4.2 System integration.<br />
The design of the <strong>lighting</strong> equipment shall not interfere with the operation of the <strong>system</strong><br />
at <strong>night</strong>, with or without NVIS, or during the daytime.<br />
4.2.1 Lighting pro<strong>vision</strong>s.<br />
The design and location of the <strong>lighting</strong> equipment shall optimize visual performance and<br />
minimize the effects on NVIS. The lights shall not cause direct or indirect glare or<br />
interfere with the aircrew member’s interior or exterior unaided <strong>vision</strong> and with the<br />
image intensification capabilities of the NVIS.<br />
4.2.2 Compartment <strong>lighting</strong>.<br />
Illuminance levels shall be as required by TABLE I, unless otherwise specified by the<br />
acquiring activity. Chromaticity and spectral radiance limits shall be as specified in<br />
TABLE II and TABLE III, respectively.<br />
TABLE I. <strong>General</strong> <strong>lighting</strong> for crew stations and compartments. *<br />
CREWSTATION AREA, GENERAL ILLUMINATION<br />
CONTROL PANELS NOT ILLUMINATED<br />
(REQUIRING IN-FLIGHT ADJUSTMENT AND<br />
8<br />
ILLUMINATED LEVEL IN LUX<br />
AND (FOOT CANDLES) AT<br />
RATED DRIVE CONDITION<br />
MIN MAX<br />
10.8 (1)<br />
(Aisle<br />
floor)<br />
215 (20)<br />
(Crew lap<br />
level)<br />
54 (5) 108 (10)<br />
OPERATION)<br />
INSTRUMENT PANEL AND CONSOLES 21.5 (2) 108 (10)<br />
PASSAGEWAYS AND AISLES (ON FLOOR) 2.15 (0.2) 54 (5)<br />
CARGO COMPARTMENT (ON FLOOR) 2.15 (0.2) 54 (5)<br />
LOADING AND RAMP AREAS (ON FLOOR) 21.5 (2) 10.8 (10)<br />
CREWSTATION LOCATIONS FOR NAVIGATIONAL<br />
AND SYSTEMS COMPUTATIONS TASKS<br />
(LIGHT ON WORK AREAS)<br />
323 (30) 646 (60)<br />
AUXILIARY POWER PLANT, ELECTRICAL AND<br />
ELECTRONIC COMPARTMENTS<br />
(LIGHT ON WORK AREAS)<br />
54 (5) 108 (10)<br />
* Continuous intensity control of the above <strong>lighting</strong> from full bright to 0.02% of full bright<br />
and “off” is required.<br />
4.2.3 Emergency exit <strong>lighting</strong>.<br />
Emergency exit <strong>lighting</strong> sub<strong>system</strong>s that may be automatically activated during flight<br />