MIL-STD-3009<br />
5.7.12.2 Secondary <strong>lighting</strong> radiance measurements.<br />
The appropriate drive condition shall be applied to the test light to illuminate the<br />
reflectance standard such that the luminance requirement of TABLE III is met at a<br />
distance of 12 inches. The test light shall be oriented perpendicular to the reflectance<br />
standard. The spectroradiometer shall be set up such that the reflectance standard is<br />
at a 45° angle with the line of sight of the spectroradiometer. The spectral radiance of<br />
the reflectance standard shall be measured. The corrected spectral radiance shall then<br />
be calculated using formula 12 and the NVIS radiance shall be calculated using the<br />
corrected spectral radiance and the formulas in 5.7.12.1.<br />
5.7.12.3 Illuminated control radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1.<br />
5.7.12.4 Compartment <strong>lighting</strong> radiance measurements.<br />
The NVIS radiance inspection for compartment <strong>lighting</strong> shall be the same as for<br />
secondary <strong>lighting</strong> (5.7.12.2) except that the distance between the test light and the<br />
reflectance standard shall be adjusted to be equivalent to the distance at which the<br />
<strong>lighting</strong> component will be used when installed in an <strong>aircraft</strong>.<br />
5.7.12.5 Utility, work, map, and inspection <strong>lighting</strong> radiance measurements.<br />
Inspection shall be the same as for secondary <strong>lighting</strong> (5.7.12.2).<br />
5.7.12.6 Caution and advisory light radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1.<br />
5.7.12.7 Jump light radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1.<br />
5.7.12.8 Signal indicator radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1.<br />
5.7.12.9 Electronic and electro-optical display radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1. The acquiring activity shall specify the<br />
number and type of colors or composite colors that shall be measured. The<br />
spectroradiometer shall be placed so that as much of the display as reasonably<br />
possible is within the spectroradiometer test field.<br />
5.7.12.10 HUD <strong>system</strong> radiance measurements.<br />
Inspection shall be in accordance with 5.7.12.1 and as stated herein. If the display is<br />
unable to generate the luminance level specified in TABLE III, NVIS radiance shall be<br />
measured at the display’s maximum luminance level and scaled to the specified<br />
luminance level.<br />
32