Connecting Multiple <strong>Water</strong> <strong>Heater</strong>s<br />
The EZConnect cable is an optional accessory<br />
that connects 2 water heaters and allows them to<br />
function as one hot water source.<br />
The MSA-2M and MSA-2S packs are optional<br />
accessories that connect 2 to 5 water heaters<br />
and allow them to function as one hot water<br />
source.<br />
Refer to the instructions that come with the<br />
accessory for complete installation information.<br />
Guidelines<br />
• Do not install both the EZConnect and the<br />
MSA packs because they are not designed to<br />
operate together.<br />
• <strong>Water</strong> heaters connected with the<br />
EZConnect Cable or the MSA-2M and MSA-<br />
2S packs cannot be used for the bath fill<br />
function.<br />
• <strong>Water</strong> heaters should be installed less than 18<br />
inches apart so that the cables will reach<br />
between units and to prevent temperature<br />
fluctuations (cold water sandwich effect) when<br />
the water is shut off and turned back on.<br />
• Temperature settings can only be changed on<br />
the controller for the primary unit. (This<br />
changes the temperature on all units within the<br />
MSA or EZConnect system.)<br />
High Altitude Installations<br />
Set switches 2 and 3 to the values shown in table<br />
below for your altitude. The default setting for the<br />
appliance is 0-2000 ft (0-610 m) with switches No. 2<br />
and No. 3 in the OFF position.<br />
0-2000 ft<br />
(0-610 m)<br />
2001-5200 ft<br />
(610-1585 m)<br />
34 VB Series Indoor LS Manual<br />
Number of<br />
Connected<br />
Accessories Necessary:<br />
<strong>Water</strong> <strong>Heater</strong>s:<br />
2 (1) EZConnect Cable or (1) MSA-2M<br />
3 (1) MSA-2M and (1) MSA-2S<br />
4 (1) MSA-2M and (2) MSA-2S<br />
5 (1) MSA-2M and (3) MSA-2S<br />
WARNING<br />
5201-7700 ft<br />
(1585-2347 m)<br />
DO NOT adjust the other<br />
switches unless specifically<br />
instructed to do so.<br />
7701-10200 ft<br />
(2347-3109 m)<br />
Switch No. 2 OFF OFF ON ON<br />
Switch No. 3 OFF ON OFF ON<br />
Switch No.<br />
O<br />
F<br />
F<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Activation Options for EZConnect<br />
One unit in standby allows for quicker activation time with<br />
flow rates within the capacity of a single unit.<br />
Two units in standby allows for quicker delivery temperature<br />
for flow rates requiring both units.<br />
Applicable for the RL75 and RL94 models only.<br />
Switch No.<br />
O<br />
F<br />
F<br />
Model<br />
RL75,<br />
RL94<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Number of units<br />
in standby<br />
Switch No.<br />
O<br />
F<br />
F<br />
ON<br />
1<br />
2<br />
Position of switch No. 5 in<br />
bank of 6 switches<br />
1 ON<br />
2 OFF (default)<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Switch No.<br />
O<br />
F<br />
F<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8