

C EILINGS<br />

6<br />

1<br />

1<br />

4<br />

4<br />

7<br />

• Fungi-resistant<br />

• Termite-repellent<br />

• Safe to use<br />

• Easy to install<br />

• Cost-effective<br />

5<br />

2<br />

3<br />

2<br />

Technical Data:<br />

5 hours fire rating, integrity in accordance with BS 476:<br />

Part 22.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Ceiling U channel 76 x 34 x 0.6 mm<br />

(610 x 1220 mm spacing)<br />

3) Steel angle 50 x 50 x 0.6 mm<br />

4) M4 self-tapping screws with 15 mm dia. x 1.1 mm thick<br />

washers at approx. 200 mm centres.<br />

5) 1.8 mm dia. iron string at approx. 1200 mm centres.<br />

6) 6 mm dia. concrete nail at approx. 500 mm centres.<br />

7) Recessed light fitting.<br />

8) <strong>FIREX</strong> <strong>BOARD</strong> access panel with edge reinforced by<br />

0.6 mm thick steel channels.<br />

Recessed Light Fitting Detail Access Panel<br />

Notes:<br />

Self-tapping screws with a head diameter of 11 mm could be used in lieu of washers. The fire rating for this construction<br />

will be at least 4 hours integrity in accordance with BS 476: Part 22: 1987.<br />

Painting or decorative surface treatment can be applied on <strong>FIREX</strong> Suspended Ceilings.<br />

<strong>FIREX</strong> <strong>BOARD</strong> access panel has a fire-rating of 4 hours integrity in accordance with BS 476: Part 22: 1987.<br />

11<br />

2<br />

8


C EILINGS<br />

<strong>FIREX</strong><br />

Insulated Suspended Ceilings<br />

Provide fire protection to general building services and for the lobbies and protected corridors.<br />

Meets INSULATION and INTEGRITY CRITERIA of BS 476: Part 22: 1987.<br />

5<br />

4<br />

6<br />

<strong>FIREX</strong><br />

1<br />

7<br />

3<br />

2<br />

Technical Data:<br />

Insulated Suspended Ceilings<br />

1 hour fire rating, integrity and insulation in accordance<br />

with BS 476: Part 22 with fire from above or below.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Ceramic fiber raw density ≥ 128 kg/m 3 75 mm thick<br />

3) Ceiling U channel 76 x 34 x 0.6 mm<br />

(610 x 1220 mm spacing)<br />

4) Steel angle 50 x 50 x 0.6 mm<br />

5) 6 mm dia. concrete nail at approx. 500 mm centres.<br />

6) M4 self-tapping screws at approx. 200 mm centres.<br />

7) 2.2 mm dia. iron string at approx. 600 mm centres.<br />

Provide fire protection to general building services and for the lobbies and protected corridors.<br />

Meets INSULATION and INTEGRITY CRITERIA of BS 476: Part 22: 1987.<br />

4<br />

5<br />

6<br />

1<br />

7<br />

8<br />

3<br />

2<br />

Technical Data:<br />

2 hours fire rating, integrity and insulation in<br />

accordance with BS 476: Part 22 with fire from above or<br />

below.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong>-H 1 x 9 mm thick<br />

2) Ceramic fiber raw density ≥ 128 kg/m 3 100 mm thick<br />

3) Ceiling U channel 60 x 27 x 0.6 mm<br />

(600 x 600 mm)<br />

<strong>FIREX</strong> <strong>BOARD</strong>-H fillet 80 mm wide 9 mm thick<br />

4) Steel angle 30 x 25 x 0.8 mm<br />

5) M6 anchor bolt at approx. 500 mm centres.<br />

6) M4 self-tapping screws at approx. 150 mm centres.<br />

7) 3.2 mm dia. iron string at approx. 600 mm centres.<br />

8) Expansion jointer.<br />

Note:<br />

<strong>FIREX</strong> Insulated Suspended Ceilings provide thorough protection to life and property.<br />

12


C<br />

<strong>FIREX</strong><br />

13<br />

E I L I N G S<br />

Suspended Ceilings<br />

Provide fire protection to steel beams and concrete floor.<br />

Meets BS 476: Part 23: 1987.<br />

3<br />

6<br />

1<br />

4<br />

5<br />

2<br />

▲<br />

Technical Data:<br />

1 hour fire rating, loadbearing capacity (for steel beams<br />

above) in accordance with BS 476: Part 23.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Ceiling U channel 76 x 34 x 0.6 mm<br />

(610 x 1220 mm spacing)<br />

3) Steel angle 50 x 50 x 0.6 mm<br />

4) M4 self-tapping screws with 15 mm dia. x 1.1 mm thick<br />

washers at approx. 200 mm centres.<br />

5) 1.8 mm diameter iron string at approx. 1220 mm centres.<br />

6) 6 mm dia. concrete nail at approx. 500 mm centres.<br />

Note: The ceiling should be suspended at least 1 m from<br />

the steel beams.<br />

▲ A <strong>FIREX</strong> Suspended Ceiling System is getting ready to be tested.


P ARTITIONS<br />

The <strong>FIREX</strong> Partition Systems are tested in accordance with BS 476: Part 22: 1987. The <strong>FIREX</strong> partition<br />

system constructed with one layer of 6 mm <strong>FIREX</strong> <strong>BOARD</strong> affixed to each side of a steel stud frame is the<br />

thinnest available partition system in the market to achieve 4 hours integrity and 2 hours insulation in<br />

accordance with the BS 476: Part 22: 1987. The advantages of <strong>FIREX</strong> Partition Systems are:<br />

• 4 hours fire rating<br />

• Space saving<br />

• Lightweight<br />

• Water-resistant<br />

<strong>FIREX</strong><br />

• High impact resistant<br />

• Sound-Insulating<br />

• Fungi-resistant<br />

• Termite-repellent<br />

• Safe to use<br />

• Easy to install<br />

• Cost-effective<br />

Steel Stud Internal Non-Loadbearing Partitions<br />

Meets INSULATION and INTEGRITY CRITERIA of BS 476: Part 22: 1987.<br />

3<br />

3<br />

4<br />

9<br />

Wall<br />

9<br />

Ceiling<br />

Floor<br />

8<br />

1<br />

2<br />

8<br />

5<br />

2<br />

7<br />

4<br />

1<br />

6<br />

Technical Data:<br />

1 hour fire rating integrity and insulation in accordance with<br />

BS 476: Part 22.<br />

Nominal thickness of partition: 62 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) Ceramic fiber raw density ≥ 128 kg/m 3 50 mm thick<br />

3) Ceramic fiber seel 50 mm wide<br />

<strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6mm thick<br />

4) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

5) Wall steel U channel 50 x 50 x 0.6 mm<br />

6) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

7) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

8) M6 anchor bolt at approx. 500 mm centres.<br />

9) M4 self-tapping screws at approx. 200 mm centres.<br />

Note: The <strong>FIREX</strong> partition system described above is approved up<br />

to 7 m in height with slight construction amendments. Please<br />

consult New City Resources' technical department for details.<br />

A <strong>FIREX</strong> Partition<br />

System is being<br />

installed.<br />

▲<br />

14


15<br />

P ARTITIONS<br />

<strong>FIREX</strong><br />

Steel Stud Internal Non-Loadbearing Partitions<br />

Meets INSULATION and INTEGRITY CRITERIA of BS 476: Part 22: 1987.<br />

6<br />

4<br />

5<br />

3<br />

bk<br />

9<br />

Wall<br />

bk<br />

Ceiling<br />

Floor<br />

4<br />

3<br />

5<br />

9<br />

2<br />

1<br />

5<br />

2<br />

8<br />

1<br />

2<br />

7<br />

Technical Data:<br />

4 hours integrity and 2 hours insulation fire rating in accordance<br />

with BS 476: Part 22.<br />

Nominal thickness of partition: 74 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 75 mm wide 6 mm thick<br />

3) Ceramic fiber raw density ≥ 128 kg/m 3 63 mm thick<br />

4) Ceramic fiber seal 50 mm wide<br />

<strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

5) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

6) Wall steel U channel 50 x 50 x 0.6 mm<br />

7) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

8) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

9) M6 anchor bolt at approx. 500 mm centres.<br />

10) M4 self-tapping screws at approx. 200 mm centres.<br />

Note: The <strong>FIREX</strong> partition system described above is approved up to<br />

7 m in height with slight construction amendments. Please<br />

consult New City Resources' technical department for details.<br />

4 hours integrity and 176 minutes insulation fire rating in<br />

accordance with BS 476: Part 22.<br />

Nominal thickness of partition: 125 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 12 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 80 mm wide 12 mm thick<br />

3) Ceramic fiber raw density ≥ 143 kg/m 3 75 mm thick<br />

4) Ceramic fiber seal<br />

5) Top and bottom steel U channels 75 x 32 x 0.8 mm<br />

6) Wall steel U channel 75 x 32 x 0.8 mm<br />

7) Horizontal steel U channel (1220 mm c/c) 38 x 12 x 0.9 mm<br />

8) Vertical steel U channel (610 mm c/c) 75 x 45 x 1.2 mm<br />

9) M6 anchor bolt at approx. 500 mm centres.<br />

10) M4 self-tapping screws at approx. 300 mm centres.


P ARTITIONS<br />

<strong>FIREX</strong><br />

Steel Stud Internal Non-Loadbearing Partitions<br />

Meets INSULATION and INTEGRITY CRITERIA of BS 476: Part 22: 1987.<br />

4<br />

5<br />

3<br />

bk<br />

9<br />

6<br />

Wall<br />

bk<br />

Ceiling<br />

Floor<br />

9<br />

2<br />

1<br />

5<br />

2<br />

4<br />

3<br />

5<br />

8<br />

1<br />

2<br />

Technical Data:<br />

4 hours integrity and insulation fire rating in accordance with<br />

BS 476: Part 22. (pending)<br />

7<br />

Nominal thickness of partition: 111 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 9 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 100 mm wide 9 mm thick<br />

3) Mineral wool raw density ≥ 100 kg/m 3 75 mm thick<br />

4) Mineral wool seal 75 mm wide<br />

5) Top and bottom steel U channels 75 x 40 x 0.6 mm<br />

6) Wall steel U channel 75 x 40 x 0.6 mm<br />

7) Horizontal steel U channel 75 x 40 x 0.6 mm<br />

8) Vertical steel U channel (610 mm c/c) 75 x 40 x 0.6 mm<br />

9) M6 anchor bolt at approx. 600 mm centres.<br />

10) M4 self-tapping screws at approx. ≤ 250 mm centres.<br />

▲ A 4-hour FRP <strong>FIREX</strong> Partition System at the Tsing Yi Mass Transit<br />

Railway (MTR) station in Hong Kong.<br />

16


17<br />

H OARDING<br />

The <strong>FIREX</strong> Hoarding System is tested in accordance with BS 476: Part 22: 1987. The <strong>FIREX</strong> Hoarding<br />

System is the thinnest available in the market to achieve 4 hours integrity in accordance with the BS 476:<br />

Part 22: 1987. The advantages of the <strong>FIREX</strong> Hoarding System are:<br />

• 4 hours fire rating<br />

• Space saving<br />

• Lightweight<br />

• Water-resistant<br />

<strong>FIREX</strong><br />

Steel Stud Hoarding<br />

Meets INTEGRITY CRITERION of BS 476: Part 22: 1987<br />

4<br />

2<br />

8<br />

9<br />

1<br />

Ceiling<br />

3<br />

5<br />

7<br />

4<br />

7<br />

3<br />

1<br />

• Weather-resistant<br />

• High impact resistant<br />

• Fungi-resistant<br />

• Termite-repellent<br />

2<br />

6<br />

Technical Data:<br />

• Safe to use<br />

• Easy to install<br />

• Cost-effective<br />

1 hour fire rating, integrity in accordance with BS 476: Part 22;<br />

fire side only.<br />

Nominal thickness of hoarding: 62 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Gypsum board 1 x 12 mm thick<br />

3) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

4) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

5) Wall steel U channel 50 x 50 x 0.6 mm<br />

6) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

7) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

8) M6 anchor bolt at approx. 500 mm centres.<br />

9) M4 self-tapping screws at approx. 200 mm centres.<br />

Note: The <strong>FIREX</strong> hoarding system described above is approved up<br />

to 7 m in height with slight construction amendments. Please<br />

consult New City Resources' technical department for details.<br />

▲ The Hong Kong MTR uses <strong>FIREX</strong> <strong>BOARD</strong> as fireproof hoarding in their<br />

stations. Note that <strong>FIREX</strong> <strong>BOARD</strong> allows for heavyweight anchorage.<br />

Advertising light boxes can be hung on <strong>FIREX</strong> <strong>BOARD</strong> panels with no<br />

problems.


H OARDING<br />

3<br />

4<br />

9<br />

8<br />

3<br />

Wall<br />

9<br />

Ceiling<br />

Floor<br />

8<br />

2<br />

1<br />

4<br />

2<br />

5<br />

2<br />

7<br />

1<br />

4<br />

Technical Data:<br />

4 hours fire rating, integrity in accordance with BS 476: Part 22.<br />

Nominal thickness of hoarding: 74 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 75 mm wide 6 mm thick<br />

3) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

4) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

5) Wall steel U channel 50 x 50 x 0.6 mm<br />

6) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

7) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

8) M6 anchor bolt at approx. 500 mm centres.<br />

9) M4 self-tapping screws at approx. 200 mm centres.<br />

2 hours fire rating, integrity in accordance with BS 476: Part 22.<br />

Fire risk from board side only.<br />

The construction details of this hoarding system is similar to that<br />

shown above with the exception that the exposed side is lined with<br />

one layer of 6 mm thick <strong>FIREX</strong> <strong>BOARD</strong> and fillets.<br />

6<br />

Note: The <strong>FIREX</strong> hoarding systems described above are approved<br />

up to 5 m in height.<br />

▲ A 2-hour FRP <strong>FIREX</strong> Hoarding System.<br />

18


19<br />

SMOKE BARRIERS<br />

The <strong>FIREX</strong> Smoke Barrier is tested in accordance with BS 476: Part 22: 1987. The advantages of the<br />

<strong>FIREX</strong> Fire Barrier are:<br />

• 4 hours fire rating<br />

• Space saving<br />

• Lightweight<br />

• Water-resistant<br />

• High impact resistant<br />

<strong>FIREX</strong><br />

Smoke Barriers<br />

• Fungi-resistant<br />

• Termite-repellent<br />

• Safe to use<br />

• Easy to install<br />

• Cost-effective<br />

Meets INTEGRITY CRITERION of BS 476: Part 22: 1987<br />

7<br />

3<br />

7<br />

Ceiling<br />

3<br />

5<br />

6<br />

2<br />

1<br />

1<br />

4<br />

Technical Data:<br />

1 hour fire rating, integrity in accordance with BS 476: Part 22.<br />

Nominal thickness of smoke barrier: 62 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

3) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

4) Horizontal steel U channel 50 x 50 x 0.6 mm<br />

if height of smoke barrier > 1220 mm<br />

5) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

6) M6 anchor bolt at approx. 500 mm centres.<br />

7) M4 self-tapping screws at approx. 200 mm centres.


SMOKE BARRIERS<br />

<strong>FIREX</strong><br />

8<br />

Smoke Barriers<br />

Meets INTEGRITY CRITERION of BS 476: Part 22: 1987<br />

3<br />

4<br />

8<br />

Ceiling<br />

2<br />

4<br />

7<br />

2<br />

6<br />

1<br />

4<br />

2<br />

1<br />

5<br />

Technical Data:<br />

4 hours fire rating, integrity in accordance with BS 476: Part 22.<br />

Nominal thickness of the smoke barrier: 74 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 75 mm wide 6 mm thick<br />

3) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

4) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

5) Horizontal steel U channel 50 x 50 x 0.6 mm<br />

if height of smoke barrier > 1220 mm<br />

6) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

7) M6 anchor bolt at approx. 500 mm centres.<br />

8) M4 self-tapping screws at approx. 200 mm centres.<br />

4 hours fire rating, integrity in accordance with BS 476: Part 22.<br />

Nominal thickness of the fire barrier for<br />

rolling shutter doorset: 124 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

each side<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 75 mm wide 6 mm thick<br />

3) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

4) Top and bottom steel U channels 100 x 50 x 6 mm<br />

5) Horizontal steel U channel (1220 mm c/c) 100 x 50 x 6 mm<br />

6) Vertical steel U channel (1220 mm c/c) 100 x 50 x 6 mm<br />

Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

7) M10 anchor bolt at approx. 500 mm centres.<br />

8) M6 self-tapping screws at approx. 200 mm centres.<br />

Notes:<br />

1. The height of the <strong>FIREX</strong> Fire Barrier for Rolling Shutter Doorset<br />

can be up to 3.75 m.<br />

2. Screw holes shall be predrilled.<br />

3. Please consult New City Resources' technical department if<br />

service penetration openings are required.<br />

20


<strong>FIREX</strong> E&M Services Enclosures provide fire resisting construction to general electrical and maintenance<br />

services. The <strong>FIREX</strong> E&M services enclosure system is the only system to achieve 4 hours integrity and<br />

2 hours insulation in accordance with BS 476: Part 22: 1987 using one layer of 6 mm board. The<br />

advantages of the <strong>FIREX</strong> E&M Services Enclosure are:<br />

• 4 hours fire rating<br />

• Space saving<br />

• Lightweight<br />

• Water-resistant<br />

• High impact resistant<br />

Cladding of existing services afterwards.<br />

Meets INTEGRITY CRITERION of BS 476: Part 22: 1987<br />

21<br />

E<br />

<strong>FIREX</strong><br />

Detail A<br />

Detail A<br />

Detail C<br />

NCLOSURES FOR E&M SERVICES<br />

6<br />

Enclosures for E&M Services<br />

Detail B<br />

3<br />

5<br />

6<br />

1<br />

5<br />

• Fungi-resistant<br />

• Termite-repellent<br />

• Safe to use<br />

• Easy to install<br />

• Cost-effective<br />

1 2 4<br />

1<br />

2<br />

7<br />

Detail C<br />

Detail D<br />

Technical Data:<br />

4 hours fire rating, integrity in accordance with BS 476:<br />

Part 22; internal or external fire.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Steel channel collar minimum 50 x 25 x 0.5 mm at butt<br />

joints of approx. 600 mm centres.<br />

3) E&M services such as cable trunking and steel pipes.<br />

4) Hanger diameter sized to limit stress not to exceed<br />

6 N/mm 2 .<br />

5) M4 self-tapping screws at approx. 150 mm centres.<br />

6) Steel angles minimum 30 x 50 x 0.6 mm at corners.<br />

7) 50 mm wide x 0.6 mm thick steel strip.<br />

Note: 1, 2 and 3-sided solutions in combination with walls<br />

and ceilings are approved, details upon request.<br />

The above details are applicable for enclosures of<br />

dimensions not exceeding 1220 x 1220 mm.<br />

5<br />

6<br />

1<br />

5<br />

1<br />

4<br />

2<br />

Detail B<br />

Detail D


ENCLOSURES FOR E&M SERVICES<br />

<strong>FIREX</strong><br />

Enclosures for E&M Services<br />

Cladding of existing services afterwards.<br />

Meets INSULATION AND INTEGRITY CRITERION of BS 476: Part 20: 1987<br />

10<br />

1<br />

3<br />

6<br />

Detail A<br />

2<br />

1<br />

10 7<br />

6 3 5<br />

Detail F<br />

Cross section through duct<br />

Longitudinal section through duct<br />

13<br />

2<br />

2<br />

4<br />

5<br />

7<br />

Technical Data:<br />

4 hours integrity and 2 hours insulation fire rating in<br />

accordance with BS 476: Part 20; internal or external fire.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

3) Ceramic fiber raw density ≥ 128 kg/m 3 63 mm thick<br />

4) Steel angle minimum 50 x 50 x 0.6 mm at corners.<br />

5) E&M services like cable trunking and steel pipes, which<br />

are self-supporting.<br />

6) M4 self-tapping screws at approx. 200 mm centres.<br />

Screw-to-edge spacing should be at least 20 mm.<br />

7) Steel channel collar minimum 50 x 30 x 0.6 mm at butt<br />

joints of approx. 610 mm centres. All joints to be sealed<br />

with intumescent joint sealant.<br />

8) M6 anchor at least 38 mm long at approx. 600 mm<br />

centres.<br />

9) Steel cantilever arm (max. length = 1220 mm) at approx.<br />

1220 mm centres and located below channel collar.<br />

The steel cantilever arm is not attached to the enclosure<br />

and the cantilever bracket should be secured to the<br />

adjoining wall using suitable steel anchors at least<br />

50 mm long.<br />

10) Threaded rod hanger min. 10 mm diameter and stress<br />

not to exceed 10 N/mm 2 and 6 N/mm 2 for 2 hours and<br />

4 hours integrity respectively. The steel horizontal<br />

bearers are 50 x 50 x 3 mm angle or equivalent located<br />

at approx. 1220 mm centres. All hanger penetration<br />

openings to be sealed with intumescent joint sealant.<br />

11) 25 x 25 x 0.5 mm thick steel angle at approx. 600mm<br />

centres.<br />

12) M4 self-tapping screws at least 75 mm in length.<br />

13) Concrete nail 3.5 mm shank diameter and not less than<br />

22 mm long at approx. 200 mm centres.<br />

Note: The above details are applicable for enclosures of<br />

dimensions not exceeding 1220 x 1220 mm.<br />

22


ENCLOSURES FOR E&M SERVICES<br />

<strong>FIREX</strong><br />

Enclosures for E&M Services<br />

Cladding of existing services afterwards.<br />

Meets INSULATION AND INTEGRITY CRITERIA of BS 476: Part 20: 1987<br />

23<br />

2<br />

1<br />

6<br />

1<br />

4<br />

4<br />

One-Sided Enclosure Two-Sided Enclosure<br />

Three-Sided Enclosure Three-Sided Enclosure<br />

7<br />

3<br />

Detail A Detail B<br />

2<br />

6<br />

7<br />

3<br />

11<br />

1<br />

1<br />

12<br />

Detail E<br />

Detail C<br />

4 7 2<br />

Detail C<br />

Detail D Detail E Detail F<br />

8<br />

4 6 7<br />

9<br />

6<br />

2<br />

Detail D Detail B<br />

4 6 7<br />

1 2 9<br />

8 2 10<br />

9


FIRE-RATED DOORS<br />

<strong>FIREX</strong><br />

Fire-Rated Wood Doors<br />

Meets INSULATION AND INTEGRITY CRITERIA of BS 476: Part 22: 1987<br />

1<br />

2<br />

5<br />

<strong>FIREX</strong><br />

Technical Data:<br />

1 hour fire rating, insulation and integrity in accordance<br />

with BS 476: Part 22.<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Honeycomb or other insulating materials.<br />

3) Plywood layer.<br />

4) Top and bottom wood channels.<br />

5) Wood door frame.<br />

Fire-Rated Single Leaf Steel Doors<br />

Meets INSULATION AND INTEGRITY CRITERIA of BS 476: Part 22: 1987<br />

4<br />

6<br />

1<br />

2<br />

3<br />

Ceiling<br />

Floor<br />

Cross section<br />

5<br />

4<br />

3<br />

5<br />

10<br />

7<br />

Note: Construction details are available upon request.<br />

Technical Data:<br />

4 hours integrity and 30 minutes insulation fire rating<br />

in accordance with BS 476: Part 22.<br />

Wall<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Mineral wool density ≥ 60 kg/m 3 53 mm thick<br />

3) Steel face sheet 1.5 mm thick<br />

4) Steel door frame. 2.3 mm thick<br />

5) Door lock with level handle.<br />

6) Door closer.<br />

7) Steel door section.<br />

8) M8 anchor bolt.<br />

9) Door hinge.<br />

10) 40 x 3 mm thick steel bar with connecting pin as stiffener.<br />

Note: Construction details are available upon request.<br />

8 5 2 4<br />

7 3<br />

1<br />

Horziontal section<br />

9<br />

Wall<br />

24


25<br />

SOLID WALL FIRE-RATING UPGRADE<br />

<strong>FIREX</strong><br />

Wall System<br />

Meets INSULATION AND INTEGRITY CRITERIA of BS 476: Part 22: 1987<br />

Side View<br />

bl<br />

8 1 2 6<br />

Side View<br />

bm<br />

Horizontal View<br />

9 1 2 3 7<br />

Horizontal View<br />

3<br />

4<br />

1<br />

5<br />

2<br />

9<br />

8<br />

4<br />

7<br />

4<br />

5<br />

1<br />

2<br />

6<br />

3<br />

bk<br />

9<br />

5<br />

8<br />

bl<br />

bk<br />

bm<br />

bl<br />

2<br />

Technical Data:<br />

Upgrade fire rating from 1 hour insulation and integrity to<br />

2 hours insulation and integrity in accordance with BS 476: Part<br />

22 with fire on either side.<br />

Nominal thickness of wall:<br />

Concrete wall (75 mm thick): 131 mm<br />

Brick wall (100 mm thick): 156 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) Ceramic fiber raw density ≥ 128 kg/m 3 50 mm thick<br />

3) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

Ceramic fiber seal<br />

4) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

5) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

6) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

7) Wall steel U channel 50 x 50 x 0.6 mm<br />

8) M4 self-tapping screws at approx. 200 mm centres.<br />

9) 6 mm dia. concrete nail at approx. 600 mm centres.<br />

10) 6 mm dia. concrete nail at approx. 500 mm centres.<br />

11) Brick or concrete wall.<br />

Technical Data:<br />

Upgrade fire rating from 2 hours insulation and integrity to<br />

4 hours insulation and integrity in accordance with BS 476: Part<br />

22 with fire on either side.<br />

Nominal thickness of wall:<br />

Concrete wall (100 mm thick): 168 mm<br />

Brick wall (100 mm thick + 13 mm gypsum<br />

plaster on each side): 194 mm<br />

Brick wall (225 mm thick): 293 mm<br />

1) <strong>FIREX</strong> <strong>BOARD</strong> 1 x 6 mm thick<br />

2) <strong>FIREX</strong> <strong>BOARD</strong> fillet 75 mm wide 6 mm thick<br />

3) Ceramic fiber raw density ≥ 128 kg/m 3 63 mm thick<br />

4) <strong>FIREX</strong> <strong>BOARD</strong> fillet 50 mm wide 6 mm thick<br />

Ceramic fiber seal<br />

5) Top and bottom steel U channels 50 x 32 x 0.6 mm<br />

6) Horizontal steel U channel (1220 mm c/c) 50 x 50 x 0.6 mm<br />

7) Vertical steel U channel (610 mm c/c) 50 x 50 x 0.6 mm<br />

8) Wall steel U channel 50 x 50 x 0.6 mm<br />

9) M4 self-tapping screws at approx. 200 mm centres.<br />

10) 6 mm dia. concrete nail at approx. 600 mm centres.<br />

11) 6 mm dia. concrete nail at approx. 500 mm centres.<br />

12) Brick or concrete wall.


Notes:<br />

26


For the latest information about NCR, please refer to www.newcityresources.com. For inquiries and<br />

samples, please contact:<br />

NORTH AND SOUTH AMERICA<br />

NEW CITY RESOURCES INC.<br />

N C R Industrial Centre<br />

250 Baseline Road, East<br />

BOWMANVILLE, ONT. L1C 1A4<br />

C A N A D A<br />

Tel: (905) 697 3888 Fax: (905) 697 0980<br />

E-Mail: info@newcityresources.com<br />

CHINA • JAPAN • KOREA<br />

NEW CITY RESOURCES INC.<br />

Firex Industrial Centre<br />

18 Gangxing West Road<br />

Dakun Industrial Zone • Songjiang District<br />

SHANGHAI, CHINA<br />

Tel: (8621) 3785 9008 Fax: (8621) 3785 9009<br />

E-Mail: ncr-asia@newcityresources.com<br />

DISTRIBUTOR:<br />

EUROPE • AFRICA • RUSSIA<br />

NEW CITY RESOURCES INC.<br />

BIC Ling Kee House<br />

1 Christopher Road<br />

East Grinstead, Sussex RH19 3BT<br />

UNITED KINGDOM<br />

Tel: (01342) 318 980 Fax: (01342) 410 980<br />

E-Mail: ncr-europe@newcityresources.com<br />

ASIA-PACIFIC • AUSTRALIA<br />

NEW CITY RESOURCES INC.<br />

Unicorn Trade Centre, 7/F<br />

131 Des Voeux Road<br />

Central<br />

HONG KONG<br />

Tel: (852) 2541 1828 Fax: (852) 3105 0980<br />

E-Mail: ncr-asia@newcityresources.com<br />

New City Resources Inc. disclaims responsibility for results of use of this information which is furnished without charge, or anything<br />

mentioned herein. It is the user's responsibility to make or be guided by his own tests in determining suitability of any product, method<br />

or apparatus. Since the conditions of use are beyond our control, all risks are borne by the user.<br />

3/2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!