Glydaseal Gate Adjustment<br />

All <strong>Rodney</strong> <strong>Hunt</strong> Glydaseal gates are carefully checked<br />

and adjusted at the factory prior to shipment to assure<br />

that they meet the specified leakage requirements. Further<br />

adjustment in the field will normally not be required,<br />

and no adjustment should be undertaken unless there is<br />

clear evidence that the seal attached to the disc is not<br />

contacting the PVC facing attached to the frame when<br />

the gate is fully closed. This can be determined by trying<br />

to place a feeler gauge between the disc seal and PVC<br />

seat facings (D and E) with the gate in the fully closed<br />

position.<br />

Any adjustment should be made when the water level is<br />

below the invert of the gate.<br />

If adjustment is necessary, the following procedures<br />

should be followed:<br />

1. Raise the gate disc (G) 1” to 1-1/2” above the flush<br />

bottom seal (I).<br />

2. Loosen the guide bar hex-head locking screw (A) on<br />

each side of the gate.<br />

3. Loosen the hex-nut (B) on each side of the frame.<br />

4. Re-tighten the hex-head screws (A) against the<br />

guide bar studs until the disc seal (E) is in contact with<br />

the PVC seat (D). The adjustment of each screw should<br />

be made a small amount at each time and alternate between<br />

the sides of the gate to distribute the load evenly.<br />

5. With a feeler gauge determine that the disc seal is<br />

in touch with the PVC seat across the top and along<br />

both sides of the gate.<br />

6. Once the adjustment has been made, re-tighten all<br />

hex-nuts (B) along each side of the gate.<br />

The Glydaseal is now ready for use. When the disc is<br />

fully closed the disc seal will be compressed the proper<br />

amount for low leakage performance.<br />

No other adjustments are required on the Glydaseal<br />

gate.<br />

Adjusting the bronze guide bar varies the seal compression.<br />

17