Table. 4. Cost <strong>of</strong> equipment<br />

Equipment Cost, roubles Cost, €<br />

Set <strong>of</strong> equipment for a mini-factory<br />

44,850,000 1,121,250<br />

System for crushing <strong>of</strong> raw material<br />

VacuumEcoDry <strong>drying</strong><br />

System for final product unloading<br />

Management terminal<br />

Video monitoring system<br />

The mini-factory includes back-up devices <strong>of</strong> the product main<br />

loading <strong>and</strong> unloading units.<br />

Granulation <strong>and</strong> packing line<br />

Mixer<br />

Magnetic separator<br />

Granulator<br />

Granules (pellets) cooler<br />

Cyclone separator<br />

Semi-automatic packing unit<br />

Boiler-house<br />

Water conditioning system<br />

Boiler<br />

Burner<br />

Accessories (sensors, fittings)<br />

5,000,000<br />

(the cost varies<br />

with<br />

manufacturers<br />

<strong>and</strong> is agreed<br />

upon in every<br />

particular case)<br />

4,000,000–<br />

6,000,000<br />

(the cost is<br />

agreed upon<br />

separately)<br />

125,000<br />

100,000–<br />

150,000<br />

Total 54,850,000 1,371,250<br />

In February, 2011, A. Bryukhanov, an expert from SZNIIMESH, together with Technical Director <strong>of</strong><br />

PF Primorskaya M. A. Smirnov had negotiations with the head <strong>of</strong> «Eco Development». A trip was<br />

scheduled to the place, where the described technology had been implemented. But further discussions <strong>and</strong><br />

more thorough analysis <strong>of</strong> available information showed that the company <strong>of</strong>fered only the design. They<br />

could show only a demonstration model (Figure 3) with much smaller productivity than required. The<br />

vacuum dryer had no Certificate <strong>of</strong> Compliance.<br />

Figure 3. Demonstration model <strong>of</strong> the vacuum dryer.<br />

Therefore, in spite <strong>of</strong> good characteristics <strong>of</strong> the <strong>of</strong>fered solution, its industrial scale introduction is a<br />

certain risk for PF Primorskaya.