Date: 2003-07 <strong>ISO</strong>/<strong>TC</strong> <strong>108</strong>/<strong>SC</strong> 3 N <strong>388</strong>-<strong>CEN</strong>/<strong>TC</strong> <strong>231</strong> N <strong>439</strong><br />

Report of voting on doc. <strong>108</strong>/3 N 367-<strong>CEN</strong>/<strong>TC</strong> <strong>231</strong> N 402<br />

Second <strong>ISO</strong>/CD 8041 "Human response to vibration - Measuring instrumentation"<br />

1 2 (3) 4 5 (6) (7)<br />

Comment (justification for change) by the MB Proposed change by the MB Secretariat observations<br />

on each comment submitted<br />

Type<br />

of<br />

comment2<br />

Paragraph/<br />

Figure/Table/<br />

Note<br />

(e.g. Table 1)<br />

Clause No./<br />

Subclause No./<br />

Annex<br />

(e.g. 3.1)<br />

MB 1<br />

reference, i.e. introduced into<br />

clause 2.<br />

DE Z Biblio ed move <strong>ISO</strong> 16063-21 to clause 2 Rejected – <strong>ISO</strong> 16063 (all<br />

parts) is in clause 2,<br />

Reference in bibliography<br />

therefore deleted<br />

DE Z Biblio ed delete IEC 60651 since this is outdated, see IEC 61672-1 Accepted<br />

DE Z Biblio ed delete EN 50082-2 since it is replaced by IEC 61000-6-2 Accepted<br />

DE Z Biblio ed delete EN 55022 since it is identical with CISPR 22:1997 Accepted<br />

Accepted<br />

DE Z Biblio ed move the GUM to clause 2 since it is quoted in 11.1 and<br />

12.1 with "shall"<br />

DE Z Biblio ed check quotation number [8] in C.2.3! Accepted – should now be<br />

[6]<br />

Comment appreciated.<br />

FR 0 ge France appreciates the work done, otherwise it appears<br />

that CD2 is not covering the field of <strong>ISO</strong> 5349-2.<br />

Rejected – Human vibration<br />

measurement standards<br />

require measurement in<br />

single axes. For hand arm<br />

vibration the three axes are<br />

combined to produce an<br />

overall level. If these<br />

transducers are applicable to<br />

human vibration<br />

measurement, then the new<br />

standard could be included in<br />

the bibliography – but only<br />

when it appears as a full<br />

standard.<br />

Add IEC 60747-14-4, 47E/220/CD to the list of<br />

references.<br />

JP 02 te IEC has issued the first committee draft for semiconductor<br />

accelerometer standard 60747-14-4 47E/220/CD, where<br />

acceleration is treated as vector quantity. Calibration is<br />

described using vector acceleration.<br />

1 MB = Member body (enter the <strong>ISO</strong> 3166 two-letter country code, e.g. CN for China; comments from the <strong>ISO</strong>/CS editing unit are identified by **)<br />

2 Type of comment: ge = general te = technical ed = editorial<br />

NOTE Columns 1, 2, 4, 5 are compulsory.<br />

page 11 of 25<br />

<strong>ISO</strong> electronic balloting commenting template/version 2001-10