Lighting<br />

components<br />

MIL-STD-3009<br />

TABLE III. NVIS radiance requirements (metric units)<br />

TYPE 1 TYPE II<br />

Paragraph Class A Class B Class A Class B<br />

Not Less<br />

Than:<br />

(nNRA)<br />

Not Greater<br />

Than:<br />

(nNRA)<br />

cd/m 2 Not Less<br />

Than:<br />

(nNRB)<br />

Not Greater<br />

Than:<br />

(nNRB)<br />

14<br />

cd/m<br />

2<br />

Not Less<br />

Than:<br />

(nNRA)<br />

Not Greater<br />

Than:<br />

nNRA)<br />

cd/m 2<br />

Not Less<br />

Than:<br />

(nNRB)<br />

Not Greater<br />

Than:<br />

(nNRB)<br />

Primary 4.3.5.1 --- 0.17 0.343 --- 0.17 0.343<br />

Secondary 4.3.5.2 --- 0.17 0.343 --- 0.17 0.343<br />

Illuminated<br />

controls<br />

4.3.5.3 --- 0.17 0.343 1/ Same as --- 0.17 0.343 1/ Same as<br />

Compartment 4.3.5.4 --- 0.17 0.343 Class A --- 0.17 0.343 Class A<br />

Utility, map, work, Green 4.3.5.5 --- 0.17 0.343 --- 0.17 0.343<br />

and Inspection<br />

lights<br />

White 4.3.5.5 1.0 0.343 1.0 0.343<br />

Caution and<br />

advisory lights<br />

4.3.5.6 --- 0.17 0.343 --- 0.17 0.343<br />

Jump lights 4.3.5.7 17.1 50 17.1 16 47 17.1 --- 50 17.1 --- 47 17.1<br />

Warning signal 4.3.5.8 50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />

Master caution<br />

signal<br />

4.3.5.8 50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />

Emergency exit<br />

<strong>lighting</strong><br />

50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />

Electronic and<br />

--- 0.17 1.71<br />

0.16 1.71 --- 0.17 1.71 -- 0.16 1.71<br />

electro-optical<br />

displays<br />

(monochromatic)<br />

---<br />

Electronic and White --- 2.3 1.71<br />

2.2 1.71 --- 2.3 1.71 --- 2.2 1.71<br />

electro-optical<br />

displays<br />

(multi-color)<br />

---<br />

MAX --- 12 1.71 --- 11 1.71 --- 12 1.71 --- 11 1.71<br />

HUD <strong>system</strong>s 4.3.5.10 1.71 5.1 17.1 1.6 4.7 17.1 --- 17 17.1 --- 1.6 17.1<br />

Where:<br />

nNRA = nano NVIS radiance requirements for Class A equipment.<br />

nNRB = nano NVIS radiance requirements for Class B equipment.<br />

"nano", abbreviated "n", represents a factor of 10 -9 , which is factored out of the radiance numbers in this table.<br />

cd/m 2 = Candela per square meter, sometimes called "nits".<br />

NOTE 1. For these <strong>lighting</strong> components, Class B equipment shall meet all Class A requirements of this specification. The relative NVIS response<br />

data for Class A equipment, GA(λ) (table III.a.), shall be substituted for GB(λ) to calculate NVIS radiance.<br />

cd/m 2