I2Cbus TD Trigger & Decode<br />

SPIbus TD Trigger & Decode<br />

Media contact: Patrick Brightman - SGW (973) 263-5475<br />

Editors’ Technical contact: Kenneth Johnson (845) 578-6094<br />

Customer contact: <strong>LeCroy</strong> Customer Care Center (800) 453-2769<br />

Website: www.lecroy.com<br />

<strong>LeCroy</strong> Introduces Powerful and Intuitive I2C and SPI Serial Data Trigger &<br />

Decode Options for WaveRunner Xi and WaveSurfer Xs<br />

Chestnut Ridge, NY, October 2 nd , 2006<br />

<strong>LeCroy</strong> ® Corporation introduces two new serial trigger and decode options that significantly enhance the<br />

power and capability of the WaveRunner Xi and WaveSurfer Xs oscilloscopes in the embedded test market.<br />

The I2Cbus TD and SPIbus TD Trigger & Decode options provide:<br />

• Flexible trigger capability on an Inter IC (I 2 C) or Serial Peripheral Interface (SPI) message, including<br />

powerful I 2 C conditional DATA triggering<br />

• Fast and intuitive protocol decode information overlayed on the DATA waveform<br />

• Search and zoom capability<br />

• Tabular display of protocol data that can be easily customized and exported to Excel ®<br />

Most Advanced and Powerful I 2 C and SPI Trigger Capability<br />

Conditional I 2 C Data Triggering Significantly Enhances Basic Triggering Capability<br />

Most I 2 C serial data triggers restrict the DATA condition to an “equal” condition only. In many common<br />

situations, this is all that is needed. However, to completely isolate specific events for better understanding<br />

and debug, a developer would like to trigger on DATA conditionally, using a condition other than “equal”.<br />

<strong>LeCroy</strong>’s I2Cbus TD provides this capability. For instance:<br />

• I 2 C often utilizes DATA bytes to specify memory locations in EEPROMs. I2Cbus TD’s conditional<br />

DATA trigger allows a developer to trigger on a range of DATA bytes that correspond to writes to<br />

specific memory blocks in the EEPROM.<br />

• When I 2 C-based sensors, such as analog to digital converters, are used in a design, the<br />

oscilloscope with I2Cbus TD can be used to monitor DATA outputs and trigger when DATA is


outside a safe operating range. This makes verification of proper operation a quick and simple<br />

task.<br />

Binary, Hex, or ASCII Trigger Setup – Trigger and Decode information can be viewed in the same format,<br />

aiding understanding.<br />

DATA positioning in a 2048 byte message – A developer could select the exact location of DATA to trigger<br />

on in a very long message. This is especially helpful for triggering on EEPROM programming sequences.<br />

Support for Simplified SPI – Simplified SPI does not use a Slave Select, and is supported in SPIbus TD.<br />

External Input Usable for Clock Signals – A developer is usually only concerned with the DATA waveform.<br />

By inputting the CLOCK waveform to the EXT input, an extra oscilloscope Channel is usable to view other,<br />

more important signals.<br />

Fast and Intuitive Protocol Decode Makes Understanding Quick and Easy<br />

Using advanced software algorithms developed for <strong>LeCroy</strong>’s CANbus TD Trigger & Decode, <strong>LeCroy</strong> has<br />

made it quick and easy for both the novice and expert to see and understand the protocol-decoded<br />

information. Decoded information is color coded and overlayed on top of the DATA waveform, with detail<br />

about the frame structure. Decode information intelligently condenses or expands as the timebase or zoom<br />

ratio setting changes, so it is easy to view the protocol data in a short or a long acquisition of messages. The<br />

decode operation is fast, even for long acquisitions, and the user can choose whether to display decoded<br />

data in Binary, Hex, or ASCII formats.<br />

Search/Zoom and Tabular Display Complete the Solution<br />

In addition to the Trigger & Decode capability, <strong>LeCroy</strong> also incorporates a Search/Zoom feature that is<br />

completely integrated with a user-definable Tabular display of protocol data. This is especially handy for<br />

location of specific events in long data records, like the WaveRunner Xi’s 10 Mpts or the WaveSurfer Xs’s<br />

2.5 Mpts. Simply enter the Search criteria, select NEXT, and a zoom trace is automatically created and<br />

scaled to show the message of interest. Or, display the Table, scroll through the listing of events, and<br />

“touch” a line in the Table to zoom automatically to that message.<br />

The Table also allows user customization, and can be easily exported to an Excel-compatible file with one<br />

button push.<br />

Engineers and technicians who would like to know more can contact <strong>LeCroy</strong> at 1-800-5<strong>LeCroy</strong> (1-800-553-<br />

2769) or visit the <strong>LeCroy</strong> Web site (www.lecroy.com).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!