Instruction Manual - Rodney Hunt Company
Instruction Manual - Rodney Hunt Company
Instruction Manual - Rodney Hunt Company
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Glydaseal Gate Adjustment<br />
All <strong>Rodney</strong> <strong>Hunt</strong> Glydaseal gates are carefully checked<br />
and adjusted at the factory prior to shipment to assure<br />
that they meet the specified leakage requirements. Further<br />
adjustment in the field will normally not be required,<br />
and no adjustment should be undertaken unless there is<br />
clear evidence that the seal attached to the disc is not<br />
contacting the PVC facing attached to the frame when<br />
the gate is fully closed. This can be determined by trying<br />
to place a feeler gauge between the disc seal and PVC<br />
seat facings (D and E) with the gate in the fully closed<br />
position.<br />
Any adjustment should be made when the water level is<br />
below the invert of the gate.<br />
If adjustment is necessary, the following procedures<br />
should be followed:<br />
1. Raise the gate disc (G) 1” to 1-1/2” above the flush<br />
bottom seal (I).<br />
2. Loosen the guide bar hex-head locking screw (A) on<br />
each side of the gate.<br />
3. Loosen the hex-nut (B) on each side of the frame.<br />
4. Re-tighten the hex-head screws (A) against the<br />
guide bar studs until the disc seal (E) is in contact with<br />
the PVC seat (D). The adjustment of each screw should<br />
be made a small amount at each time and alternate between<br />
the sides of the gate to distribute the load evenly.<br />
5. With a feeler gauge determine that the disc seal is<br />
in touch with the PVC seat across the top and along<br />
both sides of the gate.<br />
6. Once the adjustment has been made, re-tighten all<br />
hex-nuts (B) along each side of the gate.<br />
The Glydaseal is now ready for use. When the disc is<br />
fully closed the disc seal will be compressed the proper<br />
amount for low leakage performance.<br />
No other adjustments are required on the Glydaseal<br />
gate.<br />
Adjusting the bronze guide bar varies the seal compression.<br />
17