DEO(W) Design Guide <strong>JRSLA</strong> 2 General Functional & Design Requirements<br />

Figure 2.5 System build <strong>JRSLA</strong>.<br />

16<br />

The requirements of the central and communal facilities of <strong>JRSLA</strong> differ from<br />

motel design, and these areas of system <strong>JRSLA</strong> blocks are often poorly considered.<br />

Utility rooms tend to be equipped as kitchens, with small domestic sinks<br />

unsuitable for washing outdoor clothing, and bathrooms and sitting rooms are not<br />

provided. The link blocks or junctions between the standard accommodation<br />

blocks, are also rarely 'designed', resulting in oversized circulation cores.<br />

The danger of accepting a ready-made design is that it may not be appropriate to<br />

the requirements of <strong>JRSLA</strong> in general, or to the building site or project in<br />

particular. Where adherence to the JSP315 scales is relaxed in part, i.e. relating to<br />

the ensuite facilities, it is important that the full accommodation provision is<br />

reconsidered, to ensure that the system build project is designed to bear strict<br />

relevance to its use as a <strong>JRSLA</strong>. For example:<br />

• A bathroom should be provided in addition to the ensuite shower rooms,<br />

one per wing or floor.<br />

A separate WC should be provided for use by visitors to the building,<br />

including cleaning staff.<br />

A staff rest room for cleaners, and a store for cleaning materials, may be<br />

required, depending on the size of the <strong>JRSLA</strong> and its proximity to other<br />

accommodation.<br />

A communal sitting room may be required on some units.<br />

The particular storage needs of the resident unit should be assessed, as the<br />

standard provision is often inadequate.<br />

Specification and Durability<br />

It is difficult to judge whether the specification of the system blocks, currently<br />

occupied by the RAF, is robust enough to withstand <strong>JRSLA</strong> use, as none are more<br />

than a few years old.<br />

Between bedrooms, the double skin timber construction provides good acoustic<br />

insulation. However, the deflection of timber floors, particularly within first floor<br />

corridors, gives the feeling of low quality to the building. Poor impact sound<br />

insulation between floors compounds this feeling of impermanence and has given<br />

rise to complaints of systems buildings being noisy.<br />

The space allowance for service ducts adjacent to the ensuite WC facilities varies<br />

with the system used. Good access is provided from the corridor but the space<br />

within the ducts is often inadequate for the service runs to be accommodated.