Lighting<br />
components<br />
MIL-STD-3009<br />
TABLE III. NVIS radiance requirements (metric units)<br />
TYPE 1 TYPE II<br />
Paragraph Class A Class B Class A Class B<br />
Not Less<br />
Than:<br />
(nNRA)<br />
Not Greater<br />
Than:<br />
(nNRA)<br />
cd/m 2 Not Less<br />
Than:<br />
(nNRB)<br />
Not Greater<br />
Than:<br />
(nNRB)<br />
14<br />
cd/m<br />
2<br />
Not Less<br />
Than:<br />
(nNRA)<br />
Not Greater<br />
Than:<br />
nNRA)<br />
cd/m 2<br />
Not Less<br />
Than:<br />
(nNRB)<br />
Not Greater<br />
Than:<br />
(nNRB)<br />
Primary 4.3.5.1 --- 0.17 0.343 --- 0.17 0.343<br />
Secondary 4.3.5.2 --- 0.17 0.343 --- 0.17 0.343<br />
Illuminated<br />
controls<br />
4.3.5.3 --- 0.17 0.343 1/ Same as --- 0.17 0.343 1/ Same as<br />
Compartment 4.3.5.4 --- 0.17 0.343 Class A --- 0.17 0.343 Class A<br />
Utility, map, work, Green 4.3.5.5 --- 0.17 0.343 --- 0.17 0.343<br />
and Inspection<br />
lights<br />
White 4.3.5.5 1.0 0.343 1.0 0.343<br />
Caution and<br />
advisory lights<br />
4.3.5.6 --- 0.17 0.343 --- 0.17 0.343<br />
Jump lights 4.3.5.7 17.1 50 17.1 16 47 17.1 --- 50 17.1 --- 47 17.1<br />
Warning signal 4.3.5.8 50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />
Master caution<br />
signal<br />
4.3.5.8 50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />
Emergency exit<br />
<strong>lighting</strong><br />
50 150 51.5 47 140 51.5 --- 150 51.5 --- 140 51.5<br />
Electronic and<br />
--- 0.17 1.71<br />
0.16 1.71 --- 0.17 1.71 -- 0.16 1.71<br />
electro-optical<br />
displays<br />
(monochromatic)<br />
---<br />
Electronic and White --- 2.3 1.71<br />
2.2 1.71 --- 2.3 1.71 --- 2.2 1.71<br />
electro-optical<br />
displays<br />
(multi-color)<br />
---<br />
MAX --- 12 1.71 --- 11 1.71 --- 12 1.71 --- 11 1.71<br />
HUD <strong>system</strong>s 4.3.5.10 1.71 5.1 17.1 1.6 4.7 17.1 --- 17 17.1 --- 1.6 17.1<br />
Where:<br />
nNRA = nano NVIS radiance requirements for Class A equipment.<br />
nNRB = nano NVIS radiance requirements for Class B equipment.<br />
"nano", abbreviated "n", represents a factor of 10 -9 , which is factored out of the radiance numbers in this table.<br />
cd/m 2 = Candela per square meter, sometimes called "nits".<br />
NOTE 1. For these <strong>lighting</strong> components, Class B equipment shall meet all Class A requirements of this specification. The relative NVIS response<br />
data for Class A equipment, GA(λ) (table III.a.), shall be substituted for GB(λ) to calculate NVIS radiance.<br />
cd/m 2