(7)<br />
Absorber<br />
Because the self-contained cooling unit<br />
does not utilize an electric compressor<br />
or pump, the cooling coils can be operated<br />
from a variety of heat sources. LP<br />
gas, 120 volts AC and 12 volts DC<br />
heating elements are the most commonly<br />
used heat sources for recreational<br />
vehicle applications.<br />
(9)<br />
Before this cooling system can properly<br />
extract heat from the cabinet of the<br />
refrigerator, three requirements for proper<br />
refrigerator operation must be met.<br />
These are precise heat, specified ventilation<br />
and proper leveling.<br />
TEMPERATURE<br />
EXCHANGER<br />
D-6-4<br />
ABSORBER<br />
THE ABSORPTION SYSTEM<br />
TEMPERATURE<br />
EXCHANGER<br />
CONDENSER<br />
_<br />
EVAPORATOR<br />
THREE REQUIREMENTS<br />
FOR PROPER OPERATION<br />
1. Level<br />
2. Air Flow (Ventilation)<br />
3. Heat