21.03.2013 Views

gHK DETERMINATION OP COUMARIN 301 TOBACCO AND ...

gHK DETERMINATION OP COUMARIN 301 TOBACCO AND ...

gHK DETERMINATION OP COUMARIN 301 TOBACCO AND ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Vith reft ace to Table I the control cigr rites (made to Park<br />

Drive specifications using Blend }2 with \. added flavour) appear<br />

to have a residual coumarin level of 4*4 ± 3*4 ug/cig. A coumarin<br />

analysis on the smoke of 25 control cigarettes yielded the result<br />

shown in Table V, -<br />

TABLE V <strong>COUMARIN</strong> CONTENT OF<br />

(v) RECOVERY<br />

CONTROL CIGARETTES<br />

<strong>COUMARIN</strong> IN<br />

<strong>TOBACCO</strong><br />

(w/oig)<br />

4.4<br />

<strong>COUMARIN</strong> IN<br />

SMOKE<br />

fag/cig)<br />

Coumarin recovery is greater than 95&<br />

(vi) DETECTION LIMIT<br />

The lower limit for detection of coumarin by this method is<br />

1-2 pg/cig« in the smoke which corresponds to a coumarin<br />

level in tobacco of approximately 5pg/cigarette.<br />

The measured coumarin content at low levels will be Bubject to<br />

interference from impurities (see Table V and Discussion).<br />

DISCUSSION<br />

http://legacy.library.ucsf.edu/tid/iyl97h00/pdf<br />

(i)* The principal assumption made in using this method to measure<br />

coumarin is that there are no other compounds with the same<br />

retention time as coumarin in the final GO analysis* Comparison<br />

of the results in Tables III and IV shows that extraneous compounds<br />

contributing to the coumarin peak on the GC after one column<br />

chromatography step have been removed by the second column* This<br />

was observed experimentally by collecting fractions from the second<br />

column and testing for coumarin by gas chromatography* The<br />

coumarin comes through in the 50-75^1 fraction (by comparison with<br />

a standard coumarin solution passed through the column) while<br />

impurities with tbie same retention time as coumarin are contained<br />

in the first 50ml~'from the column,<br />

*<br />

(ii) When the smoke from 25 control cigarettes containing no added<br />

coumarin but with an apparent coumarin level of 4.4 + 3.4 Pfi/cig,<br />

is analysed a coumarin (?) level of 1*3pg/cig. is obtained after<br />

a two-stage clean-up. Allowances for this background peak can<br />

be made in two ways a) if the background peak is coumarin the<br />

measured value of tyig/cig. in the smoke of normal Park Drive<br />

cigarettes comprises 2.7 )ig/cig. from the coumarin added in the<br />

flavouring process and '\*5yg/cig, from the coumarin present in .<br />

Blend 32* b) if the peak in the control sample is not coumarin<br />

but a compound with the same retention time, the coumarin level<br />

in Park Drive smoke is

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!